- BZ#484117
The Logical Volume Manager in Red Hat Enterprise Linux 4.9 reports file descriptor leaks, resulting in the following error returned to the installation output:
File descriptor NUM (socket:XXXX) leaked on lvm invocation.
This message can be safely ignored.
- BZ#468097
When installing Red Hat Enterprise Linux 4 through an Network File System (NFS) server, the installer is unable to correctly close the NFS mount points. This might cause the NFS server to misbehave. In these cases Red Hat suggests the use of an HTTP server for installations.
- BZ#468097
On systems where the BIOS is able to do both legacy (acpiphp) and native (pciehp) PCI hotplugging, it is necessary for the administrator to choose a preferred method and explicitly prevent Red Hat Enterprise Linux 4 from loading the module for the undesired method. This is done by blacklisting the undesired module in /etc/modprobe.conf.
- BZ#449648
Red Hat discourages the use of quota on EXT3 file systems. This is because in some cases, doing so can cause a deadlock.
Testing has revealed that kjournald can sometimes block some EXT3-specific callouts that are used when quota is running. As such, Red Hat does not plan to fix this issue in Red Hat Enterprise Linux 4, as the modifications required would be too invasive.
Note that this issue is not present in Red Hat Enterprise Linux 5.
- BZ#452578
The Desktop Sharing connection icon displays its context menu when you double-click it, not when you right-click it. All other icons display their context menus when you right-click on them.
- BZ#451873
If the ib_ehca InfiniBand driver is loaded in port auto-detection mode (using module parameter nr_ports=-1), the IP-over-InfiniBand network interfaces (ibX) might become available too late. When this occurs, the ifup ibX command issued from the openibd startup script will fail; consequently, the ibX interface will not become available.
When this occurs, use the command rcnetwork restart to fix the problem.
- BZ#451873
Note that with eHCA2 adapters, bits 46 and 47 of these error indicator bits might return false positives.
- BZ#366961
On HP ICH10 workstations, audio is only enabled through the front 3.5mm jacks. As such, to receive any audio output or use recording, you should plug in your headphones, speakers, or microphones to the front jacks. At present, the rear jacks, internal speaker, and master volume for this workstation do not work.
- BZ#429727
With this update, the default PCI detection and ordering mode for the following models have changed:
HP Proliant DL 580 G5
HP Proliant DL 385 G2
HP Proliant DL 585 G2
These models use a device scanning and enumeration mode which is not the default for Red Hat Enterprise Linux 4 or 5. The mode used by these HP Proliant models could result in add-on cards being detected and added prior to onboard/internal devices. This unexpected ordering could cause difficulties when installing new instances of Red Hat Enterprise Linux, adding hardware, and maintenance.
The numbering of network interface cards (NIC) for the aforementioned HP Proliant models may change when they are updated with the Red Hat Enterprise Linux 4.7 kernel. The installer changes NIC numbering if the HWADDR=MAC ADDRESS parameter is not defined in /etc/sysconfig/network-scripts/ifcfg-eth[X] for each installed NICs. As such, Red Hat recommends that you ensure this parameter is defined in order to avoid any problems arising from an unexpected NIC enumeration.
In addition, to avoid any NIC enumeration changes after updating these HP Proliant models to Red Hat Enterprise Linux 4.7, add the kernel boot parameter pci=nobfsort to /boot/grub/grub.conf.
- BZ#232499
When a volume group contains a mirror or snapshot, issuing the lvchange command with a volume group parameter may result in the following error messages:
Unable to change mirror log LV fail_secondary_mlog directly
Unable to change mirror image LV fail_secondary_mimage_0 directly
Unable to change mirror image LV fail_secondary_mimage_1 directly
These messages can be safely ignored.
- BZ#441870
Dell PowerEdge SC1435s systems may hang during boot-up. To avoid this, edit the terminal line in grub.conf and replace the string serial console with console serial.
- BZ#456533
The updated ixgbe driver does not support the Intel 82598AT (Copper Pond 10GbE).
- BZ#454872
Red Hat Enterprise Linux 4.9 can detect online growing or shrinking of an underlying block device. However, there is no method to automatically detect that a device has changed size, so manual steps are required to recognize this and resize any file systems which reside on the given device(s). When a resized block device is detected, a message like the following will appear in the system logs:
VFS: busy inodes on changed media or resized disk sdi
If the block device was grown, then this message can be safely ignored. However, if the block device was shrunk without shrinking any data set on the block device first, the data residing on the device may be corrupted.
It is only possible to do an online resize of a filesystem that was created on the entire LUN (or block device). If there is a partition table on the block device, then the file system will have to be unmounted to update the partition table.
- BZ#479467
There is a known memory leak with the res_n* family of resolver routines (i.e. res_nquery, res_nsearch and res_nmkquery). Programs that use these functions will leak memory over time. It has been fixed in newer versions of glibc, however, the fix is too invasive to be applied to Red Hat Enterprise Linux 4. Programs that use these functions may need to be restarted occasionally to free memory.
- BZ#452513
The number of devices that can be handled during installation of Red Hat Enterprise Linux 4 depends on the size of the installation initrd image. Therefore, in situations where there are many devices attached to a machine (such as heavily populated Fibre Channel setups) installation will not be possible unless number of visible devices is reduced.
- BZ#492371
During installation anaconda may not remove all the Logical Volume Manager (LVM) metadata that exists on a system prior to installation. This extra metadata may cause LVM tools to report missing volume groups or logical volumes after installation. To work around this issue, remove the stale LVM metadata after the installation is complete.
- BZ#481190
multipath does not silence the error messages printed by any of it's callout programs. Therefore, if
multipath is run when paths are down, various error messages may be displayed. The messages that are displayed depend on the specific callout programs that
multipath is using. For example, if
multipath is run while there are failed scsi devices,
scsi_id will print
lt;H>:<B>:<T>:<L>:Unable to get INQUIRY vpd 1 page 0x0.
lt;H>:<B>:<T>:<L>:sg_io failed status 0x0 0x1 0x0 0x0
Or, if
multipath -ll is run while an
EMC CLARiiON is down, the
mpath_prio_emc priority callout will print
query command indicates error