Questo contenuto non è disponibile nella lingua selezionata.

Hardware accelerators


OpenShift Container Platform 4.18

Hardware accelerators

Red Hat OpenShift Documentation Team

Abstract

This document provides instructions for installing and configuring the GPU Operators supported by Red Hat OpenShift AI for the provided hardware acceleration capabilities for creating artificial intelligence and machine learning (AI/ML) applications.

Chapter 1. About hardware accelerators

Specialized hardware accelerators play a key role in the emerging generative artificial intelligence and machine learning (AI/ML) industry. Specifically, hardware accelerators are essential to the training and serving of large language and other foundational models that power this new technology. Data scientists, data engineers, ML engineers, and developers can take advantage of the specialized hardware acceleration for data-intensive transformations and model development and serving. Much of that ecosystem is open source, with several contributing partners and open source foundations.

Red Hat OpenShift Container Platform provides support for cards and peripheral hardware that add processing units that comprise hardware accelerators:

  • Graphical processing units (GPUs)
  • Neural processing units (NPUs)
  • Application-specific integrated circuits (ASICs)
  • Data processing units (DPUs)

Specialized hardware accelerators provide a rich set of benefits for AI/ML development:

One platform for all
A collaborative environment for developers, data engineers, data scientists, and DevOps
Extended capabilities with Operators
Operators allow for bringing AI/ML capabilities to OpenShift Container Platform
Hybrid-cloud support
On-premise support for model development, delivery, and deployment
Support for AI/ML workloads
Model testing, iteration, integration, promotion, and serving into production as services

Red Hat provides an optimized platform to enable these specialized hardware accelerators in Red Hat Enterprise Linux (RHEL) and OpenShift Container Platform platforms at the Linux (kernel and userspace) and Kubernetes layers. To do this, Red Hat combines the proven capabilities of Red Hat OpenShift AI and Red Hat OpenShift Container Platform in a single enterprise-ready AI application platform.

Hardware Operators use the operating framework of a Kubernetes cluster to enable the required accelerator resources. You can also deploy the provided device plugin manually or as a daemon set. This plugin registers the GPU in the cluster.

Certain specialized hardware accelerators are designed to work within disconnected environments where a secure environment must be maintained for development and testing.

1.1. Hardware accelerators

Red Hat OpenShift Container Platform enables the following hardware accelerators:

  • NVIDIA GPU
  • AMD Instinct® GPU
  • Intel® Gaudi®

Chapter 2. NVIDIA GPU architecture

NVIDIA supports the use of graphics processing unit (GPU) resources on OpenShift Container Platform. OpenShift Container Platform is a security-focused and hardened Kubernetes platform developed and supported by Red Hat for deploying and managing Kubernetes clusters at scale. OpenShift Container Platform includes enhancements to Kubernetes so that users can easily configure and use NVIDIA GPU resources to accelerate workloads.

The NVIDIA GPU Operator uses the Operator framework within OpenShift Container Platform to manage the full lifecycle of NVIDIA software components required to run GPU-accelerated workloads.

These components include the NVIDIA drivers (to enable CUDA), the Kubernetes device plugin for GPUs, the NVIDIA Container Toolkit, automatic node tagging using GPU feature discovery (GFD), DCGM-based monitoring, and others.

Note

The NVIDIA GPU Operator is only supported by NVIDIA. For more information about obtaining support from NVIDIA, see Obtaining Support from NVIDIA.

2.1. NVIDIA GPU prerequisites

  • A working OpenShift cluster with at least one GPU worker node.
  • Access to the OpenShift cluster as a cluster-admin to perform the required steps.
  • OpenShift CLI (oc) is installed.
  • The node feature discovery (NFD) Operator is installed and a nodefeaturediscovery instance is created.

2.2. NVIDIA GPU enablement

The following diagram shows how the GPU architecture is enabled for OpenShift:

Figure 2.1. NVIDIA GPU enablement

Note

MIG is supported on GPUs starting with the NVIDIA Ampere generation. For a list of GPUs that support MIG, see the NVIDIA MIG User Guide.

2.2.1. GPUs and bare metal

You can deploy OpenShift Container Platform on an NVIDIA-certified bare metal server but with some limitations:

  • Control plane nodes can be CPU nodes.
  • Worker nodes must be GPU nodes, provided that AI/ML workloads are executed on these worker nodes.

    In addition, the worker nodes can host one or more GPUs, but they must be of the same type. For example, a node can have two NVIDIA A100 GPUs, but a node with one A100 GPU and one T4 GPU is not supported. The NVIDIA Device Plugin for Kubernetes does not support mixing different GPU models on the same node.

  • When using OpenShift, note that one or three or more servers are required. Clusters with two servers are not supported. The single server deployment is called single node openShift (SNO) and using this configuration results in a non-high availability OpenShift environment.

You can choose one of the following methods to access the containerized GPUs:

  • GPU passthrough
  • Multi-Instance GPU (MIG)

2.2.2. GPUs and virtualization

Many developers and enterprises are moving to containerized applications and serverless infrastructures, but there is still a lot of interest in developing and maintaining applications that run on virtual machines (VMs). Red Hat OpenShift Virtualization provides this capability, enabling enterprises to incorporate VMs into containerized workflows within clusters.

You can choose one of the following methods to connect the worker nodes to the GPUs:

  • GPU passthrough to access and use GPU hardware within a virtual machine (VM).
  • GPU (vGPU) time-slicing, when GPU compute capacity is not saturated by workloads.

2.2.3. GPUs and vSphere

You can deploy OpenShift Container Platform on an NVIDIA-certified VMware vSphere server that can host different GPU types.

An NVIDIA GPU driver must be installed in the hypervisor in case vGPU instances are used by the VMs. For VMware vSphere, this host driver is provided in the form of a VIB file.

The maximum number of vGPUS that can be allocated to worker node VMs depends on the version of vSphere:

  • vSphere 7.0: maximum 4 vGPU per VM
  • vSphere 8.0: maximum 8 vGPU per VM

    Note

    vSphere 8.0 introduced support for multiple full or fractional heterogenous profiles associated with a VM.

You can choose one of the following methods to attach the worker nodes to the GPUs:

  • GPU passthrough for accessing and using GPU hardware within a virtual machine (VM)
  • GPU (vGPU) time-slicing, when not all of the GPU is needed

Similar to bare metal deployments, one or three or more servers are required. Clusters with two servers are not supported.

2.2.4. GPUs and Red Hat KVM

You can use OpenShift Container Platform on an NVIDIA-certified kernel-based virtual machine (KVM) server.

Similar to bare-metal deployments, one or three or more servers are required. Clusters with two servers are not supported.

However, unlike bare-metal deployments, you can use different types of GPUs in the server. This is because you can assign these GPUs to different VMs that act as Kubernetes nodes. The only limitation is that a Kubernetes node must have the same set of GPU types at its own level.

You can choose one of the following methods to access the containerized GPUs:

  • GPU passthrough for accessing and using GPU hardware within a virtual machine (VM)
  • GPU (vGPU) time-slicing when not all of the GPU is needed

To enable the vGPU capability, a special driver must be installed at the host level. This driver is delivered as a RPM package. This host driver is not required at all for GPU passthrough allocation.

2.2.5. GPUs and CSPs

You can deploy OpenShift Container Platform to one of the major cloud service providers (CSPs): Amazon Web Services (AWS), Google Cloud Platform (GCP), or Microsoft Azure.

Two modes of operation are available: a fully managed deployment and a self-managed deployment.

  • In a fully managed deployment, everything is automated by Red Hat in collaboration with CSP. You can request an OpenShift instance through the CSP web console, and the cluster is automatically created and fully managed by Red Hat. You do not have to worry about node failures or errors in the environment. Red Hat is fully responsible for maintaining the uptime of the cluster. The fully managed services are available on AWS, Azure, and GCP. For AWS, the OpenShift service is called ROSA (Red Hat OpenShift Service on AWS). For Azure, the service is called Azure Red Hat OpenShift. For GCP, the service is called OpenShift Dedicated on GCP.
  • In a self-managed deployment, you are responsible for instantiating and maintaining the OpenShift cluster. Red Hat provides the OpenShift-install utility to support the deployment of the OpenShift cluster in this case. The self-managed services are available globally to all CSPs.

It is important that this compute instance is a GPU-accelerated compute instance and that the GPU type matches the list of supported GPUs from NVIDIA AI Enterprise. For example, T4, V100, and A100 are part of this list.

You can choose one of the following methods to access the containerized GPUs:

  • GPU passthrough to access and use GPU hardware within a virtual machine (VM).
  • GPU (vGPU) time slicing when the entire GPU is not required.

2.2.6. GPUs and Red Hat Device Edge

Red Hat Device Edge provides access to MicroShift. MicroShift provides the simplicity of a single-node deployment with the functionality and services you need for resource-constrained (edge) computing. Red Hat Device Edge meets the needs of bare-metal, virtual, containerized, or Kubernetes workloads deployed in resource-constrained environments.

You can enable NVIDIA GPUs on containers in a Red Hat Device Edge environment.

You use GPU passthrough to access the containerized GPUs.

2.3. GPU sharing methods

Red Hat and NVIDIA have developed GPU concurrency and sharing mechanisms to simplify GPU-accelerated computing on an enterprise-level OpenShift Container Platform cluster.

Applications typically have different compute requirements that can leave GPUs underutilized. Providing the right amount of compute resources for each workload is critical to reduce deployment cost and maximize GPU utilization.

Concurrency mechanisms for improving GPU utilization exist that range from programming model APIs to system software and hardware partitioning, including virtualization. The following list shows the GPU concurrency mechanisms:

  • Compute Unified Device Architecture (CUDA) streams
  • Time-slicing
  • CUDA Multi-Process Service (MPS)
  • Multi-instance GPU (MIG)
  • Virtualization with vGPU

Consider the following GPU sharing suggestions when using the GPU concurrency mechanisms for different OpenShift Container Platform scenarios:

Bare metal
vGPU is not available. Consider using MIG-enabled cards.
VMs
vGPU is the best choice.
Older NVIDIA cards with no MIG on bare metal
Consider using time-slicing.
VMs with multiple GPUs and you want passthrough and vGPU
Consider using separate VMs.
Bare metal with OpenShift Virtualization and multiple GPUs
Consider using pass-through for hosted VMs and time-slicing for containers.

Additional resources

2.3.1. CUDA streams

Compute Unified Device Architecture (CUDA) is a parallel computing platform and programming model developed by NVIDIA for general computing on GPUs.

A stream is a sequence of operations that executes in issue-order on the GPU. CUDA commands are typically executed sequentially in a default stream and a task does not start until a preceding task has completed.

Asynchronous processing of operations across different streams allows for parallel execution of tasks. A task issued in one stream runs before, during, or after another task is issued into another stream. This allows the GPU to run multiple tasks simultaneously in no prescribed order, leading to improved performance.

Additional resources

2.3.2. Time-slicing

GPU time-slicing interleaves workloads scheduled on overloaded GPUs when you are running multiple CUDA applications.

You can enable time-slicing of GPUs on Kubernetes by defining a set of replicas for a GPU, each of which can be independently distributed to a pod to run workloads on. Unlike multi-instance GPU (MIG), there is no memory or fault isolation between replicas, but for some workloads this is better than not sharing at all. Internally, GPU time-slicing is used to multiplex workloads from replicas of the same underlying GPU.

You can apply a cluster-wide default configuration for time-slicing. You can also apply node-specific configurations. For example, you can apply a time-slicing configuration only to nodes with Tesla T4 GPUs and not modify nodes with other GPU models.

You can combine these two approaches by applying a cluster-wide default configuration and then labeling nodes to give those nodes a node-specific configuration.

2.3.3. CUDA Multi-Process Service

CUDA Multi-Process Service (MPS) allows a single GPU to use multiple CUDA processes. The processes run in parallel on the GPU, eliminating saturation of the GPU compute resources. MPS also enables concurrent execution, or overlapping, of kernel operations and memory copying from different processes to enhance utilization.

Additional resources

2.3.4. Multi-instance GPU

Using Multi-instance GPU (MIG), you can split GPU compute units and memory into multiple MIG instances. Each of these instances represents a standalone GPU device from a system perspective and can be connected to any application, container, or virtual machine running on the node. The software that uses the GPU treats each of these MIG instances as an individual GPU.

MIG is useful when you have an application that does not require the full power of an entire GPU. The MIG feature of the new NVIDIA Ampere architecture enables you to split your hardware resources into multiple GPU instances, each of which is available to the operating system as an independent CUDA-enabled GPU.

NVIDIA GPU Operator version 1.7.0 and higher provides MIG support for the A100 and A30 Ampere cards. These GPU instances are designed to support up to seven multiple independent CUDA applications so that they operate completely isolated with dedicated hardware resources.

2.3.5. Virtualization with vGPU

Virtual machines (VMs) can directly access a single physical GPU using NVIDIA vGPU. You can create virtual GPUs that can be shared by VMs across the enterprise and accessed by other devices.

This capability combines the power of GPU performance with the management and security benefits provided by vGPU. Additional benefits provided by vGPU includes proactive management and monitoring for your VM environment, workload balancing for mixed VDI and compute workloads, and resource sharing across multiple VMs.

Additional resources

2.4. NVIDIA GPU features for OpenShift Container Platform

NVIDIA Container Toolkit
NVIDIA Container Toolkit enables you to create and run GPU-accelerated containers. The toolkit includes a container runtime library and utilities to automatically configure containers to use NVIDIA GPUs.
NVIDIA AI Enterprise

NVIDIA AI Enterprise is an end-to-end, cloud-native suite of AI and data analytics software optimized, certified, and supported with NVIDIA-Certified systems.

NVIDIA AI Enterprise includes support for Red Hat OpenShift Container Platform. The following installation methods are supported:

  • OpenShift Container Platform on bare metal or VMware vSphere with GPU Passthrough.
  • OpenShift Container Platform on VMware vSphere with NVIDIA vGPU.
GPU Feature Discovery

NVIDIA GPU Feature Discovery for Kubernetes is a software component that enables you to automatically generate labels for the GPUs available on a node. GPU Feature Discovery uses node feature discovery (NFD) to perform this labeling.

The Node Feature Discovery Operator (NFD) manages the discovery of hardware features and configurations in an OpenShift Container Platform cluster by labeling nodes with hardware-specific information. NFD labels the host with node-specific attributes, such as PCI cards, kernel, OS version, and so on.

You can find the NFD Operator in the Operator Hub by searching for “Node Feature Discovery”.

NVIDIA GPU Operator with OpenShift Virtualization

Up until this point, the GPU Operator only provisioned worker nodes to run GPU-accelerated containers. Now, the GPU Operator can also be used to provision worker nodes for running GPU-accelerated virtual machines (VMs).

You can configure the GPU Operator to deploy different software components to worker nodes depending on which GPU workload is configured to run on those nodes.

GPU Monitoring dashboard
You can install a monitoring dashboard to display GPU usage information on the cluster Observe page in the OpenShift Container Platform web console. GPU utilization information includes the number of available GPUs, power consumption (in watts), temperature (in degrees Celsius), utilization (in percent), and other metrics for each GPU.

Chapter 3. AMD GPU Operator

AMD Instinct GPU accelerators combined with the AMD GPU Operator within your OpenShift Container Platform cluster lets you seamlessly harness computing capabilities for machine learning, Generative AI, and GPU-accelerated applications.

This documentation provides the information you need to enable, configure, and test the AMD GPU Operator. For more information, see AMD Instinct™ Accelerators.

3.1. About the AMD GPU Operator

The hardware acceleration capabilities of the AMD GPU Operator provide enhanced performance and cost efficiency for data scientists and developers using Red Hat OpenShift AI for creating artificial intelligence and machine learning (AI/ML) applications. Accelerating specific areas of GPU functions can minimize CPU processing and memory usage, improving overall application speed, memory consumption, and bandwidth restrictions.

3.2. Installing the AMD GPU Operator

As a cluster administrator, you can install the AMD GPU Operator by using the OpenShift CLI and the web console. This is a multi-step procedure that requires the installation of the Node Feature Discovery Operator, the Kernel Module Management Operator, and then the AMD GPU Operator. Use the following steps in succession to install the AMD community release of the Operator.

Next steps

  1. Install the Node Feature Discovery Operator.
  2. Install the Kernel Module Management Operator.
  3. Install and configure the AMD GPU Operator.

3.3. Testing the AMD GPU Operator

Use the following procedure to test the ROCmInfo installation and view the logs for the AMD MI210 GPU.

Procedure

  1. Create a YAML file that tests ROCmInfo:

    $ cat << EOF > rocminfo.yaml
    
    apiVersion: v1
    kind: Pod
    metadata:
     name: rocminfo
    spec:
     containers:
     - image: docker.io/rocm/pytorch:latest
       name: rocminfo
       command: ["/bin/sh","-c"]
       args: ["rocminfo"]
       resources:
        limits:
          amd.com/gpu: 1
        requests:
          amd.com/gpu: 1
     restartPolicy: Never
    EOF
    Copy to Clipboard Toggle word wrap
  2. Create the rocminfo pod:

    $ oc create -f rocminfo.yaml
    Copy to Clipboard Toggle word wrap

    Example output

    apiVersion: v1
    pod/rocminfo created
    Copy to Clipboard Toggle word wrap

  3. Check the rocmnfo log with one MI210 GPU:

    $ oc logs rocminfo | grep -A5 "Agent"
    Copy to Clipboard Toggle word wrap

    Example output

    HSA Agents
    ==========
    *******
    Agent 1
    *******
      Name:                    Intel(R) Xeon(R) Gold 6330 CPU @ 2.00GHz
      Uuid:                    CPU-XX
      Marketing Name:          Intel(R) Xeon(R) Gold 6330 CPU @ 2.00GHz
      Vendor Name:             CPU
    --
    Agent 2
    *******
      Name:                    Intel(R) Xeon(R) Gold 6330 CPU @ 2.00GHz
      Uuid:                    CPU-XX
      Marketing Name:          Intel(R) Xeon(R) Gold 6330 CPU @ 2.00GHz
      Vendor Name:             CPU
    --
    Agent 3
    *******
      Name:                    gfx90a
      Uuid:                    GPU-024b776f768a638b
      Marketing Name:          AMD Instinct MI210
      Vendor Name:             AMD
    Copy to Clipboard Toggle word wrap

  4. Delete the pod:

    $ oc delete -f rocminfo.yaml
    Copy to Clipboard Toggle word wrap

    Example output

    pod "rocminfo" deleted
    Copy to Clipboard Toggle word wrap

Chapter 4. Intel Gaudi AI accelerators

You can use Intel Gaudi AI accelerators for your OpenShift Container Platform generative AI and machine learning (AI/ML) applications. Intel Gaudi AI accelerators offer a cost-efficient, flexible, and scalable solution for optimized deep learning workloads.

Red Hat supports Intel Gaudi 2 and Intel Gaudi 3 devices. Intel Gaudi 3 devices provide significant improvements in training speed and energy efficiency.

4.1. Intel Gaudi AI accelerators prerequisites

  • You have a working OpenShift Container Platform cluster with at least one GPU worker node.
  • You have access to the OpenShift Container Platform cluster as a cluster-admin to perform the required steps.
  • You have installed OpenShift CLI (oc).
  • You have installed the Node Feature Discovery (NFD) Operator and created a NodeFeatureDiscovery instance.

Chapter 5. NVIDIA GPUDirect Remote Direct Memory Access (RDMA)

NVIDIA GPUDirect Remote Direct Memory Access (RDMA) allows for an application in one computer to directly access the memory of another computer without needing access through the operating system. This provides the ability to bypass kernel intervention in the process, freeing up resources and greatly reducing the CPU overhead normally needed to process network communications. This is useful for distributing GPU-accelerated workloads across clusters. And because RDMA is so suited toward high bandwidth and low latency applications, this makes it ideal for big data and machine learning applications.

There are currently three configuration methods for NVIDIA GPUDirect RDMA:

Shared device
This method allows for an NVIDIA GPUDirect RDMA device to be shared among multiple pods on the OpenShift Container Platform worker node where the device is exposed.
Host device
This method provides direct physical Ethernet access on the worker node by creating an additional host network on a pod. A plugin allows the network device to be moved from the host network namespace to the network namespace on the pod.
SR-IOV legacy device
The Single Root IO Virtualization (SR-IOV) method can share a single network device, such as an Ethernet adapter, with multiple pods. SR-IOV segments the device, recognized on the host node as a physical function (PF), into multiple virtual functions (VFs). The VF is used like any other network device.

Each of these methods can be used across either the NVIDIA GPUDirect RDMA over Converged Ethernet (RoCE) or Infiniband infrastructures, providing an aggregate total of six methods of configuration.

5.1. NVIDIA GPUDirect RDMA prerequisites

All methods of NVIDIA GPUDirect RDMA configuration require the installation of specific Operators. Use the following steps to install the Operators:

5.2. Disabling the IRDMA kernel module

On some systems, including the DellR750xa, the IRDMA kernel module creates problems for the NVIDIA Network Operator when unloading and loading the DOCA drivers. Use the following procedure to disable the module.

Procedure

  1. Generate the following machine configuration file by running the following command:

    $ cat <<EOF > 99-machine-config-blacklist-irdma.yaml
    Copy to Clipboard Toggle word wrap

    Example output

    apiVersion: machineconfiguration.openshift.io/v1
    kind: MachineConfig
    metadata:
      labels:
        machineconfiguration.openshift.io/role: worker
      name: 99-worker-blacklist-irdma
    spec:
      kernelArguments:
        - "module_blacklist=irdma"
    Copy to Clipboard Toggle word wrap

  2. Create the machine configuration on the cluster and wait for the nodes to reboot by running the following command:

    $ oc create -f 99-machine-config-blacklist-irdma.yaml
    Copy to Clipboard Toggle word wrap

    Example output

    machineconfig.machineconfiguration.openshift.io/99-worker-blacklist-irdma created
    Copy to Clipboard Toggle word wrap

  3. Validate in a debug pod on each node that the module has not loaded by running the following command:

    $ oc debug node/nvd-srv-32.nvidia.eng.rdu2.dc.redhat.com
    Starting pod/nvd-srv-32nvidiaengrdu2dcredhatcom-debug-btfj2 ...
    To use host binaries, run `chroot /host`
    Pod IP: 10.6.135.11
    If you don't see a command prompt, try pressing enter.
    sh-5.1# chroot /host
    sh-5.1# lsmod|grep irdma
    sh-5.1#
    Copy to Clipboard Toggle word wrap

5.3. Creating persistent naming rules

In some cases, device names won’t persist following a reboot. For example, on R760xa systems Mellanox devices might be renamed after a reboot. You can avoid this problem by using a MachineConfig to set persistence.

Procedure

  1. Gather the MAC address names from the worker nodes for the node into a file and provide names for the interfaces that need to persist. This example uses the file 70-persistent-net.rules and stashes the details in it.

    $ cat <<EOF > 70-persistent-net.rules
    SUBSYSTEM=="net",ACTION=="add",ATTR{address}=="b8:3f:d2:3b:51:28",ATTR{type}=="1",NAME="ibs2f0"
    SUBSYSTEM=="net",ACTION=="add",ATTR{address}=="b8:3f:d2:3b:51:29",ATTR{type}=="1",NAME="ens8f0np0"
    SUBSYSTEM=="net",ACTION=="add",ATTR{address}=="b8:3f:d2:f0:36:d0",ATTR{type}=="1",NAME="ibs2f0"
    SUBSYSTEM=="net",ACTION=="add",ATTR{address}=="b8:3f:d2:f0:36:d1",ATTR{type}=="1",NAME="ens8f0np0"
    EOF
    Copy to Clipboard Toggle word wrap
  2. Convert that file into a base64 string without line breaks and set the output to the variable PERSIST:

    $ PERSIST=`cat 70-persistent-net.rules| base64 -w 0`
    
    $ echo $PERSIST
    U1VCU1lTVEVNPT0ibmV0IixBQ1RJT049PSJhZGQiLEFUVFJ7YWRkcmVzc309PSJiODozZjpkMjozYjo1MToyOCIsQVRUUnt0eXBlfT09IjEiLE5BTUU9ImliczJmMCIKU1VCU1lTVEVNPT0ibmV0IixBQ1RJT049PSJhZGQiLEFUVFJ7YWRkcmVzc309PSJiODozZjpkMjozYjo1MToyOSIsQVRUUnt0eXBlfT09IjEiLE5BTUU9ImVuczhmMG5wMCIKU1VCU1lTVEVNPT0ibmV0IixBQ1RJT049PSJhZGQiLEFUVFJ7YWRkcmVzc309PSJiODozZjpkMjpmMDozNjpkMCIsQVRUUnt0eXBlfT09IjEiLE5BTUU9ImliczJmMCIKU1VCU1lTVEVNPT0ibmV0IixBQ1RJT049PSJhZGQiLEFUVFJ7YWRkcmVzc309PSJiODozZjpkMjpmMDozNjpkMSIsQVRUUnt0eXBlfT09IjEiLE5BTUU9ImVuczhmMG5wMCIK
    Copy to Clipboard Toggle word wrap
  3. Create a machine configuration and set the base64 encoding in the custom resource file by running the following command:

    $ cat <<EOF > 99-machine-config-udev-network.yaml
    Copy to Clipboard Toggle word wrap
    apiVersion: machineconfiguration.openshift.io/v1
    kind: MachineConfig
    metadata:
       labels:
         machineconfiguration.openshift.io/role: worker
       name: 99-machine-config-udev-network
    spec:
       config:
         ignition:
           version: 3.2.0
         storage:
           files:
           - contents:
               source: data:text/plain;base64,$PERSIST
             filesystem: root
             mode: 420
             path: /etc/udev/rules.d/70-persistent-net.rules
    Copy to Clipboard Toggle word wrap
  4. Create the machine configuration on the cluster by running the following command:

    $ oc create -f 99-machine-config-udev-network.yaml
    Copy to Clipboard Toggle word wrap

    Example output

    machineconfig.machineconfiguration.openshift.io/99-machine-config-udev-network created
    Copy to Clipboard Toggle word wrap

  5. Use the get mcp command to view the machine configuration status:

    $ oc get mcp
    Copy to Clipboard Toggle word wrap

    Example output

    NAME     CONFIG                                             UPDATED   UPDATING   DEGRADED   MACHINECOUNT   READYMACHINECOUNT   UPDATEDMACHINECOUNT   DEGRADEDMACHINECOUNT   AGE
    master   rendered-master-9adfe851c2c14d9598eea5ec3df6c187   True      False      False      1              1                   1                     0                      6h21m
    worker   rendered-worker-4568f1b174066b4b1a4de794cf538fee   False     True       False      2              0                   0                     0                      6h21m
    Copy to Clipboard Toggle word wrap

The nodes will reboot and when the updating field returns to false, you can validate on the nodes by looking at the devices in a debug pod.

5.4. Configuring the NFD Operator

The Node Feature Discovery (NFD) Operator manages the detection of hardware features and configuration in an OpenShift Container Platform cluster by labeling the nodes with hardware-specific information. NFD labels the host with node-specific attributes, such as PCI cards, kernel, operating system version, and so on.

Prerequisites

  • You have installed the NFD Operator.

Procedure

  1. Validate that the Operator is installed and running by looking at the pods in the openshift-nfd namespace by running the following command:

    $ oc get pods -n openshift-nfd
    Copy to Clipboard Toggle word wrap

    Example output

    NAME                                      READY   STATUS    RESTARTS   AGE
    nfd-controller-manager-8698c88cdd-t8gbc   2/2     Running   0          2m
    Copy to Clipboard Toggle word wrap

  2. With the NFD controller running, generate the NodeFeatureDiscovery instance and add it to the cluster.

    The ClusterServiceVersion specification for NFD Operator provides default values, including the NFD operand image that is part of the Operator payload. Retrieve its value by running the following command:

    $ NFD_OPERAND_IMAGE=`echo $(oc get csv -n openshift-nfd -o json | jq -r '.items[0].metadata.annotations["alm-examples"]') | jq -r '.[] | select(.kind == "NodeFeatureDiscovery") | .spec.operand.image'`
    Copy to Clipboard Toggle word wrap
  3. Optional: Add entries to the default deviceClassWhiteList field, to support more network adapters, such as the NVIDIA BlueField DPUs.

    apiVersion: nfd.openshift.io/v1
    kind: NodeFeatureDiscovery
    metadata:
      name: nfd-instance
      namespace: openshift-nfd
    spec:
      instance: ''
      operand:
        image: '${NFD_OPERAND_IMAGE}'
        servicePort: 12000
      prunerOnDelete: false
      topologyUpdater: false
      workerConfig:
        configData: |
          core:
            sleepInterval: 60s
          sources:
            pci:
              deviceClassWhitelist:
                - "02"
                - "03"
                - "0200"
                - "0207"
                - "12"
              deviceLabelFields:
                - "vendor"
    Copy to Clipboard Toggle word wrap
  4. Create the 'NodeFeatureDiscovery` instance by running the following command:

    $ oc create -f nfd-instance.yaml
    Copy to Clipboard Toggle word wrap

    Example output

    nodefeaturediscovery.nfd.openshift.io/nfd-instance created
    Copy to Clipboard Toggle word wrap

  5. Validate that the instance is up and running by looking at the pods under the openshift-nfd namespace by running the following command:

    $ oc get pods -n openshift-nfd
    Copy to Clipboard Toggle word wrap

    Example output

    NAME                                    READY   STATUS    RESTARTS   AGE
    nfd-controller-manager-7cb6d656-jcnqb   2/2     Running   0          4m
    nfd-gc-7576d64889-s28k9                 1/1     Running   0          21s
    nfd-master-b7bcf5cfd-qnrmz              1/1     Running   0          21s
    nfd-worker-96pfh                        1/1     Running   0          21s
    nfd-worker-b2gkg                        1/1     Running   0          21s
    nfd-worker-bd9bk                        1/1     Running   0          21s
    nfd-worker-cswf4                        1/1     Running   0          21s
    nfd-worker-kp6gg                        1/1     Running   0          21s
    Copy to Clipboard Toggle word wrap

  6. Wait a short period of time and then verify that NFD has added labels to the node. The NFD labels are prefixed with feature.node.kubernetes.io, so you can easily filter them.

    $ oc get node -o json | jq '.items[0].metadata.labels | with_entries(select(.key | startswith("feature.node.kubernetes.io")))'
    {
      "feature.node.kubernetes.io/cpu-cpuid.ADX": "true",
      "feature.node.kubernetes.io/cpu-cpuid.AESNI": "true",
      "feature.node.kubernetes.io/cpu-cpuid.AVX": "true",
      "feature.node.kubernetes.io/cpu-cpuid.AVX2": "true",
      "feature.node.kubernetes.io/cpu-cpuid.CETSS": "true",
      "feature.node.kubernetes.io/cpu-cpuid.CLZERO": "true",
      "feature.node.kubernetes.io/cpu-cpuid.CMPXCHG8": "true",
      "feature.node.kubernetes.io/cpu-cpuid.CPBOOST": "true",
      "feature.node.kubernetes.io/cpu-cpuid.EFER_LMSLE_UNS": "true",
      "feature.node.kubernetes.io/cpu-cpuid.FMA3": "true",
      "feature.node.kubernetes.io/cpu-cpuid.FP256": "true",
      "feature.node.kubernetes.io/cpu-cpuid.FSRM": "true",
      "feature.node.kubernetes.io/cpu-cpuid.FXSR": "true",
      "feature.node.kubernetes.io/cpu-cpuid.FXSROPT": "true",
      "feature.node.kubernetes.io/cpu-cpuid.IBPB": "true",
      "feature.node.kubernetes.io/cpu-cpuid.IBRS": "true",
      "feature.node.kubernetes.io/cpu-cpuid.IBRS_PREFERRED": "true",
      "feature.node.kubernetes.io/cpu-cpuid.IBRS_PROVIDES_SMP": "true",
      "feature.node.kubernetes.io/cpu-cpuid.IBS": "true",
      "feature.node.kubernetes.io/cpu-cpuid.IBSBRNTRGT": "true",
      "feature.node.kubernetes.io/cpu-cpuid.IBSFETCHSAM": "true",
      "feature.node.kubernetes.io/cpu-cpuid.IBSFFV": "true",
      "feature.node.kubernetes.io/cpu-cpuid.IBSOPCNT": "true",
      "feature.node.kubernetes.io/cpu-cpuid.IBSOPCNTEXT": "true",
      "feature.node.kubernetes.io/cpu-cpuid.IBSOPSAM": "true",
      "feature.node.kubernetes.io/cpu-cpuid.IBSRDWROPCNT": "true",
      "feature.node.kubernetes.io/cpu-cpuid.IBSRIPINVALIDCHK": "true",
      "feature.node.kubernetes.io/cpu-cpuid.IBS_FETCH_CTLX": "true",
      "feature.node.kubernetes.io/cpu-cpuid.IBS_OPFUSE": "true",
      "feature.node.kubernetes.io/cpu-cpuid.IBS_PREVENTHOST": "true",
      "feature.node.kubernetes.io/cpu-cpuid.INT_WBINVD": "true",
      "feature.node.kubernetes.io/cpu-cpuid.INVLPGB": "true",
      "feature.node.kubernetes.io/cpu-cpuid.LAHF": "true",
      "feature.node.kubernetes.io/cpu-cpuid.LBRVIRT": "true",
      "feature.node.kubernetes.io/cpu-cpuid.MCAOVERFLOW": "true",
      "feature.node.kubernetes.io/cpu-cpuid.MCOMMIT": "true",
      "feature.node.kubernetes.io/cpu-cpuid.MOVBE": "true",
      "feature.node.kubernetes.io/cpu-cpuid.MOVU": "true",
      "feature.node.kubernetes.io/cpu-cpuid.MSRIRC": "true",
      "feature.node.kubernetes.io/cpu-cpuid.MSR_PAGEFLUSH": "true",
      "feature.node.kubernetes.io/cpu-cpuid.NRIPS": "true",
      "feature.node.kubernetes.io/cpu-cpuid.OSXSAVE": "true",
      "feature.node.kubernetes.io/cpu-cpuid.PPIN": "true",
      "feature.node.kubernetes.io/cpu-cpuid.PSFD": "true",
      "feature.node.kubernetes.io/cpu-cpuid.RDPRU": "true",
      "feature.node.kubernetes.io/cpu-cpuid.SEV": "true",
      "feature.node.kubernetes.io/cpu-cpuid.SEV_64BIT": "true",
      "feature.node.kubernetes.io/cpu-cpuid.SEV_ALTERNATIVE": "true",
      "feature.node.kubernetes.io/cpu-cpuid.SEV_DEBUGSWAP": "true",
      "feature.node.kubernetes.io/cpu-cpuid.SEV_ES": "true",
      "feature.node.kubernetes.io/cpu-cpuid.SEV_RESTRICTED": "true",
      "feature.node.kubernetes.io/cpu-cpuid.SEV_SNP": "true",
      "feature.node.kubernetes.io/cpu-cpuid.SHA": "true",
      "feature.node.kubernetes.io/cpu-cpuid.SME": "true",
      "feature.node.kubernetes.io/cpu-cpuid.SME_COHERENT": "true",
      "feature.node.kubernetes.io/cpu-cpuid.SPEC_CTRL_SSBD": "true",
      "feature.node.kubernetes.io/cpu-cpuid.SSE4A": "true",
      "feature.node.kubernetes.io/cpu-cpuid.STIBP": "true",
      "feature.node.kubernetes.io/cpu-cpuid.STIBP_ALWAYSON": "true",
      "feature.node.kubernetes.io/cpu-cpuid.SUCCOR": "true",
      "feature.node.kubernetes.io/cpu-cpuid.SVM": "true",
      "feature.node.kubernetes.io/cpu-cpuid.SVMDA": "true",
      "feature.node.kubernetes.io/cpu-cpuid.SVMFBASID": "true",
      "feature.node.kubernetes.io/cpu-cpuid.SVML": "true",
      "feature.node.kubernetes.io/cpu-cpuid.SVMNP": "true",
      "feature.node.kubernetes.io/cpu-cpuid.SVMPF": "true",
      "feature.node.kubernetes.io/cpu-cpuid.SVMPFT": "true",
      "feature.node.kubernetes.io/cpu-cpuid.SYSCALL": "true",
      "feature.node.kubernetes.io/cpu-cpuid.SYSEE": "true",
      "feature.node.kubernetes.io/cpu-cpuid.TLB_FLUSH_NESTED": "true",
      "feature.node.kubernetes.io/cpu-cpuid.TOPEXT": "true",
      "feature.node.kubernetes.io/cpu-cpuid.TSCRATEMSR": "true",
      "feature.node.kubernetes.io/cpu-cpuid.VAES": "true",
      "feature.node.kubernetes.io/cpu-cpuid.VMCBCLEAN": "true",
      "feature.node.kubernetes.io/cpu-cpuid.VMPL": "true",
      "feature.node.kubernetes.io/cpu-cpuid.VMSA_REGPROT": "true",
      "feature.node.kubernetes.io/cpu-cpuid.VPCLMULQDQ": "true",
      "feature.node.kubernetes.io/cpu-cpuid.VTE": "true",
      "feature.node.kubernetes.io/cpu-cpuid.WBNOINVD": "true",
      "feature.node.kubernetes.io/cpu-cpuid.X87": "true",
      "feature.node.kubernetes.io/cpu-cpuid.XGETBV1": "true",
      "feature.node.kubernetes.io/cpu-cpuid.XSAVE": "true",
      "feature.node.kubernetes.io/cpu-cpuid.XSAVEC": "true",
      "feature.node.kubernetes.io/cpu-cpuid.XSAVEOPT": "true",
      "feature.node.kubernetes.io/cpu-cpuid.XSAVES": "true",
      "feature.node.kubernetes.io/cpu-hardware_multithreading": "false",
      "feature.node.kubernetes.io/cpu-model.family": "25",
      "feature.node.kubernetes.io/cpu-model.id": "1",
      "feature.node.kubernetes.io/cpu-model.vendor_id": "AMD",
      "feature.node.kubernetes.io/kernel-config.NO_HZ": "true",
      "feature.node.kubernetes.io/kernel-config.NO_HZ_FULL": "true",
      "feature.node.kubernetes.io/kernel-selinux.enabled": "true",
      "feature.node.kubernetes.io/kernel-version.full": "5.14.0-427.35.1.el9_4.x86_64",
      "feature.node.kubernetes.io/kernel-version.major": "5",
      "feature.node.kubernetes.io/kernel-version.minor": "14",
      "feature.node.kubernetes.io/kernel-version.revision": "0",
      "feature.node.kubernetes.io/memory-numa": "true",
      "feature.node.kubernetes.io/network-sriov.capable": "true",
      "feature.node.kubernetes.io/pci-102b.present": "true",
      "feature.node.kubernetes.io/pci-10de.present": "true",
      "feature.node.kubernetes.io/pci-10de.sriov.capable": "true",
      "feature.node.kubernetes.io/pci-15b3.present": "true",
      "feature.node.kubernetes.io/pci-15b3.sriov.capable": "true",
      "feature.node.kubernetes.io/rdma.available": "true",
      "feature.node.kubernetes.io/rdma.capable": "true",
      "feature.node.kubernetes.io/storage-nonrotationaldisk": "true",
      "feature.node.kubernetes.io/system-os_release.ID": "rhcos",
      "feature.node.kubernetes.io/system-os_release.OPENSHIFT_VERSION": "4.17",
      "feature.node.kubernetes.io/system-os_release.OSTREE_VERSION": "417.94.202409121747-0",
      "feature.node.kubernetes.io/system-os_release.RHEL_VERSION": "9.4",
      "feature.node.kubernetes.io/system-os_release.VERSION_ID": "4.17",
      "feature.node.kubernetes.io/system-os_release.VERSION_ID.major": "4",
      "feature.node.kubernetes.io/system-os_release.VERSION_ID.minor": "17"
    }
    Copy to Clipboard Toggle word wrap
  7. Confirm there is a network device that is discovered:

    $ oc describe node | grep -E 'Roles|pci' | grep pci-15b3
                        feature.node.kubernetes.io/pci-15b3.present=true
                        feature.node.kubernetes.io/pci-15b3.sriov.capable=true
                        feature.node.kubernetes.io/pci-15b3.present=true
                        feature.node.kubernetes.io/pci-15b3.sriov.capable=true
    Copy to Clipboard Toggle word wrap

5.5. Configuring the SR-IOV Operator

Single root I/O virtualization (SR-IOV) enhances the performance of NVIDIA GPUDirect RDMA by providing sharing across multiple pods from a single device.

Prerequisites

  • You have installed the SR-IOV Operator.

Procedure

  1. Validate that the Operator is installed and running by looking at the pods in the openshift-sriov-network-operator namespace by running the following command:

    $ oc get pods -n openshift-sriov-network-operator
    Copy to Clipboard Toggle word wrap

    Example output

    NAME                                      READY   STATUS    RESTARTS   AGE
    sriov-network-operator-7cb6c49868-89486   1/1     Running   0          22s
    Copy to Clipboard Toggle word wrap

  2. For the default SriovOperatorConfig CR to work with the MLNX_OFED container, run this command to update the following values:

    apiVersion: sriovnetwork.openshift.io/v1
    kind: SriovOperatorConfig
    metadata:
      name: default
      namespace: openshift-sriov-network-operator
    spec:
      enableInjector: true
      enableOperatorWebhook: true
      logLevel: 2
    Copy to Clipboard Toggle word wrap
  3. Create the resource on the cluster by running the following command:

    $ oc create -f sriov-operator-config.yaml
    Copy to Clipboard Toggle word wrap

    Example output

    sriovoperatorconfig.sriovnetwork.openshift.io/default created
    Copy to Clipboard Toggle word wrap

  4. Patch the sriov-operator so the MOFED container can work with it by running the following command:

    $ oc patch sriovoperatorconfig default   --type=merge -n openshift-sriov-network-operator   --patch '{ "spec": { "configDaemonNodeSelector": { "network.nvidia.com/operator.mofed.wait": "false", "node-role.kubernetes.io/worker": "", "feature.node.kubernetes.io/pci-15b3.sriov.capable": "true" } } }'
    Copy to Clipboard Toggle word wrap

    Example output

    sriovoperatorconfig.sriovnetwork.openshift.io/default patched
    Copy to Clipboard Toggle word wrap

5.6. Configuring the NVIDIA network Operator

The NVIDIA network Operator manages NVIDIA networking resources and networking related components such as drivers and device plugins to enable NVIDIA GPUDirect RDMA workloads.

Prerequisites

  • You have installed the NVIDIA network Operator.

Procedure

  1. Validate that the network Operator is installed and running by confirming the controller is running in the nvidia-network-operator namespace by running the following command:

    $ oc get pods -n nvidia-network-operator
    Copy to Clipboard Toggle word wrap

    Example output

    NAME                                                          READY   STATUS             RESTARTS        AGE
    nvidia-network-operator-controller-manager-6f7d6956cd-fw5wg   1/1     Running            0                5m
    Copy to Clipboard Toggle word wrap

  2. With the Operator running, create the NicClusterPolicy custom resource file. The device you choose depends on your system configuration. In this example, the Infiniband interface ibs2f0 is hard coded and is used as the shared NVIDIA GPUDirect RDMA device.

    apiVersion: mellanox.com/v1alpha1
    kind: NicClusterPolicy
    metadata:
      name: nic-cluster-policy
    spec:
      nicFeatureDiscovery:
        image: nic-feature-discovery
        repository: ghcr.io/mellanox
        version: v0.0.1
      docaTelemetryService:
        image: doca_telemetry
        repository: nvcr.io/nvidia/doca
        version: 1.16.5-doca2.6.0-host
      rdmaSharedDevicePlugin:
        config: |
          {
            "configList": [
              {
                "resourceName": "rdma_shared_device_ib",
                "rdmaHcaMax": 63,
                "selectors": {
                  "ifNames": ["ibs2f0"]
                }
              },
              {
                "resourceName": "rdma_shared_device_eth",
                "rdmaHcaMax": 63,
                "selectors": {
                  "ifNames": ["ens8f0np0"]
                }
              }
            ]
          }
        image: k8s-rdma-shared-dev-plugin
        repository: ghcr.io/mellanox
        version: v1.5.1
      secondaryNetwork:
        ipoib:
          image: ipoib-cni
          repository: ghcr.io/mellanox
          version: v1.2.0
      nvIpam:
        enableWebhook: false
        image: nvidia-k8s-ipam
        repository: ghcr.io/mellanox
        version: v0.2.0
      ofedDriver:
        readinessProbe:
          initialDelaySeconds: 10
          periodSeconds: 30
        forcePrecompiled: false
        terminationGracePeriodSeconds: 300
        livenessProbe:
          initialDelaySeconds: 30
          periodSeconds: 30
        upgradePolicy:
          autoUpgrade: true
          drain:
            deleteEmptyDir: true
            enable: true
            force: true
            timeoutSeconds: 300
            podSelector: ''
          maxParallelUpgrades: 1
          safeLoad: false
          waitForCompletion:
            timeoutSeconds: 0
        startupProbe:
          initialDelaySeconds: 10
          periodSeconds: 20
        image: doca-driver
        repository: nvcr.io/nvidia/mellanox
        version: 24.10-0.7.0.0-0
        env:
        - name: UNLOAD_STORAGE_MODULES
          value: "true"
        - name: RESTORE_DRIVER_ON_POD_TERMINATION
          value: "true"
        - name: CREATE_IFNAMES_UDEV
          value: "true"
    Copy to Clipboard Toggle word wrap
  3. Create the NicClusterPolicy custom resource on the cluster by running the following command:

    $ oc create -f network-sharedrdma-nic-cluster-policy.yaml
    Copy to Clipboard Toggle word wrap

    Example output

    nicclusterpolicy.mellanox.com/nic-cluster-policy created
    Copy to Clipboard Toggle word wrap

  4. Validate the NicClusterPolicy by running the following command in the DOCA/MOFED container:

    $ oc get pods -n nvidia-network-operator
    Copy to Clipboard Toggle word wrap

    Example output

    NAME                                                          READY   STATUS    RESTARTS   AGE
    doca-telemetry-service-hwj65                                  1/1     Running   2          160m
    kube-ipoib-cni-ds-fsn8g                                       1/1     Running   2          160m
    mofed-rhcos4.16-9b5ddf4c6-ds-ct2h5                            2/2     Running   4          160m
    nic-feature-discovery-ds-dtksz                                1/1     Running   2          160m
    nv-ipam-controller-854585f594-c5jpp                           1/1     Running   2          160m
    nv-ipam-controller-854585f594-xrnp5                           1/1     Running   2          160m
    nv-ipam-node-xqttl                                            1/1     Running   2          160m
    nvidia-network-operator-controller-manager-5798b564cd-5cq99   1/1     Running   2         5d23h
    rdma-shared-dp-ds-p9vvg                                       1/1     Running   0          85m
    Copy to Clipboard Toggle word wrap

  5. rsh into the mofed container to check the status by running the following command:

    $ MOFED_POD=$(oc get pods -n nvidia-network-operator -o name | grep mofed)
    $ oc rsh -n nvidia-network-operator -c mofed-container ${MOFED_POD}
    sh-5.1# ofed_info -s
    Copy to Clipboard Toggle word wrap

    Example output

    OFED-internal-24.07-0.6.1:
    Copy to Clipboard Toggle word wrap

    sh-5.1# ibdev2netdev -v
    Copy to Clipboard Toggle word wrap

    Example output

    0000:0d:00.0 mlx5_0 (MT41692 - 900-9D3B4-00EN-EA0) BlueField-3 E-series SuperNIC 400GbE/NDR single port QSFP112, PCIe Gen5.0 x16 FHHL, Crypto Enabled, 16GB DDR5, BMC, Tall Bracket                                                       fw 32.42.1000 port 1 (ACTIVE) ==> ibs2f0 (Up)
    0000:a0:00.0 mlx5_1 (MT41692 - 900-9D3B4-00EN-EA0) BlueField-3 E-series SuperNIC 400GbE/NDR single port QSFP112, PCIe Gen5.0 x16 FHHL, Crypto Enabled, 16GB DDR5, BMC, Tall Bracket                                                       fw 32.42.1000 port 1 (ACTIVE) ==> ens8f0np0 (Up)
    Copy to Clipboard Toggle word wrap

  6. Create a IPoIBNetwork custom resource file:

    apiVersion: mellanox.com/v1alpha1
    kind: IPoIBNetwork
    metadata:
      name: example-ipoibnetwork
    spec:
      ipam: |
        {
          "type": "whereabouts",
          "range": "192.168.6.225/28",
          "exclude": [
           "192.168.6.229/30",
           "192.168.6.236/32"
          ]
        }
      master: ibs2f0
      networkNamespace: default
    Copy to Clipboard Toggle word wrap
  7. Create the IPoIBNetwork resource on the cluster by running the following command:

    $ oc create -f ipoib-network.yaml
    Copy to Clipboard Toggle word wrap

    Example output

    ipoibnetwork.mellanox.com/example-ipoibnetwork created
    Copy to Clipboard Toggle word wrap

  8. Create a MacvlanNetwork custom resource file for your other interface:

    apiVersion: mellanox.com/v1alpha1
    kind: MacvlanNetwork
    metadata:
      name: rdmashared-net
    spec:
      networkNamespace: default
      master: ens8f0np0
      mode: bridge
      mtu: 1500
      ipam: '{"type": "whereabouts", "range": "192.168.2.0/24", "gateway": "192.168.2.1"}'
    Copy to Clipboard Toggle word wrap
  9. Create the resource on the cluster by running the following command:

    $ oc create -f macvlan-network.yaml
    Copy to Clipboard Toggle word wrap

    Example output

    macvlannetwork.mellanox.com/rdmashared-net created
    Copy to Clipboard Toggle word wrap

5.7. Configuring the GPU Operator

The GPU Operator automates the management of the NVIDIA drivers, device plugins for GPUs, the NVIDIA Container Toolkit, and other components required for GPU provisioning.

Prerequisites

  • You have installed the GPU Operator.

Procedure

  1. Check that the Operator pod is running to look at the pods under the namespace by running the following command:

    $ oc get pods -n nvidia-gpu-operator
    Copy to Clipboard Toggle word wrap

    Example output

    NAME                          READY   STATUS    RESTARTS   AGE
    gpu-operator-b4cb7d74-zxpwq   1/1     Running   0          32s
    Copy to Clipboard Toggle word wrap

  2. Create a GPU cluster policy custom resource file similar to the following example:

    apiVersion: nvidia.com/v1
    kind: ClusterPolicy
    metadata:
      name: gpu-cluster-policy
    spec:
      vgpuDeviceManager:
        config:
          default: default
        enabled: true
      migManager:
        config:
          default: all-disabled
          name: default-mig-parted-config
        enabled: true
      operator:
        defaultRuntime: crio
        initContainer: {}
        runtimeClass: nvidia
        use_ocp_driver_toolkit: true
      dcgm:
        enabled: true
      gfd:
        enabled: true
      dcgmExporter:
        config:
          name: ''
        serviceMonitor:
          enabled: true
        enabled: true
      cdi:
        default: false
        enabled: false
      driver:
        licensingConfig:
          nlsEnabled: true
          configMapName: ''
        certConfig:
          name: ''
        rdma:
          enabled: false
        kernelModuleConfig:
          name: ''
        upgradePolicy:
          autoUpgrade: true
          drain:
            deleteEmptyDir: false
            enable: false
            force: false
            timeoutSeconds: 300
          maxParallelUpgrades: 1
          maxUnavailable: 25%
          podDeletion:
            deleteEmptyDir: false
            force: false
            timeoutSeconds: 300
          waitForCompletion:
            timeoutSeconds: 0
        repoConfig:
          configMapName: ''
        virtualTopology:
          config: ''
        enabled: true
        useNvidiaDriverCRD: false
        useOpenKernelModules: true
      devicePlugin:
        config:
          name: ''
          default: ''
        mps:
          root: /run/nvidia/mps
        enabled: true
      gdrcopy:
        enabled: true
      kataManager:
        config:
          artifactsDir: /opt/nvidia-gpu-operator/artifacts/runtimeclasses
      mig:
        strategy: single
      sandboxDevicePlugin:
        enabled: true
      validator:
        plugin:
          env:
            - name: WITH_WORKLOAD
              value: 'false'
      nodeStatusExporter:
        enabled: true
      daemonsets:
        rollingUpdate:
          maxUnavailable: '1'
        updateStrategy: RollingUpdate
      sandboxWorkloads:
        defaultWorkload: container
        enabled: false
      gds:
        enabled: true
        image: nvidia-fs
        version: 2.20.5
        repository: nvcr.io/nvidia/cloud-native
      vgpuManager:
        enabled: false
      vfioManager:
        enabled: true
      toolkit:
        installDir: /usr/local/nvidia
        enabled: true
    Copy to Clipboard Toggle word wrap
  3. When the GPU ClusterPolicy custom resource has generated, create the resource on the cluster by running the following command:

    $ oc create -f gpu-cluster-policy.yaml
    Copy to Clipboard Toggle word wrap

    Example output

    clusterpolicy.nvidia.com/gpu-cluster-policy created
    Copy to Clipboard Toggle word wrap

  4. Validate that the Operator is installed and running by running the following command:

    $ oc get pods -n nvidia-gpu-operator
    Copy to Clipboard Toggle word wrap

    Example output

    NAME                                                  READY   STATUS      RESTARTS   AGE
    gpu-feature-discovery-d5ngn                           1/1     Running     0          3m20s
    gpu-feature-discovery-z42rx                           1/1     Running     0          3m23s
    gpu-operator-6bb4d4b4c5-njh78                         1/1     Running     0          4m35s
    nvidia-container-toolkit-daemonset-bkh8l              1/1     Running     0          3m20s
    nvidia-container-toolkit-daemonset-c4hzm              1/1     Running     0          3m23s
    nvidia-cuda-validator-4blvg                           0/1     Completed   0          106s
    nvidia-cuda-validator-tw8sl                           0/1     Completed   0          112s
    nvidia-dcgm-exporter-rrw4g                            1/1     Running     0          3m20s
    nvidia-dcgm-exporter-xc78t                            1/1     Running     0          3m23s
    nvidia-dcgm-nvxpf                                     1/1     Running     0          3m20s
    nvidia-dcgm-snj4j                                     1/1     Running     0          3m23s
    nvidia-device-plugin-daemonset-fk2xz                  1/1     Running     0          3m23s
    nvidia-device-plugin-daemonset-wq87j                  1/1     Running     0          3m20s
    nvidia-driver-daemonset-416.94.202410211619-0-ngrjg   4/4     Running     0          3m58s
    nvidia-driver-daemonset-416.94.202410211619-0-tm4x6   4/4     Running     0          3m58s
    nvidia-node-status-exporter-jlzxh                     1/1     Running     0          3m57s
    nvidia-node-status-exporter-zjffs                     1/1     Running     0          3m57s
    nvidia-operator-validator-l49hx                       1/1     Running     0          3m20s
    nvidia-operator-validator-n44nn                       1/1     Running     0          3m23s
    Copy to Clipboard Toggle word wrap

  5. Optional: When you have verified the pods are running, remote shell into the NVIDIA driver daemonset pod and confirm that the NVIDIA modules are loaded. Specifically, ensure the nvidia_peermem is loaded.

    $ oc rsh -n nvidia-gpu-operator $(oc -n nvidia-gpu-operator get pod -o name -l app.kubernetes.io/component=nvidia-driver)
    sh-4.4# lsmod|grep nvidia
    Copy to Clipboard Toggle word wrap

    Example output

    nvidia_fs             327680  0
    nvidia_peermem         24576  0
    nvidia_modeset       1507328  0
    video                  73728  1 nvidia_modeset
    nvidia_uvm           6889472  8
    nvidia               8810496  43 nvidia_uvm,nvidia_peermem,nvidia_fs,gdrdrv,nvidia_modeset
    ib_uverbs             217088  3 nvidia_peermem,rdma_ucm,mlx5_ib
    drm                   741376  5 drm_kms_helper,drm_shmem_helper,nvidia,mgag200
    Copy to Clipboard Toggle word wrap

  6. Optional: Run the nvidia-smi utility to show the details about the driver and the hardware:
sh-4.4# nvidia-smi
Copy to Clipboard Toggle word wrap

+ .Example output

Wed Nov  6 22:03:53 2024
+-----------------------------------------------------------------------------------------+
| NVIDIA-SMI 550.90.07              Driver Version: 550.90.07      CUDA Version: 12.4     |
|-----------------------------------------+------------------------+----------------------+
| GPU  Name                 Persistence-M | Bus-Id          Disp.A | Volatile Uncorr. ECC |
| Fan  Temp   Perf          Pwr:Usage/Cap |           Memory-Usage | GPU-Util  Compute M. |
|                                         |                        |               MIG M. |
|=========================================+========================+======================|
|   0  NVIDIA A40                     On  |   00000000:61:00.0 Off |                    0 |
|  0%   37C    P0             88W /  300W |       1MiB /  46068MiB |      0%      Default |
|                                         |                        |                  N/A |
+-----------------------------------------+------------------------+----------------------+
|   1  NVIDIA A40                     On  |   00000000:E1:00.0 Off |                    0 |
|  0%   28C    P8             29W /  300W |       1MiB /  46068MiB |      0%      Default |
|                                         |                        |                  N/A |
+-----------------------------------------+------------------------+----------------------+

+-----------------------------------------------------------------------------------------+
| Processes:                                                                              |
|  GPU   GI   CI        PID   Type   Process name                              GPU Memory |
|        ID   ID                                                               Usage      |
|=========================================================================================|
|  No running processes found                                                             |
+-----------------------------------------------------------------------------------------+
Copy to Clipboard Toggle word wrap
  1. While you are still in the driver pod, set the GPU clock to maximum using the nvidia-smi command:

    $ oc rsh -n nvidia-gpu-operator nvidia-driver-daemonset-416.94.202410172137-0-ndhzc
    sh-4.4# nvidia-smi -i 0 -lgc $(nvidia-smi -i 0 --query-supported-clocks=graphics --format=csv,noheader,nounits | sort -h | tail -n 1)
    Copy to Clipboard Toggle word wrap

    Example output

    GPU clocks set to "(gpuClkMin 1740, gpuClkMax 1740)" for GPU 00000000:61:00.0
    All done.
    Copy to Clipboard Toggle word wrap

    sh-4.4# nvidia-smi -i 1 -lgc $(nvidia-smi -i 1 --query-supported-clocks=graphics --format=csv,noheader,nounits | sort -h | tail -n 1)
    Copy to Clipboard Toggle word wrap

    Example output

    GPU clocks set to "(gpuClkMin 1740, gpuClkMax 1740)" for GPU 00000000:E1:00.0
    All done.
    Copy to Clipboard Toggle word wrap

  2. Validate the resource is available from a node describe perspective by running the following command:

    $ oc describe node -l node-role.kubernetes.io/worker=| grep -E 'Capacity:|Allocatable:' -A9
    Copy to Clipboard Toggle word wrap

    Example output

    Capacity:
      cpu:                          128
      ephemeral-storage:            1561525616Ki
      hugepages-1Gi:                0
      hugepages-2Mi:                0
      memory:                       263596712Ki
      nvidia.com/gpu:               2
      pods:                         250
      rdma/rdma_shared_device_eth:  63
      rdma/rdma_shared_device_ib:   63
    Allocatable:
      cpu:                          127500m
      ephemeral-storage:            1438028263499
      hugepages-1Gi:                0
      hugepages-2Mi:                0
      memory:                       262445736Ki
      nvidia.com/gpu:               2
      pods:                         250
      rdma/rdma_shared_device_eth:  63
      rdma/rdma_shared_device_ib:   63
    --
    Capacity:
      cpu:                          128
      ephemeral-storage:            1561525616Ki
      hugepages-1Gi:                0
      hugepages-2Mi:                0
      memory:                       263596672Ki
      nvidia.com/gpu:               2
      pods:                         250
      rdma/rdma_shared_device_eth:  63
      rdma/rdma_shared_device_ib:   63
    Allocatable:
      cpu:                          127500m
      ephemeral-storage:            1438028263499
      hugepages-1Gi:                0
      hugepages-2Mi:                0
      memory:                       262445696Ki
      nvidia.com/gpu:               2
      pods:                         250
      rdma/rdma_shared_device_eth:  63
      rdma/rdma_shared_device_ib:   63
    Copy to Clipboard Toggle word wrap

5.8. Creating the machine configuration

Before you create the resource pods, you need to create the machineconfig.yaml custom resource (CR) that provides access to the GPU and networking resources without the need for user privileges.

Procedure

  1. Generate a Machineconfig CR:

    apiVersion: machineconfiguration.openshift.io/v1
    kind: MachineConfig
    metadata:
      labels:
        machineconfiguration.openshift.io/role: worker
      name: 02-worker-container-runtime
    spec:
      config:
        ignition:
          version: 3.2.0
        storage:
          files:
          - contents:
              source: data:text/plain;charset=utf-8;base64,W2NyaW8ucnVudGltZV0KZGVmYXVsdF91bGltaXRzID0gWwoibWVtbG9jaz0tMTotMSIKXQo=
            mode: 420
            overwrite: true
            path: /etc/crio/crio.conf.d/10-custom
    Copy to Clipboard Toggle word wrap

5.9. Creating the workload pods

Use the procedures in this section to create the workload pods for the shared and host devices.

5.9.1. Creating a shared device RDMA on RoCE

Create the workload pods for a shared device RDMA on RDMA over Converged Ethernet (RoCE) for the NVIDIA Network Operator and test the pod configuration.

The NVIDIA GPUDirect RDMA device is shared among pods on the OpenShift Container Platform worker node where the device is exposed.

Prerequisites

  • Ensure that the Operator is running.
  • Delete the NicClusterPolicy custom resource (CR), if it exists.

Procedure

  1. Generate custom pod resources:

    $ cat <<EOF > rdma-eth-32-workload.yaml
    apiVersion: v1
    kind: Pod
    metadata:
      name: rdma-eth-32-workload
      namespace: default
      annotations:
        k8s.v1.cni.cncf.io/networks: rdmashared-net
    spec:
      nodeSelector:
        kubernetes.io/hostname: nvd-srv-32.nvidia.eng.rdu2.dc.redhat.com
      containers:
      - image: quay.io/edge-infrastructure/nvidia-tools:0.1.5
        name: rdma-eth-32-workload
        resources:
          limits:
            nvidia.com/gpu: 1
            rdma/rdma_shared_device_eth: 1
          requests:
            nvidia.com/gpu: 1
            rdma/rdma_shared_device_eth: 1
    
    EOF
    
    $ cat <<EOF > rdma-eth-33-workload.yaml
    apiVersion: v1
    kind: Pod
    metadata:
      name: rdma-eth-33-workload
      namespace: default
      annotations:
        k8s.v1.cni.cncf.io/networks: rdmashared-net
    spec:
      nodeSelector:
        kubernetes.io/hostname: nvd-srv-33.nvidia.eng.rdu2.dc.redhat.com
      containers:
      - image: quay.io/edge-infrastructure/nvidia-tools:0.1.5
        name: rdma-eth-33-workload
        securityContext:
          capabilities:
            add: [ "IPC_LOCK" ]
        resources:
          limits:
            nvidia.com/gpu: 1
            rdma/rdma_shared_device_eth: 1
          requests:
            nvidia.com/gpu: 1
            rdma/rdma_shared_device_eth: 1
    EOF
    Copy to Clipboard Toggle word wrap
  2. Create the pods on the cluster by using the following commands:

    $ oc create -f rdma-eth-32-workload.yaml
    Copy to Clipboard Toggle word wrap

    Example output

    pod/rdma-eth-32-workload created
    Copy to Clipboard Toggle word wrap

    $ oc create -f rdma-eth-33-workload.yaml
    Copy to Clipboard Toggle word wrap

    Example output

    pod/rdma-eth-33-workload created
    Copy to Clipboard Toggle word wrap

  3. Verify that the pods are running by using the following command:

    $ oc get pods -n default
    Copy to Clipboard Toggle word wrap

    Example output

    NAME                   READY   STATUS    RESTARTS   AGE
    rdma-eth-32-workload   1/1     Running   0          25s
    rdma-eth-33-workload   1/1     Running   0          22s
    Copy to Clipboard Toggle word wrap

5.9.2. Creating a host device RDMA on RoCE

Create the workload pods for a host device Remote Direct Memory Access (RDMA) for the NVIDIA Network Operator and test the pod configuration.

Prerequisites

  • Ensure that the Operator is running.
  • Delete the NicClusterPolicy custom resource (CR), if it exists.

Procedure

  1. Generate a new host device NicClusterPolicy (CR), as shown below:

    $ cat <<EOF > network-hostdev-nic-cluster-policy.yaml
    apiVersion: mellanox.com/v1alpha1
    kind: NicClusterPolicy
    metadata:
      name: nic-cluster-policy
    spec:
      ofedDriver:
        image: doca-driver
        repository: nvcr.io/nvidia/mellanox
        version: 24.10-0.7.0.0-0
        startupProbe:
          initialDelaySeconds: 10
          periodSeconds: 20
        livenessProbe:
          initialDelaySeconds: 30
          periodSeconds: 30
        readinessProbe:
          initialDelaySeconds: 10
          periodSeconds: 30
        env:
        - name: UNLOAD_STORAGE_MODULES
          value: "true"
        - name: RESTORE_DRIVER_ON_POD_TERMINATION
          value: "true"
        - name: CREATE_IFNAMES_UDEV
          value: "true"
      sriovDevicePlugin:
          image: sriov-network-device-plugin
          repository: ghcr.io/k8snetworkplumbingwg
          version: v3.7.0
          config: |
            {
              "resourceList": [
                  {
                      "resourcePrefix": "nvidia.com",
                      "resourceName": "hostdev",
                      "selectors": {
                          "vendors": ["15b3"],
                          "isRdma": true
                      }
                  }
              ]
            }
    EOF
    Copy to Clipboard Toggle word wrap
  2. Create the NicClusterPolicy CR on the cluster by using the following command:

    $ oc create -f network-hostdev-nic-cluster-policy.yaml
    Copy to Clipboard Toggle word wrap

    Example output

    nicclusterpolicy.mellanox.com/nic-cluster-policy created
    Copy to Clipboard Toggle word wrap

  3. Verify that the host device NicClusterPolicy CR by using the following command in the DOCA/MOFED container:

    $ oc get pods -n nvidia-network-operator
    Copy to Clipboard Toggle word wrap

    Example output

    NAME                                                          READY   STATUS    RESTARTS   AGE
    mofed-rhcos4.16-696886fcb4-ds-9sgvd                           2/2     Running   0          2m37s
    mofed-rhcos4.16-696886fcb4-ds-lkjd4                           2/2     Running   0          2m37s
    nvidia-network-operator-controller-manager-68d547dbbd-qsdkf   1/1     Running   0          141m
    sriov-device-plugin-6v2nz                                     1/1     Running   0          2m14s
    sriov-device-plugin-hc4t8                                     1/1     Running   0          2m14s
    Copy to Clipboard Toggle word wrap

  4. Confirm that the resources appear in the cluster oc describe node section by using the following command:

    $ oc describe node -l node-role.kubernetes.io/worker=| grep -E 'Capacity:|Allocatable:' -A7
    Copy to Clipboard Toggle word wrap

    Example output

    Capacity:
      cpu:                 128
      ephemeral-storage:   1561525616Ki
      hugepages-1Gi:       0
      hugepages-2Mi:       0
      memory:              263596708Ki
      nvidia.com/hostdev:  2
      pods:                250
    Allocatable:
      cpu:                 127500m
      ephemeral-storage:   1438028263499
      hugepages-1Gi:       0
      hugepages-2Mi:       0
      memory:              262445732Ki
      nvidia.com/hostdev:  2
      pods:                250
    --
    Capacity:
      cpu:                 128
      ephemeral-storage:   1561525616Ki
      hugepages-1Gi:       0
      hugepages-2Mi:       0
      memory:              263596704Ki
      nvidia.com/hostdev:  2
      pods:                250
    Allocatable:
      cpu:                 127500m
      ephemeral-storage:   1438028263499
      hugepages-1Gi:       0
      hugepages-2Mi:       0
      memory:              262445728Ki
      nvidia.com/hostdev:  2
      pods:                250
    Copy to Clipboard Toggle word wrap

  5. Create a HostDeviceNetwork CR file:

    $ cat <<EOF >  hostdev-network.yaml
    apiVersion: mellanox.com/v1alpha1
    kind: HostDeviceNetwork
    metadata:
      name: hostdev-net
    spec:
      networkNamespace: "default"
      resourceName: "hostdev"
      ipam: |
        {
          "type": "whereabouts",
          "range": "192.168.3.225/28",
          "exclude": [
           "192.168.3.229/30",
           "192.168.3.236/32"
          ]
        }
    EOF
    Copy to Clipboard Toggle word wrap
  6. Create the HostDeviceNetwork resource on the cluster by using the following command:

    $ oc create -f hostdev-network.yaml
    Copy to Clipboard Toggle word wrap

    Example output

    hostdevicenetwork.mellanox.com/hostdev-net created
    Copy to Clipboard Toggle word wrap

  7. Confirm that the resources appear in the cluster oc describe node section by using the following command:

    $ oc describe node -l node-role.kubernetes.io/worker=| grep -E 'Capacity:|Allocatable:' -A8
    Copy to Clipboard Toggle word wrap

    Example output

    Capacity:
      cpu:                 128
      ephemeral-storage:   1561525616Ki
      hugepages-1Gi:       0
      hugepages-2Mi:       0
      memory:              263596708Ki
      nvidia.com/gpu:      2
      nvidia.com/hostdev:  2
      pods:                250
    Allocatable:
      cpu:                 127500m
      ephemeral-storage:   1438028263499
      hugepages-1Gi:       0
      hugepages-2Mi:       0
      memory:              262445732Ki
      nvidia.com/gpu:      2
      nvidia.com/hostdev:  2
      pods:                250
    --
    Capacity:
      cpu:                 128
      ephemeral-storage:   1561525616Ki
      hugepages-1Gi:       0
      hugepages-2Mi:       0
      memory:              263596680Ki
      nvidia.com/gpu:      2
      nvidia.com/hostdev:  2
      pods:                250
    Allocatable:
      cpu:                 127500m
      ephemeral-storage:   1438028263499
      hugepages-1Gi:       0
      hugepages-2Mi:       0
      memory:              262445704Ki
      nvidia.com/gpu:      2
      nvidia.com/hostdev:  2
      pods:                250
    Copy to Clipboard Toggle word wrap

5.9.3. Creating a SR-IOV legacy mode RDMA on RoCE

Configure a Single Root I/O Virtualization (SR-IOV) legacy mode host device RDMA on RoCE.

Procedure

  1. Generate a new host device NicClusterPolicy custom resource (CR):

    $ cat <<EOF > network-sriovleg-nic-cluster-policy.yaml
    apiVersion: mellanox.com/v1alpha1
    kind: NicClusterPolicy
    metadata:
      name: nic-cluster-policy
    spec:
      ofedDriver:
        image: doca-driver
        repository: nvcr.io/nvidia/mellanox
        version: 24.10-0.7.0.0-0
        startupProbe:
          initialDelaySeconds: 10
          periodSeconds: 20
        livenessProbe:
          initialDelaySeconds: 30
          periodSeconds: 30
        readinessProbe:
          initialDelaySeconds: 10
          periodSeconds: 30
        env:
        - name: UNLOAD_STORAGE_MODULES
          value: "true"
        - name: RESTORE_DRIVER_ON_POD_TERMINATION
          value: "true"
        - name: CREATE_IFNAMES_UDEV
          value: "true"
    EOF
    Copy to Clipboard Toggle word wrap
  2. Create the policy on the cluster by using the following command:

    $ oc create -f network-sriovleg-nic-cluster-policy.yaml
    Copy to Clipboard Toggle word wrap

    Example output

    nicclusterpolicy.mellanox.com/nic-cluster-policy created
    Copy to Clipboard Toggle word wrap

  3. Verify the pods by using the following command in the DOCA/MOFED container:

    $ oc get pods -n nvidia-network-operator
    Copy to Clipboard Toggle word wrap

    Example output

    NAME                                                          READY   STATUS    RESTARTS      AGE
    mofed-rhcos4.16-696886fcb4-ds-4mb42                           2/2     Running   0             40s
    mofed-rhcos4.16-696886fcb4-ds-8knwq                           2/2     Running   0             40s
    nvidia-network-operator-controller-manager-68d547dbbd-qsdkf   1/1     Running   13 (4d ago)   4d21h
    Copy to Clipboard Toggle word wrap

  4. Create an SriovNetworkNodePolicy CR that generates the Virtual Functions (VFs) for the device you want to operate in SR-IOV legacy mode. See the following example:

    $ cat <<EOF > sriov-network-node-policy.yaml
    apiVersion: sriovnetwork.openshift.io/v1
    kind: SriovNetworkNodePolicy
    metadata:
      name: sriov-legacy-policy
      namespace:  openshift-sriov-network-operator
    spec:
      deviceType: netdevice
      mtu: 1500
      nicSelector:
        vendor: "15b3"
        pfNames: ["ens8f0np0#0-7"]
      nodeSelector:
        feature.node.kubernetes.io/pci-15b3.present: "true"
      numVfs: 8
      priority: 90
      isRdma: true
      resourceName: sriovlegacy
    EOF
    Copy to Clipboard Toggle word wrap
  5. Create the CR on the cluster by using the following command:

    Note
    $ oc create -f sriov-network-node-policy.yaml
    Copy to Clipboard Toggle word wrap

    Example output

    sriovnetworknodepolicy.sriovnetwork.openshift.io/sriov-legacy-policy created
    Copy to Clipboard Toggle word wrap

  6. Each node has scheduling disabled. The nodes reboot to apply the configuration. You can view the nodes by using the following command:

    $ oc get nodes
    Copy to Clipboard Toggle word wrap

    Example output

    NAME                                       STATUS                        ROLES                         AGE     VERSION
    edge-19.edge.lab.eng.rdu2.redhat.com       Ready                         control-plane,master,worker   5d      v1.29.8+632b078
    nvd-srv-32.nvidia.eng.rdu2.dc.redhat.com   Ready                         worker                        4d22h   v1.29.8+632b078
    nvd-srv-33.nvidia.eng.rdu2.dc.redhat.com   NotReady,SchedulingDisabled   worker                        4d22h   v1.29.8+632b078
    Copy to Clipboard Toggle word wrap

  7. After the nodes have rebooted, verify that the VF interfaces exist by opening up a debug pod on each node. Run the following command:

    a$ oc debug node/nvd-srv-33.nvidia.eng.rdu2.dc.redhat.com
    Copy to Clipboard Toggle word wrap

    Example output

    Starting pod/nvd-srv-33nvidiaengrdu2dcredhatcom-debug-cqfjz ...
    To use host binaries, run `chroot /host`
    Pod IP: 10.6.135.12
    If you don't see a command prompt, try pressing enter.
    sh-5.1# chroot /host
    sh-5.1# ip link show | grep ens8
    26: ens8f0np0: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc mq state UP mode DEFAULT group default qlen 1000
    42: ens8f0v0: <BROADCAST,MULTICAST> mtu 1500 qdisc noop state DOWN mode DEFAULT group default qlen 1000
    43: ens8f0v1: <BROADCAST,MULTICAST> mtu 1500 qdisc noop state DOWN mode DEFAULT group default qlen 1000
    44: ens8f0v2: <BROADCAST,MULTICAST> mtu 1500 qdisc noop state DOWN mode DEFAULT group default qlen 1000
    45: ens8f0v3: <BROADCAST,MULTICAST> mtu 1500 qdisc noop state DOWN mode DEFAULT group default qlen 1000
    46: ens8f0v4: <BROADCAST,MULTICAST> mtu 1500 qdisc noop state DOWN mode DEFAULT group default qlen 1000
    47: ens8f0v5: <BROADCAST,MULTICAST> mtu 1500 qdisc noop state DOWN mode DEFAULT group default qlen 1000
    48: ens8f0v6: <BROADCAST,MULTICAST> mtu 1500 qdisc noop state DOWN mode DEFAULT group default qlen 1000
    49: ens8f0v7: <BROADCAST,MULTICAST> mtu 1500 qdisc noop state DOWN mode DEFAULT group default qlen 1000
    Copy to Clipboard Toggle word wrap

  8. Repeat the previous steps on the second node, if necessary.
  9. Optional: Confirm that the resources appear in the cluster oc describe node section by using the following command:

    $ oc describe node -l node-role.kubernetes.io/worker=| grep -E 'Capacity:|Allocatable:' -A8
    Copy to Clipboard Toggle word wrap

    Example output

    Capacity:
      cpu:                       128
      ephemeral-storage:         1561525616Ki
      hugepages-1Gi:             0
      hugepages-2Mi:             0
      memory:                    263596692Ki
      nvidia.com/gpu:            2
      nvidia.com/hostdev:        0
      openshift.io/sriovlegacy:  8
    --
    Allocatable:
      cpu:                       127500m
      ephemeral-storage:         1438028263499
      hugepages-1Gi:             0
      hugepages-2Mi:             0
      memory:                    262445716Ki
      nvidia.com/gpu:            2
      nvidia.com/hostdev:        0
      openshift.io/sriovlegacy:  8
    --
    Capacity:
      cpu:                       128
      ephemeral-storage:         1561525616Ki
      hugepages-1Gi:             0
      hugepages-2Mi:             0
      memory:                    263596688Ki
      nvidia.com/gpu:            2
      nvidia.com/hostdev:        0
      openshift.io/sriovlegacy:  8
    --
    Allocatable:
      cpu:                       127500m
      ephemeral-storage:         1438028263499
      hugepages-1Gi:             0
      hugepages-2Mi:             0
      memory:                    262445712Ki
      nvidia.com/gpu:            2
      nvidia.com/hostdev:        0
      openshift.io/sriovlegacy:  8
    Copy to Clipboard Toggle word wrap

  10. After the VFs for SR-IOV legacy mode are in place, generate the SriovNetwork CR file. See the following example:

    $ cat <<EOF > sriov-network.yaml
    apiVersion: sriovnetwork.openshift.io/v1
    kind: SriovNetwork
    metadata:
      name: sriov-network
      namespace:  openshift-sriov-network-operator
    spec:
      vlan: 0
      networkNamespace: "default"
      resourceName: "sriovlegacy"
      ipam: |
        {
          "type": "whereabouts",
          "range": "192.168.3.225/28",
          "exclude": [
           "192.168.3.229/30",
           "192.168.3.236/32"
          ]
        }
    EOF
    Copy to Clipboard Toggle word wrap
  11. Create the custom resource on the cluster by using the following command:

    $ oc create -f sriov-network.yaml
    Copy to Clipboard Toggle word wrap

    Example output

    sriovnetwork.sriovnetwork.openshift.io/sriov-network created
    Copy to Clipboard Toggle word wrap

5.9.4. Creating a shared device RDMA on Infiniband

Create the workload pods for a shared device Remote Direct Memory Access (RDMA) for an Infiniband installation.

Procedure

  1. Generate custom pod resources:

    $ cat <<EOF > rdma-ib-32-workload.yaml
    apiVersion: v1
    kind: Pod
    metadata:
      name: rdma-ib-32-workload
      namespace: default
      annotations:
        k8s.v1.cni.cncf.io/networks: example-ipoibnetwork
    spec:
      nodeSelector:
        kubernetes.io/hostname: nvd-srv-32.nvidia.eng.rdu2.dc.redhat.com
      containers:
      - image: quay.io/edge-infrastructure/nvidia-tools:0.1.5
        name: rdma-ib-32-workload
        resources:
          limits:
            nvidia.com/gpu: 1
            rdma/rdma_shared_device_ib: 1
          requests:
            nvidia.com/gpu: 1
            rdma/rdma_shared_device_ib: 1
    EOF
    
    $ cat <<EOF > rdma-ib-32-workload.yaml
    apiVersion: v1
    kind: Pod
    metadata:
      name: rdma-ib-33-workload
      namespace: default
      annotations:
        k8s.v1.cni.cncf.io/networks: example-ipoibnetwork
    spec:
      nodeSelector:
        kubernetes.io/hostname: nvd-srv-33.nvidia.eng.rdu2.dc.redhat.com
      containers:
      - image: quay.io/edge-infrastructure/nvidia-tools:0.1.5
        name: rdma-ib-33-workload
        securityContext:
          capabilities:
            add: [ "IPC_LOCK" ]
        resources:
          limits:
            nvidia.com/gpu: 1
            rdma/rdma_shared_device_ib: 1
          requests:
            nvidia.com/gpu: 1
            rdma/rdma_shared_device_ib: 1
    EOF
    Copy to Clipboard Toggle word wrap
  2. Create the pods on the cluster by using the following commands:

    $ oc create -f rdma-ib-32-workload.yaml
    Copy to Clipboard Toggle word wrap

    Example output

    pod/rdma-ib-32-workload created
    Copy to Clipboard Toggle word wrap

    $ oc create -f rdma-ib-33-workload.yaml
    Copy to Clipboard Toggle word wrap

    Example output

    pod/rdma-ib-33-workload created
    Copy to Clipboard Toggle word wrap

  3. Verify that the pods are running by using the following command:

    $ oc get pods
    Copy to Clipboard Toggle word wrap

    Example output

    NAME                  READY   STATUS    RESTARTS   AGE
    rdma-ib-32-workload   1/1     Running   0          10s
    rdma-ib-33-workload   1/1     Running   0          3s
    Copy to Clipboard Toggle word wrap

5.10. Verifying RDMA connectivity

Confirm Remote Direct Memory Access (RDMA) connectivity is working between the systems, specifically for Legacy Single Root I/O Virtualization (SR-IOV) Ethernet.

Procedure

  1. Connect to each rdma-workload-client pod by using the following command:

    $ oc rsh -n default rdma-sriov-32-workload
    Copy to Clipboard Toggle word wrap

    Example output

    sh-5.1#
    Copy to Clipboard Toggle word wrap

  2. Check the IP address assigned to the first workload pod by using the following command. In this example, the first workload pod is the RDMA test server.

    sh-5.1# ip a
    Copy to Clipboard Toggle word wrap

    Example output

    1: lo: <LOOPBACK,UP,LOWER_UP> mtu 65536 qdisc noqueue state UNKNOWN group default qlen 1000
        link/loopback 00:00:00:00:00:00 brd 00:00:00:00:00:00
        inet 127.0.0.1/8 scope host lo
           valid_lft forever preferred_lft forever
        inet6 ::1/128 scope host
           valid_lft forever preferred_lft forever
    2: eth0@if3970: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1400 qdisc noqueue state UP group default
        link/ether 0a:58:0a:80:02:a7 brd ff:ff:ff:ff:ff:ff link-netnsid 0
        inet 10.128.2.167/23 brd 10.128.3.255 scope global eth0
           valid_lft forever preferred_lft forever
        inet6 fe80::858:aff:fe80:2a7/64 scope link
           valid_lft forever preferred_lft forever
    3843: net1: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc mq state UP group default qlen 1000
        link/ether 26:34:fd:53:a6:ec brd ff:ff:ff:ff:ff:ff
        altname enp55s0f0v5
        inet 192.168.4.225/28 brd 192.168.4.239 scope global net1
           valid_lft forever preferred_lft forever
        inet6 fe80::2434:fdff:fe53:a6ec/64 scope link
           valid_lft forever preferred_lft forever
    sh-5.1#
    Copy to Clipboard Toggle word wrap

    The IP address of the RDMA server assigned to this pod is the net1 interface. In this example, the IP address is 192.168.4.225.

  3. Run the ibstatus command to get the link_layer type, Ethernet or Infiniband, associated with each RDMA device mlx5_x. The output also shows the status of all of the RDMA devices by checking the state field, which shows either ACTIVE or DOWN.

    sh-5.1# ibstatus
    Copy to Clipboard Toggle word wrap

    Example output

    Infiniband device 'mlx5_0' port 1 status:
    	default gid:	 0000:0000:0000:0000:0000:0000:0000:0000
    	base lid:	 0x0
    	sm lid:		 0x0
    	state:		 4: ACTIVE
    	phys state:	 5: LinkUp
    	rate:		 200 Gb/sec (4X HDR)
    	link_layer:	 Ethernet
    
    Infiniband device 'mlx5_1' port 1 status:
    	default gid:	 fe80:0000:0000:0000:e8eb:d303:0072:1415
    	base lid:	 0xc
    	sm lid:		 0x1
    	state:		 4: ACTIVE
    	phys state:	 5: LinkUp
    	rate:		 200 Gb/sec (4X HDR)
    	link_layer:	 InfiniBand
    
    Infiniband device 'mlx5_2' port 1 status:
    	default gid:	 0000:0000:0000:0000:0000:0000:0000:0000
    	base lid:	 0x0
    	sm lid:		 0x0
    	state:		 1: DOWN
    	phys state:	 3: Disabled
    	rate:		 200 Gb/sec (4X HDR)
    	link_layer:	 Ethernet
    
    Infiniband device 'mlx5_3' port 1 status:
    	default gid:	 0000:0000:0000:0000:0000:0000:0000:0000
    	base lid:	 0x0
    	sm lid:		 0x0
    	state:		 1: DOWN
    	phys state:	 3: Disabled
    	rate:		 200 Gb/sec (4X HDR)
    	link_layer:	 Ethernet
    
    Infiniband device 'mlx5_4' port 1 status:
    	default gid:	 0000:0000:0000:0000:0000:0000:0000:0000
    	base lid:	 0x0
    	sm lid:		 0x0
    	state:		 1: DOWN
    	phys state:	 3: Disabled
    	rate:		 200 Gb/sec (4X HDR)
    	link_layer:	 Ethernet
    
    Infiniband device 'mlx5_5' port 1 status:
    	default gid:	 0000:0000:0000:0000:0000:0000:0000:0000
    	base lid:	 0x0
    	sm lid:		 0x0
    	state:		 1: DOWN
    	phys state:	 3: Disabled
    	rate:		 200 Gb/sec (4X HDR)
    	link_layer:	 Ethernet
    
    Infiniband device 'mlx5_6' port 1 status:
    	default gid:	 0000:0000:0000:0000:0000:0000:0000:0000
    	base lid:	 0x0
    	sm lid:		 0x0
    	state:		 1: DOWN
    	phys state:	 3: Disabled
    	rate:		 200 Gb/sec (4X HDR)
    	link_layer:	 Ethernet
    
    Infiniband device 'mlx5_7' port 1 status:
    	default gid:	 fe80:0000:0000:0000:2434:fdff:fe53:a6ec
    	base lid:	 0x0
    	sm lid:		 0x0
    	state:		 4: ACTIVE
    	phys state:	 5: LinkUp
    	rate:		 200 Gb/sec (4X HDR)
    	link_layer:	 Ethernet
    
    Infiniband device 'mlx5_8' port 1 status:
    	default gid:	 0000:0000:0000:0000:0000:0000:0000:0000
    	base lid:	 0x0
    	sm lid:		 0x0
    	state:		 1: DOWN
    	phys state:	 3: Disabled
    	rate:		 200 Gb/sec (4X HDR)
    	link_layer:	 Ethernet
    
    Infiniband device 'mlx5_9' port 1 status:
    	default gid:	 0000:0000:0000:0000:0000:0000:0000:0000
    	base lid:	 0x0
    	sm lid:		 0x0
    	state:		 1: DOWN
    	phys state:	 3: Disabled
    	rate:		 200 Gb/sec (4X HDR)
    	link_layer:	 Ethernet
    
    sh-5.1#
    Copy to Clipboard Toggle word wrap

  4. To get the link_layer for each RDMA mlx5 device on your worker node, run the ibstat command:

    sh-5.1# ibstat | egrep "Port|Base|Link"
    Copy to Clipboard Toggle word wrap

    Example output

    Port 1:
    		Physical state: LinkUp
    		Base lid: 0
    		Port GUID: 0x0000000000000000
    		Link layer: Ethernet
    	Port 1:
    		Physical state: LinkUp
    		Base lid: 12
    		Port GUID: 0xe8ebd30300721415
    		Link layer: InfiniBand
    	Port 1:
    		Base lid: 0
    		Port GUID: 0x0000000000000000
    		Link layer: Ethernet
    	Port 1:
    		Base lid: 0
    		Port GUID: 0x0000000000000000
    		Link layer: Ethernet
    	Port 1:
    		Base lid: 0
    		Port GUID: 0x0000000000000000
    		Link layer: Ethernet
    	Port 1:
    		Base lid: 0
    		Port GUID: 0x0000000000000000
    		Link layer: Ethernet
    	Port 1:
    		Base lid: 0
    		Port GUID: 0x0000000000000000
    		Link layer: Ethernet
    	Port 1:
    		Physical state: LinkUp
    		Base lid: 0
    		Port GUID: 0x2434fdfffe53a6ec
    		Link layer: Ethernet
    	Port 1:
    		Base lid: 0
    		Port GUID: 0x0000000000000000
    		Link layer: Ethernet
    	Port 1:
    		Base lid: 0
    		Port GUID: 0x0000000000000000
    		Link layer: Ethernet
    sh-5.1#
    Copy to Clipboard Toggle word wrap

  5. For RDMA Shared Device or Host Device workload pods, the RDMA device named mlx5_x is already known and is typically mlx5_0 or mlx5_1. For RDMA Legacy SR-IOV workload pods, you need to determine which RDMA device is associated with which Virtual Function (VF) subinterface. Provide this information by using the following command:

    sh-5.1# rdma link show
    Copy to Clipboard Toggle word wrap

    Example output

    link mlx5_0/1 state ACTIVE physical_state LINK_UP
    link mlx5_1/1 subnet_prefix fe80:0000:0000:0000 lid 12 sm_lid 1 lmc 0 state ACTIVE physical_state LINK_UP
    link mlx5_2/1 state DOWN physical_state DISABLED
    link mlx5_3/1 state DOWN physical_state DISABLED
    link mlx5_4/1 state DOWN physical_state DISABLED
    link mlx5_5/1 state DOWN physical_state DISABLED
    link mlx5_6/1 state DOWN physical_state DISABLED
    link mlx5_7/1 state ACTIVE physical_state LINK_UP netdev net1
    link mlx5_8/1 state DOWN physical_state DISABLED
    link mlx5_9/1 state DOWN physical_state DISABLED
    Copy to Clipboard Toggle word wrap

    In this example, the RDMA device names mlx5_7 is associated with the net1 interface. This output is used in the next command to perform the RDMA bandwidth test, which also verifies RDMA connectivity between worker nodes.

  6. Run the following ib_write_bw RDMA bandwidth test command:

    sh-5.1# /root/perftest/ib_write_bw -R -T 41 -s 65536 -F -x 3 -m 4096 --report_gbits -q 16 -D 60  -d mlx5_7 -p 10000 --source_ip  192.168.4.225 --use_cuda=0 --use_cuda_dmabuf
    Copy to Clipboard Toggle word wrap

    where:

    • The mlx5_7 RDMA device is passed in the -d switch.
    • The source IP address is 192.168.4.225 to start the RDMA server.
    • The --use_cuda=0, --use_cuda_dmabuf switches indicate that the use of GPUDirect RDMA.

    Example output

    WARNING: BW peak won't be measured in this run.
    Perftest doesn't supports CUDA tests with inline messages: inline size set to 0
    
    ************************************
    * Waiting for client to connect... *
    ************************************
    Copy to Clipboard Toggle word wrap

  7. Open another terminal window and run oc rsh command on the second workload pod that acts as the RDMA test client pod:

    $ oc rsh -n default rdma-sriov-33-workload
    Copy to Clipboard Toggle word wrap

    Example output

    sh-5.1#
    Copy to Clipboard Toggle word wrap

  8. Obtain the RDMA test client pod IP address from the net1 interface by using the following command:

    sh-5.1# ip a
    Copy to Clipboard Toggle word wrap

    Example output

    1: lo: <LOOPBACK,UP,LOWER_UP> mtu 65536 qdisc noqueue state UNKNOWN group default qlen 1000
        link/loopback 00:00:00:00:00:00 brd 00:00:00:00:00:00
        inet 127.0.0.1/8 scope host lo
           valid_lft forever preferred_lft forever
        inet6 ::1/128 scope host
           valid_lft forever preferred_lft forever
    2: eth0@if4139: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1400 qdisc noqueue state UP group default
        link/ether 0a:58:0a:83:01:d5 brd ff:ff:ff:ff:ff:ff link-netnsid 0
        inet 10.131.1.213/23 brd 10.131.1.255 scope global eth0
           valid_lft forever preferred_lft forever
        inet6 fe80::858:aff:fe83:1d5/64 scope link
           valid_lft forever preferred_lft forever
    4076: net1: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc mq state UP group default qlen 1000
        link/ether 56:6c:59:41:ae:4a brd ff:ff:ff:ff:ff:ff
        altname enp55s0f0v0
        inet 192.168.4.226/28 brd 192.168.4.239 scope global net1
           valid_lft forever preferred_lft forever
        inet6 fe80::546c:59ff:fe41:ae4a/64 scope link
           valid_lft forever preferred_lft forever
    sh-5.1#
    Copy to Clipboard Toggle word wrap

  9. Obtain the link_layer type associated with each RDMA device mlx5_x by using the following command:

    sh-5.1# ibstatus
    Copy to Clipboard Toggle word wrap

    Example output

    Infiniband device 'mlx5_0' port 1 status:
    	default gid:	 0000:0000:0000:0000:0000:0000:0000:0000
    	base lid:	 0x0
    	sm lid:		 0x0
    	state:		 4: ACTIVE
    	phys state:	 5: LinkUp
    	rate:		 200 Gb/sec (4X HDR)
    	link_layer:	 Ethernet
    
    Infiniband device 'mlx5_1' port 1 status:
    	default gid:	 fe80:0000:0000:0000:e8eb:d303:0072:09f5
    	base lid:	 0xd
    	sm lid:		 0x1
    	state:		 4: ACTIVE
    	phys state:	 5: LinkUp
    	rate:		 200 Gb/sec (4X HDR)
    	link_layer:	 InfiniBand
    
    Infiniband device 'mlx5_2' port 1 status:
    	default gid:	 fe80:0000:0000:0000:546c:59ff:fe41:ae4a
    	base lid:	 0x0
    	sm lid:		 0x0
    	state:		 4: ACTIVE
    	phys state:	 5: LinkUp
    	rate:		 200 Gb/sec (4X HDR)
    	link_layer:	 Ethernet
    
    Infiniband device 'mlx5_3' port 1 status:
    	default gid:	 0000:0000:0000:0000:0000:0000:0000:0000
    	base lid:	 0x0
    	sm lid:		 0x0
    	state:		 1: DOWN
    	phys state:	 3: Disabled
    	rate:		 200 Gb/sec (4X HDR)
    	link_layer:	 Ethernet
    
    Infiniband device 'mlx5_4' port 1 status:
    	default gid:	 0000:0000:0000:0000:0000:0000:0000:0000
    	base lid:	 0x0
    	sm lid:		 0x0
    	state:		 1: DOWN
    	phys state:	 3: Disabled
    	rate:		 200 Gb/sec (4X HDR)
    	link_layer:	 Ethernet
    
    Infiniband device 'mlx5_5' port 1 status:
    	default gid:	 0000:0000:0000:0000:0000:0000:0000:0000
    	base lid:	 0x0
    	sm lid:		 0x0
    	state:		 1: DOWN
    	phys state:	 3: Disabled
    	rate:		 200 Gb/sec (4X HDR)
    	link_layer:	 Ethernet
    
    Infiniband device 'mlx5_6' port 1 status:
    	default gid:	 0000:0000:0000:0000:0000:0000:0000:0000
    	base lid:	 0x0
    	sm lid:		 0x0
    	state:		 1: DOWN
    	phys state:	 3: Disabled
    	rate:		 200 Gb/sec (4X HDR)
    	link_layer:	 Ethernet
    
    Infiniband device 'mlx5_7' port 1 status:
    	default gid:	 0000:0000:0000:0000:0000:0000:0000:0000
    	base lid:	 0x0
    	sm lid:		 0x0
    	state:		 1: DOWN
    	phys state:	 3: Disabled
    	rate:		 200 Gb/sec (4X HDR)
    	link_layer:	 Ethernet
    
    Infiniband device 'mlx5_8' port 1 status:
    	default gid:	 0000:0000:0000:0000:0000:0000:0000:0000
    	base lid:	 0x0
    	sm lid:		 0x0
    	state:		 1: DOWN
    	phys state:	 3: Disabled
    	rate:		 200 Gb/sec (4X HDR)
    	link_layer:	 Ethernet
    
    Infiniband device 'mlx5_9' port 1 status:
    	default gid:	 0000:0000:0000:0000:0000:0000:0000:0000
    	base lid:	 0x0
    	sm lid:		 0x0
    	state:		 1: DOWN
    	phys state:	 3: Disabled
    	rate:		 200 Gb/sec (4X HDR)
    	link_layer:	 Ethernet
    Copy to Clipboard Toggle word wrap

  10. Optional: Obtain the firmware version of Mellanox cards by using the ibstat command:

    sh-5.1# ibstat
    Copy to Clipboard Toggle word wrap

    Example output

    CA 'mlx5_0'
    	CA type: MT4123
    	Number of ports: 1
    	Firmware version: 20.43.1014
    	Hardware version: 0
    	Node GUID: 0xe8ebd303007209f4
    	System image GUID: 0xe8ebd303007209f4
    	Port 1:
    		State: Active
    		Physical state: LinkUp
    		Rate: 200
    		Base lid: 0
    		LMC: 0
    		SM lid: 0
    		Capability mask: 0x00010000
    		Port GUID: 0x0000000000000000
    		Link layer: Ethernet
    CA 'mlx5_1'
    	CA type: MT4123
    	Number of ports: 1
    	Firmware version: 20.43.1014
    	Hardware version: 0
    	Node GUID: 0xe8ebd303007209f5
    	System image GUID: 0xe8ebd303007209f4
    	Port 1:
    		State: Active
    		Physical state: LinkUp
    		Rate: 200
    		Base lid: 13
    		LMC: 0
    		SM lid: 1
    		Capability mask: 0xa651e848
    		Port GUID: 0xe8ebd303007209f5
    		Link layer: InfiniBand
    CA 'mlx5_2'
    	CA type: MT4124
    	Number of ports: 1
    	Firmware version: 20.43.1014
    	Hardware version: 0
    	Node GUID: 0x566c59fffe41ae4a
    	System image GUID: 0xe8ebd303007209f4
    	Port 1:
    		State: Active
    		Physical state: LinkUp
    		Rate: 200
    		Base lid: 0
    		LMC: 0
    		SM lid: 0
    		Capability mask: 0x00010000
    		Port GUID: 0x546c59fffe41ae4a
    		Link layer: Ethernet
    CA 'mlx5_3'
    	CA type: MT4124
    	Number of ports: 1
    	Firmware version: 20.43.1014
    	Hardware version: 0
    	Node GUID: 0xb2ae4bfffe8f3d02
    	System image GUID: 0xe8ebd303007209f4
    	Port 1:
    		State: Down
    		Physical state: Disabled
    		Rate: 200
    		Base lid: 0
    		LMC: 0
    		SM lid: 0
    		Capability mask: 0x00010000
    		Port GUID: 0x0000000000000000
    		Link layer: Ethernet
    CA 'mlx5_4'
    	CA type: MT4124
    	Number of ports: 1
    	Firmware version: 20.43.1014
    	Hardware version: 0
    	Node GUID: 0x2a9967fffe8bf272
    	System image GUID: 0xe8ebd303007209f4
    	Port 1:
    		State: Down
    		Physical state: Disabled
    		Rate: 200
    		Base lid: 0
    		LMC: 0
    		SM lid: 0
    		Capability mask: 0x00010000
    		Port GUID: 0x0000000000000000
    		Link layer: Ethernet
    CA 'mlx5_5'
    	CA type: MT4124
    	Number of ports: 1
    	Firmware version: 20.43.1014
    	Hardware version: 0
    	Node GUID: 0x5aff2ffffe2e17e8
    	System image GUID: 0xe8ebd303007209f4
    	Port 1:
    		State: Down
    		Physical state: Disabled
    		Rate: 200
    		Base lid: 0
    		LMC: 0
    		SM lid: 0
    		Capability mask: 0x00010000
    		Port GUID: 0x0000000000000000
    		Link layer: Ethernet
    CA 'mlx5_6'
    	CA type: MT4124
    	Number of ports: 1
    	Firmware version: 20.43.1014
    	Hardware version: 0
    	Node GUID: 0x121bf1fffe074419
    	System image GUID: 0xe8ebd303007209f4
    	Port 1:
    		State: Down
    		Physical state: Disabled
    		Rate: 200
    		Base lid: 0
    		LMC: 0
    		SM lid: 0
    		Capability mask: 0x00010000
    		Port GUID: 0x0000000000000000
    		Link layer: Ethernet
    CA 'mlx5_7'
    	CA type: MT4124
    	Number of ports: 1
    	Firmware version: 20.43.1014
    	Hardware version: 0
    	Node GUID: 0xb22b16fffed03dd7
    	System image GUID: 0xe8ebd303007209f4
    	Port 1:
    		State: Down
    		Physical state: Disabled
    		Rate: 200
    		Base lid: 0
    		LMC: 0
    		SM lid: 0
    		Capability mask: 0x00010000
    		Port GUID: 0x0000000000000000
    		Link layer: Ethernet
    CA 'mlx5_8'
    	CA type: MT4124
    	Number of ports: 1
    	Firmware version: 20.43.1014
    	Hardware version: 0
    	Node GUID: 0x523800fffe16d105
    	System image GUID: 0xe8ebd303007209f4
    	Port 1:
    		State: Down
    		Physical state: Disabled
    		Rate: 200
    		Base lid: 0
    		LMC: 0
    		SM lid: 0
    		Capability mask: 0x00010000
    		Port GUID: 0x0000000000000000
    		Link layer: Ethernet
    CA 'mlx5_9'
    	CA type: MT4124
    	Number of ports: 1
    	Firmware version: 20.43.1014
    	Hardware version: 0
    	Node GUID: 0xd2b4a1fffebdc4a9
    	System image GUID: 0xe8ebd303007209f4
    	Port 1:
    		State: Down
    		Physical state: Disabled
    		Rate: 200
    		Base lid: 0
    		LMC: 0
    		SM lid: 0
    		Capability mask: 0x00010000
    		Port GUID: 0x0000000000000000
    		Link layer: Ethernet
    sh-5.1#
    Copy to Clipboard Toggle word wrap

  11. To determine which RDMA device is associated with the Virtual Function subinterface that the client workload pod uses, run the following command. In this example, the net1 interface is using the RDMA device mlx5_2.

    sh-5.1# rdma link show
    Copy to Clipboard Toggle word wrap

    Example output

    link mlx5_0/1 state ACTIVE physical_state LINK_UP
    link mlx5_1/1 subnet_prefix fe80:0000:0000:0000 lid 13 sm_lid 1 lmc 0 state ACTIVE physical_state LINK_UP
    link mlx5_2/1 state ACTIVE physical_state LINK_UP netdev net1
    link mlx5_3/1 state DOWN physical_state DISABLED
    link mlx5_4/1 state DOWN physical_state DISABLED
    link mlx5_5/1 state DOWN physical_state DISABLED
    link mlx5_6/1 state DOWN physical_state DISABLED
    link mlx5_7/1 state DOWN physical_state DISABLED
    link mlx5_8/1 state DOWN physical_state DISABLED
    link mlx5_9/1 state DOWN physical_state DISABLED
    sh-5.1#
    Copy to Clipboard Toggle word wrap

  12. Run the following ib_write_bw RDMA bandwidth test command:

    sh-5.1# /root/perftest/ib_write_bw -R -T 41 -s 65536 -F -x 3 -m 4096 --report_gbits -q 16 -D 60  -d mlx5_2 -p 10000 --source_ip  192.168.4.226 --use_cuda=0 --use_cuda_dmabuf 192.168.4.225
    Copy to Clipboard Toggle word wrap

    where:

    • The mlx5_2 RDMA device is passed in the -d switch.
    • The source IP address 192.168.4.226 and the destination IP address of the RDMA server 192.168.4.225.
    • The --use_cuda=0, --use_cuda_dmabuf switches indicate that the use of GPUDirect RDMA.

      Example output

      WARNING: BW peak won't be measured in this run.
      Perftest doesn't supports CUDA tests with inline messages: inline size set to 0
      Requested mtu is higher than active mtu
      Changing to active mtu - 3
      initializing CUDA
      Listing all CUDA devices in system:
      CUDA device 0: PCIe address is 61:00
      
      Picking device No. 0
      [pid = 8909, dev = 0] device name = [NVIDIA A40]
      creating CUDA Ctx
      making it the current CUDA Ctx
      CUDA device integrated: 0
      using DMA-BUF for GPU buffer address at 0x7f8738600000 aligned at 0x7f8738600000 with aligned size 2097152
      allocated GPU buffer of a 2097152 address at 0x23a7420 for type CUDA_MEM_DEVICE
      Calling ibv_reg_dmabuf_mr(offset=0, size=2097152, addr=0x7f8738600000, fd=40) for QP #0
      ---------------------------------------------------------------------------------------
                          RDMA_Write BW Test
       Dual-port       : OFF		Device         : mlx5_2
       Number of qps   : 16		Transport type : IB
       Connection type : RC		Using SRQ      : OFF
       PCIe relax order: ON		Lock-free      : OFF
       ibv_wr* API     : ON		Using DDP      : OFF
       TX depth        : 128
       CQ Moderation   : 1
       CQE Poll Batch  : 16
       Mtu             : 1024[B]
       Link type       : Ethernet
       GID index       : 3
       Max inline data : 0[B]
       rdma_cm QPs	 : ON
       Data ex. method : rdma_cm 	TOS    : 41
      ---------------------------------------------------------------------------------------
       local address: LID 0000 QPN 0x012d PSN 0x3cb6d7
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       local address: LID 0000 QPN 0x012e PSN 0x90e0ac
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       local address: LID 0000 QPN 0x012f PSN 0x153f50
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       local address: LID 0000 QPN 0x0130 PSN 0x5e0128
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       local address: LID 0000 QPN 0x0131 PSN 0xd89752
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       local address: LID 0000 QPN 0x0132 PSN 0xe5fc16
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       local address: LID 0000 QPN 0x0133 PSN 0x236787
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       local address: LID 0000 QPN 0x0134 PSN 0xd9273e
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       local address: LID 0000 QPN 0x0135 PSN 0x37cfd4
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       local address: LID 0000 QPN 0x0136 PSN 0x3bff8f
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       local address: LID 0000 QPN 0x0137 PSN 0x81f2bd
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       local address: LID 0000 QPN 0x0138 PSN 0x575c43
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       local address: LID 0000 QPN 0x0139 PSN 0x6cf53d
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       local address: LID 0000 QPN 0x013a PSN 0xcaaf6f
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       local address: LID 0000 QPN 0x013b PSN 0x346437
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       local address: LID 0000 QPN 0x013c PSN 0xcc5865
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       remote address: LID 0000 QPN 0x026d PSN 0x359409
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       remote address: LID 0000 QPN 0x026e PSN 0xe387bf
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       remote address: LID 0000 QPN 0x026f PSN 0x5be79d
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       remote address: LID 0000 QPN 0x0270 PSN 0x1b4b28
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       remote address: LID 0000 QPN 0x0271 PSN 0x76a61b
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       remote address: LID 0000 QPN 0x0272 PSN 0x3d50e1
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       remote address: LID 0000 QPN 0x0273 PSN 0x1b572c
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       remote address: LID 0000 QPN 0x0274 PSN 0x4ae1b5
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       remote address: LID 0000 QPN 0x0275 PSN 0x5591b5
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       remote address: LID 0000 QPN 0x0276 PSN 0xfa2593
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       remote address: LID 0000 QPN 0x0277 PSN 0xd9473b
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       remote address: LID 0000 QPN 0x0278 PSN 0x2116b2
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       remote address: LID 0000 QPN 0x0279 PSN 0x9b83b6
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       remote address: LID 0000 QPN 0x027a PSN 0xa0822b
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       remote address: LID 0000 QPN 0x027b PSN 0x6d930d
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       remote address: LID 0000 QPN 0x027c PSN 0xb1a4d
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
      ---------------------------------------------------------------------------------------
       #bytes     #iterations    BW peak[Gb/sec]    BW average[Gb/sec]   MsgRate[Mpps]
       65536      10329004         0.00               180.47 		     0.344228
      ---------------------------------------------------------------------------------------
      deallocating GPU buffer 00007f8738600000
      destroying current CUDA Ctx
      sh-5.1#
      Copy to Clipboard Toggle word wrap

      A positive test is seeing an expected BW average and MsgRate in Mpps.

      Upon completion of the ib_write_bw command, the server side output also appears on the server pod. See the following example:

      Example output

      WARNING: BW peak won't be measured in this run.
      Perftest doesn't supports CUDA tests with inline messages: inline size set to 0
      
      ************************************
      * Waiting for client to connect... *
      ************************************
      Requested mtu is higher than active mtu
      Changing to active mtu - 3
      initializing CUDA
      Listing all CUDA devices in system:
      CUDA device 0: PCIe address is 61:00
      
      Picking device No. 0
      [pid = 9226, dev = 0] device name = [NVIDIA A40]
      creating CUDA Ctx
      making it the current CUDA Ctx
      CUDA device integrated: 0
      using DMA-BUF for GPU buffer address at 0x7f447a600000 aligned at 0x7f447a600000 with aligned size 2097152
      allocated GPU buffer of a 2097152 address at 0x2406400 for type CUDA_MEM_DEVICE
      Calling ibv_reg_dmabuf_mr(offset=0, size=2097152, addr=0x7f447a600000, fd=40) for QP #0
      ---------------------------------------------------------------------------------------
                          RDMA_Write BW Test
       Dual-port       : OFF		Device         : mlx5_7
       Number of qps   : 16		Transport type : IB
       Connection type : RC		Using SRQ      : OFF
       PCIe relax order: ON		Lock-free      : OFF
       ibv_wr* API     : ON		Using DDP      : OFF
       CQ Moderation   : 1
       CQE Poll Batch  : 16
       Mtu             : 1024[B]
       Link type       : Ethernet
       GID index       : 3
       Max inline data : 0[B]
       rdma_cm QPs	 : ON
       Data ex. method : rdma_cm 	TOS    : 41
      ---------------------------------------------------------------------------------------
       Waiting for client rdma_cm QP to connect
       Please run the same command with the IB/RoCE interface IP
      ---------------------------------------------------------------------------------------
       local address: LID 0000 QPN 0x026d PSN 0x359409
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       local address: LID 0000 QPN 0x026e PSN 0xe387bf
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       local address: LID 0000 QPN 0x026f PSN 0x5be79d
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       local address: LID 0000 QPN 0x0270 PSN 0x1b4b28
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       local address: LID 0000 QPN 0x0271 PSN 0x76a61b
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       local address: LID 0000 QPN 0x0272 PSN 0x3d50e1
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       local address: LID 0000 QPN 0x0273 PSN 0x1b572c
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       local address: LID 0000 QPN 0x0274 PSN 0x4ae1b5
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       local address: LID 0000 QPN 0x0275 PSN 0x5591b5
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       local address: LID 0000 QPN 0x0276 PSN 0xfa2593
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       local address: LID 0000 QPN 0x0277 PSN 0xd9473b
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       local address: LID 0000 QPN 0x0278 PSN 0x2116b2
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       local address: LID 0000 QPN 0x0279 PSN 0x9b83b6
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       local address: LID 0000 QPN 0x027a PSN 0xa0822b
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       local address: LID 0000 QPN 0x027b PSN 0x6d930d
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       local address: LID 0000 QPN 0x027c PSN 0xb1a4d
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:225
       remote address: LID 0000 QPN 0x012d PSN 0x3cb6d7
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       remote address: LID 0000 QPN 0x012e PSN 0x90e0ac
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       remote address: LID 0000 QPN 0x012f PSN 0x153f50
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       remote address: LID 0000 QPN 0x0130 PSN 0x5e0128
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       remote address: LID 0000 QPN 0x0131 PSN 0xd89752
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       remote address: LID 0000 QPN 0x0132 PSN 0xe5fc16
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       remote address: LID 0000 QPN 0x0133 PSN 0x236787
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       remote address: LID 0000 QPN 0x0134 PSN 0xd9273e
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       remote address: LID 0000 QPN 0x0135 PSN 0x37cfd4
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       remote address: LID 0000 QPN 0x0136 PSN 0x3bff8f
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       remote address: LID 0000 QPN 0x0137 PSN 0x81f2bd
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       remote address: LID 0000 QPN 0x0138 PSN 0x575c43
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       remote address: LID 0000 QPN 0x0139 PSN 0x6cf53d
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       remote address: LID 0000 QPN 0x013a PSN 0xcaaf6f
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       remote address: LID 0000 QPN 0x013b PSN 0x346437
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
       remote address: LID 0000 QPN 0x013c PSN 0xcc5865
       GID: 00:00:00:00:00:00:00:00:00:00:255:255:192:168:04:226
      ---------------------------------------------------------------------------------------
       #bytes     #iterations    BW peak[Gb/sec]    BW average[Gb/sec]   MsgRate[Mpps]
       65536      10329004         0.00               180.47 		     0.344228
      ---------------------------------------------------------------------------------------
      deallocating GPU buffer 00007f447a600000
      destroying current CUDA Ctx
      Copy to Clipboard Toggle word wrap

Legal Notice

Copyright © 2025 Red Hat

OpenShift documentation is licensed under the Apache License 2.0 (https://www.apache.org/licenses/LICENSE-2.0).

Modified versions must remove all Red Hat trademarks.

Portions adapted from https://github.com/kubernetes-incubator/service-catalog/ with modifications by Red Hat.

Red Hat, Red Hat Enterprise Linux, the Red Hat logo, the Shadowman logo, JBoss, OpenShift, Fedora, the Infinity logo, and RHCE are trademarks of Red Hat, Inc., registered in the United States and other countries.

Linux® is the registered trademark of Linus Torvalds in the United States and other countries.

Java® is a registered trademark of Oracle and/or its affiliates.

XFS® is a trademark of Silicon Graphics International Corp. or its subsidiaries in the United States and/or other countries.

MySQL® is a registered trademark of MySQL AB in the United States, the European Union and other countries.

Node.js® is an official trademark of Joyent. Red Hat Software Collections is not formally related to or endorsed by the official Joyent Node.js open source or commercial project.

The OpenStack® Word Mark and OpenStack logo are either registered trademarks/service marks or trademarks/service marks of the OpenStack Foundation, in the United States and other countries and are used with the OpenStack Foundation’s permission. We are not affiliated with, endorsed or sponsored by the OpenStack Foundation, or the OpenStack community.

All other trademarks are the property of their respective owners.

Torna in cima
Red Hat logoGithubredditYoutubeTwitter

Formazione

Prova, acquista e vendi

Community

Informazioni sulla documentazione di Red Hat

Aiutiamo gli utenti Red Hat a innovarsi e raggiungere i propri obiettivi con i nostri prodotti e servizi grazie a contenuti di cui possono fidarsi. Esplora i nostri ultimi aggiornamenti.

Rendiamo l’open source più inclusivo

Red Hat si impegna a sostituire il linguaggio problematico nel codice, nella documentazione e nelle proprietà web. Per maggiori dettagli, visita il Blog di Red Hat.

Informazioni su Red Hat

Forniamo soluzioni consolidate che rendono più semplice per le aziende lavorare su piattaforme e ambienti diversi, dal datacenter centrale all'edge della rete.

Theme