Chapter 1. Fencing Pre-Configuration Copy linkLink copied to clipboard!
1.1. Configuring ACPI For Use with Integrated Fence Devices Copy linkLink copied to clipboard!
shutdown -h now
). Otherwise, if ACPI Soft-Off is enabled, an integrated fence device can take four or more seconds to turn off a node (refer to note that follows). In addition, if ACPI Soft-Off is enabled and a node panics or freezes during shutdown, an integrated fence device may not be able to turn off the node. Under those circumstances, fencing is delayed or unsuccessful. Consequently, when a node is fenced with an integrated fence device and ACPI Soft-Off is enabled, a cluster recovers slowly or requires administrative intervention to recover.
Note
chkconfig
management and verify that the node turns off immediately when fenced. The preferred way to disable ACPI Soft-Off is with chkconfig
management: however, if that method is not satisfactory for your cluster, you can disable ACPI Soft-Off with one of the following alternate methods:
- Changing the BIOS setting to "instant-off" or an equivalent setting that turns off the node without delay
Note
Disabling ACPI Soft-Off with the BIOS may not be possible with some computers. - Appending
acpi=off
to the kernel boot command line of the/boot/grub/grub.conf
fileImportant
This method completely disables ACPI; some computers do not boot correctly if ACPI is completely disabled. Use this method only if the other methods are not effective for your cluster.
- Section 1.1.1, “Disabling ACPI Soft-Off with
chkconfig
Management” — Preferred method - Section 1.1.2, “Disabling ACPI Soft-Off with the BIOS” — First alternate method
- Section 1.1.3, “Disabling ACPI Completely in the
grub.conf
File” — Second alternate method
1.1.1. Disabling ACPI Soft-Off with chkconfig Management Copy linkLink copied to clipboard!
chkconfig
management to disable ACPI Soft-Off either by removing the ACPI daemon (acpid
) from chkconfig
management or by turning off acpid
.
Note
chkconfig
management at each cluster node as follows:
- Run either of the following commands:
chkconfig --del acpid
— This command removesacpid
fromchkconfig
management.— OR —chkconfig --level 2345 acpid off
— This command turns offacpid
.
- Reboot the node.
- When the cluster is configured and running, verify that the node turns off immediately when fenced.
Note
You can fence the node with thefence_node
command or Conga.
1.1.2. Disabling ACPI Soft-Off with the BIOS Copy linkLink copied to clipboard!
chkconfig
management (Section 1.1.1, “Disabling ACPI Soft-Off with chkconfig
Management”). However, if the preferred method is not effective for your cluster, follow the procedure in this section.
Note
- Reboot the node and start the
BIOS CMOS Setup Utility
program. - Navigate to themenu (or equivalent power management menu).
- At the Example 1.1, “menu, set the function (or equivalent) to (or the equivalent setting that turns off the node by means of the power button without delay).
BIOS CMOS Setup Utility
: set to ” shows a menu with set to and set to .Note
The equivalents to, , and may vary among computers. However, the objective of this procedure is to configure the BIOS so that the computer is turned off by means of the power button without delay. - Exit the
BIOS CMOS Setup Utility
program, saving the BIOS configuration. - When the cluster is configured and running, verify that the node turns off immediately when fenced.
Note
You can fence the node with thefence_node
command or Conga.
Example 1.1. BIOS CMOS Setup Utility
: set to
1.1.3. Disabling ACPI Completely in the grub.conf File Copy linkLink copied to clipboard!
chkconfig
management (Section 1.1.1, “Disabling ACPI Soft-Off with chkconfig
Management”). If the preferred method is not effective for your cluster, you can disable ACPI Soft-Off with the BIOS power management (Section 1.1.2, “Disabling ACPI Soft-Off with the BIOS”). If neither of those methods is effective for your cluster, you can disable ACPI completely by appending acpi=off
to the kernel boot command line in the grub.conf
file.
Important
grub.conf
file of each cluster node as follows:
- Open
/boot/grub/grub.conf
with a text editor. - Append
acpi=off
to the kernel boot command line in/boot/grub/grub.conf
(see Example 1.2, “Kernel Boot Command Line withacpi=off
Appended to It”). - Reboot the node.
- When the cluster is configured and running, verify that the node turns off immediately when fenced.
Note
You can fence the node with thefence_node
command or Conga.
Example 1.2. Kernel Boot Command Line with acpi=off
Appended to It
acpi=off
has been appended to the kernel boot command line — the line starting with "kernel /vmlinuz-2.6.32-193.el6.x86_64.img".
1.2. SELinux Copy linkLink copied to clipboard!
enforcing
state with the SELinux policy type set to targeted
.
Note
fenced_can_network_connect
is persistently set to on
. This allows the fence_xvm
fencing agent to work properly, enabling the system to fence virtual machines.
Chapter 2. Configuring Fencing with the ccs Command Copy linkLink copied to clipboard!
ccs
cluster configuration command. The ccs
command allows an administrator to create, modify and view the cluster.conf
cluster configuration file. You can use the ccs
command to configure a cluster configuration file on a local file system or on a remote node. Using the ccs
command, an administrator can also start and stop the cluster services on one or all of the nodes in a configured cluster.
ccs
command.
Note
Note
cluster.conf
elements and attributes. For a comprehensive list and description of cluster.conf
elements and attributes, see the cluster schema at /usr/share/cluster/cluster.rng
, and the annotated schema at /usr/share/doc/cman-X.Y.ZZ/cluster_conf.html
(for example /usr/share/doc/cman-3.0.12/cluster_conf.html
).
2.1. Configuring Fence Devices Copy linkLink copied to clipboard!
- The
post_fail_delay
attribute is the number of seconds the fence daemon (fenced
) waits before fencing a node (a member of the fence domain) after the node has failed. Thepost_fail_delay
default value is0
. Its value may be varied to suit cluster and network performance. - The
post-join_delay
attribute is the number of seconds the fence daemon (fenced
) waits before fencing a node after the node joins the fence domain. Thepost_join_delay
default value is6
. A typical setting forpost_join_delay
is between 20 and 30 seconds, but can vary according to cluster and network performance.
post_fail_delay
and post_join_delay
attributes with the --setfencedaemon
option of the ccs
command. Note, however, that executing the ccs --setfencedaemon
command overwrites all existing fence daemon properties.
post_fail_delay
attribute, execute the following command. This command will overwrite the values of all other existing fence daemon properties that you can set with this command.
ccs -h host --setfencedaemon post_fail_delay=value
ccs -h host --setfencedaemon post_fail_delay=value
post_join_delay
attribute, execute the following command. This command will overwrite the values of all other existing fence daemon properties that you can set with this command.
ccs -h host --setfencedaemon post_join_delay=value
ccs -h host --setfencedaemon post_join_delay=value
post_join_delay
attribute and the post_fail_delay
attribute, execute the following command:
ccs -h host --setfencedaemon post_fail_delay=value post_join_delay=value
ccs -h host --setfencedaemon post_fail_delay=value post_join_delay=value
Note
post_join_delay
and post_fail_delay
attributes as well as the additional fence daemon properties you can modify, see the fenced(8) man page and see the cluster schema at /usr/share/cluster/cluster.rng
, and the annotated schema at /usr/share/doc/cman-X.Y.ZZ/cluster_conf.html
.
ccs -h host --addfencedev devicename [fencedeviceoptions]
ccs -h host --addfencedev
devicename
[fencedeviceoptions]
node-01
named myfence
with an IP address of apc_ip_example
, a login of login_example
, and a password of password_example
, execute the following command:
ccs -h node-01 --addfencedev myfence agent=fence_apc ipaddr=apc_ip_example login=login_example passwd=password_example
ccs -h node-01 --addfencedev myfence agent=fence_apc ipaddr=apc_ip_example login=login_example passwd=password_example
fencedevices
section of the cluster.conf
configuration file after you have added this APC fence device:
<fencedevices> <fencedevice agent="fence_apc" ipaddr="apc_ip_example" login="login_example" name="myfence" passwd="password_example"/> </fencedevices>
<fencedevices>
<fencedevice agent="fence_apc" ipaddr="apc_ip_example" login="login_example" name="myfence" passwd="password_example"/>
</fencedevices>
ccs
command to print a list of available fence devices and options or to print a list of fence devices currently configured for your cluster, see Section 2.2, “Listing Fence Devices and Fence Device Options”.
ccs -h host --rmfencedev fence_device_name
ccs -h host --rmfencedev fence_device_name
myfence
from the cluster configuration file on cluster node node-01
, execute the following command:
ccs -h node-01 --rmfencedev myfence
ccs -h node-01 --rmfencedev myfence
2.2. Listing Fence Devices and Fence Device Options Copy linkLink copied to clipboard!
ccs
command to print a list of available fence devices and to print a list of options for each available fence type. You can also use the ccs
command to print a list of fence devices currently configured for your cluster.
ccs -h host --lsfenceopts
ccs -h host --lsfenceopts
node-01
, showing sample output.
ccs -h host --lsfenceopts fence_type
ccs -h host --lsfenceopts fence_type
fence_wti
fence agent.
ccs -h host --lsfencedev
ccs -h host --lsfencedev
2.3. Configuring Fencing for Cluster Members Copy linkLink copied to clipboard!
2.3.1. Configuring a Single Power-Based Fence Device for a Node Copy linkLink copied to clipboard!
apc
, which uses the fence_apc
fencing agent.
- Add a fence method for the node, providing a name for the fence method.
ccs -h host --addmethod method node
ccs -h host --addmethod method node
Copy to Clipboard Copied! Toggle word wrap Toggle overflow For example, to configure a fence method namedAPC
for the nodenode-01.example.com
in the configuration file on the cluster nodenode-01.example.com
, execute the following command:ccs -h node01.example.com --addmethod APC node01.example.com
ccs -h node01.example.com --addmethod APC node01.example.com
Copy to Clipboard Copied! Toggle word wrap Toggle overflow - Add a fence instance for the method. You must specify the fence device to use for the node, the node this instance applies to, the name of the method, and any options for this method that are specific to this node:
ccs -h host --addfenceinst fencedevicename node method [options]
ccs -h host --addfenceinst fencedevicename node method [options]
Copy to Clipboard Copied! Toggle word wrap Toggle overflow For example, to configure a fence instance in the configuration file on the cluster nodenode-01.example.com
that uses the APC switch power port 1 on the fence device namedapc
to fence cluster nodenode-01.example.com
using the method namedAPC
, execute the following command:ccs -h node01.example.com --addfenceinst apc node01.example.com APC port=1
ccs -h node01.example.com --addfenceinst apc node01.example.com APC port=1
Copy to Clipboard Copied! Toggle word wrap Toggle overflow
APC
. The device for the fence method specifies apc
as the device name, which is a device previously configured with the --addfencedev
option, as described in Section 2.1, “Configuring Fence Devices”. Each node is configured with a unique APC switch power port number: The port number for node-01.example.com
is 1
, the port number for node-02.example.com
is 2
, and the port number for node-03.example.com
is 3
.
cluster.conf
After Adding Power-Based Fence Methods ” shows a cluster.conf
configuration file after you have added these fencing methods and instances to each node in the cluster.
Example 2.1. cluster.conf
After Adding Power-Based Fence Methods
2.3.2. Configuring a Single Storage-Based Fence Device for a Node Copy linkLink copied to clipboard!
on
or enable
.
fence_node
(8) man page.
sanswitch1
, which uses the fence_sanbox2
fencing agent.
- Add a fence method for the node, providing a name for the fence method.
ccs -h host --addmethod method node
ccs -h host --addmethod method node
Copy to Clipboard Copied! Toggle word wrap Toggle overflow For example, to configure a fence method namedSAN
for the nodenode-01.example.com
in the configuration file on the cluster nodenode-01.example.com
, execute the following command:ccs -h node01.example.com --addmethod SAN node01.example.com
ccs -h node01.example.com --addmethod SAN node01.example.com
Copy to Clipboard Copied! Toggle word wrap Toggle overflow - Add a fence instance for the method. You must specify the fence device to use for the node, the node this instance applies to, the name of the method, and any options for this method that are specific to this node:
ccs -h host --addfenceinst fencedevicename node method [options]
ccs -h host --addfenceinst fencedevicename node method [options]
Copy to Clipboard Copied! Toggle word wrap Toggle overflow For example, to configure a fence instance in the configuration file on the cluster nodenode-01.example.com
that uses the SAN switch power port 11 on the fence device namedsanswitch1
to fence cluster nodenode-01.example.com
using the method namedSAN
, execute the following command:ccs -h node01.example.com --addfenceinst sanswitch1 node01.example.com SAN port=11
ccs -h node01.example.com --addfenceinst sanswitch1 node01.example.com SAN port=11
Copy to Clipboard Copied! Toggle word wrap Toggle overflow - To configure unfencing for the storage based fence device on this node, execute the following command:
ccs -h host --addunfence fencedevicename node action=on|off
ccs -h host --addunfence fencedevicename node action=on|off
Copy to Clipboard Copied! Toggle word wrap Toggle overflow
SAN
. The device for the fence method specifies sanswitch
as the device name, which is a device previously configured with the --addfencedev option, as described in Section 2.1, “Configuring Fence Devices”. Each node is configured with a unique SAN physical port number: The port number for node-01.example.com
is 11
, the port number for node-02.example.com
is 12
, and the port number for node-03.example.com
is 13
.
cluster.conf
After Adding Storage-Based Fence Methods ” shows a cluster.conf
configuration file after you have added fencing methods, fencing instances, and unfencing to each node in the cluster.
Example 2.2. cluster.conf
After Adding Storage-Based Fence Methods
2.3.3. Configuring a Backup Fence Device Copy linkLink copied to clipboard!
Note
ccs
command is the primary fencing method, and the second method you configure is the backup fencing method. To change the order, you can remove the primary fencing method from the configuration file, then add that method back.
ccs -h host --lsfenceinst [node]
ccs -h host --lsfenceinst [node]
apc
, which uses the fence_apc
fencing agent, and a backup fencing device that uses a fence device named sanswitch1
, which uses the fence_sanbox2
fencing agent. Since the sanswitch1
device is a storage-based fencing agent, you will need to configure unfencing for that device as well.
- Add a primary fence method for the node, providing a name for the fence method.
ccs -h host --addmethod method node
ccs -h host --addmethod method node
Copy to Clipboard Copied! Toggle word wrap Toggle overflow For example, to configure a fence method namedAPC
as the primary method for the nodenode-01.example.com
in the configuration file on the cluster nodenode-01.example.com
, execute the following command:ccs -h node01.example.com --addmethod APC node01.example.com
ccs -h node01.example.com --addmethod APC node01.example.com
Copy to Clipboard Copied! Toggle word wrap Toggle overflow - Add a fence instance for the primary method. You must specify the fence device to use for the node, the node this instance applies to, the name of the method, and any options for this method that are specific to this node:
ccs -h host --addfenceinst fencedevicename node method [options]
ccs -h host --addfenceinst fencedevicename node method [options]
Copy to Clipboard Copied! Toggle word wrap Toggle overflow For example, to configure a fence instance in the configuration file on the cluster nodenode-01.example.com
that uses the APC switch power port 1 on the fence device namedapc
to fence cluster nodenode-01.example.com
using the method namedAPC
, execute the following command:ccs -h node01.example.com --addfenceinst apc node01.example.com APC port=1
ccs -h node01.example.com --addfenceinst apc node01.example.com APC port=1
Copy to Clipboard Copied! Toggle word wrap Toggle overflow - Add a backup fence method for the node, providing a name for the fence method.
ccs -h host --addmethod method node
ccs -h host --addmethod method node
Copy to Clipboard Copied! Toggle word wrap Toggle overflow For example, to configure a backup fence method namedSAN
for the nodenode-01.example.com
in the configuration file on the cluster nodenode-01.example.com
, execute the following command:ccs -h node01.example.com --addmethod SAN node01.example.com
ccs -h node01.example.com --addmethod SAN node01.example.com
Copy to Clipboard Copied! Toggle word wrap Toggle overflow - Add a fence instance for the backup method. You must specify the fence device to use for the node, the node this instance applies to, the name of the method, and any options for this method that are specific to this node:
ccs -h host --addfenceinst fencedevicename node method [options]
ccs -h host --addfenceinst fencedevicename node method [options]
Copy to Clipboard Copied! Toggle word wrap Toggle overflow For example, to configure a fence instance in the configuration file on the cluster nodenode-01.example.com
that uses the SAN switch power port 11 on the fence device namedsanswitch1
to fence cluster nodenode-01.example.com
using the method namedSAN
, execute the following command:ccs -h node01.example.com --addfenceinst sanswitch1 node01.example.com SAN port=11
ccs -h node01.example.com --addfenceinst sanswitch1 node01.example.com SAN port=11
Copy to Clipboard Copied! Toggle word wrap Toggle overflow - Since the
sanswitch1
device is a storage-based device, you must configure unfencing for this device.ccs -h node01.example.com --addunfence sanswitch1 node01.example.com port=11 action=on
ccs -h node01.example.com --addunfence sanswitch1 node01.example.com port=11 action=on
Copy to Clipboard Copied! Toggle word wrap Toggle overflow
cluster.conf
After Adding Backup Fence Methods ” shows a cluster.conf
configuration file after you have added a power-based primary fencing method and a storage-based backup fencing method to each node in the cluster.
Example 2.3. cluster.conf
After Adding Backup Fence Methods
Note
2.3.4. Configuring a Node with Redundant Power Copy linkLink copied to clipboard!
action
attribute of off
before configuring each of the devices with an action
attribute of on
.
- Before you can configure fencing for a node with redundant power, you must configure each of the power switches as a fence device for the cluster. For information on configuring fence devices, see Section 2.1, “Configuring Fence Devices”.To print a list of fence devices currently configured for your cluster, execute the following command:
ccs -h host --lsfencedev
ccs -h host --lsfencedev
Copy to Clipboard Copied! Toggle word wrap Toggle overflow - Add a fence method for the node, providing a name for the fence method.
ccs -h host --addmethod method node
ccs -h host --addmethod method node
Copy to Clipboard Copied! Toggle word wrap Toggle overflow For example, to configure a fence method namedAPC-dual
for the nodenode-01.example.com
in the configuration file on the cluster nodenode-01.example.com
, execute the following command:ccs -h node01.example.com --addmethod APC-dual node01.example.com
ccs -h node01.example.com --addmethod APC-dual node01.example.com
Copy to Clipboard Copied! Toggle word wrap Toggle overflow - Add a fence instance for the first power supply to the fence method. You must specify the fence device to use for the node, the node this instance applies to, the name of the method, and any options for this method that are specific to this node. At this point you configure the
action
attribute asoff
.ccs -h host --addfenceinst fencedevicename node method [options] action=off
ccs -h host --addfenceinst fencedevicename node method [options] action=off
Copy to Clipboard Copied! Toggle word wrap Toggle overflow For example, to configure a fence instance in the configuration file on the cluster nodenode-01.example.com
that uses the APC switch power port 1 on the fence device namedapc1
to fence cluster nodenode-01.example.com
using the method namedAPC-dual
, and setting theaction
attribute tooff
, execute the following command:ccs -h node01.example.com --addfenceinst apc1 node01.example.com APC-dual port=1 action=off
ccs -h node01.example.com --addfenceinst apc1 node01.example.com APC-dual port=1 action=off
Copy to Clipboard Copied! Toggle word wrap Toggle overflow - Add a fence instance for the second power supply to the fence method. You must specify the fence device to use for the node, the node this instance applies to, the name of the method, and any options for this method that are specific to this node. At this point you configure the
action
attribute asoff
for this instance as well:ccs -h host --addfenceinst fencedevicename node method [options] action=off
ccs -h host --addfenceinst fencedevicename node method [options] action=off
Copy to Clipboard Copied! Toggle word wrap Toggle overflow For example, to configure a second fence instance in the configuration file on the cluster nodenode-01.example.com
that uses the APC switch power port 1 on the fence device namedapc2
to fence cluster nodenode-01.example.com
using the same method as you specified for the first instance namedAPC-dual
, and setting theaction
attribute tooff
, execute the following command:ccs -h node01.example.com --addfenceinst apc2 node01.example.com APC-dual port=1 action=off
ccs -h node01.example.com --addfenceinst apc2 node01.example.com APC-dual port=1 action=off
Copy to Clipboard Copied! Toggle word wrap Toggle overflow - At this point, add another fence instance for the first power supply to the fence method, configuring the
action
attribute ason
. You must specify the fence device to use for the node, the node this instance applies to, the name of the method, and any options for this method that are specific to this node, and specifying theaction
attribute ason
:ccs -h host --addfenceinst fencedevicename node method [options] action=on
ccs -h host --addfenceinst fencedevicename node method [options] action=on
Copy to Clipboard Copied! Toggle word wrap Toggle overflow For example, to configure a fence instance in the configuration file on the cluster nodenode-01.example.com
that uses the APC switch power port 1 on the fence device namedapc1
to fence cluster nodenode-01.example.com
using the method namedAPC-dual
, and setting theaction
attribute toon
, execute the following command:ccs -h node01.example.com --addfenceinst apc1 node01.example.com APC-dual port=1 action=on
ccs -h node01.example.com --addfenceinst apc1 node01.example.com APC-dual port=1 action=on
Copy to Clipboard Copied! Toggle word wrap Toggle overflow - Add another fence instance for second power supply to the fence method, specifying the
action
attribute ason
for this instance. You must specify the fence device to use for the node, the node this instance applies to, the name of the method, and any options for this method that are specific to this node as well as theaction
attribute ofon
.ccs -h host --addfenceinst fencedevicename node method [options] action=on
ccs -h host --addfenceinst fencedevicename node method [options] action=on
Copy to Clipboard Copied! Toggle word wrap Toggle overflow For example, to configure a second fence instance in the configuration file on the cluster nodenode-01.example.com
that uses the APC switch power port 1 on the fence device namedapc2
to fence cluster nodenode-01.example.com
using the same method as you specified for the first instance namedAPC-dual
and setting theaction
attribute toon
, execute the following command:ccs -h node01.example.com --addfenceinst apc2 node01.example.com APC-dual port=1 action=on
ccs -h node01.example.com --addfenceinst apc2 node01.example.com APC-dual port=1 action=on
Copy to Clipboard Copied! Toggle word wrap Toggle overflow
cluster.conf
After Adding Dual-Power Fencing ” shows a cluster.conf
configuration file after you have added fencing for two power supplies for each node in a cluster.
Example 2.4. cluster.conf
After Adding Dual-Power Fencing
2.3.5. Testing the Fence Configuration Copy linkLink copied to clipboard!
fence_check
utility.
fence_check
(8) man page.
2.3.6. Removing Fence Methods and Fence Instances Copy linkLink copied to clipboard!
ccs -h host --rmmethod method node
ccs -h host --rmmethod method node
APC
that you have configured for node01.example.com
from the cluster configuration file on cluster node node01.example.com
, execute the following command:
ccs -h node01.example.com --rmmethod APC node01.example.com
ccs -h node01.example.com --rmmethod APC node01.example.com
ccs -h host --rmfenceinst fencedevicename node method
ccs -h host --rmfenceinst fencedevicename node method
apc1
from the method named APC-dual
configured for node01.example.com
from the cluster configuration file on cluster node node01.example.com
, execute the following command:
ccs -h node01.example.com --rmfenceinst apc1 node01.example.com APC-dual
ccs -h node01.example.com --rmfenceinst apc1 node01.example.com APC-dual
Chapter 3. Configuring Fencing with Conga Copy linkLink copied to clipboard!
Note
3.1. Configuring Fence Daemon Properties Copy linkLink copied to clipboard!
- Theparameter is the number of seconds the fence daemon (
fenced
) waits before fencing a node (a member of the fence domain) after the node has failed. The default value is0
. Its value may be varied to suit cluster and network performance. - Theparameter is the number of seconds the fence daemon (
fenced
) waits before fencing a node after the node joins the fence domain. The default value is6
. A typical setting for is between 20 and 30 seconds, but can vary according to cluster and network performance.
Note
3.2. Configuring Fence Devices Copy linkLink copied to clipboard!
- Creating fence devices — Refer to Section 3.2.1, “Creating a Fence Device”. Once you have created and named a fence device, you can configure the fence devices for each node in the cluster, as described in Section 3.3, “Configuring Fencing for Cluster Members”.
- Updating fence devices — Refer to Section 3.2.2, “Modifying a Fence Device”.
- Deleting fence devices — Refer to Section 3.2.3, “Deleting a Fence Device”.
Note
Figure 3.1. luci fence devices configuration page
3.2.1. Creating a Fence Device Copy linkLink copied to clipboard!
- From the Add Fence Device (Instance) dialog box. From this dialog box, select the type of fence device to configure.configuration page, click . Clicking displays the
- Specify the information in the Add Fence Device (Instance) dialog box according to the type of fence device. In some cases you will need to specify additional node-specific parameters for the fence device when you configure fencing for the individual nodes.
- Click.
3.2.2. Modifying a Fence Device Copy linkLink copied to clipboard!
- From theconfiguration page, click on the name of the fence device to modify. This displays the dialog box for that fence device, with the values that have been configured for the device.
- To modify the fence device, enter changes to the parameters displayed.
- Clickand wait for the configuration to be updated.
3.2.3. Deleting a Fence Device Copy linkLink copied to clipboard!
Note
- From theconfiguration page, check the box to the left of the fence device or devices to select the devices to delete.
- Clickand wait for the configuration to be updated. A message appears indicating which devices are being deleted.
3.3. Configuring Fencing for Cluster Members Copy linkLink copied to clipboard!
3.3.1. Configuring a Single Fence Device for a Node Copy linkLink copied to clipboard!
- From the cluster-specific page, you can configure fencing for the nodes in the cluster by clicking on luci page.along the top of the cluster display. This displays the nodes that constitute the cluster. This is also the default page that appears when you click on the cluster name beneath from the menu on the left side of the
- Click on a node name. Clicking a link for a node causes a page to be displayed for that link showing how that node is configured.The node-specific page displays any services that are currently running on the node, as well as any failover domains of which this node is a member. You can modify an existing failover domain by clicking on its name.
- On the node-specific page, under, click . This displays the dialog box.
- Enter afor the fencing method that you are configuring for this node. This is an arbitrary name that will be used by Red Hat High Availability Add-On; it is not the same as the DNS name for the device.
- Click. This displays the node-specific screen that now displays the method you have just added under .
- Configure a fence instance for this method by clicking the Section 3.2.1, “Creating a Fence Device”.button that appears beneath the fence method. This displays the drop-down menu from which you can select a fence device you have previously configured, as described in
- Select a fence device for this method. If this fence device requires that you configure node-specific parameters, the display shows the parameters to configure.
Note
For non-power fence methods (that is, SAN/storage fencing),is selected by default on the node-specific parameters display. This ensures that a fenced node's access to storage is not re-enabled until the node has been rebooted. For information on unfencing a node, see thefence_node
(8) man page. - Click. This returns you to the node-specific screen with the fence method and fence instance displayed.
3.3.2. Configuring a Backup Fence Device Copy linkLink copied to clipboard!
- Use the procedure provided in Section 3.3.1, “Configuring a Single Fence Device for a Node” to configure the primary fencing method for a node.
- Beneath the display of the primary method you defined, click.
- Enter a name for the backup fencing method that you are configuring for this node and click. This displays the node-specific screen that now displays the method you have just added, below the primary fence method.
- Configure a fence instance for this method by clicking Section 3.2.1, “Creating a Fence Device”.. This displays a drop-down menu from which you can select a fence device you have previously configured, as described in
- Select a fence device for this method. If this fence device requires that you configure node-specific parameters, the display shows the parameters to configure.
- Click. This returns you to the node-specific screen with the fence method and fence instance displayed.
3.3.3. Configuring a Node with Redundant Power Copy linkLink copied to clipboard!
- Before you can configure fencing for a node with redundant power, you must configure each of the power switches as a fence device for the cluster. For information on configuring fence devices, see Section 3.2, “Configuring Fence Devices”.
- From the cluster-specific page, click on luci page.along the top of the cluster display. This displays the nodes that constitute the cluster. This is also the default page that appears when you click on the cluster name beneath from the menu on the left side of the
- Click on a node name. Clicking a link for a node causes a page to be displayed for that link showing how that node is configured.
- On the node-specific page, click.
- Enter a name for the fencing method that you are configuring for this node.
- Click. This displays the node-specific screen that now displays the method you have just added under .
- Configure the first power supply as a fence instance for this method by clicking Section 3.2.1, “Creating a Fence Device”.. This displays a drop-down menu from which you can select one of the power fencing devices you have previously configured, as described in
- Select one of the power fence devices for this method and enter the appropriate parameters for this device.
- Click. This returns you to the node-specific screen with the fence method and fence instance displayed.
- Under the same fence method for which you have configured the first power fencing device, click Section 3.2.1, “Creating a Fence Device”.. This displays a drop-down menu from which you can select the second power fencing devices you have previously configured, as described in
- Select the second of the power fence devices for this method and enter the appropriate parameters for this device.
- . This returns you to the node-specific screen with the fence methods and fence instances displayed, showing that each device will power the system off in sequence and power the system on in sequence. This is shown in
Figure 3.2. Dual-Power Fencing Configuration
3.3.4. Testing the Fence Configuration Copy linkLink copied to clipboard!
fence_check
utility.
fence_check
(8) man page.
Chapter 4. Fence Devices Copy linkLink copied to clipboard!
4.1. APC Power Switch over Telnet and SSH Copy linkLink copied to clipboard!
fence_apc
, the fence agent for APC over telnet/SSH.
luci Field | cluster.conf Attribute | Description |
---|---|---|
Name | name | A name for the APC device connected to the cluster into which the fence daemon logs by means of telnet/ssh. |
IP Address or Hostname | ipaddr | The IP address or host name assigned to the device. |
IP Port (optional) | ipport | The TCP port to use to connect to the device. The default port is 23, or 22 if Use SSH is selected. |
Login | login | The login name used to access the device. |
Password | passwd | The password used to authenticate the connection to the device. |
Password Script (optional) | passwd_script | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Power Wait (seconds) | power_wait | Number of seconds to wait after issuing a power off or power on command. |
Power Timeout (seconds) | power_timeout | Number of seconds to continue testing for a status change after issuing a power off or power on command. The default value is 20. |
Shell Timeout (seconds) | shell_timeout | Number of seconds to wait for a command prompt after issuing a command. The default value is 3. |
Login Timeout (seconds) | login_timeout | Number of seconds to wait for a command prompt after login. The default value is 5. |
Times to Retry Power On Operation | retry_on | Number of attempts to retry a power on operation. The default value is 1. |
Port | port | The port. |
Switch (optional) | switch | The switch number for the APC switch that connects to the node when you have multiple daisy-chained switches. |
Delay (optional) | delay | The number of seconds to wait before fencing is started. The default value is 0. |
Use SSH | secure | Indicates that system will use SSH to access the device. When using SSH, you must specify either a password, a password script, or an identity file. |
SSH Options | ssh_options | SSH options to use. The default value is -1 -c blowfish . |
Path to SSH Identity File | identity_file | The identity file for SSH. |
Figure 4.1. APC Power Switch
ccs -f cluster.conf --addfencedev apc agent=fence_apc ipaddr=192.168.0.1 login=root passwd=password123
ccs -f cluster.conf --addfencedev apc agent=fence_apc ipaddr=192.168.0.1 login=root passwd=password123
cluster.conf
entry for the fence_apc
device:
<fencedevices> <fencedevice agent="fence_apc" name="apc" ipaddr="apc-telnet.example.com" login="root" passwd="password123"/> </fencedevices>
<fencedevices>
<fencedevice agent="fence_apc" name="apc" ipaddr="apc-telnet.example.com" login="root" passwd="password123"/>
</fencedevices>
4.2. APC Power Switch over SNMP Copy linkLink copied to clipboard!
fence_apc_snmp
, the fence agent for APC that logs into the SNP device by means of the SNMP protocol.
luci Field | cluster.conf Attribute | Description |
---|---|---|
Name | name | A name for the APC device connected to the cluster into which the fence daemon logs by means of the SNMP protocol. |
IP Address or Hostname | ipaddr | The IP address or host name assigned to the device. |
UDP/TCP port | udpport | The UDP/TCP port to use for connection with the device; the default value is 161. |
Login | login | The login name used to access the device. |
Password | passwd | The password used to authenticate the connection to the device. |
Password Script (optional) | passwd_script | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
SNMP Version | snmp_version | The SNMP version to use (1, 2c, 3); the default value is 1. |
SNMP Community | community | The SNMP community string; the default value is private . |
SNMP Security Level | snmp_sec_level | The SNMP security level (noAuthNoPriv, authNoPriv, authPriv). |
SNMP Authentication Protocol | snmp_auth_prot | The SNMP authentication protocol (MD5, SHA). |
SNMP Privacy Protocol | snmp_priv_prot | The SNMP privacy protocol (DES, AES). |
SNMP Privacy Protocol Password | snmp_priv_passwd | The SNMP privacy protocol password. |
SNMP Privacy Protocol Script | snmp_priv_passwd_script | The script that supplies a password for SNMP privacy protocol. Using this supersedes the | parameter.
Power Wait (seconds) | power_wait | Number of seconds to wait after issuing a power off or power on command. |
Power Timeout (seconds) | power_timeout | Number of seconds to continue testing for a status change after issuing a power off or power on command. The default value is 20. |
Shell Timeout (seconds) | shell_timeout | Number of seconds to wait for a command prompt after issuing a command. The default value is 3. |
Login Timeout (seconds) | login_timeout | Number of seconds to wait for a command prompt after login. The default value is 5. |
Times to Retry Power On Operation | retry_on | Number of attempts to retry a power on operation. The default value is 1. |
Port (Outlet) Number | port | The port. |
Delay (optional) | delay | The number of seconds to wait before fencing is started. The default value is 0. |
Figure 4.2. APC Power Switch over SNMP
cluster.conf
entry for the fence_apc_snmp
device:
<fencedevice> <fencedevice agent="fence_apc_snmp" community="private" ipaddr="192.168.0.1" login="root" \ name="apcpwsnmptst1" passwd="password123" power_wait="60" snmp_priv_passwd="password123"/> </fencedevices>
<fencedevice>
<fencedevice agent="fence_apc_snmp" community="private" ipaddr="192.168.0.1" login="root" \
name="apcpwsnmptst1" passwd="password123" power_wait="60" snmp_priv_passwd="password123"/>
</fencedevices>
4.3. Brocade Fabric Switch Copy linkLink copied to clipboard!
fence_brocade
, the fence agent for Brocade FC switches.
luci Field | cluster.conf Attribute | Description |
---|---|---|
Name | name | A name for the Brocade device connected to the cluster. |
IP Address or Hostname | ipaddr | The IP address or host name assigned to the device. |
Login | login | The login name used to access the device. |
Password | passwd | The password used to authenticate the connection to the device. |
Password Script (optional) | passwd_script | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Force IP Family | inet4_only, inet6_only | Force the agent to use IPv4 or IPv6 addresses only |
Force Command Prompt | cmd_prompt | The command prompt to use. The default value is '\$'. |
Power Wait (seconds) | power_wait | Number of seconds to wait after issuing a power off or power on command. |
Power Timeout (seconds) | power_timeout | Number of seconds to continue testing for a status change after issuing a power off or power on command. The default value is 20. |
Shell Timeout (seconds) | shell_timeout | Number of seconds to wait for a command prompt after issuing a command. The default value is 3. |
Login Timeout (seconds) | login_timeout | Number of seconds to wait for a command prompt after login. The default value is 5. |
Times to Retry Power On Operation | retry_on | Number of attempts to retry a power on operation. The default value is 1. |
Port | port | The switch outlet number. |
Delay (optional) | delay | The number of seconds to wait before fencing is started. The default value is 0. |
Use SSH | secure | Indicates that the system will use SSH to access the device. When using SSH, you must specify either a password, a password script, or an identity file. |
SSH Options | ssh_options | SSH options to use. The default value is -1 -c blowfish . |
Path to SSH Identity File | identity_file | The identity file for SSH. |
Unfencing | unfence section of the cluster configuration file | When enabled, this ensures that a fenced node is not re-enabled until the node has been rebooted. This is necessary for non-power fence methods (that is, SAN/storage fencing). When you configure a device that requires unfencing, the cluster must first be stopped and the full configuration including devices and unfencing must be added before the cluster is started. For more information about unfencing a node, see the fence_node (8) man page. |
Figure 4.3. Brocade Fabric Switch
ccs -f cluster.conf --addfencedev brocadetest agent=fence_brocade ipaddr=brocadetest.example.com login=root \ passwd=password123
ccs -f cluster.conf --addfencedev brocadetest agent=fence_brocade ipaddr=brocadetest.example.com login=root \
passwd=password123
cluster.conf
entry for the fence_brocade
device:
<fencedevices> <fencedevice agent="fence_brocade" ipaddr="brocadetest.example.com" login="brocadetest" \ name="brocadetest" passwd="brocadetest"/> </fencedevices>
<fencedevices>
<fencedevice agent="fence_brocade" ipaddr="brocadetest.example.com" login="brocadetest" \
name="brocadetest" passwd="brocadetest"/>
</fencedevices>
4.4. Cisco MDS Copy linkLink copied to clipboard!
fence_cisco_mds
, the fence agent for Cisco MDS.
luci Field | cluster.conf Attribute | Description |
---|---|---|
Name | name | A name for the Cisco MDS 9000 series device with SNMP enabled. |
IP Address or Hostname | ipaddr | The IP address or host name assigned to the device. |
UDP/TCP port (optional) | udpport | The UDP/TCP port to use for connection with the device; the default value is 161. |
Login | login | The login name used to access the device. |
Password | passwd | The password used to authenticate the connection to the device. |
Password Script (optional) | passwd_script | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
SNMP Version | snmp_version | The SNMP version to use (1, 2c, 3). |
SNMP Community | community | The SNMP community string. |
SNMP Security Level | snmp_sec_level | The SNMP security level (noAuthNoPriv, authNoPriv, authPriv). |
SNMP Authentication Protocol | snmp_auth_prot | The SNMP authentication protocol (MD5, SHA). |
SNMP Privacy Protocol | snmp_priv_prot | The SNMP privacy protocol (DES, AES). |
SNMP Privacy Protocol Password | snmp_priv_passwd | The SNMP privacy protocol password. |
SNMP Privacy Protocol Script | snmp_priv_passwd_script | The script that supplies a password for SNMP privacy protocol. Using this supersedes the | parameter.
Power Wait (seconds) | power_wait | Number of seconds to wait after issuing a power off or power on command. |
Power Timeout (seconds) | power_timeout | Number of seconds to continue testing for a status change after issuing a power off or power on command. The default value is 20. |
Shell Timeout (seconds) | shell_timeout | Number of seconds to wait for a command prompt after issuing a command. The default value is 3. |
Login Timeout (seconds) | login_timeout | Number of seconds to wait for a command prompt after login. The default value is 5. |
Times to Retry Power On Operation | retry_on | Number of attempts to retry a power on operation. The default value is 1. |
Port (Outlet) Number | port | The port. |
Delay (optional) | delay | The number of seconds to wait before fencing is started. The default value is 0. |
Figure 4.4. Cisco MDS
ccs -f cluster.conf --addfencedev mds agent=fence_cisco_mds ipaddr=192.168.0.1 name=ciscomdstest1 login=root \ passwd=password123 power_wait=60 snmp_priv_passwd=password123 udpport=161
ccs -f cluster.conf --addfencedev mds agent=fence_cisco_mds ipaddr=192.168.0.1 name=ciscomdstest1 login=root \
passwd=password123 power_wait=60 snmp_priv_passwd=password123 udpport=161
cluster.conf
entry for the fence_cisco_mds
device:
4.5. Cisco UCS Copy linkLink copied to clipboard!
fence_cisco_ucs
, the fence agent for Cisco UCS.
luci Field | cluster.conf Attribute | Description |
---|---|---|
Name | name | A name for the Cisco UCS device. |
IP Address or Hostname | ipaddr | The IP address or host name assigned to the device. |
IP port (optional) | ipport | The TCP port to use to connect to the device. |
Login | login | The login name used to access the device. |
Password | passwd | The password used to authenticate the connection to the device. |
Password Script (optional) | passwd_script | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Use SSL | ssl | Use SSL connections to communicate with the device. |
Sub-Organization | suborg | Additional path needed to access suborganization. |
Power Wait (seconds) | power_wait | Number of seconds to wait after issuing a power off or power on command. |
Power Timeout (seconds) | power_timeout | Number of seconds to continue testing for a status change after issuing a power off or power on command. The default value is 20. |
Shell Timeout (seconds) | shell_timeout | Number of seconds to wait for a command prompt after issuing a command. The default value is 3. |
Login Timeout (seconds) | login_timeout | Number of seconds to wait for a command prompt after login. The default value is 5. |
Times to Retry Power On Operation | retry_on | Number of attempts to retry a power on operation. The default value is 1. |
Port (Outlet) Number | port | Name of virtual machine. |
Delay (optional) | delay | The number of seconds to wait before fencing is started. The default value is 0. |
Figure 4.5. Cisco UCS
ccs -f cluster.conf --addfencedev ucs agent=fence_cisco_ucs ipaddr=192.168.0.1 login=root passwd=password123 \ suborg=/org-RHEL/org-Fence/
ccs -f cluster.conf --addfencedev ucs agent=fence_cisco_ucs ipaddr=192.168.0.1 login=root passwd=password123 \
suborg=/org-RHEL/org-Fence/
cluster.conf
entry for the fence_cisco_ucs
device as created using either Conga or ccs
:
<fencedevices> <fencedevice agent="fence_cisco_ucs" ipaddr="192.168.0.1" login="root" name="ciscoucstest1" \ passwd="password123" power_wait="60" ssl="on" suborg="/org-RHEL/org-Fence/"/> </fencedevices>
<fencedevices>
<fencedevice agent="fence_cisco_ucs" ipaddr="192.168.0.1" login="root" name="ciscoucstest1" \
passwd="password123" power_wait="60" ssl="on" suborg="/org-RHEL/org-Fence/"/>
</fencedevices>
4.6. Dell Drac 5 Copy linkLink copied to clipboard!
fence_drac5
, the fence agent for Dell DRAC 5.
luci Field | cluster.conf Attribute | Description |
---|---|---|
Name | name | The name assigned to the DRAC. |
IP Address or Hostname | ipaddr | The IP address or host name assigned to the DRAC. |
IP Port (optional) | ipport | The TCP port to use to connect to the device. |
Login | login | The login name used to access the DRAC. |
Password | passwd | The password used to authenticate the connection to the DRAC. |
Password Script (optional) | passwd_script | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Use SSH | secure | Indicates that the system will use SSH to access the device. When using SSH, you must specify either a password, a password script, or an identity file. |
SSH Options | ssh_options | SSH options to use. The default value is -1 -c blowfish . |
Path to SSH Identity File | identity_file | The identity file for SSH. |
Module Name | module_name | (optional) The module name for the DRAC when you have multiple DRAC modules. |
Force Command Prompt | cmd_prompt | The command prompt to use. The default value is '\$'. |
Power Wait (seconds) | power_wait | Number of seconds to wait after issuing a power off or power on command. |
Delay (seconds) | delay | The number of seconds to wait before fencing is started. The default value is 0. |
Power Timeout (seconds) | power_timeout | Number of seconds to continue testing for a status change after issuing a power off or power on command. The default value is 20. |
Shell Timeout (seconds) | shell_timeout | Number of seconds to wait for a command prompt after issuing a command. The default value is 3. |
Login Timeout (seconds) | login_timeout | Number of seconds to wait for a command prompt after login. The default value is 5. |
Times to Retry Power On Operation | retry_on | Number of attempts to retry a power on operation. The default value is 1. |
Figure 4.6. Dell Drac 5
ccs -f cluster.conf --addfencedev delldrac5test1 agent=fence_drac5 ipaddr=192.168.0.1 login=root passwd=password123\ module_name=drac1 power_wait=60
ccs -f cluster.conf --addfencedev delldrac5test1 agent=fence_drac5 ipaddr=192.168.0.1 login=root passwd=password123\
module_name=drac1 power_wait=60
cluster.conf
entry for the fence_drac5
device:
<fencedevices> <fencedevice agent="fence_drac5" cmd_prompt="\$" ipaddr="192.168.0.1" login="root" module_name="drac1" \ name="delldrac5test1" passwd="password123" power_wait="60"/> </fencedevices>
<fencedevices>
<fencedevice agent="fence_drac5" cmd_prompt="\$" ipaddr="192.168.0.1" login="root" module_name="drac1" \
name="delldrac5test1" passwd="password123" power_wait="60"/>
</fencedevices>
4.7. Eaton Network Power Switch Copy linkLink copied to clipboard!
fence_eaton_snmp
, the fence agent for the Eaton over SNMP network power switch.
luci Field | cluster.conf Attribute | Description |
---|---|---|
Name | name | A name for the Eaton network power switch connected to the cluster. |
IP Address or Hostname | ipaddr | The IP address or host name assigned to the device. |
UDP/TCP Port (optional) | udpport | The UDP/TCP port to use for connection with the device; the default value is 161. |
Login | login | The login name used to access the device. |
Password | passwd | The password used to authenticate the connection to the device. |
Password Script (optional) | passwd_script | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
SNMP Version | snmp_version | The SNMP version to use (1, 2c, 3); the default value is 1. |
SNMP Community | community | The SNMP community string; the default value is private . |
SNMP Security Level | snmp_sec_level | The SNMP security level (noAuthNoPriv, authNoPriv, authPriv). |
SNMP Authentication Protocol | snmp_auth_prot | The SNMP authentication protocol (MD5, SHA). |
SNMP Privacy Protocol | snmp_priv_prot | The SNMP privacy protocol (DES, AES). |
SNMP Privacy Protocol Password | snmp_priv_passwd | The SNMP privacy protocol password. |
SNMP Privacy Protocol Script | snmp_priv_passwd_script | The script that supplies a password for SNMP privacy protocol. Using this supersedes the | parameter.
Power wait (seconds) | power_wait | Number of seconds to wait after issuing a power off or power on command. |
Power Timeout (seconds) | power_timeout | Number of seconds to continue testing for a status change after issuing a power off or power on command. The default value is 20. |
Shell Timeout (seconds) | shell_timeout | Number of seconds to wait for a command prompt after issuing a command. The default value is 3. |
Login Timeout (seconds) | login_timeout | Number of seconds to wait for a command prompt after login. The default value is 5. |
Times to Retry Power On Operation | retry_on | Number of attempts to retry a power on operation. The default value is 1. |
Port (Outlet) Number | port | Physical plug number or name of virtual machine. This parameter is always required. |
Delay (optional) | delay | The number of seconds to wait before fencing is started. The default value is 0. |
Figure 4.7. Eaton Network Power Switch
ccs -f cluster.conf --addfencedev eatontest agent=fence_eaton_snmp ipaddr=192.168.0.1 login=root \ passwd=password123 power_wait=60 snmp_priv_passwd=eatonpassword123 udpport=161
ccs -f cluster.conf --addfencedev eatontest agent=fence_eaton_snmp ipaddr=192.168.0.1 login=root \
passwd=password123 power_wait=60 snmp_priv_passwd=eatonpassword123 udpport=161
cluster.conf
entry for the fence_eaton_snmp
device:
4.8. Egenera BladeFrame Copy linkLink copied to clipboard!
fence_egenera
, the fence agent for the Egenera BladeFrame.
luci Field | cluster.conf Attribute | Description |
---|---|---|
Name | name | A name for the Egenera BladeFrame device connected to the cluster. |
CServer | cserver | The host name (and optionally the user name in the form of username@hostname ) assigned to the device. Refer to the fence_egenera(8) man page for more information. |
ESH Path (optional) | esh | The path to the esh command on the cserver (default is /opt/panmgr/bin/esh) |
Username | user | The login name. The default value is root . |
lpan | lpan | The logical process area network (LPAN) of the device. |
pserver | pserver | The processing blade (pserver) name of the device. |
Delay (optional) | delay | The number of seconds to wait before fencing is started. The default value is 0. |
Unfencing | unfence section of the cluster configuration file | When enabled, this ensures that a fenced node is not re-enabled until the node has been rebooted. This is necessary for non-power fence methods (that is, SAN/storage fencing). When you configure a device that requires unfencing, the cluster must first be stopped and the full configuration including devices and unfencing must be added before the cluster is started. For more information about unfencing a node, see the fence_node (8) man page. |
Figure 4.8. Egenera BladeFrame
ccs -f cluster.conf --addfencedev egeneratest agent=fence_egenera user=root cserver=cservertest
ccs -f cluster.conf --addfencedev egeneratest agent=fence_egenera user=root cserver=cservertest
cluster.conf
entry for the fence_egenera
device:
<fencedevices> <fencedevice agent="fence_egenera" cserver="cservertest" name="egeneratest" user="root"/> </fencedevices>
<fencedevices>
<fencedevice agent="fence_egenera" cserver="cservertest" name="egeneratest" user="root"/>
</fencedevices>
4.9. Emerson Network Power Switch (SNMP interface) Copy linkLink copied to clipboard!
fence_emerson
, the fence agent for Emerson over SNMP.
luci Field | cluster.conf Attribute | Description |
---|---|---|
Name | name | A name for the Emerson Network Power Switch device connected to the cluster. |
IP Address or Hostname | ipaddr | The IP address or host name assigned to the device. |
UDP/TCP Port (optional) | udpport | UDP/TCP port to use for connections with the device; the default value is 161. |
Login | login | The login name used to access the device. |
Password | passwd | The password used to authenticate the connection to the device. |
Password Script (optional) | passwd_script | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
SNMP Version | snmp_version | The SNMP version to use (1, 2c, 3); the default value is 1. |
SNMP Community | community | The SNMP community string. |
SNMP Security Level | snmp_sec_level | The SNMP security level (noAuthNoPriv, authNoPriv, authPriv). |
SNMP Authentication Protocol | snmp_auth_prot | The SNMP authentication protocol (MD5, SHA). |
SNMP Privacy Protocol | snmp_priv_prot | The SNMP privacy protocol (DES, AES). |
SNMP privacy protocol password | snmp_priv_passwd | The SNMP Privacy Protocol Password. |
SNMP Privacy Protocol Script | snmp_priv_passwd_script | The script that supplies a password for SNMP privacy protocol. Using this supersedes the | parameter.
Power Wait (seconds) | power_wait | Number of seconds to wait after issuing a power off or power on command. |
Power Timeout (seconds) | power_timeout | Number of seconds to continue testing for a status change after issuing a power off or power on command. The default value is 20. |
Shell Timeout (seconds) | shell_timeout | Number of seconds to wait for a command prompt after issuing a command. The default value is 3. |
Login Timeout (seconds) | login_timeout | Number of seconds to wait for a command prompt after login. The default value is 5. |
Times to Retry Power On Operation | retry_on | Number of attempts to retry a power on operation. The default value is 1. |
Port (Outlet) Number | port | Physical plug number or name of virtual machine. |
Delay (optional) | delay | The number of seconds to wait before fencing is started. The default value is 0. |
4.10. ePowerSwitch Copy linkLink copied to clipboard!
fence_eps
, the fence agent for ePowerSwitch.
luci Field | cluster.conf Attribute | Description |
---|---|---|
Name | name | A name for the ePowerSwitch device connected to the cluster. |
IP Address or Hostname | ipaddr | The IP address or host name assigned to the device. |
Login | login | The login name used to access the device. |
Password | passwd | The password used to authenticate the connection to the device. |
Password Script (optional) | passwd_script | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Name of Hidden Page | hidden_page | The name of the hidden page for the device. |
Times to Retry Power On Operation | retry_on | Number of attempts to retry a power on operation. The default value is 1. |
Port (Outlet) Number | port | Physical plug number or name of virtual machine. |
Delay (optional) | delay | The number of seconds to wait before fencing is started. The default value is 0. |
Figure 4.9. ePowerSwitch
ccs -f cluster.conf --addfencedev epstest1 agent=fence_eps ipaddr=192.168.0.1 login=root passwd=password123 \ hidden_page=hidden.htm
ccs -f cluster.conf --addfencedev epstest1 agent=fence_eps ipaddr=192.168.0.1 login=root passwd=password123 \
hidden_page=hidden.htm
cluster.conf
entry for the fence_eps
device:
<fencedevices> <fencedevice agent="fence_eps" hidden_page="hidden.htm" ipaddr="192.168.0.1" login="root" name="epstest1" \ passwd="password123"/> </fencedevices>
<fencedevices>
<fencedevice agent="fence_eps" hidden_page="hidden.htm" ipaddr="192.168.0.1" login="root" name="epstest1" \
passwd="password123"/>
</fencedevices>
4.11. Fence Virt (Serial/VMChannel Mode) Copy linkLink copied to clipboard!
fence_virt
, the fence agent for virtual machines using VM channel or serial mode .
luci Field | cluster.conf Attribute | Description |
---|---|---|
Name | name | A name for the Fence virt fence device. |
Serial Device | serial_device | On the host, the serial device must be mapped in each domain's configuration file. For more information, see the fence_virt man page. If this field is specified, it causes the fence_virt fencing agent to operate in serial mode. Not specifying a value causes the fence_virt fencing agent to operate in VM channel mode. |
Serial Parameters | serial_params | The serial parameters. The default is 115200, 8N1. |
VM Channel IP Address | channel_address | The channel IP. The default value is 10.0.2.179. |
Timeout (optional) | timeout | Fencing timeout, in seconds. The default value is 30. |
Domain | port (formerly domain ) | Virtual machine (domain UUID or name) to fence. |
ipport | The channel port. The default value is 1229, which is the value used when configuring this fence device with luci. | |
Delay (optional) | delay | Fencing delay, in seconds. The fence agent will wait the specified number of seconds before attempting a fencing operation. The default value is 0. |
ccs -f cluster.conf --addfencedev fencevirt1 agent=fence_virt serial_device=/dev/ttyS1 serial_params=19200, 8N1
ccs -f cluster.conf --addfencedev fencevirt1 agent=fence_virt serial_device=/dev/ttyS1 serial_params=19200, 8N1
cluster.conf
entry for the fence_virt
device:
<fencedevices> <fencedevice agent="fence_virt" name="fencevirt1" serial_device="/dev/ttyS1" serial_params="19200, 8N1"/> </fencedevices>
<fencedevices>
<fencedevice agent="fence_virt" name="fencevirt1" serial_device="/dev/ttyS1" serial_params="19200, 8N1"/>
</fencedevices>
4.12. Fence Virt (Multicast Mode) Copy linkLink copied to clipboard!
fence_xvm
, the fence agent for virtual machines using multicast.
luci Field | cluster.conf Attribute | Description |
---|---|---|
Name | name | A name for the Fence virt fence device. |
Timeout | timeout | Fencing timeout, in seconds. The default value is 30. |
Domain | port (formerly domain ) | Virtual machine (domain UUID or name) to fence. |
Delay (optional) | delay | Fencing delay, in seconds. The fence agent will wait the specified number of seconds before attempting a fencing operation. The default value is 0. |
4.13. Fujitsu-Siemens RemoteView Service Board (RSB) Copy linkLink copied to clipboard!
fence_rsb
, the fence agent for Fujitsu-Siemens RemoteView Service Board (RSB).
luci Field | cluster.conf Attribute | Description |
---|---|---|
Name | name | A name for the RSB to use as a fence device. |
IP Address or Hostname | ipaddr | The host name assigned to the device. |
Login | login | The login name used to access the device. |
Password | passwd | The password used to authenticate the connection to the device. |
Password Script (optional) | passwd_script | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
TCP Port | ipport | The port number on which the telnet service listens. The default value is 3172. |
Force Command Prompt | cmd_prompt | The command prompt to use. The default value is '\$'. |
Power Wait (seconds) | power_wait | Number of seconds to wait after issuing a power off or power on command. |
Delay (seconds) | delay | The number of seconds to wait before fencing is started. The default value is 0. |
Power Timeout (seconds) | power_timeout | Number of seconds to continue testing for a status change after issuing a power off or power on command. The default value is 20. |
Shell Timeout (seconds) | shell_timeout | Number of seconds to wait for a command prompt after issuing a command. The default value is 3. |
Login Timeout (seconds) | login_timeout | Number of seconds to wait for a command prompt after login. The default value is 5. |
Times to Retry Power On Operation | retry_on | Number of attempts to retry a power on operation. The default value is 1. |
Figure 4.10. Fujitsu-Siemens RSB
ccs -f cluster.conf --addfencedev fsrbtest1 agent=fence_rsb ipaddr=192.168.0.1 login=root passwd=password123 \ telnet_port=3172
ccs -f cluster.conf --addfencedev fsrbtest1 agent=fence_rsb ipaddr=192.168.0.1 login=root passwd=password123 \
telnet_port=3172
cluster.conf
entry for the fence_rsb
device:
<fencedevices> <fencedevice agent="fence_rsb" ipaddr="192.168.0.1" login="root" name="fsrsbtest1" passwd="password123" telnet_port="3172"/> </fencedevices>
<fencedevices>
<fencedevice agent="fence_rsb" ipaddr="192.168.0.1" login="root" name="fsrsbtest1" passwd="password123" telnet_port="3172"/>
</fencedevices>
4.14. Hewlett-Packard BladeSystem Copy linkLink copied to clipboard!
fence_hpblade
, the fence agent for HP BladeSystem.
luci Field | cluster.conf Attribute | Description |
---|---|---|
Name | name | The name assigned to the HP Bladesystem device connected to the cluster. |
IP Address or Hostname | ipaddr | The IP address or host name assigned to the HP BladeSystem device. |
IP Port (optional) | ipport | The TCP port to use to connect to the device. |
Login | login | The login name used to access the HP BladeSystem device. This parameter is required. |
Password | passwd | The password used to authenticate the connection to the fence device. |
Password Script (optional) | passwd_script | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Force Command Prompt | cmd_prompt | The command prompt to use. The default value is '\$'. |
Missing port returns OFF instead of failure | missing_as_off | Missing port returns OFF instead of failure. |
Power Wait (seconds) | power_wait | Number of seconds to wait after issuing a power off or power on command. |
Power Timeout (seconds) | power_timeout | Number of seconds to continue testing for a status change after issuing a power off or power on command. The default value is 20. |
Shell Timeout (seconds) | shell_timeout | Number of seconds to wait for a command prompt after issuing a command. The default value is 3. |
Login Timeout (seconds) | login_timeout | Number of seconds to wait for a command prompt after login. The default value is 5. |
Times to Retry Power On Operation | retry_on | Number of attempts to retry a power on operation. The default value is 1. |
Use SSH | secure | Indicates that the system will use SSH to access the device. When using SSH, you must specify either a password, a password script, or an identity file. |
SSH Options | ssh_options | SSH options to use. The default value is -1 -c blowfish . |
Path to SSH Identity File | identity_file | The identity file for SSH. |
Figure 4.11. HP BladeSystem
ccs -f cluster.conf --addfencedev hpbladetest1 agent=fence_hpblade cmd_prompt=c7000oa> ipaddr=192.168.0.1 \ login=root passwd=password123 missing_as_off=on power_wait=60
ccs -f cluster.conf --addfencedev hpbladetest1 agent=fence_hpblade cmd_prompt=c7000oa> ipaddr=192.168.0.1 \
login=root passwd=password123 missing_as_off=on power_wait=60
cluster.conf
entry for the fence_hpblade
device:
4.15. Hewlett-Packard iLO Copy linkLink copied to clipboard!
fence_ilo
and HP iLO2 devices fence_ilo2
. share the same implementation. Table 4.16, “HP iLO (Integrated Lights Out) and HP iLO2” lists the fence device parameters used by these agents.
luci Field | cluster.conf Attribute | Description |
---|---|---|
Name | name | A name for the server with HP iLO support. |
IP Address or Hostname | ipaddr | The IP address or host name assigned to the device. |
IP Port (optional) | ipport | TCP port to use for connection with the device. The default value is 443. |
Login | login | The login name used to access the device. |
Password | passwd | The password used to authenticate the connection to the device. |
Password Script (optional) | passwd_script | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Power Wait (seconds) | power_wait | Number of seconds to wait after issuing a power off or power on command. |
Delay (seconds) | delay | The number of seconds to wait before fencing is started. The default value is 0. |
Power Timeout (seconds) | power_timeout | Number of seconds to continue testing for a status change after issuing a power off or power on command. The default value is 20. |
Shell Timeout (seconds) | shell_timeout | Number of seconds to wait for a command prompt after issuing a command. The default value is 3. |
Login Timeout (seconds) | login_timeout | Number of seconds to wait for a command prompt after login. The default value is 5. |
Times to Retry Power On Operation | retry_on | Number of attempts to retry a power on operation. The default value is 1. |
Figure 4.12. HP iLO
ccs -f cluster.conf --addfencedev hpilotest1 agent=fence_hpilo ipaddr=192.168.0.1 login=root passwd=password123 \ power_wait=60
ccs -f cluster.conf --addfencedev hpilotest1 agent=fence_hpilo ipaddr=192.168.0.1 login=root passwd=password123 \
power_wait=60
cluster.conf
entry for the fence_ilo
device:
<fencedevices> <fencedevice agent="fence_ilo" ipaddr="192.168.0.1" login="root" name="hpilotest1" passwd="password123" \ power_wait="60"/> </fencedevices>
<fencedevices>
<fencedevice agent="fence_ilo" ipaddr="192.168.0.1" login="root" name="hpilotest1" passwd="password123" \
power_wait="60"/>
</fencedevices>
4.16. HP iLO over SSH Copy linkLink copied to clipboard!
fence_ilo_ssh
), HP iLO3 devices over SSH (fence_ilo3_ssh
), and HP iLO4 devices over SSH (fence_ilo4_ssh
) share the same implementation. Table 4.17, “HP iLO over SSH, HP iLO3 over SSH, HPiLO4 over SSH (Red Hat Enterprise Linux 6.7 and later)” lists the fence device parameters used by these agents.
luci Field | cluster.conf Attribute | Description |
---|---|---|
Name | name | A name for the server with HP iLO support. |
IP Address or Hostname | ipaddr | The IP address or host name assigned to the device. |
Login | login | The login name used to access the device. |
Password | passwd | The password used to authenticate the connection to the device. |
Password Script (optional) | passwd_script | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Use SSH | secure | Indicates that the system will use SSH to access the device. When using SSH, you must specify either a password, a password script, or an identity file. |
Path to SSH Identity File | identity_file | The Identity file for SSH. |
TCP Port | ipport | UDP/TCP port to use for connections with the device; the default value is 23. |
Force Command Prompt | cmd_prompt | The command prompt to use. The default value is 'MP>', 'hpiLO->'. |
Method to Fence | method | The method to fence: on/off or cycle |
Power Wait (seconds) | power_wait | Number of seconds to wait after issuing a power off or power on command. |
Delay (seconds) | delay | The number of seconds to wait before fencing is started. The default value is 0. |
Power Timeout (seconds) | power_timeout | Number of seconds to continue testing for a status change after issuing a power off or power on command. The default value is 20. |
Shell Timeout (seconds) | shell_timeout | Number of seconds to wait for a command prompt after issuing a command. The default value is 3. |
Login Timeout (seconds) | login_timeout | Number of seconds to wait for a command prompt after login. The default value is 5. |
Times to Retry Power On Operation | retry_on | Number of attempts to retry a power on operation. The default value is 1. |
4.17. Hewlett-Packard iLO MP Copy linkLink copied to clipboard!
fence_ilo_mp
, the fence agent for HP iLO MP devices.
luci Field | cluster.conf Attribute | Description |
---|---|---|
Name | name | A name for the server with HP iLO support. |
IP Address or Hostname | ipaddr | The IP address or host name assigned to the device. |
IP Port (optional) | ipport | TCP port to use for connection with the device. |
Login | login | The login name used to access the device. |
Password | passwd | The password used to authenticate the connection to the device. |
Password Script (optional) | passwd_script | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Use SSH | secure | Indicates that the system will use SSH to access the device. When using SSH, you must specify either a password, a password script, or an identity file. |
SSH Options | ssh_options | SSH options to use. The default value is -1 -c blowfish . |
Path to SSH Identity File | identity_file | The Identity file for SSH. |
Force Command Prompt | cmd_prompt | The command prompt to use. The default value is 'MP>', 'hpiLO->'. |
Power Wait (seconds) | power_wait | Number of seconds to wait after issuing a power off or power on command. |
Delay (seconds) | delay | The number of seconds to wait before fencing is started. The default value is 0. |
Power Timeout (seconds) | power_timeout | Number of seconds to continue testing for a status change after issuing a power off or power on command. The default value is 20. |
Shell Timeout (seconds) | shell_timeout | Number of seconds to wait for a command prompt after issuing a command. The default value is 3. |
Login Timeout (seconds) | login_timeout | Number of seconds to wait for a command prompt after login. The default value is 5. |
Times to Retry Power On Operation | retry_on | Number of attempts to retry a power on operation. The default value is 1. |
Figure 4.13. HP iLO MP
ccs -f cluster.conf --addfencedev hpilomptest1 agent=fence_hpilo cmd_prompt=hpiLO-> ipaddr=192.168.0.1 \ login=root passwd=password123 power_wait=60
ccs -f cluster.conf --addfencedev hpilomptest1 agent=fence_hpilo cmd_prompt=hpiLO-> ipaddr=192.168.0.1 \
login=root passwd=password123 power_wait=60
cluster.conf
entry for the fence_hpilo_mp
device:
<fencedevices> <fencedevice agent="fence_ilo_mp" cmd_prompt="hpiLO->" ipaddr="192.168.0.1" login="root" name="hpilomptest1" passwd="password123" power_wait="60"/> </fencedevices>
<fencedevices>
<fencedevice agent="fence_ilo_mp" cmd_prompt="hpiLO->" ipaddr="192.168.0.1" login="root" name="hpilomptest1" passwd="password123" power_wait="60"/>
</fencedevices>
4.18. HP Moonshot iLO Copy linkLink copied to clipboard!
fence_ilo_moonshot
, the fence agent for HP Moonshot iLO devices.
luci Field | cluster.conf Attribute | Description |
---|---|---|
Name | name | A name for the server with HP iLO support. |
IP Address or Hostname | ipaddr | The IP address or host name assigned to the device. |
Login | login | The login name used to access the device. |
Password | passwd | The password used to authenticate the connection to the device. |
Password Script (optional) | passwd_script | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Use SSH | secure | Indicates that the system will use SSH to access the device. When using SSH, you must specify either a password, a password script, or an identity file. |
Path to SSH Identity File | identity_file | The Identity file for SSH. |
TCP Port | ipport | UDP/TCP port to use for connections with the device; the default value is 22. |
Force Command Prompt | cmd_prompt | The command prompt to use. The default value is 'MP>', 'hpiLO->'. |
Power Wait (seconds) | power_wait | Number of seconds to wait after issuing a power off or power on command. |
Delay (seconds) | delay | The number of seconds to wait before fencing is started. The default value is 0. |
Power Timeout (seconds) | power_timeout | Number of seconds to continue testing for a status change after issuing a power off or power on command. The default value is 20. |
Shell Timeout (seconds) | shell_timeout | Number of seconds to wait for a command prompt after issuing a command. The default value is 3. |
Login Timeout (seconds) | login_timeout | Number of seconds to wait for a command prompt after login. The default value is 5. |
Times to Retry Power On Operation | retry_on | Number of attempts to retry a power on operation. The default value is 1. |
4.19. IBM BladeCenter Copy linkLink copied to clipboard!
fence_bladecenter
, the fence agent for IBM BladeCenter.
luci Field | cluster.conf Attribute | Description |
---|---|---|
Name | name | A name for the IBM BladeCenter device connected to the cluster. |
IP Address or Hostname | ipaddr | The IP address or host name assigned to the device. |
IP port (optional) | ipport | TCP port to use for connection with the device. |
Login | login | The login name used to access the device. |
Password | passwd | The password used to authenticate the connection to the device. |
Password Script (optional) | passwd_script | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Power Wait (seconds) | power_wait | Number of seconds to wait after issuing a power off or power on command. |
Power Timeout (seconds) | power_timeout | Number of seconds to continue testing for a status change after issuing a power off or power on command. The default value is 20. |
Shell Timeout (seconds) | shell_timeout | Number of seconds to wait for a command prompt after issuing a command. The default value is 3. |
Login Timeout (seconds) | login_timeout | Number of seconds to wait for a command prompt after login. The default value is 5. |
Times to Retry Power On Operation | retry_on | Number of attempts to retry a power on operation. The default value is 1. |
Use SSH | secure | Indicates that system will use SSH to access the device. When using SSH, you must specify either a password, a password script, or an identity file. |
SSH Options | ssh_options | SSH options to use. The default value is -1 -c blowfish . |
Path to SSH Identity File | identity_file | The identity file for SSH. |
Figure 4.14. IBM BladeCenter
ccs -f cluster.conf --addfencedev bladecentertest1 agent=fence_bladecenter ipaddr=192.168.0.1 login=root \ passwd=password123 power_wait=60
ccs -f cluster.conf --addfencedev bladecentertest1 agent=fence_bladecenter ipaddr=192.168.0.1 login=root \
passwd=password123 power_wait=60
cluster.conf
entry for the fence_bladecenter
device:
<fencedevices> <fencedevice agent="fence_bladecenter" ipaddr="192.168.0.1" login="root" name="bladecentertest1" passwd="password123" \ power_wait="60"/> </fencedevices>
<fencedevices>
<fencedevice agent="fence_bladecenter" ipaddr="192.168.0.1" login="root" name="bladecentertest1" passwd="password123" \
power_wait="60"/>
</fencedevices>
4.20. IBM BladeCenter over SNMP Copy linkLink copied to clipboard!
fence_ibmblade
, the fence agent for IBM BladeCenter over SNMP.
luci Field | cluster.conf Attribute | Description |
---|---|---|
Name | name | A name for the IBM BladeCenter SNMP device connected to the cluster. |
IP Address or Hostname | ipaddr | The IP address or host name assigned to the device. |
UDP/TCP Port (optional) | udpport | UDP/TCP port to use for connections with the device; the default value is 161. |
Login | login | The login name used to access the device. |
Password | passwd | The password used to authenticate the connection to the device. |
Password Script (optional) | passwd_script | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
SNMP Version | snmp_version | The SNMP version to use (1, 2c, 3); the default value is 1. |
SNMP Community | community | The SNMP community string. |
SNMP Security Level | snmp_sec_level | The SNMP security level (noAuthNoPriv, authNoPriv, authPriv). |
SNMP Authentication Protocol | snmp_auth_prot | The SNMP authentication protocol (MD5, SHA). |
SNMP Privacy Protocol | snmp_priv_prot | The SNMP privacy protocol (DES, AES). |
SNMP privacy protocol password | snmp_priv_passwd | The SNMP Privacy Protocol Password. |
SNMP Privacy Protocol Script | snmp_priv_passwd_script | The script that supplies a password for SNMP privacy protocol. Using this supersedes the | parameter.
Power Wait (seconds) | power_wait | Number of seconds to wait after issuing a power off or power on command. |
Power Timeout (seconds) | power_timeout | Number of seconds to continue testing for a status change after issuing a power off or power on command. The default value is 20. |
Shell Timeout (seconds) | shell_timeout | Number of seconds to wait for a command prompt after issuing a command. The default value is 3. |
Login Timeout (seconds) | login_timeout | Number of seconds to wait for a command prompt after login. The default value is 5. |
Times to Retry Power On Operation | retry_on | Number of attempts to retry a power on operation. The default value is 1. |
Port (Outlet) Number | port | Physical plug number or name of virtual machine. |
Delay (optional) | delay | The number of seconds to wait before fencing is started. The default value is 0. |
Figure 4.15. IBM BladeCenter SNMP
ccs -f cluster.conf --addfencedev bladesnmp1 agent=fence_ibmblade community=private ipaddr=192.168.0.1 login=root \ passwd=password123 snmp_priv_passwd=snmpasswd123 power_wait=60
ccs -f cluster.conf --addfencedev bladesnmp1 agent=fence_ibmblade community=private ipaddr=192.168.0.1 login=root \
passwd=password123 snmp_priv_passwd=snmpasswd123 power_wait=60
cluster.conf
entry for the fence_ibmblade
device:
<fencedevices> <fencedevice agent="fence_ibmblade" community="private" ipaddr="192.168.0.1" login="root" name="bladesnmp1" \ passwd="password123" power_wait="60" snmp_priv_passwd="snmpasswd123" udpport="161"/> </fencedevices>
<fencedevices>
<fencedevice agent="fence_ibmblade" community="private" ipaddr="192.168.0.1" login="root" name="bladesnmp1" \
passwd="password123" power_wait="60" snmp_priv_passwd="snmpasswd123" udpport="161"/>
</fencedevices>
4.21. IBM iPDU Copy linkLink copied to clipboard!
fence_ipdu
, the fence agent for iPDU over SNMP devices.
luci Field | cluster.conf Attribute | Description |
---|---|---|
Name | name | A name for the IBM iPDU device connected to the cluster into which the fence daemon logs by means of the SNMP protocol. |
IP Address or Hostname | ipaddr | The IP address or host name assigned to the device. |
UDP/TCP Port | udpport | The UDP/TCP port to use for connection with the device; the default value is 161. |
Login | login | The login name used to access the device. |
Password | passwd | The password used to authenticate the connection to the device. |
Password Script (optional) | passwd_script | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
SNMP Version | snmp_version | The SNMP version to use (1, 2c, 3); the default value is 1. |
SNMP Community | community | The SNMP community string; the default value is private . |
SNMP Security Level | snmp_sec_level | The SNMP security level (noAuthNoPriv, authNoPriv, authPriv). |
SNMP Authentication Protocol | snmp_auth_prot | The SNMP Authentication Protocol (MD5, SHA). |
SNMP Privacy Protocol | snmp_priv_prot | The SNMP privacy protocol (DES, AES). |
SNMP Privacy Protocol Password | snmp_priv_passwd | The SNMP privacy protocol password. |
SNMP Privacy Protocol Script | snmp_priv_passwd_script | The script that supplies a password for SNMP privacy protocol. Using this supersedes the | parameter.
Power Wait (seconds) | power_wait | Number of seconds to wait after issuing a power off or power on command. |
Power Timeout (seconds) | power_timeout | Number of seconds to continue testing for a status change after issuing a power off or power on command. The default value is 20. |
Shell Timeout (seconds) | shell_timeout | Number of seconds to wait for a command prompt after issuing a command. The default value is 3. |
Login Timeout (seconds) | login_timeout | Number of seconds to wait for a command prompt after login. The default value is 5. |
Times to Retry Power On Operation | retry_on | Number of attempts to retry a power on operation. The default value is 1. |
Port (Outlet) Number | port | Physical plug number or name of virtual machine. |
Delay (optional) | delay | The number of seconds to wait before fencing is started. The default value is 0. |
Figure 4.16. IBM iPDU
ccs -f cluster.conf --addfencedev ipdutest1 agent=fence_ipdu community=ipdusnmpcom ipaddr=192.168.0.1 login=root \ passwd=password123 snmp_priv_passwd=snmpasswd123 power_wait=60 snmp_priv_prot=AES udpport=111
ccs -f cluster.conf --addfencedev ipdutest1 agent=fence_ipdu community=ipdusnmpcom ipaddr=192.168.0.1 login=root \
passwd=password123 snmp_priv_passwd=snmpasswd123 power_wait=60 snmp_priv_prot=AES udpport=111
cluster.conf
entry for the fence_ipdu
device:
4.22. IF-MIB Copy linkLink copied to clipboard!
fence_ifmib
, the fence agent for IF-MIB devices.
luci Field | cluster.conf Attribute | Description |
---|---|---|
Name | name | A name for the IF MIB device connected to the cluster. |
IP Address or Hostname | ipaddr | The IP address or host name assigned to the device. |
UDP/TCP Port (optional) | udpport | The UDP/TCP port to use for connection with the device; the default value is 161. |
Login | login | The login name used to access the device. |
Password | passwd | The password used to authenticate the connection to the device. |
Password Script (optional) | passwd_script | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
SNMP Version | snmp_version | The SNMP version to use (1, 2c, 3); the default value is 1. |
SNMP Community | community | The SNMP community string. |
SNMP Security Level | snmp_sec_level | The SNMP security level (noAuthNoPriv, authNoPriv, authPriv). |
SNMP Authentication Protocol | snmp_auth_prot | The SNMP authentication protocol (MD5, SHA). |
SNMP Privacy Protocol | snmp_priv_prot | The SNMP privacy protocol (DES, AES). |
SNMP Privacy Protocol Password | snmp_priv_passwd | The SNMP privacy protocol password. |
SNMP Privacy Protocol Script | snmp_priv_passwd_script | The script that supplies a password for SNMP privacy protocol. Using this supersedes the | parameter.
Power Wait (seconds) | power_wait | Number of seconds to wait after issuing a power off or power on command. |
Power Timeout (seconds) | power_timeout | Number of seconds to continue testing for a status change after issuing a power off or power on command. The default value is 20. |
Shell Timeout (seconds) | shell_timeout | Number of seconds to wait for a command prompt after issuing a command. The default value is 3. |
Login Timeout (seconds) | login_timeout | Number of seconds to wait for a command prompt after login. The default value is 5. |
Times to Retry Power On Operation | retry_on | Number of attempts to retry a power on operation. The default value is 1. |
Port (Outlet) Number | port | Physical plug number or name of virtual machine. |
Delay (optional) | delay | The number of seconds to wait before fencing is started. The default value is 0. |
Figure 4.17. IF-MIB
ccs -f cluster.conf --addfencedev ifmib1 agent=fence_ifmib community=private ipaddr=192.168.0.1 login=root \ passwd=password123 snmp_priv_passwd=snmpasswd123 power_wait=60 udpport=161
ccs -f cluster.conf --addfencedev ifmib1 agent=fence_ifmib community=private ipaddr=192.168.0.1 login=root \
passwd=password123 snmp_priv_passwd=snmpasswd123 power_wait=60 udpport=161
cluster.conf
entry for the fence_ifmib
device:
<fencedevices> <fencedevice agent="fence_ifmib" community="private" ipaddr="192.168.0.1" login="root" name="ifmib1" \ passwd="password123" power_wait="60" snmp_priv_passwd="snmpasswd123" udpport="161"/> </fencedevices>
<fencedevices>
<fencedevice agent="fence_ifmib" community="private" ipaddr="192.168.0.1" login="root" name="ifmib1" \
passwd="password123" power_wait="60" snmp_priv_passwd="snmpasswd123" udpport="161"/>
</fencedevices>
4.23. Intel Modular Copy linkLink copied to clipboard!
fence_intelmodular
, the fence agent for Intel Modular.
luci Field | cluster.conf Attribute | Description |
---|---|---|
Name | name | A name for the Intel Modular device connected to the cluster. |
IP Address or Hostname | ipaddr | The IP address or host name assigned to the device. |
UDP/TCP Port (optional) | udpport | The UDP/TCP port to use for connection with the device; the default value is 161. |
Login | login | The login name used to access the device. |
Password | passwd | The password used to authenticate the connection to the device. |
Password Script (optional) | passwd_script | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
SNMP Version | snmp_version | The SNMP version to use (1, 2c, 3); the default value is 1. |
SNMP Community | community | The SNMP community string; the default value is private . |
SNMP Security Level | snmp_sec_level | The SNMP security level (noAuthNoPriv, authNoPriv, authPriv). |
SNMP Authentication Protocol | snmp_auth_prot | The SNMP authentication protocol (MD5, SHA). |
SNMP Privacy Protocol | snmp_priv_prot | The SNMP privacy protocol (DES, AES). |
SNMP Privacy Protocol Password | snmp_priv_passwd | The SNMP privacy protocol password. |
SNMP Privacy Protocol Script | snmp_priv_passwd_script | The script that supplies a password for SNMP privacy protocol. Using this supersedes the | parameter.
Power Wait (seconds) | power_wait | Number of seconds to wait after issuing a power off or power on command. |
Power Timeout (seconds) | power_timeout | Number of seconds to continue testing for a status change after issuing a power off or power on command. The default value is 20. |
Shell Timeout (seconds) | shell_timeout | Number of seconds to wait for a command prompt after issuing a command. The default value is 3. |
Login Timeout (seconds) | login_timeout | Number of seconds to wait for a command prompt after login. The default value is 5. |
Times to Retry Power On Operation | retry_on | Number of attempts to retry a power on operation. The default value is 1. |
Port (Outlet) Number | port | Physical plug number or name of virtual machine. |
Delay (optional) | delay | The number of seconds to wait before fencing is started. The default value is 0. |
Figure 4.18. Intel Modular
ccs -f cluster.conf --addfencedev intelmodular1 agent=fence_intelmodular community=private ipaddr=192.168.0.1 login=root \ passwd=password123 snmp_priv_passwd=snmpasswd123 power_wait=60 udpport=161
ccs -f cluster.conf --addfencedev intelmodular1 agent=fence_intelmodular community=private ipaddr=192.168.0.1 login=root \
passwd=password123 snmp_priv_passwd=snmpasswd123 power_wait=60 udpport=161
cluster.conf
entry for the fence_intelmodular
device:
<fencedevices> <fencedevice agent="fence_intelmodular" community="private" ipaddr="192.168.0.1" login="root" name="intelmodular1" \ passwd="password123" power_wait="60" snmp_priv_passwd="snmpasswd123" udpport="161"/> </fencedevices>
<fencedevices>
<fencedevice agent="fence_intelmodular" community="private" ipaddr="192.168.0.1" login="root" name="intelmodular1" \
passwd="password123" power_wait="60" snmp_priv_passwd="snmpasswd123" udpport="161"/>
</fencedevices>
4.24. IPMI over LAN Copy linkLink copied to clipboard!
fence_ipmilan
,) Dell iDRAC (fence_idrac
), IBM Integrated Management Module (fence_imm
), HP iLO3 devices (fence_ilo3
), and HP iLO4 devices (fence_ilo4
) share the same implementation. Table 4.25, “IPMI (Intelligent Platform Management Interface) LAN, Dell iDrac, IBM Integrated Management Module, HPiLO3, HPiLO4” lists the fence device parameters used by these agents.
luci Field | cluster.conf Attribute | Description |
---|---|---|
Name | name | A name for the fence device connected to the cluster. |
IP Address or Hostname | ipaddr | The IP address or host name assigned to the device. |
Login | login | The login name of a user capable of issuing power on/off commands to the given port. |
Password | passwd | The password used to authenticate the connection to the port. |
Password Script (optional) | passwd_script | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Authentication Type | auth | Authentication type: none , password , or MD5 . |
Use Lanplus | lanplus | True or 1 . If blank, then value is False . It is recommended that you enable Lanplus to improve the security of your connection if your hardware supports it. |
Ciphersuite to use | cipher | The remote server authentication, integrity, and encryption algorithms to use for IPMIv2 lanplus connections. |
Privilege level | privlvl | The privilege level on the device. |
IPMI Operation Timeout | timeout | Timeout in seconds for IPMI operation. |
Power Timeout (seconds) | power_timeout | Number of seconds to continue testing for a status change after issuing a power off or power on command. The default value is 20. |
Shell Timeout (seconds) | shell_timeout | Number of seconds to wait for a command prompt after issuing a command. The default value is 3. |
Login Timeout (seconds) | login_timeout | Number of seconds to wait for a command prompt after login. The default value is 5. |
Times to Retry Power On Operation | retry_on | Number of attempts to retry a power on operation. The default value is 1. |
Power Wait (seconds) | power_wait | Number of seconds to wait after issuing a power off or power on command. The default value is 2 seconds for fence_ipmilan , fence_idrac , fence_imm , and fence_ilo4 . The default value is 4 seconds for fence_ilo3 . |
Delay (optional) | delay | The number of seconds to wait before fencing is started. The default value is 0. |
Method to Fence | method | The method to fence: on/off or cycle |
Figure 4.19. IPMI over LAN
ccs -f cluster.conf --addfencedev ipmitest1 agent=fence_ipmilan auth=password cipher=3 ipaddr=192.168.0.1 \ lanplus=on login=root passwd=password123
ccs -f cluster.conf --addfencedev ipmitest1 agent=fence_ipmilan auth=password cipher=3 ipaddr=192.168.0.1 \
lanplus=on login=root passwd=password123
cluster.conf
entry for the fence_ipmilan
device:
<fencedevices> <fencedevice agent="fence_ipmilan" auth="password" cipher="3" ipaddr="192.168.0.1" lanplus="on" login="root" \ name="ipmitest1" passwd="password123"/> </fencedevices>
<fencedevices>
<fencedevice agent="fence_ipmilan" auth="password" cipher="3" ipaddr="192.168.0.1" lanplus="on" login="root" \
name="ipmitest1" passwd="password123"/>
</fencedevices>
4.25. Fence kdump Copy linkLink copied to clipboard!
fence_dkump
, the fence agent for kdump
crash recovery service. Note that fence_kdump
is not a replacement for traditional fencing methods; The fence_kdump
agent can detect only that a node has entered the kdump
crash recovery service. This allows the kdump
crash recovery service to complete without being preempted by traditional power fencing methods.
luci Field | cluster.conf Attribute | Description |
---|---|---|
Name | name | A name for the fence_kdump device. |
IP Family | family | IP network family. The default value is auto . |
IP Port (optional) | ipport | IP port number that the fence_kdump agent will use to listen for messages. The default value is 7410. |
Operation Timeout (seconds) (optional) | timeout | Number of seconds to wait for message from failed node. |
Node name | nodename | Name or IP address of the node to be fenced. |
4.26. Multipath Persistent Reservation Fencing (Red Hat Enterprise Linux 6.7 and later) Copy linkLink copied to clipboard!
fence_mpath
, the fence agent for multipath persistent reservation fencing.
luci Field | cluster.conf Attribute | Description |
---|---|---|
Name | name | A name for the fence_mpath device. |
Devices (Comma delimited list) | devices | Comma-separated list of devices to use for the current operation. Each device must support SCSI-3 persistent reservations. |
Use sudo when calling third-party software | sudo | Use sudo (without password) when calling 3rd party software. |
Path to sudo binary (optional) | sudo_path | Path to sudo binary (default value is /usr/bin/sudo . |
Path to mpathpersist binary (optional) | mpathpersist_path | Path to mpathpersist binary (default value is /sbin/mpathpersist . |
Path to a directory where the fence agent can store information (optional) | store_path | Path to directory where fence agent can store information (default value is /var/run/cluster . |
Power Wait (seconds) | power_wait | Number of seconds to wait after issuing a power off or power on command. |
Power Timeout (seconds) | power_timeout | Number of seconds to continue testing for a status change after issuing a power off or power on command. The default value is 20. |
Shell Timeout (seconds) | shell_timeout | Number of seconds to wait for a command prompt after issuing a command. The default value is 3. |
Login Timeout (seconds) | login_timeout | Number of seconds to wait for a command prompt after login. The default value is 5. |
Times to Retry Power On Operation | retry_on | Number of attempts to retry a power on operation. The default value is 1. |
Unfencing | unfence section of the cluster configuration file | When enabled, this ensures that a fenced node is not re-enabled until the node has been rebooted. This is necessary for non-power fence methods. When you configure a device that requires unfencing, the cluster must first be stopped and the full configuration including devices and unfencing must be added before the cluster is started. For more information about unfencing a node, see the fence_node (8) man page. |
Key for current action | key | Key to use for the current operation. This key should be unique to a node and written in /etc/multipath.conf . For the "on" action, the key specifies the key use to register the local node. For the "off" action, this key specifies the key to be removed from the device(s). This parameter is always required. |
Delay (optional) | delay | The number of seconds to wait before fencing is started. The default value is 0. |
4.27. RHEV-M REST API Copy linkLink copied to clipboard!
fence_rhevm
, the fence agent for RHEV-M REST API.
luci Field | cluster.conf Attribute | Description |
---|---|---|
Name | name | Name of the RHEV-M REST API fencing device. |
IP Address or Hostname | ipaddr | The IP address or host name assigned to the device. |
IP Port (optional) | ipport | The TCP port to use for connection with the device. |
Login | login | The login name used to access the device. |
Password | passwd | The password used to authenticate the connection to the device. |
Password Script (optional) | passwd_script | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Use SSL | ssl | Use SSL connections to communicate with the device. |
Power Wait (seconds) | power_wait | Number of seconds to wait after issuing a power off or power on command. |
Power Timeout (seconds) | power_timeout | Number of seconds to continue testing for a status change after issuing a power off or power on command. The default value is 20. |
Shell Timeout (seconds) | shell_timeout | Number of seconds to wait for a command prompt after issuing a command. The default value is 3. |
Login Timeout (seconds) | login_timeout | Number of seconds to wait for a command prompt after login. The default value is 5. |
Times to Retry Power On Operation | retry_on | Number of attempts to retry a power on operation. The default value is 1. |
Port (Outlet) Number | port | Physical plug number or name of virtual machine. |
Delay (optional) | delay | The number of seconds to wait before fencing is started. The default value is 0. |
Figure 4.20. RHEV-M REST API
ccs -f cluster.conf --addfencedev rhevmtest1 agent=fence_rhevm ipaddr=192.168.0.1 login=root passwd=password123 \ power_wait=60 ssl=on
ccs -f cluster.conf --addfencedev rhevmtest1 agent=fence_rhevm ipaddr=192.168.0.1 login=root passwd=password123 \
power_wait=60 ssl=on
cluster.conf
entry for the fence_rhevm
device:
<fencedevices> <fencedevice agent="fence_rhevm" ipaddr="192.168.0.1" login="root" name="rhevmtest1" passwd="password123" \ power_wait="60" ssl="on"/> </fencedevices>
<fencedevices>
<fencedevice agent="fence_rhevm" ipaddr="192.168.0.1" login="root" name="rhevmtest1" passwd="password123" \
power_wait="60" ssl="on"/>
</fencedevices>
4.28. SCSI Persistent Reservations Copy linkLink copied to clipboard!
fence_scsi
, the fence agent for SCSI persistent reservations.
Note
- When using SCSI fencing, all nodes in the cluster must register with the same devices so that each node can remove another node's registration key from all the devices it is registered with.
- Devices used for the cluster volumes should be a complete LUN, not partitions. SCSI persistent reservations work on an entire LUN, meaning that access is controlled to each LUN, not individual partitions.
/dev/disk/by-id/
xxx where possible. Devices specified in this format are consistent among all nodes and will point to the same disk, unlike devices specified in a format such as /dev/sda
which can point to different disks from machine to machine and across reboots.
luci Field | cluster.conf Attribute | Description |
---|---|---|
Name | name | A name for the SCSI fence device. |
Unfencing | unfence section of the cluster configuration file | When enabled, this ensures that a fenced node is not re-enabled until the node has been rebooted. This is necessary for non-power fence methods (that is, SAN/storage fencing). When you configure a device that requires unfencing, the cluster must first be stopped and the full configuration including devices and unfencing must be added before the cluster is started. For more information about unfencing a node, see the fence_node (8) man page. |
Node name | nodename | The node name is used to generate the key value used for the current operation. |
Key for current action | key | (overrides node name) Key to use for the current operation. This key should be unique to a node. For the "on" action, the key specifies the key use to register the local node. For the "off" action,this key specifies the key to be removed from the device(s). |
Delay (optional) | delay | The number of seconds to wait before fencing is started. The default value is 0. |
Figure 4.21. SCSI Fencing
ccs -f cluster.conf --addfencedev scsifencetest1 agent=fence_scsi
ccs -f cluster.conf --addfencedev scsifencetest1 agent=fence_scsi
cluster.conf
entry for the fence_scsi
device:
<fencedevices> <<fencedevice agent="fence_scsi" name="scsifencetest1"/> </fencedevices>
<fencedevices>
<<fencedevice agent="fence_scsi" name="scsifencetest1"/>
</fencedevices>
4.29. VMware over SOAP API Copy linkLink copied to clipboard!
fence_vmware_soap
, the fence agent for VMware over SOAP API.
luci Field | cluster.conf Attribute | Description |
---|---|---|
Name | name | Name of the virtual machine fencing device. |
IP Address or Hostname | ipaddr | The IP address or host name assigned to the device. |
IP Port (optional) | ipport | The TCP port to use for connection with the device. The default port is 80, or 443 if Use SSL is selected. |
Login | login | The login name used to access the device. |
Password | passwd | The password used to authenticate the connection to the device. |
Password Script (optional) | passwd_script | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Power Wait (seconds) | power_wait | Number of seconds to wait after issuing a power off or power on command. |
Power Timeout (seconds) | power_timeout | Number of seconds to continue testing for a status change after issuing a power off or power on command. The default value is 20. |
Shell Timeout (seconds) | shell_timeout | Number of seconds to wait for a command prompt after issuing a command. The default value is 3. |
Login Timeout (seconds) | login_timeout | Number of seconds to wait for a command prompt after login. The default value is 5. |
Times to Retry Power On Operation | retry_on | Number of attempts to retry a power on operation. The default value is 1. |
VM name | port | Name of virtual machine in inventory path format (for example, /datacenter/vm/Discovered_virtual_machine/myMachine). |
VM UUID | uuid | The UUID of the virtual machine to fence. |
Delay (optional) | delay | The number of seconds to wait before fencing is started. The default value is 0. |
Use SSL | ssl | Use SSL connections to communicate with the device. |
Figure 4.22. VMware over SOAP Fencing
ccs -f cluster.conf --addfencedev vmwaresoaptest1 agent=fence_vmware_soap login=root passwd=password123 power_wait=60 \ separator=,
ccs -f cluster.conf --addfencedev vmwaresoaptest1 agent=fence_vmware_soap login=root passwd=password123 power_wait=60 \
separator=,
cluster.conf
entry for the fence_vmware_soap
device:
<fencedevices> <fencedevice agent="fence_vmware_soap" ipaddr="192.168.0.1" login="root" name="vmwaresoaptest1" passwd="password123" \ power_wait="60" separator="."/> </fencedevices>
<fencedevices>
<fencedevice agent="fence_vmware_soap" ipaddr="192.168.0.1" login="root" name="vmwaresoaptest1" passwd="password123" \
power_wait="60" separator="."/>
</fencedevices>
4.30. WTI Power Switch Copy linkLink copied to clipboard!
fence_wti
, the fence agent for the WTI network power switch.
luci Field | cluster.conf Attribute | Description |
---|---|---|
Name | name | A name for the WTI power switch connected to the cluster. |
IP Address or Hostname | ipaddr | The IP or address or host name assigned to the device. |
IP Port (optional) | ipport | The TCP port to use to connect to the device. |
Login | login | The login name used to access the device. |
Password | passwd | The password used to authenticate the connection to the device. |
Password Script (optional) | passwd_script | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Force command prompt | cmd_prompt | The command prompt to use. The default value is ['RSM>', '>MPC', 'IPS>', 'TPS>', 'NBB>', 'NPS>', 'VMR>'] |
Power Wait (seconds) | power_wait | Number of seconds to wait after issuing a power off or power on command. |
Power Timeout (seconds) | power_timeout | Number of seconds to continue testing for a status change after issuing a power off or power on command. The default value is 20. |
Shell Timeout (seconds) | shell_timeout | Number of seconds to wait for a command prompt after issuing a command. The default value is 3. |
Login Timeout (seconds) | login_timeout | Number of seconds to wait for a command prompt after login. The default value is 5. |
Times to Retry Power On Operation | retry_on | Number of attempts to retry a power on operation. The default value is 1. |
Use SSH | secure | Indicates that system will use SSH to access the device. When using SSH, you must specify either a password, a password script, or an identity file. |
SSH Options | ssh_options | SSH options to use. The default value is -1 -c blowfish . |
Path to SSH Identity File | identity_file | The identity file for SSH. |
Port | port | Physical plug number or name of virtual machine. |
Figure 4.23. WTI Fencing
ccs -f cluster.conf --addfencedev wtipwrsw1 agent=fence_wti cmd_prompt=VMR> login=root passwd=password123 \ power_wait=60
ccs -f cluster.conf --addfencedev wtipwrsw1 agent=fence_wti cmd_prompt=VMR> login=root passwd=password123 \
power_wait=60
cluster.conf
entry for the fence_wti
device:
<fencedevices> <fencedevice agent="fence_wti" cmd_prompt="VMR>" ipaddr="192.168.0.1" login="root" name="wtipwrsw1" \ passwd="password123" power_wait="60"/> </fencedevices>
<fencedevices>
<fencedevice agent="fence_wti" cmd_prompt="VMR>" ipaddr="192.168.0.1" login="root" name="wtipwrsw1" \
passwd="password123" power_wait="60"/>
</fencedevices>
Appendix A. Revision History Copy linkLink copied to clipboard!
Revision History | |||
---|---|---|---|
Revision 4-2 | Wed Mar 8 2017 | ||
| |||
Revision 4-1 | Fri Dec 16 2016 | ||
| |||
Revision 3-5 | Wed Apr 27 2016 | ||
| |||
Revision 3-4 | Wed Mar 9 2016 | ||
| |||
Revision 2-2 | Wed Jul 8 2015 | ||
| |||
Revision 2-1 | Thu Apr 16 2015 | ||
| |||
Revision 1-13 | Wed Oct 8 2014 | ||
| |||
Revision 1-11 | Thu Aug 7 2014 | ||
| |||
Revision 1-9 | Wed Nov 20 2013 | ||
| |||
Revision 1-4 | Mon Nov 28 2012 | ||
| |||
Revision 1-2 | Mon Nov 28 2012 | ||
|
Index Copy linkLink copied to clipboard!
A
- ACPI
- APC power switch over SNMP fence device , APC Power Switch over SNMP
- APC power switch over telnet/SSH fence device , APC Power Switch over Telnet and SSH
B
- Brocade fabric switch fence device , Brocade Fabric Switch
C
- CISCO MDS fence device , Cisco MDS
- Cisco UCS fence device , Cisco UCS
- cluster administration
- configuring ACPI, Configuring ACPI For Use with Integrated Fence Devices
D
- Dell DRAC 5 fence device , Dell Drac 5
- Dell iDRAC fence device , IPMI over LAN
E
- Eaton network power switch, Eaton Network Power Switch
- Egenera BladeFrame fence device , Egenera BladeFrame
- Emerson network power switch fence device , Emerson Network Power Switch (SNMP interface)
- ePowerSwitch fence device , ePowerSwitch
F
- fence
- configuration, Fencing Pre-Configuration
- devices, Fence Devices
- fence agent
- fence_apc, APC Power Switch over Telnet and SSH
- fence_apc_snmp, APC Power Switch over SNMP
- fence_bladecenter, IBM BladeCenter
- fence_brocade, Brocade Fabric Switch
- fence_cisco_mds, Cisco MDS
- fence_cisco_ucs, Cisco UCS
- fence_drac5, Dell Drac 5
- fence_eaton_snmp, Eaton Network Power Switch
- fence_egenera, Egenera BladeFrame
- fence_emerson, Emerson Network Power Switch (SNMP interface)
- fence_eps, ePowerSwitch
- fence_hpblade, Hewlett-Packard BladeSystem
- fence_ibmblade, IBM BladeCenter over SNMP
- fence_idrac, IPMI over LAN
- fence_ifmib, IF-MIB
- fence_ilo, Hewlett-Packard iLO
- fence_ilo2, Hewlett-Packard iLO
- fence_ilo3, IPMI over LAN
- fence_ilo3_ssh, HP iLO over SSH
- fence_ilo4, IPMI over LAN
- fence_ilo4_ssh, HP iLO over SSH
- fence_ilo_moonshot, HP Moonshot iLO
- fence_ilo_mp, Hewlett-Packard iLO MP
- fence_ilo_ssh, HP iLO over SSH
- fence_imm, IPMI over LAN
- fence_intelmodular, Intel Modular
- fence_ipdu, IBM iPDU
- fence_ipmilan, IPMI over LAN
- fence_kdump, Fence kdump
- fence_mpath, Multipath Persistent Reservation Fencing (Red Hat Enterprise Linux 6.7 and later)
- fence_rhevm, RHEV-M REST API
- fence_rsb, Fujitsu-Siemens RemoteView Service Board (RSB)
- fence_scsi, SCSI Persistent Reservations
- fence_virt, Fence Virt (Serial/VMChannel Mode)
- fence_vmware_soap, VMware over SOAP API
- fence_wti, WTI Power Switch
- fence_xvm, Fence Virt (Multicast Mode)
- fence configuration, Fencing Pre-Configuration, Configuring Fencing with Conga
- SELinux, SELinux
- fence device
- APC power switch over SNMP, APC Power Switch over SNMP
- APC power switch over telnet/SSH, APC Power Switch over Telnet and SSH
- Brocade fabric switch, Brocade Fabric Switch
- Cisco MDS, Cisco MDS
- Cisco UCS, Cisco UCS
- Dell DRAC 5, Dell Drac 5
- Dell iDRAC, IPMI over LAN
- Eaton network power switch, Eaton Network Power Switch
- Egenera BladeFrame, Egenera BladeFrame
- Emerson network power switch, Emerson Network Power Switch (SNMP interface)
- ePowerSwitch, ePowerSwitch
- Fence virt, Fence Virt (Serial/VMChannel Mode)
- Fence virt (Multicast Mode), Fence Virt (Multicast Mode)
- Fujitsu Siemens RemoteView Service Board (RSB), Fujitsu-Siemens RemoteView Service Board (RSB)
- HP BladeSystem, Hewlett-Packard BladeSystem
- HP iLO, Hewlett-Packard iLO
- HP iLO MP, Hewlett-Packard iLO MP
- HP iLO over SSH, HP iLO over SSH
- HP iLO2, Hewlett-Packard iLO
- HP iLO3, IPMI over LAN
- HP iLO3 over SSH, HP iLO over SSH
- HP iLO4, IPMI over LAN
- HP iLO4 over SSH, HP iLO over SSH
- HP Moonshot iLO, HP Moonshot iLO
- IBM BladeCenter, IBM BladeCenter
- IBM BladeCenter SNMP, IBM BladeCenter over SNMP
- IBM Integrated Management Module, IPMI over LAN
- IBM iPDU, IBM iPDU
- IF MIB, IF-MIB
- Intel Modular, Intel Modular
- IPMI LAN, IPMI over LAN
- multipath persistent reservation fencing, Multipath Persistent Reservation Fencing (Red Hat Enterprise Linux 6.7 and later)
- RHEV-M REST API, RHEV-M REST API
- SCSI fencing, SCSI Persistent Reservations
- VMware (SOAP interface), VMware over SOAP API
- WTI power switch, WTI Power Switch
- fence devices, Fence Devices
- Fence virt fence device , Fence Virt (Serial/VMChannel Mode), Fence Virt (Multicast Mode)
- fence_apc fence agent, APC Power Switch over Telnet and SSH
- fence_apc_snmp fence agent, APC Power Switch over SNMP
- fence_bladecenter fence agent, IBM BladeCenter
- fence_brocade fence agent, Brocade Fabric Switch
- fence_cisco_mds fence agent, Cisco MDS
- fence_cisco_ucs fence agent, Cisco UCS
- fence_drac5 fence agent, Dell Drac 5
- fence_eaton_snmp fence agent, Eaton Network Power Switch
- fence_egenera fence agent, Egenera BladeFrame
- fence_emerson fence agent, Emerson Network Power Switch (SNMP interface)
- fence_eps fence agent, ePowerSwitch
- fence_hpblade fence agent, Hewlett-Packard BladeSystem
- fence_ibmblade fence agent, IBM BladeCenter over SNMP
- fence_idrac fence agent, IPMI over LAN
- fence_ifmib fence agent, IF-MIB
- fence_ilo fence agent, Hewlett-Packard iLO
- fence_ilo2 fence agent, Hewlett-Packard iLO
- fence_ilo3 fence agent, IPMI over LAN
- fence_ilo3_ssh fence agent, HP iLO over SSH
- fence_ilo4 fence agent, IPMI over LAN
- fence_ilo4_ssh fence agent, HP iLO over SSH
- fence_ilo_moonshot fence agent, HP Moonshot iLO
- fence_ilo_mp fence agent, Hewlett-Packard iLO MP
- fence_ilo_ssh fence agent, HP iLO over SSH
- fence_imm fence agent, IPMI over LAN
- fence_intelmodular fence agent, Intel Modular
- fence_ipdu fence agent, IBM iPDU
- fence_ipmilan fence agent, IPMI over LAN
- fence_kdump fence agent, Fence kdump
- fence_mpath fence agent, Multipath Persistent Reservation Fencing (Red Hat Enterprise Linux 6.7 and later)
- fence_rhevm fence agent, RHEV-M REST API
- fence_rsb fence agent, Fujitsu-Siemens RemoteView Service Board (RSB)
- fence_scsi fence agent, SCSI Persistent Reservations
- fence_virt fence agent, Fence Virt (Serial/VMChannel Mode)
- fence_vmware_soap fence agent, VMware over SOAP API
- fence_wti fence agent, WTI Power Switch
- fence_xvm fence agent, Fence Virt (Multicast Mode)
- fencing
- fencing configuration, Configuring Fencing with the ccs Command
- Fujitsu Siemens RemoteView Service Board (RSB) fence device, Fujitsu-Siemens RemoteView Service Board (RSB)
H
- HP Bladesystem fence device , Hewlett-Packard BladeSystem
- HP iLO fence device, Hewlett-Packard iLO
- HP iLO MP fence device , Hewlett-Packard iLO MP
- HP iLO over SSH fence device, HP iLO over SSH
- HP iLO2 fence device, Hewlett-Packard iLO
- HP iLO3 fence device, IPMI over LAN
- HP iLO3 over SSH fence device, HP iLO over SSH
- HP iLO4 fence device, IPMI over LAN
- HP iLO4 over SSH fence device, HP iLO over SSH
- HP Moonshot iLO fence device, HP Moonshot iLO
I
- IBM BladeCenter fence device , IBM BladeCenter
- IBM BladeCenter SNMP fence device , IBM BladeCenter over SNMP
- IBM Integrated Management Module fence device , IPMI over LAN
- IBM iPDU fence device , IBM iPDU
- IF MIB fence device , IF-MIB
- integrated fence devices
- configuring ACPI, Configuring ACPI For Use with Integrated Fence Devices
- Intel Modular fence device , Intel Modular
- IPMI LAN fence device , IPMI over LAN
M
- multipath persistent reservation fence device , Multipath Persistent Reservation Fencing (Red Hat Enterprise Linux 6.7 and later)
R
- RHEV-M REST API fence device , RHEV-M REST API
S
- SCSI fencing, SCSI Persistent Reservations
- SELinux
- configuring, SELinux
T
- tables
- fence devices, parameters, Fence Devices
V
- VMware (SOAP interface) fence device , VMware over SOAP API
W
- WTI power switch fence device , WTI Power Switch