Chapter 5. Fencing Controller nodes with STONITH
Fencing is the process of isolating a failed node to protect the cluster and the cluster resources. Without fencing, a failed node might result in data corruption in a cluster.
Director uses Pacemaker to provide a highly available cluster of Controller nodes. Pacemaker uses a process called STONITH to fence failed nodes. STONITH is an acronym for "Shoot the other node in the head".
If a Controller node fails a health check, the Controller node that acts as the Pacemaker designated coordinator (DC) uses the Pacemaker stonith
service to fence the impacted Controller node.
STONITH is disabled by default and requires manual configuration so that Pacemaker can control the power management of each node in the cluster.
Deploying a highly available overcloud without STONITH is not supported. You must configure a STONITH device for each node that is a part of the Pacemaker cluster in a highly available overcloud. For more information on STONITH and Pacemaker, see Fencing in a Red Hat High Availability Cluster and Support Policies for RHEL High Availability Clusters.
For more information on fencing with Pacemaker in Red Hat Enterprise Linux, see:
5.1. Supported fencing agents
When you deploy a high availability environment with fencing, you can choose one of the following fencing agents based on your environment needs. To change the fencing agent, you must configure additional parameters in the fencing.yaml
file, as described in Section 5.2, “Deploying and testing fencing on the overcloud”.
- Intelligent Platform Management Interface (IPMI)
- Default fencing mechanism that RHOSP uses to manage fencing.
- Storage Block Device (SBD)
- Use in deployments with Watchdog devices. The deployment must not use shared storage.
fence_kdump
Use in deployments with the
kdump
crash recovery service. If you choose this agent, make sure you have enough disk space to store the dump files.You can configure this agent as a secondary mechanism in addition to the IPMI,
fence_rhevm
, or Redfish fencing agents. If you configure multiple fencing agents, make sure that you allocate enough time for the first agent to complete the task before the second agent starts the next task.- Redfish
-
Use in deployments with servers that support the DMTF Redfish APIs. To specify this agent, change the value of the
agent
parameter tofence_redfish
in thefencing.yaml
file. For more information about Redfish, see the DTMF Documentation. fence_rhevm
for Red Hat Virtualization (RHV)Use to configure fencing for Controller nodes that run RHV environments. You can generate the
fencing.yaml
file in the same way as you do for IPMI fencing, but you must define thepm_type
parameter in thenodes.json
file to use RHV.By default, the
ssl_insecure
parameter is set to accept self-signed certificates. You can change the parameter value based on your security requirements.ImportantMake sure that you use a role with permissions to create and launch virtual machines in RHV, such as
UserVMManager
.
5.2. Deploying and testing fencing on the overcloud
The fencing configuration process includes the following stages:
- Reviewing the state of STONITH and Pacemaker.
-
Generating the
fencing.yaml
file. - Redeploying the overcloud and testing the configuration.
Prerequisites
Make sure that you can access the nodes.json
file that you created when you registered your Controller nodes in director. This file is a required input for the fencing.yaml
file that you generate during deployment.
Review the state of STONITH and Pacemaker
- Log in to each Controller node as the heat-admin user.
Verify that the cluster is running:
$ sudo pcs status
Example output:
Cluster name: openstackHA Last updated: Wed Jun 24 12:40:27 2015 Last change: Wed Jun 24 11:36:18 2015 Stack: corosync Current DC: lb-c1a2 (2) - partition with quorum Version: 1.1.12-a14efad 3 Nodes configured 141 Resources configured
Verify that STONITH is disabled:
$ sudo pcs property show
Example output:
Cluster Properties: cluster-infrastructure: corosync cluster-name: openstackHA dc-version: 1.1.12-a14efad have-watchdog: false stonith-enabled: false
Generate the fencing.yaml
environment file
Choose one of the following options:
If you use the IPMI or Red Hat Virtualization (RHV) fencing agent, run the following command to generate the
fencing.yaml
environment file:$ openstack overcloud generate fencing --output fencing.yaml nodes.json
Note-
This command converts
ilo
anddrac
power management details to IPMI equivalents. -
Make sure that the
nodes.json
file contains the MAC address of one of the network interfaces (NICs) on the node. For more information, see Registering Nodes for the Overcloud. -
If you use RHV, make sure that you use a role with permissions to create and launch virtual machine, such as
UserVMManager
.
-
This command converts
If you use a different fencing agent, such as Storage Block Device (SBD),
fence_kdump
, or Redfish, generate thefencing.yaml
file manually.NoteIf you use pre-provisioned nodes, you also must create the
fencing.yaml
file manually.
For more information about supported fencing agents, see Section 5.1, “Supported fencing agents”.
Redeploy the overcloud and test the configuration
Run the
overcloud deploy
command and include thefencing.yaml
file that you generated to configure fencing on the Controller nodes:openstack overcloud deploy --templates \ -e /usr/share/openstack-tripleo-heat-templates/environments/network-isolation.yaml \ -e ~/templates/network-environment.yaml \ -e ~/templates/storage-environment.yaml --control-scale 3 --compute-scale 3 --ceph-storage-scale 3 --control-flavor control --compute-flavor Compute --ceph-storage-flavor ceph-storage --ntp-server pool.ntp.org --neutron-network-type vxlan --neutron-tunnel-types vxlan \ -e fencing.yaml
Log in to the overcloud and verify that fencing is configured for each of the Controller nodes:
Check that Pacemaker is configured as the resource manager:
$ source stackrc $ nova list | grep controller $ ssh heat-admin@<controller-x_ip> $ sudo pcs status |grep fence stonith-overcloud-controller-x (stonith:fence_ipmilan): Started overcloud-controller-y
In this example, Pacemaker is configured to use a STONITH resource for each of the Controller nodes that are specified in the
fencing.yaml
file.NoteYou must not configure the
fence-resource
process on the same node that it controls.Run the
pcs stonith show
command to check the fencing resource attributes:$ sudo pcs stonith show <stonith-resource-controller-x>
The STONITH attribute values must match the values in the
fencing.yaml
file.
Verify fencing on the Controller nodes
To test whether fencing works correctly, you trigger fencing by closing all ports on a Controller node and rebooting the server.
Log in to a Controller node:
$ source stackrc $ nova list |grep controller $ ssh heat-admin@<controller-x_ip>
Change to the root user and run the
iptables
command on each port:$ sudo -i iptables -A INPUT -m state --state RELATED,ESTABLISHED -j ACCEPT && iptables -A INPUT -p tcp -m state --state NEW -m tcp --dport 22 -j ACCEPT && iptables -A INPUT -p tcp -m state --state NEW -m tcp --dport 5016 -j ACCEPT && iptables -A INPUT -p udp -m state --state NEW -m udp --dport 5016 -j ACCEPT && iptables -A INPUT ! -i lo -j REJECT --reject-with icmp-host-prohibited && iptables -A OUTPUT -p tcp --sport 22 -j ACCEPT && iptables -A OUTPUT -p tcp --sport 5016 -j ACCEPT && iptables -A OUTPUT -p udp --sport 5016 -j ACCEPT && iptables -A OUTPUT ! -o lo -j REJECT --reject-with icmp-host-prohibited
ImportantThis step drops all connections to the Controller node, which causes the server to reboot.
From a different Controller node, locate the fencing event in the Pacemaker log file:
$ ssh heat-admin@<controller-x_ip> $ less /var/log/cluster/corosync.log (less): /fenc*
If the STONITH service performed the fencing action on the Controller, the log file will show a fencing event.
-
Wait a few minutes and then verify that the rebooted Controller node is running in the cluster again by running the
pcs status
command.
5.3. Viewing STONITH information
To see how STONITH configures your fencing devices, run the pcs stonith show --full
command from the overcloud:
$ sudo pcs stonith show --full Resource: my-ipmilan-for-controller-0 (class=stonith type=fence_ipmilan) 1 Attributes: pcmk_host_list=overcloud-controller-0 ipaddr=10.100.0.51 login=admin passwd=abc lanplus=1 cipher=3 Operations: monitor interval=60s (my-ipmilan-for-controller-0-monitor-interval-60s) Resource: my-ipmilan-for-controller-1 (class=stonith type=fence_ipmilan) Attributes: pcmk_host_list=overcloud-controller-1 ipaddr=10.100.0.52 login=admin passwd=abc lanplus=1 cipher=3 Operations: monitor interval=60s (my-ipmilan-for-controller-1-monitor-interval-60s) Resource: my-ipmilan-for-controller-2 (class=stonith type=fence_ipmilan) Attributes: pcmk_host_list=overcloud-controller-2 ipaddr=10.100.0.53 login=admin passwd=abc lanplus=1 cipher=3 Operations: monitor interval=60s (my-ipmilan-for-controller-2-monitor-interval-60s)
The --full
option returns fencing details about the three Controller nodes.
This output shows the following information for each resource:
- IPMI power management service that the fencing device uses to turn the machines on and off as needed, such as fence_ipmilan.
- IP address of the IPMI interface, such as 10.100.0.51.
- User name to log in with, such as admin.
- Password to use to log in to the node, such as abc.
- Interval in seconds at which each host is monitored, such as 60s.
5.4. Fencing parameters
When you deploy fencing on the overcloud, you generate a fencing.yaml
file with the required parameters to configure fencing. For more information about deploying and testing fencing, see Section 5.2, “Deploying and testing fencing on the overcloud”.
The following example shows the structure of the fencing.yaml
environment file:
parameter_defaults: EnableFencing: true FencingConfig: devices: - agent: fence_ipmilan host_mac: 11:11:11:11:11:11 params: ipaddr: 10.0.0.101 lanplus: true login: admin passwd: InsertComplexPasswordHere pcmk_host_list: host04 privlvl: administrator
This file contains the following parameters:
- EnableFencing
- Enables the fencing functionality for Pacemaker-managed nodes.
- FencingConfig
Lists the fencing devices and the parameters for each device:
-
agent
: Fencing agent name. Red Hat OpenStack Platform only supportsfence_ipmilan
for IPMI. -
host_mac
: The mac address in lowercase of the provisioning interface or any other network interface on the server. You can use this as a unique identifier for the fencing device. -
params
: List of fencing device parameters.
-
- Fencing device parameters
-
auth
: IPMI authentication type (md5
,password
, or none). -
ipaddr
: IPMI IP address. -
ipport
: IPMI port. -
login
: Username for the IPMI device. -
passwd
: Password for the IPMI device. -
lanplus
: Use lanplus to improve security of connection. -
privlvl
: Privilege level on IPMI device -
pcmk_host_list