Variable name | Default Value | Remarks |
---|---|---|
DWH_DELETE_JOB_HOUR | 3 | The time at which a deletion job is run. Specify a value between 0 and 23 , where 0 is midnight. |
DWH_SAMPLING | 60 | The interval, in seconds, at which data is collected into statistical tables. |
DWH_TABLES_KEEP_SAMPLES | 24 | The number of hours that data from DWH_SAMPLING is stored. Data more than two hours old is aggregated into hourly data. |
DWH_TABLES_KEEP_HOURLY | 1440 | The number of hours that hourly data is stored. The default is 60 days. Hourly data more than two days old is aggregated into daily data. |
DWH_TABLES_KEEP_DAILY | 43800 | The number of hours that daily data is stored. The default is five years. |