25.2.4. S3_PING 警告のトラブルシューティング
使用される
S3_PING 設定タイプにより、以下の警告が JBoss Data Grid サーバーの起動時に表示される場合があります。
15:46:03,468 WARN [org.jgroups.conf.ProtocolConfiguration] (MSC service thread 1-7) variable "${jgroups.s3.pre_signed_put_url}" in S3_PING could not be substituted; pre_signed_put_url is removed from properties
15:46:03,468 WARN [org.jgroups.conf.ProtocolConfiguration] (MSC service thread 1-7) variable "${jgroups.s3.pre_signed_put_url}" in S3_PING could not be substituted; pre_signed_put_url is removed from properties
15:46:03,469 WARN [org.jgroups.conf.ProtocolConfiguration] (MSC service thread 1-7) variable "${jgroups.s3.prefix}" in S3_PING could not be substituted; prefix is removed from properties
15:46:03,469 WARN [org.jgroups.conf.ProtocolConfiguration] (MSC service thread 1-7) variable "${jgroups.s3.prefix}" in S3_PING could not be substituted; prefix is removed from properties
15:46:03,469 WARN [org.jgroups.conf.ProtocolConfiguration] (MSC service thread 1-7) variable "${jgroups.s3.pre_signed_delete_url}" in S3_PING could not be substituted; pre_signed_delete_url is removed from properties
15:46:03,469 WARN [org.jgroups.conf.ProtocolConfiguration] (MSC service thread 1-7) variable "${jgroups.s3.pre_signed_delete_url}" in S3_PING could not be substituted; pre_signed_delete_url is removed from properties
それぞれの場合に、警告により不足しているものとしてリストされるプロパティーが
S3_PING 設定では不要であることを確認してください。