Chapter 6. Configuring Fencing with Dual Power Supplies


If your system is configured with redundant power supplies for your system, you must be sure to configure fencing so that your nodes fully shut down when they need to be fenced. If you configure each power supply as a separate fence method, each power supply will be fenced separately; the second power supply will allow the system to continue running when the first power supply is fenced and the system will not be fenced at all. To configure a system with dual power supplies, you must configure your fence devices so that both power supplies are shut off and the system is taken completely down. This requires that you configure two fencing devices inside of a single fencing method.
This chapter provides the procedures for using the Conga configuration tool in a Red Hat cluster to configure fencing with dual power supplies.
Figure 6.1, “Fence Devices with Dual Power Supplies” shows the configuration this procedure yields. In this configuration, there are two APC network power switches, each of which runs on its own separate UPS and has its own unique IP address. Each node in the cluster is connected to a port on each APC switch.

Figure 6.1. Fence Devices with Dual Power Supplies

6.1. Dual Power Fencing Prerequisite Configuration

Table 6.1, “Configuration Prerequisities” summarizes the prerequisite components that have been set up before this procedure begins.
Expand
Table 6.1. Configuration Prerequisities
Component Name Comment
cluster apcclust three-node cluster
cluster node clusternode1.example.com node in cluster apcclust configured with 2 APC switches to administer power supply
cluster node clusternode2.example.com node in cluster apcclust configured with 2 APC switches to administer power supply
cluster node clusternode3.example.com node in cluster apcclust configured with 2 APC switches to administer power supply
IP address 10.15.86.96 IP address for the first APC switch that controls the power for for clusternode1.example.com, clusternode2.example.com, and clusternode3.example.com. This switch runs on its own UPS.
IP address 10.15.86.97 IP address for the second APC switch that controls the power for for clusternode1.example.com, clusternode2.example.com, and clusternode3.example.com. This switch runs on its own UPS.
Table 6.2, “Configuration Prerequisities” summarizes the prerequisite components that have been set up for each of the APC switches before this procedure begins.
Expand
Table 6.2. Configuration Prerequisities
Component Name Comment
login apclogin login value for both of the the APC switches that control the power for for clusternode1.example.com, clusternode2.example.com, and clusternode3.example.com
password apcpword password for both the APC switches that control the power for for clusternode1.example.com, clusternode2.example.com, and clusternode3.example.com
port 1 port number on both of the APC switches that clusternode1.example.com connects to
port 2 port number on both of the APC switches that clusternode2.example.com connects to
port 3 port number on both of the APC switches that clusternode3.example.com connects to
맨 위로 이동
Red Hat logoGithubredditYoutubeTwitter

자세한 정보

평가판, 구매 및 판매

커뮤니티

Red Hat 문서 정보

Red Hat을 사용하는 고객은 신뢰할 수 있는 콘텐츠가 포함된 제품과 서비스를 통해 혁신하고 목표를 달성할 수 있습니다. 최신 업데이트를 확인하세요.

보다 포괄적 수용을 위한 오픈 소스 용어 교체

Red Hat은 코드, 문서, 웹 속성에서 문제가 있는 언어를 교체하기 위해 최선을 다하고 있습니다. 자세한 내용은 다음을 참조하세요.Red Hat 블로그.

Red Hat 소개

Red Hat은 기업이 핵심 데이터 센터에서 네트워크 에지에 이르기까지 플랫폼과 환경 전반에서 더 쉽게 작업할 수 있도록 강화된 솔루션을 제공합니다.

Theme

© 2025 Red Hat