2.5. Storage and File Systems


device-mapper-multipath component
Multipath's queue_without_daemon yes default option queues I/O even though all iSCSI links have been disconnected when the system is shut down, which causes LVM to become unresponsive when scanning all block devices. As a result, the system cannot be shut down. To work around this issue, add the following line into the defaults section of /etc/multipath.conf:
Copy to Clipboard Toggle word wrap
queue_without_daemon no
initscripts component
If the /etc/fstab file contains an NFS mount entry that has the file system check (fsck) enabled, the netfs service responsible for mounting and unmounting NFS file systems initializes the file system check. Because NFS is not a block-level file system, this operation fails, and subsequently also fails the system boot itself. To work around this problem, disable the file system check by setting the sixth vaule for NFS mount entries to 0.
iscsi-initiator-utils component, BZ#739843
iSCSI discovery via a TOE (TCP Offload Engine) interface fails when the iscsiadm -m iface has never been executed. This is due to the iscsiadm -m discovery command not checking interface settings while the iscsiadm -m iface does. To work around this issue, run the iscsiadm -m iface command at least once after installing the iscsi-initiatio-utils package. Once the interface setting is updated, discoveries are performed with no errors.
vdsm component
Attempting to create/extend a storage domain on/with a device that exposes a block size different than 512 bytes such create/extend request to fail. To work around this issue, the storage must be configured to expose a block size of 512 bytes.
kernel component, BZ#606260
The NFSv4 server in Red Hat Enterprise Linux 6 currently allows clients to mount using UDP and advertises NFSv4 over UDP with rpcbind. However, this configuration is not supported by Red Hat and violates the RFC 3530 standard.
lvm2 component
The dracut utility currently only supports one FiberChannel over Ethernet (FCoE) connection to be used to boot from the root device. Consequently, booting from a root device that spans multiple FCoE devices (for example, using RAID, LVM or similar techniques) is not possible.
lvm2 component
The pvmove command cannot currently be used to move mirror devices. However, it is possible to move mirror devices by issuing a sequence of two commands. For mirror images, add a new image on the destination PV and then remove the mirror image on the source PV:
Copy to Clipboard Toggle word wrap
~]$ lvconvert -m +1 <vg/lv> <new PV>
~]$ lvconvert -m -1 <vg/lv> <old PV>
Mirror logs can be handled in a similar fashion:
Copy to Clipboard Toggle word wrap
~]$ lvconvert --mirrorlog core <vg/lv>
~]$ lvconvert --mirrorlog disk <vg/lv> <new PV>
or
Copy to Clipboard Toggle word wrap
~]$ lvconvert --mirrorlog mirrored <vg/lv> <new PV>
~]$ lvconvert --mirrorlog disk <vg/lv> <old PV>
맨 위로 이동
Red Hat logoGithubredditYoutubeTwitter

자세한 정보

평가판, 구매 및 판매

커뮤니티

Red Hat 문서 정보

Red Hat을 사용하는 고객은 신뢰할 수 있는 콘텐츠가 포함된 제품과 서비스를 통해 혁신하고 목표를 달성할 수 있습니다. 최신 업데이트를 확인하세요.

보다 포괄적 수용을 위한 오픈 소스 용어 교체

Red Hat은 코드, 문서, 웹 속성에서 문제가 있는 언어를 교체하기 위해 최선을 다하고 있습니다. 자세한 내용은 다음을 참조하세요.Red Hat 블로그.

Red Hat 소개

Red Hat은 기업이 핵심 데이터 센터에서 네트워크 에지에 이르기까지 플랫폼과 환경 전반에서 더 쉽게 작업할 수 있도록 강화된 솔루션을 제공합니다.

Theme

© 2025 Red Hat, Inc.