7.5. Storage device requirements


Use this section to understand the different storage capacity requirements that you can consider when planning internal mode deployments and upgrades. We generally recommend 12 devices or less per node. This recommendation ensures both that nodes stay below cloud provider dynamic storage device attachment limits, and to limit the recovery time after node failures with local storage devices. Expanding the cluster in multiples of three, one node in each failure domain, is an easy way to satisfy pod placement rules.

Storage nodes should have at least two disks, one for the operating system and the remaining disks for OpenShift Data Foundation components.

참고

You can expand the storage capacity only in the increment of the capacity selected at the time of installation.

7.5.1. Dynamic storage devices

Red Hat OpenShift Data Foundation permits the selection of either 0.5 TiB, 2 TiB or 4 TiB capacities as the request size for dynamic storage device sizes. The number of dynamic storage devices that can run per node is a function of the node size, underlying provisioner limits and resource requirements.

7.5.2. Local storage devices

For local storage deployment, any disk size of 16 TiB or less can be used, and all disks should be of the same size and type. The number of local storage devices that can run per node is a function of the node size and resource requirements. Expanding the cluster in multiples of three, one node in each failure domain, is an easy way to satisfy pod placement rules.

참고

Disk partitioning is not supported, except for DASD-based deployment on IBM Z.

7.5.3. Capacity planning

Always ensure that available storage capacity stays ahead of consumption. Recovery is difficult if available storage capacity is completely exhausted, and requires more intervention than simply adding capacity or deleting or migrating content.

Capacity alerts are issued when cluster storage capacity reaches 75% (near-full) and 85% (full) of total capacity. Always address capacity warnings promptly, and review your storage regularly to ensure that you do not run out of storage space. When you get to 75% (near-full), either free up space or expand the cluster. When you get the 85% (full) alert, it indicates that you have run out of storage space completely and cannot free up space using standard commands. At this point, contact Red Hat Customer Support.

The following tables show example node configurations for Red Hat OpenShift Data Foundation with dynamic storage devices.

Expand
표 7.8. Example initial configurations with 3 nodes
Storage Device sizeStorage Devices per nodeTotal capacityUsable storage capacity

0.5 TiB

1

1.5 TiB

0.5 TiB

2 TiB

1

6 TiB

2 TiB

4 TiB

1

12 TiB

4 TiB

Expand
표 7.9. Example of expanded configurations with 30 nodes (N)
Storage Device size (D)Storage Devices per node (M)Total capacity (D * M * N)Usable storage capacity (D*M*N/3)

0.5 TiB

3

45 TiB

15 TiB

2 TiB

6

360 TiB

120 TiB

4 TiB

9

1080 TiB

360 TiB

Red Hat logoGithubredditYoutubeTwitter

자세한 정보

평가판, 구매 및 판매

커뮤니티

Red Hat 소개

Red Hat은 기업이 핵심 데이터 센터에서 네트워크 에지에 이르기까지 플랫폼과 환경 전반에서 더 쉽게 작업할 수 있도록 강화된 솔루션을 제공합니다.

보다 포괄적 수용을 위한 오픈 소스 용어 교체

Red Hat은 코드, 문서, 웹 속성에서 문제가 있는 언어를 교체하기 위해 최선을 다하고 있습니다. 자세한 내용은 다음을 참조하세요.Red Hat 블로그.

Red Hat 문서 정보

Legal Notice

Theme

© 2026 Red Hat
맨 위로 이동