5.3. STONITH 정보 보기
STONITH가 펜싱 장치를 구성하는 방법을 보려면 오버클라우드에서 pcs stonith show --full
명령을 실행합니다.
sudo pcs stonith show --full
$ sudo pcs stonith show --full
Resource: my-ipmilan-for-controller-0 (class=stonith type=fence_ipmilan)
Attributes: pcmk_host_list=overcloud-controller-0 ipaddr=10.100.0.51 login=admin passwd=abc lanplus=1 cipher=3
Operations: monitor interval=60s (my-ipmilan-for-controller-0-monitor-interval-60s)
Resource: my-ipmilan-for-controller-1 (class=stonith type=fence_ipmilan)
Attributes: pcmk_host_list=overcloud-controller-1 ipaddr=10.100.0.52 login=admin passwd=abc lanplus=1 cipher=3
Operations: monitor interval=60s (my-ipmilan-for-controller-1-monitor-interval-60s)
Resource: my-ipmilan-for-controller-2 (class=stonith type=fence_ipmilan)
Attributes: pcmk_host_list=overcloud-controller-2 ipaddr=10.100.0.53 login=admin passwd=abc lanplus=1 cipher=3
Operations: monitor interval=60s (my-ipmilan-for-controller-2-monitor-interval-60s)
full
옵션은 세 개의 컨트롤러 노드에 대한 펜싱 세부 정보를 반환합니다.
이 출력에서는 각 리소스에 대한 다음 정보를 보여줍니다.
- 펜싱 장치에서 필요에 따라 시스템을 켜거나 켜는 IPMI 전원 관리 서비스(예: fence_ipmilan )입니다.
- IPMI 인터페이스의 IP 주소(예: 10. 100.0.51)입니다.
- admin 과 같이 로그인할 사용자 이름입니다.
- 노드에 로그인하는 데 사용할 암호(예: abc )입니다.
- 각 호스트가 60s 와 같이 모니터링되는 간격(초)입니다.