2.5. Finding available storage devices
Use this procedure to identify the device names for each of the three or more worker nodes that you have labeled with the OpenShift Data Foundation label cluster.ocs.openshift.io/openshift-storage='' before creating PVs for IBM Power.
Procedure
List and verify the name of the worker nodes with the OpenShift Data Foundation label.
$ oc get nodes -l cluster.ocs.openshift.io/openshift-storage=Example output:
NAME STATUS ROLES AGE VERSION worker-0 Ready worker 2d11h v1.23.3+e419edf worker-1 Ready worker 2d11h v1.23.3+e419edf worker-2 Ready worker 2d11h v1.23.3+e419edfLog in to each worker node that is used for OpenShift Data Foundation resources and find the name of the additional disk that you have attached while deploying Openshift Container Platform.
$ oc debug node/<node name>Example output:
$ oc debug node/worker-0 Starting pod/worker-0-debug ... To use host binaries, run `chroot /host` Pod IP: 192.168.0.63 If you don't see a command prompt, try pressing enter. sh-4.4# sh-4.4# chroot /host sh-4.4# lsblk NAME MAJ:MIN RM SIZE RO TYPE MOUNTPOINT loop1 7:1 0 500G 0 loop sda 8:0 0 500G 0 disk sdb 8:16 0 120G 0 disk |-sdb1 8:17 0 4M 0 part |-sdb3 8:19 0 384M 0 part `-sdb4 8:20 0 119.6G 0 part sdc 8:32 0 500G 0 disk sdd 8:48 0 120G 0 disk |-sdd1 8:49 0 4M 0 part |-sdd3 8:51 0 384M 0 part `-sdd4 8:52 0 119.6G 0 part sde 8:64 0 500G 0 disk sdf 8:80 0 120G 0 disk |-sdf1 8:81 0 4M 0 part |-sdf3 8:83 0 384M 0 part `-sdf4 8:84 0 119.6G 0 part sdg 8:96 0 500G 0 disk sdh 8:112 0 120G 0 disk |-sdh1 8:113 0 4M 0 part |-sdh3 8:115 0 384M 0 part `-sdh4 8:116 0 119.6G 0 part sdi 8:128 0 500G 0 disk sdj 8:144 0 120G 0 disk |-sdj1 8:145 0 4M 0 part |-sdj3 8:147 0 384M 0 part `-sdj4 8:148 0 119.6G 0 part sdk 8:160 0 500G 0 disk sdl 8:176 0 120G 0 disk |-sdl1 8:177 0 4M 0 part |-sdl3 8:179 0 384M 0 part `-sdl4 8:180 0 119.6G 0 part /sysroot sdm 8:192 0 500G 0 disk sdn 8:208 0 120G 0 disk |-sdn1 8:209 0 4M 0 part |-sdn3 8:211 0 384M 0 part /boot `-sdn4 8:212 0 119.6G 0 part sdo 8:224 0 500G 0 disk sdp 8:240 0 120G 0 disk |-sdp1 8:241 0 4M 0 part |-sdp3 8:243 0 384M 0 part `-sdp4 8:244 0 119.6G 0 partIn this example, for worker-0, the available local devices of 500G are
sda,sdc,sde,sdg,sdi,sdk,sdm,sdo.- Repeat the above step for all the other worker nodes that have the storage devices to be used by OpenShift Data Foundation. See this Knowledge Base article for more details.