Chapter 5. Configuring an RDMA subsystem for SR-IOV


Remote Direct Memory Access (RDMA) allows direct memory access between two systems without involving the operating system of either system. You can configure an RDMA Container Network Interface (CNI) on Single Root I/O Virtualization (SR-IOV) to enable high-performance, low-latency communication between containers. When you combine RDMA with SR-IOV, you provide a mechanism to expose hardware counters of Mellanox Ethernet devices for use inside Data Plane Development Kit (DPDK) applications.

5.1. Configuring SR-IOV RDMA CNI

Configure an RDMA CNI on SR-IOV.

Note

This procedure applies only to Mellanox devices.

Prerequisites

  • You have installed the OpenShift CLI (oc).
  • You have access to the cluster as a user with the cluster-admin role.
  • You have installed the SR-IOV Network Operator.

Procedure

  1. Create an SriovNetworkPoolConfig CR and save it as sriov-nw-pool.yaml, as shown in the following example:

    Example SriovNetworkPoolConfig CR

    apiVersion: sriovnetwork.openshift.io/v1
    kind: SriovNetworkPoolConfig
    metadata:
      name: worker
      namespace: openshift-sriov-network-operator
    spec:
      maxUnavailable: 1
      nodeSelector:
        matchLabels:
          node-role.kubernetes.io/worker: ""
      rdmaMode: exclusive 
    1
    Copy to Clipboard Toggle word wrap

    1
    Set RDMA network namespace mode to exclusive.
  2. Create the SriovNetworkPoolConfig resource by running the following command:

    $ oc create -f sriov-nw-pool.yaml
    Copy to Clipboard Toggle word wrap
  3. Create an SriovNetworkNodePolicy CR and save it as sriov-node-policy.yaml, as shown in the following example:

    Example SriovNetworkNodePolicy CR

    apiVersion: sriovnetwork.openshift.io/v1
    kind: SriovNetworkNodePolicy
    metadata:
      name: sriov-nic-pf1
      namespace: openshift-sriov-network-operator
    spec:
      deviceType: netdevice
      isRdma: true 
    1
    
      nicSelector:
        pfNames: ["ens3f0np0"]
      nodeSelector:
        node-role.kubernetes.io/worker: ""
      numVfs: 4
      priority: 99
      resourceName: sriov_nic_pf1
    Copy to Clipboard Toggle word wrap

    1
    Activate RDMA mode.
  4. Create the SriovNetworkNodePolicy resource by running the following command:

    $ oc create -f sriov-node-policy.yaml
    Copy to Clipboard Toggle word wrap
  5. Create an SriovNetwork CR and save it as sriov-network.yaml, as shown in the following example:

    Example SriovNetwork CR

    apiVersion: sriovnetwork.openshift.io/v1
    kind: SriovNetwork
    metadata:
      name: sriov-nic-pf1
      namespace: openshift-sriov-network-operator
    spec:
      networkNamespace: sriov-tests
      resourceName: sriov_nic_pf1
        ipam: |-
      metaPlugins: |
        {
          "type": "rdma" 
    1
    
        }
    Copy to Clipboard Toggle word wrap

    1
    Create the RDMA plugin.
  6. Create the SriovNetwork resource by running the following command:

    $ oc create -f sriov-network.yaml
    Copy to Clipboard Toggle word wrap

Verification

  1. Create a Pod CR and save it as sriov-test-pod.yaml, as shown in the following example:

    Example runtime configuration

    apiVersion: v1
    kind: Pod
    metadata:
      name: sample-pod
      annotations:
        k8s.v1.cni.cncf.io/networks: |-
          [
            {
              "name": "net1",
              "mac": "20:04:0f:f1:88:01",
              "ips": ["192.168.10.1/24", "2001::1/64"]
            }
          ]
    spec:
      containers:
      - name: sample-container
        image: <image>
        imagePullPolicy: IfNotPresent
        command: ["sleep", "infinity"]
    Copy to Clipboard Toggle word wrap

  2. Create the test pod by running the following command:

    $ oc create -f sriov-test-pod.yaml
    Copy to Clipboard Toggle word wrap
  3. Log in to the test pod by running the following command:

    $ oc rsh testpod1 -n sriov-tests
    Copy to Clipboard Toggle word wrap
  4. Verify that the path to the hw-counters directory exists by running the following command:

    $ ls /sys/bus/pci/devices/${PCIDEVICE_OPENSHIFT_IO_SRIOV_NIC_PF1}/infiniband/*/ports/1/hw_counters/
    Copy to Clipboard Toggle word wrap

    Example output

    duplicate_request       out_of_buffer req_cqe_flush_error           resp_cqe_flush_error        roce_adp_retrans        roce_slow_restart_trans
    implied_nak_seq_err     out_of_sequence req_remote_access_errors    resp_local_length_error     roce_adp_retrans_to     rx_atomic_requests
    lifespan                packet_seq_err req_remote_invalid_request   resp_remote_access_errors   roce_slow_restart       rx_read_requests
    local_ack_timeout_err  req_cqe_error resp_cqe_error                 rnr_nak_retry_err           roce_slow_restart_cnps  rx_write_requests
    Copy to Clipboard Toggle word wrap

Nach oben
Red Hat logoGithubredditYoutubeTwitter

Lernen

Testen, kaufen und verkaufen

Communitys

Über Red Hat Dokumentation

Wir helfen Red Hat Benutzern, mit unseren Produkten und Diensten innovativ zu sein und ihre Ziele zu erreichen – mit Inhalten, denen sie vertrauen können. Entdecken Sie unsere neuesten Updates.

Mehr Inklusion in Open Source

Red Hat hat sich verpflichtet, problematische Sprache in unserem Code, unserer Dokumentation und unseren Web-Eigenschaften zu ersetzen. Weitere Einzelheiten finden Sie in Red Hat Blog.

Über Red Hat

Wir liefern gehärtete Lösungen, die es Unternehmen leichter machen, plattform- und umgebungsübergreifend zu arbeiten, vom zentralen Rechenzentrum bis zum Netzwerkrand.

Theme

© 2025 Red Hat