Chapter 53. Configuring fencing in a Red Hat High Availability cluster

download PDF

A node that is unresponsive may still be accessing data. The only way to be certain that your data is safe is to fence the node using STONITH. STONITH is an acronym for "Shoot The Other Node In The Head" and it protects your data from being corrupted by rogue nodes or concurrent access. Using STONITH, you can be certain that a node is truly offline before allowing the data to be accessed from another node.

STONITH also has a role to play in the event that a clustered service cannot be stopped. In this case, the cluster uses STONITH to force the whole node offline, thereby making it safe to start the service elsewhere.

For more complete general information on fencing and its importance in a Red Hat High Availability cluster, see Fencing in a Red Hat High Availability Cluster.

You implement STONITH in a Pacemaker cluster by configuring fence devices for the nodes of the cluster.

53.1. Displaying available fence agents and their options

The following commands can be used to view available fencing agents and the available options for specific fencing agents.

This command lists all available fencing agents. When you specify a filter, this command displays only the fencing agents that match the filter.

pcs stonith list [filter]

This command displays the options for the specified fencing agent.

pcs stonith describe [stonith_agent]

For example, the following command displays the options for the fence agent for APC over telnet/SSH.

# pcs stonith describe fence_apc
Stonith options for: fence_apc
  ipaddr (required): IP Address or Hostname
  login (required): Login Name
  passwd: Login password or passphrase
  passwd_script: Script to retrieve password
  cmd_prompt: Force command prompt
  secure: SSH connection
  port (required): Physical plug number or name of virtual machine
  identity_file: Identity file for ssh
  switch: Physical switch number on device
  inet4_only: Forces agent to use IPv4 addresses only
  inet6_only: Forces agent to use IPv6 addresses only
  ipport: TCP port to use for connection with device
  action (required): Fencing Action
  verbose: Verbose mode
  debug: Write debug information to given file
  version: Display version information and exit
  help: Display help and exit
  separator: Separator for CSV created by operation list
  power_timeout: Test X seconds for status change after ON/OFF
  shell_timeout: Wait X seconds for cmd prompt after issuing command
  login_timeout: Wait X seconds for cmd prompt after login
  power_wait: Wait X seconds after issuing ON/OFF
  delay: Wait X seconds before fencing is started
  retry_on: Count of attempts to retry power on
Warning

For fence agents that provide a method option, a value of cycle is unsupported and should not be specified, as it may cause data corruption.

53.2. Creating a fence device

The format for the command to create a fence device is as follows. For a listing of the available fence device creation options, see the pcs stonith -h display.

pcs stonith create stonith_id stonith_device_type [stonith_device_options] [op  operation_action operation_options]

The following command creates a single fencing device for a single node.

# pcs stonith create MyStonith fence_virt pcmk_host_list=f1 op monitor interval=30s

Some fence devices can fence only a single node, while other devices can fence multiple nodes. The parameters you specify when you create a fencing device depend on what your fencing device supports and requires.

  • Some fence devices can automatically determine what nodes they can fence.
  • You can use the pcmk_host_list parameter when creating a fencing device to specify all of the machines that are controlled by that fencing device.
  • Some fence devices require a mapping of host names to the specifications that the fence device understands. You can map host names with the pcmk_host_map parameter when creating a fencing device.

For information on the pcmk_host_list and pcmk_host_map parameters, see General properties of fencing devices.

After configuring a fence device, it is imperative that you test the device to ensure that it is working correctly. For information on testing a fence device, see Testiing a fence device.

53.3. General properties of fencing devices

There are many general properties you can set for fencing devices, as well as various cluster properties that determine fencing behavior.

Any cluster node can fence any other cluster node with any fence device, regardless of whether the fence resource is started or stopped. Whether the resource is started controls only the recurring monitor for the device, not whether it can be used, with the following exceptions:

  • You can disable a fencing device by running the pcs stonith disable stonith_id command. This will prevent any node from using that device.
  • To prevent a specific node from using a fencing device, you can configure location constraints for the fencing resource with the pcs constraint location …​ avoids command.
  • Configuring stonith-enabled=false will disable fencing altogether. Note, however, that Red Hat does not support clusters when fencing is disabled, as it is not suitable for a production environment.

The following table describes the general properties you can set for fencing devices.

Table 53.1. General Properties of Fencing Devices
FieldTypeDefaultDescription

pcmk_host_map

string

 

A mapping of host names to port numbers for devices that do not support host names. For example: node1:1;node2:2,3 tells the cluster to use port 1 for node1 and ports 2 and 3 for node2. As of RHEL 8.7, the pcmk_host_map property supports special characters inside pcmk_host_map values using a backslash in front of the value. For example, you can specify pcmk_host_map="node3:plug\ 1" to include a space in the host alias.

pcmk_host_list

string

 

A list of machines controlled by this device (Optional unless pcmk_host_check=static-list).

pcmk_host_check

string

* static-list if either pcmk_host_list or pcmk_host_map is set

* Otherwise, dynamic-list if the fence device supports the list action

* Otherwise, status if the fence device supports the status action

*Otherwise, none.

How to determine which machines are controlled by the device. Allowed values: dynamic-list (query the device), static-list (check the pcmk_host_list attribute), none (assume every device can fence every machine)

The following table summarizes additional properties you can set for fencing devices. Note that these properties are for advanced use only.

Table 53.2. Advanced Properties of Fencing Devices
FieldTypeDefaultDescription

pcmk_host_argument

string

port

An alternate parameter to supply instead of port. Some devices do not support the standard port parameter or may provide additional ones. Use this to specify an alternate, device-specific parameter that should indicate the machine to be fenced. A value of none can be used to tell the cluster not to supply any additional parameters.

pcmk_reboot_action

string

reboot

An alternate command to run instead of reboot. Some devices do not support the standard commands or may provide additional ones. Use this to specify an alternate, device-specific, command that implements the reboot action.

pcmk_reboot_timeout

time

60s

Specify an alternate timeout to use for reboot actions instead of stonith-timeout. Some devices need much more/less time to complete than normal. Use this to specify an alternate, device-specific, timeout for reboot actions.

pcmk_reboot_retries

integer

2

The maximum number of times to retry the reboot command within the timeout period. Some devices do not support multiple connections. Operations may fail if the device is busy with another task so Pacemaker will automatically retry the operation, if there is time remaining. Use this option to alter the number of times Pacemaker retries reboot actions before giving up.

pcmk_off_action

string

off

An alternate command to run instead of off. Some devices do not support the standard commands or may provide additional ones. Use this to specify an alternate, device-specific, command that implements the off action.

pcmk_off_timeout

time

60s

Specify an alternate timeout to use for off actions instead of stonith-timeout. Some devices need much more or much less time to complete than normal. Use this to specify an alternate, device-specific, timeout for off actions.

pcmk_off_retries

integer

2

The maximum number of times to retry the off command within the timeout period. Some devices do not support multiple connections. Operations may fail if the device is busy with another task so Pacemaker will automatically retry the operation, if there is time remaining. Use this option to alter the number of times Pacemaker retries off actions before giving up.

pcmk_list_action

string

list

An alternate command to run instead of list. Some devices do not support the standard commands or may provide additional ones. Use this to specify an alternate, device-specific, command that implements the list action.

pcmk_list_timeout

time

60s

Specify an alternate timeout to use for list actions. Some devices need much more or much less time to complete than normal. Use this to specify an alternate, device-specific, timeout for list actions.

pcmk_list_retries

integer

2

The maximum number of times to retry the list command within the timeout period. Some devices do not support multiple connections. Operations may fail if the device is busy with another task so Pacemaker will automatically retry the operation, if there is time remaining. Use this option to alter the number of times Pacemaker retries list actions before giving up.

pcmk_monitor_action

string

monitor

An alternate command to run instead of monitor. Some devices do not support the standard commands or may provide additional ones. Use this to specify an alternate, device-specific, command that implements the monitor action.

pcmk_monitor_timeout

time

60s

Specify an alternate timeout to use for monitor actions instead of stonith-timeout. Some devices need much more or much less time to complete than normal. Use this to specify an alternate, device-specific, timeout for monitor actions.

pcmk_monitor_retries

integer

2

The maximum number of times to retry the monitor command within the timeout period. Some devices do not support multiple connections. Operations may fail if the device is busy with another task so Pacemaker will automatically retry the operation, if there is time remaining. Use this option to alter the number of times Pacemaker retries monitor actions before giving up.

pcmk_status_action

string

status

An alternate command to run instead of status. Some devices do not support the standard commands or may provide additional ones. Use this to specify an alternate, device-specific, command that implements the status action.

pcmk_status_timeout

time

60s

Specify an alternate timeout to use for status actions instead of stonith-timeout. Some devices need much more or much less time to complete than normal. Use this to specify an alternate, device-specific, timeout for status actions.

pcmk_status_retries

integer

2

The maximum number of times to retry the status command within the timeout period. Some devices do not support multiple connections. Operations may fail if the device is busy with another task so Pacemaker will automatically retry the operation, if there is time remaining. Use this option to alter the number of times Pacemaker retries status actions before giving up.

pcmk_delay_base

string

0s

Enable a base delay for stonith actions and specify a base delay value. In a cluster with an even number of nodes, configuring a delay can help avoid nodes fencing each other at the same time in an even split. A random delay can be useful when the same fence device is used for all nodes, and differing static delays can be useful on each fencing device when a separate device is used for each node. The overall delay is derived from a random delay value adding this static delay so that the sum is kept below the maximum delay. If you set pcmk_delay_base but do not set pcmk_delay_max, there is no random component to the delay and it will be the value of pcmk_delay_base.

As of Red Hat Enterprise Linux 8.6, you can specify different values for different nodes with the pcmk_delay_base parameter. This allows a single fence device to be used in a two-node cluster, with a different delay for each node. This helps prevent a situation where each node attempts to fence the other node at the same time. To specify different values for different nodes, you map the host names to the delay value for that node using a similar syntax to pcmk_host_map. For example, node1:0;node2:10s would use no delay when fencing node1 and a 10-second delay when fencing node2.

Some individual fence agents implement a "delay" parameter, which is independent of delays configured with a pcmk_delay_* property. If both of these delays are configured, they are added together and thus would generally not be used in conjunction.

pcmk_delay_max

time

0s

Enable a random delay for stonith actions and specify the maximum of random delay. In a cluster with an even number of nodes, configuring a delay can help avoid nodes fencing each other at the same time in an even split. A random delay can be useful when the same fence device is used for all nodes, and differing static delays can be useful on each fencing device when a separate device is used for each node. The overall delay is derived from this random delay value adding a static delay so that the sum is kept below the maximum delay. If you set pcmk_delay_max but do not set pcmk_delay_base there is no static component to the delay.

Some individual fence agents implement a "delay" parameter, which is independent of delays configured with a pcmk_delay_* property. If both of these delays are configured, they are added together and thus would generally not be used in conjunction.

pcmk_action_limit

integer

1

The maximum number of actions that can be performed in parallel on this device. The cluster property concurrent-fencing=true needs to be configured first (this is the default value for RHEL 8.1 and later). A value of -1 is unlimited.

pcmk_on_action

string

on

For advanced use only: An alternate command to run instead of on. Some devices do not support the standard commands or may provide additional ones. Use this to specify an alternate, device-specific, command that implements the on action.

pcmk_on_timeout

time

60s

For advanced use only: Specify an alternate timeout to use for on actions instead of stonith-timeout. Some devices need much more or much less time to complete than normal. Use this to specify an alternate, device-specific, timeout for on actions.

pcmk_on_retries

integer

2

For advanced use only: The maximum number of times to retry the on command within the timeout period. Some devices do not support multiple connections. Operations may fail if the device is busy with another task so Pacemaker will automatically retry the operation, if there is time remaining. Use this option to alter the number of times Pacemaker retries on actions before giving up.

In addition to the properties you can set for individual fence devices, there are also cluster properties you can set that determine fencing behavior, as described in the following table.

Table 53.3. Cluster Properties that Determine Fencing Behavior
OptionDefaultDescription

stonith-enabled

true

Indicates that failed nodes and nodes with resources that cannot be stopped should be fenced. Protecting your data requires that you set this true.

If true, or unset, the cluster will refuse to start resources unless one or more STONITH resources have been configured also.

Red Hat only supports clusters with this value set to true.

stonith-action

reboot

Action to send to STONITH device. Allowed values: reboot, off. The value poweroff is also allowed, but is only used for legacy devices.

stonith-timeout

60s

How long to wait for a STONITH action to complete.

stonith-max-attempts

10

How many times fencing can fail for a target before the cluster will no longer immediately re-attempt it.

stonith-watchdog-timeout

 

The maximum time to wait until a node can be assumed to have been killed by the hardware watchdog. It is recommended that this value be set to twice the value of the hardware watchdog timeout. This option is needed only if watchdog-only SBD configuration is used for fencing.

concurrent-fencing

true (RHEL 8.1 and later)

Allow fencing operations to be performed in parallel.

fence-reaction

stop

(Red Hat Enterprise Linux 8.2 and later) Determines how a cluster node should react if notified of its own fencing. A cluster node may receive notification of its own fencing if fencing is misconfigured, or if fabric fencing is in use that does not cut cluster communication. Allowed values are stop to attempt to immediately stop Pacemaker and stay stopped, or panic to attempt to immediately reboot the local node, falling back to stop on failure.

Although the default value for this property is stop, the safest choice for this value is panic, which attempts to immediately reboot the local node. If you prefer the stop behavior, as is most likely to be the case in conjunction with fabric fencing, it is recommended that you set this explicitly.

For information on setting cluster properties, see Setting and removing cluster properties.

53.4. Testing a fence device

Fencing is a fundamental part of the Red Hat Cluster infrastructure and it is important to validate or test that fencing is working properly.

Procedure

Use the following procedure to test a fence device.

  1. Use ssh, telnet, HTTP, or whatever remote protocol is used to connect to the device to manually log in and test the fence device or see what output is given. For example, if you will be configuring fencing for an IPMI-enabled device, then try to log in remotely with ipmitool. Take note of the options used when logging in manually because those options might be needed when using the fencing agent.

    If you are unable to log in to the fence device, verify that the device is pingable, there is nothing such as a firewall configuration that is preventing access to the fence device, remote access is enabled on the fencing device, and the credentials are correct.

  2. Run the fence agent manually, using the fence agent script. This does not require that the cluster services are running, so you can perform this step before the device is configured in the cluster. This can ensure that the fence device is responding properly before proceeding.

    Note

    These examples use the fence_ipmilan fence agent script for an iLO device. The actual fence agent you will use and the command that calls that agent will depend on your server hardware. You should consult the man page for the fence agent you are using to determine which options to specify. You will usually need to know the login and password for the fence device and other information related to the fence device.

    The following example shows the format you would use to run the fence_ipmilan fence agent script with -o status parameter to check the status of the fence device interface on another node without actually fencing it. This allows you to test the device and get it working before attempting to reboot the node. When running this command, you specify the name and password of an iLO user that has power on and off permissions for the iLO device.

    # fence_ipmilan -a ipaddress -l username -p password -o status

    The following example shows the format you would use to run the fence_ipmilan fence agent script with the -o reboot parameter. Running this command on one node reboots the node managed by this iLO device.

    # fence_ipmilan -a ipaddress -l username -p password -o reboot

    If the fence agent failed to properly do a status, off, on, or reboot action, you should check the hardware, the configuration of the fence device, and the syntax of your commands. In addition, you can run the fence agent script with the debug output enabled. The debug output is useful for some fencing agents to see where in the sequence of events the fencing agent script is failing when logging into the fence device.

    # fence_ipmilan -a ipaddress -l username -p password -o status -D /tmp/$(hostname)-fence_agent.debug

    When diagnosing a failure that has occurred, you should ensure that the options you specified when manually logging in to the fence device are identical to what you passed on to the fence agent with the fence agent script.

    For fence agents that support an encrypted connection, you may see an error due to certificate validation failing, requiring that you trust the host or that you use the fence agent’s ssl-insecure parameter. Similarly, if SSL/TLS is disabled on the target device, you may need to account for this when setting the SSL parameters for the fence agent.

    Note

    If the fence agent that is being tested is a fence_drac, fence_ilo, or some other fencing agent for a systems management device that continues to fail, then fall back to trying fence_ipmilan. Most systems management cards support IPMI remote login and the only supported fencing agent is fence_ipmilan.

  3. Once the fence device has been configured in the cluster with the same options that worked manually and the cluster has been started, test fencing with the pcs stonith fence command from any node (or even multiple times from different nodes), as in the following example. The pcs stonith fence command reads the cluster configuration from the CIB and calls the fence agent as configured to execute the fence action. This verifies that the cluster configuration is correct.

    # pcs stonith fence node_name

    If the pcs stonith fence command works properly, that means the fencing configuration for the cluster should work when a fence event occurs. If the command fails, it means that cluster management cannot invoke the fence device through the configuration it has retrieved. Check for the following issues and update your cluster configuration as needed.

    • Check your fence configuration. For example, if you have used a host map you should ensure that the system can find the node using the host name you have provided.
    • Check whether the password and user name for the device include any special characters that could be misinterpreted by the bash shell. Making sure that you enter passwords and user names surrounded by quotation marks could address this issue.
    • Check whether you can connect to the device using the exact IP address or host name you specified in the pcs stonith command. For example, if you give the host name in the stonith command but test by using the IP address, that is not a valid test.
    • If the protocol that your fence device uses is accessible to you, use that protocol to try to connect to the device. For example many agents use ssh or telnet. You should try to connect to the device with the credentials you provided when configuring the device, to see if you get a valid prompt and can log in to the device.

      If you determine that all your parameters are appropriate but you still have trouble connecting to your fence device, you can check the logging on the fence device itself, if the device provides that, which will show if the user has connected and what command the user issued. You can also search through the /var/log/messages file for instances of stonith and error, which could give some idea of what is transpiring, but some agents can provide additional information.

  4. Once the fence device tests are working and the cluster is up and running, test an actual failure. To do this, take an action in the cluster that should initiate a token loss.

    • Take down a network. How you take a network depends on your specific configuration. In many cases, you can physically pull the network or power cables out of the host. For information on simulating a network failure, see What is the proper way to simulate a network failure on a RHEL Cluster?.

      Note

      Disabling the network interface on the local host rather than physically disconnecting the network or power cables is not recommended as a test of fencing because it does not accurately simulate a typical real-world failure.

    • Block corosync traffic both inbound and outbound using the local firewall.

      The following example blocks corosync, assuming the default corosync port is used, firewalld is used as the local firewall, and the network interface used by corosync is in the default firewall zone:

      # firewall-cmd --direct --add-rule ipv4 filter OUTPUT 2 -p udp --dport=5405 -j DROP
      # firewall-cmd --add-rich-rule='rule family="ipv4" port port="5405" protocol="udp" drop
    • Simulate a crash and panic your machine with sysrq-trigger. Note, however, that triggering a kernel panic can cause data loss; it is recommended that you disable your cluster resources first.

      # echo c > /proc/sysrq-trigger

53.5. Configuring fencing levels

Pacemaker supports fencing nodes with multiple devices through a feature called fencing topologies. To implement topologies, create the individual devices as you normally would and then define one or more fencing levels in the fencing topology section in the configuration.

Pacemaker processes fencing levels as follows:

  • Each level is attempted in ascending numeric order, starting at 1.
  • If a device fails, processing terminates for the current level. No further devices in that level are exercised and the next level is attempted instead.
  • If all devices are successfully fenced, then that level has succeeded and no other levels are tried.
  • The operation is finished when a level has passed (success), or all levels have been attempted (failed).

Use the following command to add a fencing level to a node. The devices are given as a comma-separated list of stonith ids, which are attempted for the node at that level.

pcs stonith level add level node devices

The following command lists all of the fencing levels that are currently configured.

pcs stonith level

In the following example, there are two fence devices configured for node rh7-2: an ilo fence device called my_ilo and an apc fence device called my_apc. These commands set up fence levels so that if the device my_ilo fails and is unable to fence the node, then Pacemaker will attempt to use the device my_apc. This example also shows the output of the pcs stonith level command after the levels are configured.

# pcs stonith level add 1 rh7-2 my_ilo
# pcs stonith level add 2 rh7-2 my_apc
# pcs stonith level
 Node: rh7-2
  Level 1 - my_ilo
  Level 2 - my_apc

The following command removes the fence level for the specified node and devices. If no nodes or devices are specified then the fence level you specify is removed from all nodes.

pcs stonith level remove level  [node_id] [stonith_id] ... [stonith_id]

The following command clears the fence levels on the specified node or stonith id. If you do not specify a node or stonith id, all fence levels are cleared.

pcs stonith level clear [node]|stonith_id(s)]

If you specify more than one stonith id, they must be separated by a comma and no spaces, as in the following example.

# pcs stonith level clear dev_a,dev_b

The following command verifies that all fence devices and nodes specified in fence levels exist.

pcs stonith level verify

You can specify nodes in fencing topology by a regular expression applied on a node name and by a node attribute and its value. For example, the following commands configure nodes node1, node2, and node3 to use fence devices apc1 and apc2, and nodes node4, node5, and node6 to use fence devices apc3 and apc4.

# pcs stonith level add 1 "regexp%node[1-3]" apc1,apc2
# pcs stonith level add 1 "regexp%node[4-6]" apc3,apc4

The following commands yield the same results by using node attribute matching.

# pcs node attribute node1 rack=1
# pcs node attribute node2 rack=1
# pcs node attribute node3 rack=1
# pcs node attribute node4 rack=2
# pcs node attribute node5 rack=2
# pcs node attribute node6 rack=2
# pcs stonith level add 1 attrib%rack=1 apc1,apc2
# pcs stonith level add 1 attrib%rack=2 apc3,apc4

53.6. Configuring fencing for redundant power supplies

When configuring fencing for redundant power supplies, the cluster must ensure that when attempting to reboot a host, both power supplies are turned off before either power supply is turned back on.

If the node never completely loses power, the node may not release its resources. This opens up the possibility of nodes accessing these resources simultaneously and corrupting them.

You need to define each device only once and to specify that both are required to fence the node, as in the following example.

# pcs stonith create apc1 fence_apc_snmp ipaddr=apc1.example.com login=user passwd='7a4D#1j!pz864' pcmk_host_map="node1.example.com:1;node2.example.com:2"

# pcs stonith create apc2 fence_apc_snmp ipaddr=apc2.example.com login=user passwd='7a4D#1j!pz864' pcmk_host_map="node1.example.com:1;node2.example.com:2"

# pcs stonith level add 1 node1.example.com apc1,apc2
# pcs stonith level add 1 node2.example.com apc1,apc2

53.7. Displaying configured fence devices

The following command shows all currently configured fence devices. If a stonith_id is specified, the command shows the options for that configured stonith device only. If the --full option is specified, all configured stonith options are displayed.

pcs stonith config [stonith_id] [--full]

53.8. Exporting fence devices as pcs commands

As of Red Hat Enterprise Linux 8.7, you can display the pcs commands that can be used to re-create configured fence devices on a different system using the --output-format=cmd option of the pcs stonith config command.

The following commands create a fence_apc_snmp fence device and display the pcs command you can use to re-create the device.

# pcs stonith create myapc fence_apc_snmp ip="zapc.example.com" pcmk_host_map="z1.example.com:1;z2.example.com:2" username="apc" password="apc"
# pcs stonith config --output-format=cmd
Warning: Only 'text' output format is supported for stonith levels
pcs stonith create --no-default-ops --force -- myapc fence_apc_snmp \
  ip=zapc.example.com password=apc 'pcmk_host_map=z1.example.com:1;z2.example.com:2' username=apc \
  op \
    monitor interval=60s id=myapc-monitor-interval-60s

53.9. Modifying and deleting fence devices

Modify or add options to a currently configured fencing device with the following command.

pcs stonith update stonith_id [stonith_device_options]

Updating a SCSI fencing device with the pcs stonith update command causes a restart of all resources running on the same node where the stonith resource was running. As of RHEL 8.5, you can use either version of the following command to update SCSI devices without causing a restart of other cluster resources. As of RHEL 8.7, SCSI fencing devices can be configured as multipath devices.

pcs stonith update-scsi-devices stonith_id set device-path1 device-path2
pcs stonith update-scsi-devices stonith_id add device-path1 remove device-path2

Use the following command to remove a fencing device from the current configuration.

pcs stonith delete stonith_id

53.10. Manually fencing a cluster node

You can fence a node manually with the following command. If you specify --off this will use the off API call to stonith which will turn the node off instead of rebooting it.

pcs stonith fence node [--off]

In a situation where no fence device is able to fence a node even if it is no longer active, the cluster may not be able to recover the resources on the node. If this occurs, after manually ensuring that the node is powered down you can enter the following command to confirm to the cluster that the node is powered down and free its resources for recovery.

Warning

If the node you specify is not actually off, but running the cluster software or services normally controlled by the cluster, data corruption/cluster failure will occur.

pcs stonith confirm node

53.11. Disabling a fence device

To disable a fencing device/resource, run the pcs stonith disable command.

The following command disables the fence device myapc.

# pcs stonith disable myapc

53.12. Preventing a node from using a fencing device

To prevent a specific node from using a fencing device, you can configure location constraints for the fencing resource.

The following example prevents fence device node1-ipmi from running on node1.

# pcs constraint location node1-ipmi avoids node1

53.13. Configuring ACPI for use with integrated fence devices

If your cluster uses integrated fence devices, you must configure ACPI (Advanced Configuration and Power Interface) to ensure immediate and complete fencing.

If a cluster node is configured to be fenced by an integrated fence device, disable ACPI Soft-Off for that node. Disabling ACPI Soft-Off allows an integrated fence device to turn off a node immediately and completely rather than attempting a clean shutdown (for example, shutdown -h now). Otherwise, if ACPI Soft-Off is enabled, an integrated fence device can take four or more seconds to turn off a node (see the note that follows). In addition, if ACPI Soft-Off is enabled and a node panics or freezes during shutdown, an integrated fence device may not be able to turn off the node. Under those circumstances, fencing is delayed or unsuccessful. Consequently, when a node is fenced with an integrated fence device and ACPI Soft-Off is enabled, a cluster recovers slowly or requires administrative intervention to recover.

Note

The amount of time required to fence a node depends on the integrated fence device used. Some integrated fence devices perform the equivalent of pressing and holding the power button; therefore, the fence device turns off the node in four to five seconds. Other integrated fence devices perform the equivalent of pressing the power button momentarily, relying on the operating system to turn off the node; therefore, the fence device turns off the node in a time span much longer than four to five seconds.

  • The preferred way to disable ACPI Soft-Off is to change the BIOS setting to "instant-off" or an equivalent setting that turns off the node without delay, as described in "Disabling ACPI Soft-Off with the Bios" below.

Disabling ACPI Soft-Off with the BIOS may not be possible with some systems. If disabling ACPI Soft-Off with the BIOS is not satisfactory for your cluster, you can disable ACPI Soft-Off with one of the following alternate methods:

  • Setting HandlePowerKey=ignore in the /etc/systemd/logind.conf file and verifying that the node node turns off immediately when fenced, as described in "Disabling ACPI Soft-Off in the logind.conf file", below. This is the first alternate method of disabling ACPI Soft-Off.
  • Appending acpi=off to the kernel boot command line, as described in "Disabling ACPI completely in the GRUB 2 file", below. This is the second alternate method of disabling ACPI Soft-Off, if the preferred or the first alternate method is not available.

    Important

    This method completely disables ACPI; some computers do not boot correctly if ACPI is completely disabled. Use this method only if the other methods are not effective for your cluster.

53.13.1. Disabling ACPI Soft-Off with the BIOS

You can disable ACPI Soft-Off by configuring the BIOS of each cluster node with the following procedure.

Note

The procedure for disabling ACPI Soft-Off with the BIOS may differ among server systems. You should verify this procedure with your hardware documentation.

Procedure

  1. Reboot the node and start the BIOS CMOS Setup Utility program.
  2. Navigate to the Power menu (or equivalent power management menu).
  3. At the Power menu, set the Soft-Off by PWR-BTTN function (or equivalent) to Instant-Off (or the equivalent setting that turns off the node by means of the power button without delay). The BIOS CMOS Setup Utiliy example below shows a Power menu with ACPI Function set to Enabled and Soft-Off by PWR-BTTN set to Instant-Off.

    Note

    The equivalents to ACPI Function, Soft-Off by PWR-BTTN, and Instant-Off may vary among computers. However, the objective of this procedure is to configure the BIOS so that the computer is turned off by means of the power button without delay.

  4. Exit the BIOS CMOS Setup Utility program, saving the BIOS configuration.
  5. Verify that the node turns off immediately when fenced. For information on testing a fence device, see Testing a fence device.

BIOS CMOS Setup Utility:

`Soft-Off by PWR-BTTN` set to
`Instant-Off`

+---------------------------------------------|-------------------+
|    ACPI Function             [Enabled]      |    Item Help      |
|    ACPI Suspend Type         [S1(POS)]      |-------------------|
|  x Run VGABIOS if S3 Resume   Auto          |   Menu Level   *  |
|    Suspend Mode              [Disabled]     |                   |
|    HDD Power Down            [Disabled]     |                   |
|    Soft-Off by PWR-BTTN      [Instant-Off   |                   |
|    CPU THRM-Throttling       [50.0%]        |                   |
|    Wake-Up by PCI card       [Enabled]      |                   |
|    Power On by Ring          [Enabled]      |                   |
|    Wake Up On LAN            [Enabled]      |                   |
|  x USB KB Wake-Up From S3     Disabled      |                   |
|    Resume by Alarm           [Disabled]     |                   |
|  x  Date(of Month) Alarm       0            |                   |
|  x  Time(hh:mm:ss) Alarm       0 :  0 :     |                   |
|    POWER ON Function         [BUTTON ONLY   |                   |
|  x KB Power ON Password       Enter         |                   |
|  x Hot Key Power ON           Ctrl-F1       |                   |
|                                             |                   |
|                                             |                   |
+---------------------------------------------|-------------------+

This example shows ACPI Function set to Enabled, and Soft-Off by PWR-BTTN set to Instant-Off.

53.13.2. Disabling ACPI Soft-Off in the logind.conf file

To disable power-key handing in the /etc/systemd/logind.conf file, use the following procedure.

Procedure

  1. Define the following configuration in the /etc/systemd/logind.conf file:

    HandlePowerKey=ignore
  2. Restart the systemd-logind service:

    # systemctl restart systemd-logind.service
  3. Verify that the node turns off immediately when fenced. For information on testing a fence device, see Testing a fence device.

53.13.3. Disabling ACPI completely in the GRUB 2 file

You can disable ACPI Soft-Off by appending acpi=off to the GRUB menu entry for a kernel.

Important

This method completely disables ACPI; some computers do not boot correctly if ACPI is completely disabled. Use this method only if the other methods are not effective for your cluster.

Procedure

Use the following procedure to disable ACPI in the GRUB 2 file:

  1. Use the --args option in combination with the --update-kernel option of the grubby tool to change the grub.cfg file of each cluster node as follows:

    # grubby --args=acpi=off --update-kernel=ALL
  2. Reboot the node.
  3. Verify that the node turns off immediately when fenced. For information on testing a fence device, see Testing a fence device.
Red Hat logoGithubRedditYoutubeTwitter

Lernen

Testen, kaufen und verkaufen

Communitys

Über Red Hat Dokumentation

Wir helfen Red Hat Benutzern, mit unseren Produkten und Diensten innovativ zu sein und ihre Ziele zu erreichen – mit Inhalten, denen sie vertrauen können.

Mehr Inklusion in Open Source

Red Hat hat sich verpflichtet, problematische Sprache in unserem Code, unserer Dokumentation und unseren Web-Eigenschaften zu ersetzen. Weitere Einzelheiten finden Sie in Red Hat Blog.

Über Red Hat

Wir liefern gehärtete Lösungen, die es Unternehmen leichter machen, plattform- und umgebungsübergreifend zu arbeiten, vom zentralen Rechenzentrum bis zum Netzwerkrand.

© 2024 Red Hat, Inc.