Virtualization


OpenShift Container Platform 4.9

OpenShift Virtualization installation, usage, and release notes

Red Hat OpenShift Documentation Team

Abstract

This document provides information about how to use OpenShift Virtualization in OpenShift Container Platform.

Chapter 1. About OpenShift Virtualization

Learn about OpenShift Virtualization’s capabilities and support scope.

1.1. What you can do with OpenShift Virtualization

OpenShift Virtualization is an add-on to OpenShift Container Platform that allows you to run and manage virtual machine workloads alongside container workloads.

OpenShift Virtualization adds new objects into your OpenShift Container Platform cluster via Kubernetes custom resources to enable virtualization tasks. These tasks include:

  • Creating and managing Linux and Windows virtual machines
  • Connecting to virtual machines through a variety of consoles and CLI tools
  • Importing and cloning existing virtual machines
  • Managing network interface controllers and storage disks attached to virtual machines
  • Live migrating virtual machines between nodes

An enhanced web console provides a graphical portal to manage these virtualized resources alongside the OpenShift Container Platform cluster containers and infrastructure.

OpenShift Virtualization is tested with OpenShift Container Storage (OCS) and designed to use with OCS features for the best experience.

You can use OpenShift Virtualization with the OVN-Kubernetes, OpenShift SDN, or one of the other certified default Container Network Interface (CNI) network providers listed in Certified OpenShift CNI Plugins.

1.1.1. OpenShift Virtualization supported cluster version

OpenShift Virtualization 4.9 is supported for use on OpenShift Container Platform 4.9 clusters. To use the latest z-stream release of OpenShift Virtualization, you must first upgrade to the latest version of OpenShift Container Platform.

Chapter 2. Start here with OpenShift Virtualization

Use the following tables to find content to help you learn about and use OpenShift Virtualization.

2.1. Cluster administrator

LearnPlanDeployAdditional resources

Learn about OpenShift Virtualization

Configuring your cluster for OpenShift Virtualization

Updating your node network configuration

Getting Support

Learn more about OpenShift Container Platform

Plan storage for virtual machine disks

Configuring CSI volumes

 

Learn about virtual machine live migration

 

Installing OpenShift Virtualization using the OpenShift Virtualization console or CLI

 

Learn about node maintenance

   

2.2. Virtualization administrator

LearnDeployManageUse

Learn about OpenShift Virtualization

Connecting virtual machines to the default pod network for virtual machines and external networks

Enabling the virtctl client

Importing virtual machines with the Migration Toolkit for containers

Learn about storage features for virtual machine disks

Customizing the storage profile

Using the CLI tools

Using live migration

 

Creating boot sources and attaching them to templates

Viewing logs and events

 
 

Updating boot source templates

Monitoring virtual machine health

 

2.3. Virtual machine administrator / developer

LearnUseManageAdditional resources

Learn about OpenShift Virtualization

Enabling the virtctl client

Viewing logs and events

Getting Support

 

Creating virtual machines

Monitoring virtual machine health

 
 

Managing virtual machines instances

Creating and managing virtual machine snapshots

 
 

Controlling virtual machine states

  
 

Accessing the virtual machine consoles

  
 

Pass configuration data to virtual machines using secrets, configuration maps, and service accounts

  

Chapter 3. OpenShift Virtualization release notes

3.1. About Red Hat OpenShift Virtualization

Red Hat OpenShift Virtualization enables you to bring traditional virtual machines (VMs) into OpenShift Container Platform where they run alongside containers, and are managed as native Kubernetes objects.

OpenShift Virtualization is represented by the OpenShift Virtualization icon.

You can use OpenShift Virtualization with either the OVN-Kubernetes or the OpenShiftSDN default Container Network Interface (CNI) network provider.

Learn more about what you can do with OpenShift Virtualization.

3.1.1. OpenShift Virtualization supported cluster version

OpenShift Virtualization 4.9 is supported for use on OpenShift Container Platform 4.9 clusters. To use the latest z-stream release of OpenShift Virtualization, you must first upgrade to the latest version of OpenShift Container Platform.

3.1.2. Supported guest operating systems

OpenShift Virtualization guests can use the following operating systems:

  • Red Hat Enterprise Linux 6, 7, and 8.
  • Red Hat Enterprise Linux 9 Alpha (Technology Preview).
  • Microsoft Windows Server 2012 R2, 2016, and 2019.
  • Microsoft Windows 10.

Other operating system templates shipped with OpenShift Virtualization are not supported.

3.2. Making open source more inclusive

Red Hat is committed to replacing problematic language in our code, documentation, and web properties. We are beginning with these four terms: master, slave, blacklist, and whitelist. Because of the enormity of this endeavor, these changes will be implemented gradually over several upcoming releases. For more details, see our CTO Chris Wright’s message.

3.3. New and changed features

  • OpenShift Virtualization is certified in Microsoft’s Windows Server Virtualization Validation Program (SVVP) to run Windows Server workloads.

    The SVVP Certification applies to:

    • Red Hat Enterprise Linux CoreOS workers. In the Microsoft SVVP Catalog, they are named Red Hat OpenShift Container Platform 4 on RHEL CoreOS.
    • Intel and AMD CPUs.
  • If your OpenShift Virtualization Operator subscription used any update channel other than stable, it is now automatically subscribed to the stable channel. This single update channel delivers z-stream and minor version updates and ensures that your OpenShift Virtualization and OpenShift Container Platform versions are compatible.

3.3.1. Quick starts

  • Quick start tours are available for several OpenShift Virtualization features. To view the tours, click the Help icon ? in the menu bar on the header of the OpenShift Virtualization console and then select Quick Starts. You can filter the available tours by entering the virtualization keyword in the Filter field.

3.3.2. Installation

  • You can now deploy OpenShift Virtualization on FIPS-enabled clusters.
  • You can now download the virtctl client even if the cluster is offline by using the ConsoleCLIDownload custom resource (CR).

3.3.3. Networking

3.3.4. Storage

  • You can use storage profiles to set a default cloning method for a storage class, creating a cloning strategy. Setting cloning strategies can be helpful, for example, if your storage vendor only supports certain cloning methods. It also allows you to select a method that limits resource usage or maximizes performance. In addition to previously available cloning methods such as snapshots and host-assisted cloning, you can now specify csi-clone as the default cloning behavior, which uses the CSI clone API to efficiently clone an existing volume without using an interim volume snapshot.

3.3.5. Web console

  • You can use the OpenShift Virtualization dashboard in the web console to get data on resource consumption for virtual machines and associated pods. The dashboard provides visual representations of cluster metrics so you can quickly understand the state of your cluster.

3.4. Removed features

Removed features are not supported in the current release.

  • Importing a single virtual machine from Red Hat Virtualization (RHV) or VMware is removed from OpenShift Virtualization 4.9. This feature is replaced by the Migration Toolkit for Virtualization.

3.5. Technology Preview features

Some features in this release are currently in Technology Preview. These experimental features are not intended for production use. Note the following scope of support on the Red Hat Customer Portal for these features:

Technology Preview Features Support Scope

3.6. Bug fixes

  • The Template provider menu in the web console no longer offers "Red Hat Supported" as a template search filter, to avoid confusion with the "Red Hat Provided" filter. (BZ#1952737)
  • The KubeVirt plugin now checks the API version available and uses the correct version, rather than defaulting to the v1 API version, which resulted in an API mismatch and prevented virtual machine creation. (BZ#1977037), (BZ#1979114)
  • The Red Hat Enterprise Linux (RHEL) 6 template is no longer prioritized in the web console. (BZ#1978200)
  • The Red Hat Enterprise Linux (RHEL) 6 template is no longer labeled as a community-provided template in the web console. (BZ#1978202)
  • The web console can now retrieve more information from virtual machines, including time zone and number of active users. (BZ#1979190)
  • Live migration between nodes with incompatible CPUs is now prevented on clusters containing nodes that are not configured identically. (BZ#1760028)
  • If you initially deployed OpenShift Virtualization version 2.4.z or earlier, you can now upgrade to the latest version without using a workaround. (BZ#1986989)
  • If you run OpenShift Virtualization 2.6.5 with OpenShift Container Platform 4.8 or later, you can now create a virtual machine from the Customize wizard. (BZ#1979116)
  • RHV VM import no longer fails if the VM affinity policy is set to Migratable rather than Pinned. (BZ#1977277)
  • Selecting CreateWith Import wizard on the Virtualization page of the OpenShift Virtualization web console no longer results in an erroneous error message. (BZ#1974812)

3.7. Known issues

  • If you use OpenShift Virtualization on OpenShift Container Platform 4.9.4 or earlier with the Border Gateway Protocol daemon running and then you modify the network interface with BPG route entries, the BPG routes will be converted into static routes. nmstate-1.0.2-14.el8_4.noarch, which ships with OpenShift Container Platform 4.9.4, does not handle the Bird Internet Routing Daemon protocol correctly.

    You can prevent this issue by upgrading your cluster to OpenShift Container Platform 4.9.5 or later. If BGP routes have already been converted to static routes, you must remove the static routes from the network interface and add the routes manually.

  • Updating to OpenShift Virtualization 4.9.6 causes some virtual machines (VMs) to get stuck in a live migration loop. This occurs if the spec.volumes.containerDisk.path field in the VM manifest is set to a relative path.

    • As a workaround, delete and recreate the VM manifest, setting the value of the spec.volumes.containerDisk.path field to an absolute path. You can then update OpenShift Virtualization.
  • If you hot-plug a virtual disk and then force delete the virt-launcher pod, you might lose data. This is due to a race condition that can cause the VM disk’s contents to be wiped from the persistent volume. (BZ#2007397)
  • Editing a virtual machine fails if the VM references a deleted template that was provided by OpenShift Virtualization before version 4.8. In OpenShift Virtualization 4.8 and later, deleted OpenShift Virtualization-provided templates are automatically recreated by the OpenShift Virtualization Operator.
  • If a cloning operation is initiated before the source is available to be cloned, the operation stalls indefinitely. This is because the clone authorization expires before the cloning operation starts. (BZ#1855182)

    • As a workaround, delete the DataVolume object that is requesting the clone. When the source is available, recreate the DataVolume object that you deleted so that the cloning operation can complete successfully.
  • If your OpenShift Container Platform cluster uses OVN-Kubernetes as the default Container Network Interface (CNI) provider, you cannot attach a Linux bridge or bonding to the default interface of a host because of a change in the host network topology of OVN-Kubernetes. (BZ#1885605)

    • As a workaround, you can use a secondary network interface connected to your host, or switch to the OpenShift SDN default CNI provider.
  • Running virtual machines that cannot be live migrated might block an OpenShift Container Platform cluster upgrade. This includes virtual machines that use hostpath provisioner storage or SR-IOV network interfaces.

    • As a workaround, you can reconfigure the virtual machines so that they can be powered off during a cluster upgrade. In the spec section of the virtual machine configuration file:

      1. Remove the evictionStrategy: LiveMigrate field. See Configuring virtual machine eviction strategy for more information on how to configure eviction strategy.
      2. Set the runStrategy field to Always.
    • As a workaround, set the default CPU model by running the following command:

      Note

      You must make this change before starting the virtual machines that support live migration.

      $ oc annotate --overwrite -n openshift-cnv hyperconverged kubevirt-hyperconverged kubevirt.kubevirt.io/jsonpatch='[
        {
            "op": "add",
            "path": "/spec/configuration/cpuModel",
            "value": "<cpu_model>" 1
        }
      ]'
      1
      Replace <cpu_model> with the actual CPU model value. You can determine this value by running oc describe node <node> for all nodes and looking at the cpu-model-<name> labels. Select the CPU model that is present on all of your nodes.
  • If you enter the wrong credentials for the RHV Manager while importing a RHV VM, the Manager might lock the admin user account because the vm-import-operator tries repeatedly to connect to the RHV API. (BZ#1887140)

    • To unlock the account, log in to the Manager and enter the following command:

      $ ovirt-aaa-jdbc-tool user unlock admin
  • If you run OpenShift Virtualization 2.6.5 with OpenShift Container Platform 4.8 or later, various issues occur. You can avoid these issues by upgrading OpenShift Virtualization to version 4.8 or later.

    • In the web console, if you navigate to the Virtualization page and select CreateWith YAML the following error message is displayed:

      The server doesn't have a resource type "kind: VirtualMachine, apiVersion: kubevirt.io/v1"
      • As a workaround, edit the VirtualMachine manifest so the apiVersion is kubevirt.io/v1alpha3. For example:

        apiVersion: kubevirt.io/v1alpha3
        kind: VirtualMachine
        metadata:
          annotations:
        ...

        (BZ#1979114)

    • When connecting to the VNC console by using the OpenShift Virtualization web console, the VNC console always fails to respond.

      • As a workaround, create the virtual machine from the CLI or upgrade to OpenShift Virtualization 4.8.

        (BZ#1977037)

Chapter 4. Installing

4.1. Preparing your cluster for OpenShift Virtualization

Review this section before you install OpenShift Virtualization to ensure that your cluster meets the requirements.

Important

You can use any installation method, including user-provisioned, installer-provisioned, or assisted installer, to deploy OpenShift Container Platform. However, the installation method and the cluster topology might affect OpenShift Virtualization functionality, such as snapshots or live migration.

Single-node OpenShift behavior

You can install OpenShift Virtualization on a single-node cluster. See About single-node OpenShift for more information. Single-node OpenShift does not support high availability, which results in the following differences:

FIPS mode

If you install your cluster in FIPS mode, no additional setup is required for OpenShift Virtualization.

4.1.1. Hardware and operating system requirements

Review the following hardware and operating system requirements for OpenShift Virtualization.

Supported platforms

  • On-premise bare metal servers
  • Amazon Web Services bare metal instances
Important

Installing OpenShift Virtualization on an AWS bare metal instance is a Technology Preview feature only. Technology Preview features are not supported with Red Hat production service level agreements (SLAs) and might not be functionally complete. Red Hat does not recommend using them in production. These features provide early access to upcoming product features, enabling customers to test functionality and provide feedback during the development process.

For more information about the support scope of Red Hat Technology Preview features, see Technology Preview Features Support Scope.

  • Bare metal instances or servers offered by other cloud providers are not supported.

CPU requirements

  • Supported by Red Hat Enterprise Linux (RHEL) 8
  • Support for Intel 64 or AMD64 CPU extensions
  • Intel VT or AMD-V hardware virtualization extensions enabled
  • NX (no execute) flag enabled

Storage requirements

  • Supported by OpenShift Container Platform

Operating system requirements

  • Red Hat Enterprise Linux CoreOS (RHCOS) installed on worker nodes

    Note

    RHEL worker nodes are not supported.

Additional resources

4.1.2. Physical resource overhead requirements

OpenShift Virtualization is an add-on to OpenShift Container Platform and imposes additional overhead that you must account for when planning a cluster. Each cluster machine must accommodate the following overhead requirements in addition to the OpenShift Container Platform requirements. Oversubscribing the physical resources in a cluster can affect performance.

Important

The numbers noted in this documentation are based on Red Hat’s test methodology and setup. These numbers can vary based on your own individual setup and environments.

4.1.2.1. Memory overhead

Calculate the memory overhead values for OpenShift Virtualization by using the equations below.

Cluster memory overhead

Memory overhead per infrastructure node ≈ 150 MiB

Memory overhead per worker node ≈ 360 MiB

Additionally, OpenShift Virtualization environment resources require a total of 2179 MiB of RAM that is spread across all infrastructure nodes.

Virtual machine memory overhead

Memory overhead per virtual machine ≈ (1.002 * requested memory) + 146 MiB  \
                + 8 MiB * (number of vCPUs) \ 1
             + 16 MiB * (number of graphics devices) 2

1
Number of virtual CPUs requested by the virtual machine
2
Number of virtual graphics cards requested by the virtual machine

If your environment includes a Single Root I/O Virtualization (SR-IOV) network device or a Graphics Processing Unit (GPU), allocate 1 GiB additional memory overhead for each device.

4.1.2.2. CPU overhead

Calculate the cluster processor overhead requirements for OpenShift Virtualization by using the equation below. The CPU overhead per virtual machine depends on your individual setup.

Cluster CPU overhead

CPU overhead for infrastructure nodes ≈ 4 cores

OpenShift Virtualization increases the overall utilization of cluster level services such as logging, routing, and monitoring. To account for this workload, ensure that nodes that host infrastructure components have capacity allocated for 4 additional cores (4000 millicores) distributed across those nodes.

CPU overhead for worker nodes ≈ 2 cores + CPU overhead per virtual machine

Each worker node that hosts virtual machines must have capacity for 2 additional cores (2000 millicores) for OpenShift Virtualization management workloads in addition to the CPUs required for virtual machine workloads.

Virtual machine CPU overhead

If dedicated CPUs are requested, there is a 1:1 impact on the cluster CPU overhead requirement. Otherwise, there are no specific rules about how many CPUs a virtual machine requires.

4.1.2.3. Storage overhead

Use the guidelines below to estimate storage overhead requirements for your OpenShift Virtualization environment.

Cluster storage overhead

Aggregated storage overhead per node ≈ 10 GiB

10 GiB is the estimated on-disk storage impact for each node in the cluster when you install OpenShift Virtualization.

Virtual machine storage overhead

Storage overhead per virtual machine depends on specific requests for resource allocation within the virtual machine. The request could be for ephemeral storage on the node or storage resources hosted elsewhere in the cluster. OpenShift Virtualization does not currently allocate any additional ephemeral storage for the running container itself.

4.1.2.4. Example

As a cluster administrator, if you plan to host 10 virtual machines in the cluster, each with 1 GiB of RAM and 2 vCPUs, the memory impact across the cluster is 11.68 GiB. The estimated on-disk storage impact for each node in the cluster is 10 GiB and the CPU impact for worker nodes that host virtual machine workloads is a minimum of 2 cores.

4.1.3. Object maximums

You must consider the following tested object maximums when planning your cluster:

4.1.4. Restricted network environments

If you install OpenShift Virtualization in a restricted environment with no internet connectivity, you must configure Operator Lifecycle Manager for restricted networks.

If you have limited internet connectivity, you can configure proxy support in Operator Lifecycle Manager to access the Red Hat-provided OperatorHub.

4.1.5. Live migration

Live migration has the following requirements:

  • Shared storage with ReadWriteMany (RWX) access mode
  • Sufficient RAM and network bandwidth
  • Appropriate CPUs with sufficient capacity on the worker nodes. If the CPUs have different capacities, live migration might be very slow or fail.

4.1.6. Snapshots and cloning

See OpenShift Virtualization storage features for snapshot and cloning requirements.

4.1.7. Cluster high-availability options

You can configure one of the following high-availability (HA) options for your cluster:

  • Automatic high availability for installer-provisioned infrastructure (IPI) is available by deploying machine health checks.

    Note

    In OpenShift Container Platform clusters installed using installer-provisioned infrastructure and with MachineHealthCheck properly configured, if a node fails the MachineHealthCheck and becomes unavailable to the cluster, it is recycled. What happens next with VMs that ran on the failed node depends on a series of conditions. See About RunStrategies for virtual machines for more detailed information about the potential outcomes and how RunStrategies affect those outcomes.

  • Automatic high availability for both IPI and non-IPI is available by using the Node Health Check Operator on the OpenShift Container Platform cluster to deploy the NodeHealthCheck controller. The controller identifies unhealthy nodes and uses the Self Node Remediation Operator to remediate the unhealthy nodes.

    Important

    Node Health Check Operator is a Technology Preview feature only. Technology Preview features are not supported with Red Hat production service level agreements (SLAs) and might not be functionally complete. Red Hat does not recommend using them in production. These features provide early access to upcoming product features, enabling customers to test functionality and provide feedback during the development process.

    For more information about the support scope of Red Hat Technology Preview features, see Technology Preview Features Support Scope.

  • High availability for any platform is available by using either a monitoring system or a qualified human to monitor node availability. When a node is lost, shut it down and run oc delete node <lost_node>.

    Note

    Without an external monitoring system or a qualified human monitoring node health, virtual machines lose high availability.

4.2. Specifying nodes for OpenShift Virtualization components

Specify the nodes where you want to deploy OpenShift Virtualization Operators, workloads, and controllers by configuring node placement rules.

Note

You can configure node placement for some components after installing OpenShift Virtualization, but there must not be virtual machines present if you want to configure node placement for workloads.

4.2.1. About node placement for virtualization components

You might want to customize where OpenShift Virtualization deploys its components to ensure that:

  • Virtual machines only deploy on nodes that are intended for virtualization workloads.
  • Operators only deploy on infrastructure nodes.
  • Certain nodes are unaffected by OpenShift Virtualization. For example, you have workloads unrelated to virtualization running on your cluster, and you want those workloads to be isolated from OpenShift Virtualization.
4.2.1.1. How to apply node placement rules to virtualization components

You can specify node placement rules for a component by editing the corresponding object directly or by using the web console.

  • For the OpenShift Virtualization Operators that Operator Lifecycle Manager (OLM) deploys, edit the OLM Subscription object directly. Currently, you cannot configure node placement rules for the Subscription object by using the web console.
  • For components that the OpenShift Virtualization Operators deploy, edit the HyperConverged object directly or configure it by using the web console during OpenShift Virtualization installation.
  • For the hostpath provisioner, edit the HostPathProvisioner object directly or configure it by using the web console.

    Warning

    You must schedule the hostpath provisioner and the virtualization components on the same nodes. Otherwise, virtualization pods that use the hostpath provisioner cannot run.

Depending on the object, you can use one or more of the following rule types:

nodeSelector
Allows pods to be scheduled on nodes that are labeled with the key-value pair or pairs that you specify in this field. The node must have labels that exactly match all listed pairs.
affinity
Enables you to use more expressive syntax to set rules that match nodes with pods. Affinity also allows for more nuance in how the rules are applied. For example, you can specify that a rule is a preference, rather than a hard requirement, so that pods are still scheduled if the rule is not satisfied.
tolerations
Allows pods to be scheduled on nodes that have matching taints. If a taint is applied to a node, that node only accepts pods that tolerate the taint.
4.2.1.2. Node placement in the OLM Subscription object

To specify the nodes where OLM deploys the OpenShift Virtualization Operators, edit the Subscription object during OpenShift Virtualization installation. You can include node placement rules in the spec.config field, as shown in the following example:

apiVersion: operators.coreos.com/v1alpha1
kind: Subscription
metadata:
  name: hco-operatorhub
  namespace: openshift-cnv
spec:
  source: redhat-operators
  sourceNamespace: openshift-marketplace
  name: kubevirt-hyperconverged
  startingCSV: kubevirt-hyperconverged-operator.v4.9.7
  channel: "stable"
  config: 1
1
The config field supports nodeSelector and tolerations, but it does not support affinity.
4.2.1.3. Node placement in the HyperConverged object

To specify the nodes where OpenShift Virtualization deploys its components, you can include the nodePlacement object in the HyperConverged Cluster custom resource (CR) file that you create during OpenShift Virtualization installation. You can include nodePlacement under the spec.infra and spec.workloads fields, as shown in the following example:

apiVersion: hco.kubevirt.io/v1beta1
kind: HyperConverged
metadata:
  name: kubevirt-hyperconverged
  namespace: openshift-cnv
spec:
  infra:
    nodePlacement: 1
    ...
  workloads:
    nodePlacement:
    ...
1
The nodePlacement fields support nodeSelector, affinity, and tolerations fields.
4.2.1.4. Node placement in the HostPathProvisioner object

You can configure node placement rules in the spec.workload field of the HostPathProvisioner object that you create when you install the hostpath provisioner.

apiVersion: hostpathprovisioner.kubevirt.io/v1beta1
kind: HostPathProvisioner
metadata:
  name: hostpath-provisioner
spec:
  imagePullPolicy: IfNotPresent
  pathConfig:
    path: "</path/to/backing/directory>"
    useNamingPrefix: false
  workload: 1
1
The workload field supports nodeSelector, affinity, and tolerations fields.
4.2.1.5. Additional resources

4.2.2. Example manifests

The following example YAML files use nodePlacement, affinity, and tolerations objects to customize node placement for OpenShift Virtualization components.

4.2.2.1. Operator Lifecycle Manager Subscription object
4.2.2.1.1. Example: Node placement with nodeSelector in the OLM Subscription object

In this example, nodeSelector is configured so that OLM places the OpenShift Virtualization Operators on nodes that are labeled with example.io/example-infra-key = example-infra-value.

apiVersion: operators.coreos.com/v1alpha1
kind: Subscription
metadata:
  name: hco-operatorhub
  namespace: openshift-cnv
spec:
  source: redhat-operators
  sourceNamespace: openshift-marketplace
  name: kubevirt-hyperconverged
  startingCSV: kubevirt-hyperconverged-operator.v4.9.7
  channel: "stable"
  config:
    nodeSelector:
      example.io/example-infra-key: example-infra-value
4.2.2.1.2. Example: Node placement with tolerations in the OLM Subscription object

In this example, nodes that are reserved for OLM to deploy OpenShift Virtualization Operators are labeled with the key=virtualization:NoSchedule taint. Only pods with the matching tolerations are scheduled to these nodes.

apiVersion: operators.coreos.com/v1alpha1
kind: Subscription
metadata:
  name: hco-operatorhub
  namespace: openshift-cnv
spec:
  source: redhat-operators
  sourceNamespace: openshift-marketplace
  name: kubevirt-hyperconverged
  startingCSV: kubevirt-hyperconverged-operator.v4.9.7
  channel: "stable"
  config:
    tolerations:
    - key: "key"
      operator: "Equal"
      value: "virtualization"
      effect: "NoSchedule"
4.2.2.2. HyperConverged object
4.2.2.2.1. Example: Node placement with nodeSelector in the HyperConverged Cluster CR

In this example, nodeSelector is configured so that infrastructure resources are placed on nodes that are labeled with example.io/example-infra-key = example-infra-value and workloads are placed on nodes labeled with example.io/example-workloads-key = example-workloads-value.

apiVersion: hco.kubevirt.io/v1beta1
kind: HyperConverged
metadata:
  name: kubevirt-hyperconverged
  namespace: openshift-cnv
spec:
  infra:
    nodePlacement:
      nodeSelector:
        example.io/example-infra-key: example-infra-value
  workloads:
    nodePlacement:
      nodeSelector:
        example.io/example-workloads-key: example-workloads-value
4.2.2.2.2. Example: Node placement with affinity in the HyperConverged Cluster CR

In this example, affinity is configured so that infrastructure resources are placed on nodes that are labeled with example.io/example-infra-key = example-value and workloads are placed on nodes labeled with example.io/example-workloads-key = example-workloads-value. Nodes that have more than eight CPUs are preferred for workloads, but if they are not available, pods are still scheduled.

apiVersion: hco.kubevirt.io/v1beta1
kind: HyperConverged
metadata:
  name: kubevirt-hyperconverged
  namespace: openshift-cnv
spec:
  infra:
    nodePlacement:
      affinity:
        nodeAffinity:
          requiredDuringSchedulingIgnoredDuringExecution:
            nodeSelectorTerms:
            - matchExpressions:
              - key: example.io/example-infra-key
                operator: In
                values:
                - example-infra-value
  workloads:
    nodePlacement:
      affinity:
        nodeAffinity:
          requiredDuringSchedulingIgnoredDuringExecution:
            nodeSelectorTerms:
            - matchExpressions:
              - key: example.io/example-workloads-key
                operator: In
                values:
                - example-workloads-value
          preferredDuringSchedulingIgnoredDuringExecution:
          - weight: 1
            preference:
              matchExpressions:
              - key: example.io/num-cpus
                operator: Gt
                values:
                - 8
4.2.2.2.3. Example: Node placement with tolerations in the HyperConverged Cluster CR

In this example, nodes that are reserved for OpenShift Virtualization components are labeled with the key=virtualization:NoSchedule taint. Only pods with the matching tolerations are scheduled to these nodes.

apiVersion: hco.kubevirt.io/v1beta1
kind: HyperConverged
metadata:
  name: kubevirt-hyperconverged
  namespace: openshift-cnv
spec:
  workloads:
    nodePlacement:
      tolerations:
      - key: "key"
        operator: "Equal"
        value: "virtualization"
        effect: "NoSchedule"
4.2.2.3. HostPathProvisioner object
4.2.2.3.1. Example: Node placement with nodeSelector in the HostPathProvisioner object

In this example, nodeSelector is configured so that workloads are placed on nodes labeled with example.io/example-workloads-key = example-workloads-value.

apiVersion: hostpathprovisioner.kubevirt.io/v1beta1
kind: HostPathProvisioner
metadata:
  name: hostpath-provisioner
spec:
  imagePullPolicy: IfNotPresent
  pathConfig:
    path: "</path/to/backing/directory>"
    useNamingPrefix: false
  workload:
    nodeSelector:
      example.io/example-workloads-key: example-workloads-value

4.3. Installing OpenShift Virtualization using the web console

Install OpenShift Virtualization to add virtualization functionality to your OpenShift Container Platform cluster.

You can use the OpenShift Container Platform 4.9 web console to subscribe to and deploy the OpenShift Virtualization Operators.

4.3.1. Installing the OpenShift Virtualization Operator

You can install the OpenShift Virtualization Operator from the OpenShift Container Platform web console.

Prerequisites

  • Install OpenShift Container Platform 4.9 on your cluster.
  • Log in to the OpenShift Container Platform web console as a user with cluster-admin permissions.

Procedure

  1. From the Administrator perspective, click OperatorsOperatorHub.
  2. In the Filter by keyword field, type OpenShift Virtualization.
  3. Select the OpenShift Virtualization tile.
  4. Read the information about the Operator and click Install.
  5. On the Install Operator page:

    1. Select stable from the list of available Update Channel options. This ensures that you install the version of OpenShift Virtualization that is compatible with your OpenShift Container Platform version.
    2. For Installed Namespace, ensure that the Operator recommended namespace option is selected. This installs the Operator in the mandatory openshift-cnv namespace, which is automatically created if it does not exist.

      Warning

      Attempting to install the OpenShift Virtualization Operator in a namespace other than openshift-cnv causes the installation to fail.

    3. For Approval Strategy, it is highly recommended that you select Automatic, which is the default value, so that OpenShift Virtualization automatically updates when a new version is available in the stable update channel.

      While it is possible to select the Manual approval strategy, this is inadvisable because of the high risk that it presents to the supportability and functionality of your cluster. Only select Manual if you fully understand these risks and cannot use Automatic.

      Warning

      Because OpenShift Virtualization is only supported when used with the corresponding OpenShift Container Platform version, missing OpenShift Virtualization updates can cause your cluster to become unsupported.

  6. Click Install to make the Operator available to the openshift-cnv namespace.
  7. When the Operator installs successfully, click Create HyperConverged.
  8. Optional: Configure Infra and Workloads node placement options for OpenShift Virtualization components.
  9. Click Create to launch OpenShift Virtualization.

Verification

  • Navigate to the WorkloadsPods page and monitor the OpenShift Virtualization pods until they are all Running. After all the pods display the Running state, you can use OpenShift Virtualization.

4.3.2. Next steps

You might want to additionally configure the following components:

  • The hostpath provisioner is a local storage provisioner designed for OpenShift Virtualization. If you want to configure local storage for virtual machines, you must enable the hostpath provisioner first.

4.4. Installing OpenShift Virtualization using the CLI

Install OpenShift Virtualization to add virtualization functionality to your OpenShift Container Platform cluster. You can subscribe to and deploy the OpenShift Virtualization Operators by using the command line to apply manifests to your cluster.

Note

To specify the nodes where you want OpenShift Virtualization to install its components, configure node placement rules.

4.4.1. Prerequisites

  • Install OpenShift Container Platform 4.9 on your cluster.
  • Install the OpenShift CLI (oc).
  • Log in as a user with cluster-admin privileges.

4.4.2. Subscribing to the OpenShift Virtualization catalog by using the CLI

Before you install OpenShift Virtualization, you must subscribe to the OpenShift Virtualization catalog. Subscribing gives the openshift-cnv namespace access to the OpenShift Virtualization Operators.

To subscribe, configure Namespace, OperatorGroup, and Subscription objects by applying a single manifest to your cluster.

Procedure

  1. Create a YAML file that contains the following manifest:

    apiVersion: v1
    kind: Namespace
    metadata:
      name: openshift-cnv
    ---
    apiVersion: operators.coreos.com/v1
    kind: OperatorGroup
    metadata:
      name: kubevirt-hyperconverged-group
      namespace: openshift-cnv
    spec:
      targetNamespaces:
        - openshift-cnv
    ---
    apiVersion: operators.coreos.com/v1alpha1
    kind: Subscription
    metadata:
      name: hco-operatorhub
      namespace: openshift-cnv
    spec:
      source: redhat-operators
      sourceNamespace: openshift-marketplace
      name: kubevirt-hyperconverged
      startingCSV: kubevirt-hyperconverged-operator.v4.9.7
      channel: "stable" 1
    1
    Using the stable channel ensures that you install the version of OpenShift Virtualization that is compatible with your OpenShift Container Platform version.
  2. Create the required Namespace, OperatorGroup, and Subscription objects for OpenShift Virtualization by running the following command:

    $ oc apply -f <file name>.yaml
Note

You can configure certificate rotation parameters in the YAML file.

4.4.3. Deploying the OpenShift Virtualization Operator by using the CLI

You can deploy the OpenShift Virtualization Operator by using the oc CLI.

Prerequisites

  • An active subscription to the OpenShift Virtualization catalog in the openshift-cnv namespace.

Procedure

  1. Create a YAML file that contains the following manifest:

    apiVersion: hco.kubevirt.io/v1beta1
    kind: HyperConverged
    metadata:
      name: kubevirt-hyperconverged
      namespace: openshift-cnv
    spec:
  2. Deploy the OpenShift Virtualization Operator by running the following command:

    $ oc apply -f <file_name>.yaml

Verification

  • Ensure that OpenShift Virtualization deployed successfully by watching the PHASE of the cluster service version (CSV) in the openshift-cnv namespace. Run the following command:

    $ watch oc get csv -n openshift-cnv

    The following output displays if deployment was successful:

    Example output

    NAME                                      DISPLAY                    VERSION   REPLACES   PHASE
    kubevirt-hyperconverged-operator.v4.9.7   OpenShift Virtualization   4.9.7                Succeeded

4.4.4. Next steps

You might want to additionally configure the following components:

  • The hostpath provisioner is a local storage provisioner designed for OpenShift Virtualization. If you want to configure local storage for virtual machines, you must enable the hostpath provisioner first.

4.5. Enabling the virtctl client

The virtctl client is a command-line utility for managing OpenShift Virtualization resources. It is available for Linux, macOS, and Windows distributions.

4.5.1. Downloading and installing the virtctl client

4.5.1.1. Downloading the virtctl client

Download the virtctl client by using the link provided in the ConsoleCLIDownload custom resource (CR).

Procedure

  1. View the ConsoleCLIDownload object by running the following command:

    $ oc get ConsoleCLIDownload virtctl-clidownloads-kubevirt-hyperconverged -o yaml
  2. Download the virtctl client by using the link listed for your distribution.
4.5.1.2. Installing the virtctl client

Extract and install the virtctl client after downloading from the appropriate location for your operating system.

Prerequisites

  • You must have downloaded the virtctl client.

Procedure

  • For Linux:

    1. Extract the tarball. The following CLI command extracts it into the same directory as the tarball:

      $ tar -xvf <virtctl-version-distribution.arch>.tar.gz
    2. Navigate the extracted folder hierachy and run the following command to make the virtctl binary executable:

      $ chmod +x <virtctl-file-name>
    3. Move the virtctl binary to a directory in your PATH environment variable.
    4. To check your path, run the following command:

      $ echo $PATH
  • For Windows users:

    1. Unpack and unzip the archive.
    2. Navigate the extracted folder hierarchy and double-click the virtctl executable file to install the client.
    3. Move the virtctl binary to a directory in your PATH environment variable.
    4. To check your path, run the following command:

      C:\> path
  • For macOS users:

    1. Unpack and unzip the archive.
    2. Move the virtctl binary to a directory in your PATH environment variable.
    3. To check your path, run the following command:

      echo $PATH

4.5.2. Additional setup options

4.5.2.1. Installing the virtctl client using the yum utility

Install the virtctl client from the kubevirt-virtctl package.

Procedure

  • Install the kubevirt-virtctl package:

    # yum install kubevirt-virtctl
4.5.2.2. Enabling OpenShift Virtualization repositories

Red Hat offers OpenShift Virtualization repositories for both Red Hat Enterprise Linux 8 and Red Hat Enterprise Linux 7:

  • Red Hat Enterprise Linux 8 repository: cnv-4.9-for-rhel-8-x86_64-rpms
  • Red Hat Enterprise Linux 7 repository: rhel-7-server-cnv-4.9-rpms

The process for enabling the repository in subscription-manager is the same in both platforms.

Procedure

  • Enable the appropriate OpenShift Virtualization repository for your system by running the following command:

    # subscription-manager repos --enable <repository>

4.5.3. Additional resources

4.6. Uninstalling OpenShift Virtualization using the web console

You can uninstall OpenShift Virtualization by using the OpenShift Container Platform web console.

4.6.1. Prerequisites

4.6.2. Deleting the OpenShift Virtualization Operator Deployment custom resource

To uninstall OpenShift Virtualization, you must first delete the OpenShift Virtualization Operator Deployment custom resource.

Prerequisites

  • Create the OpenShift Virtualization Operator Deployment custom resource.

Procedure

  1. From the OpenShift Container Platform web console, select openshift-cnv from the Projects list.
  2. Navigate to the OperatorsInstalled Operators page.
  3. Click OpenShift Virtualization.
  4. Click the OpenShift Virtualization Operator Deployment tab.
  5. Click the Options menu kebab in the row containing the kubevirt-hyperconverged custom resource. In the expanded menu, click Delete HyperConverged Cluster.
  6. Click Delete in the confirmation window.
  7. Navigate to the WorkloadsPods page to verify that only the Operator pods are running.
  8. Open a terminal window and clean up the remaining resources by running the following command:

    $ oc delete apiservices v1alpha3.subresources.kubevirt.io -n openshift-cnv

4.6.3. Deleting the OpenShift Virtualization catalog subscription

To finish uninstalling OpenShift Virtualization, delete the OpenShift Virtualization catalog subscription.

Prerequisites

  • An active subscription to the OpenShift Virtualization catalog

Procedure

  1. Navigate to the OperatorsOperatorHub page.
  2. Search for OpenShift Virtualization and then select it.
  3. Click Uninstall.
Note

You can now delete the openshift-cnv namespace.

4.6.4. Deleting a namespace using the web console

You can delete a namespace by using the OpenShift Container Platform web console.

Note

If you do not have permissions to delete the namespace, the Delete Namespace option is not available.

Procedure

  1. Navigate to AdministrationNamespaces.
  2. Locate the namespace that you want to delete in the list of namespaces.
  3. On the far right side of the namespace listing, select Delete Namespace from the Options menu kebab .
  4. When the Delete Namespace pane opens, enter the name of the namespace that you want to delete in the field.
  5. Click Delete.

4.7. Uninstalling OpenShift Virtualization using the CLI

You can uninstall OpenShift Virtualization by using the OpenShift Container Platform CLI.

4.7.1. Prerequisites

4.7.2. Deleting OpenShift Virtualization

You can delete OpenShift Virtualization by using the CLI.

Prerequisites

  • Install the OpenShift CLI (oc).
  • Access to a OpenShift Virtualization cluster using an account with cluster-admin permissions.
Note

When you delete the subscription of the OpenShift Virtualization operator in the OLM by using the CLI, the ClusterServiceVersion (CSV) object is not deleted from the cluster. To completely uninstall OpenShift Virtualization, you must explicitly delete the CSV.

Procedure

  1. Delete the HyperConverged custom resource:

    $ oc delete HyperConverged kubevirt-hyperconverged -n openshift-cnv
  2. Delete the subscription of the OpenShift Virtualization operator in the Operator Lifecycle Manager (OLM):

    $ oc delete subscription kubevirt-hyperconverged -n openshift-cnv
  3. Set the cluster service version (CSV) name for OpenShift Virtualization as an environment variable:

    $ CSV_NAME=$(oc get csv -n openshift-cnv -o=jsonpath="{.items[0].metadata.name}")
  4. Delete the CSV from the OpenShift Virtualization cluster by specifying the CSV name from the previous step:

    $ oc delete csv ${CSV_NAME} -n openshift-cnv

    OpenShift Virtualization is uninstalled when a confirmation message indicates that the CSV was deleted successfully:

    Example output

    clusterserviceversion.operators.coreos.com "kubevirt-hyperconverged-operator.v4.9.7" deleted

Chapter 5. Upgrading OpenShift Virtualization

Learn how Operator Lifecycle Manager (OLM) delivers z-stream and minor version updates for OpenShift Virtualization.

5.1. About upgrading OpenShift Virtualization

  • Operator Lifecycle Manager (OLM) manages the lifecycle of the OpenShift Virtualization Operator. The Marketplace Operator, which is deployed during OpenShift Container Platform installation, makes external Operators available to your cluster.
  • OLM provides z-stream and minor version updates for OpenShift Virtualization. Minor version updates become available when you upgrade OpenShift Container Platform to the next minor version. You cannot upgrade OpenShift Virtualization to the next minor version without first upgrading OpenShift Container Platform.
  • OpenShift Virtualization subscriptions use a single update channel that is named stable. The stable channel ensures that your OpenShift Virtualization and OpenShift Container Platform versions are compatible.
  • If your subscription’s approval strategy is set to Automatic, the upgrade process starts as soon as a new version of the Operator is available in the stable channel. It is highly recommended to use the Automatic approval strategy to maintain a supportable environment. Each minor version of OpenShift Virtualization is only supported if you run the corresponding OpenShift Container Platform version. For example, you must run OpenShift Virtualization 4.9 on OpenShift Container Platform 4.9.

    • Though it is possible to select the Manual approval strategy, this is not recommended because it risks the supportability and functionality of your cluster. With the Manual approval strategy, you must manually approve every pending update. If OpenShift Container Platform and OpenShift Virtualization updates are out of sync, your cluster becomes unsupported.
  • The amount of time an update takes to complete depends on your network connection. Most automatic updates complete within fifteen minutes.
  • Upgrading does not interrupt network connections.
  • Data volumes and their associated persistent volume claims are preserved during upgrade.
Important

If you have virtual machines running that cannot be live migrated, they might block an OpenShift Container Platform cluster upgrade. This includes virtual machines that use hostpath provisioner storage or SR-IOV network interfaces that have the sriovLiveMigration feature gate disabled.

As a workaround, you can reconfigure the virtual machines so that they can be powered off automatically during a cluster upgrade. Remove the evictionStrategy: LiveMigrate field and set the runStrategy field to Always.

5.2. Configuring automatic workload updates

Important

Automatically updating workloads is a Technology Preview feature only. Technology Preview features are not supported with Red Hat production service level agreements (SLAs) and might not be functionally complete. Red Hat does not recommend using them in production. These features provide early access to upcoming product features, enabling customers to test functionality and provide feedback during the development process.

For more information about the support scope of Red Hat Technology Preview features, see Technology Preview Features Support Scope.

5.2.1. Configuring workload update methods

You can configure workload update methods by editing the HyperConverged custom resource (CR).

Prerequisites

  • To use live migration as an update method, you must first enable live migration in the cluster.

    Note

    If a VirtualMachineInstance CR contains evictionStrategy: LiveMigrate and the virtual machine instance (VMI) does not support live migration, the VMI will not update.

Procedure

  1. To open the HyperConverged CR in your default editor, run the following command:

    $ oc edit hco -n openshift-cnv kubevirt-hyperconverged
  2. Edit the workloadUpdateStrategy stanza of the HyperConverged CR. For example:

    apiVersion: hco.kubevirt.io/v1beta1
    kind: HyperConverged
    metadata:
      name: kubevirt-hyperconverged
    spec:
      workloadUpdateStrategy:
        workloadUpdateMethods: 1
        - LiveMigrate 2
        - Evict 3
        batchEvictionSize: 10 4
        batchEvictionInterval: "1m0s" 5
    ...
    1
    The methods that can be used to perform automated workload updates. The available values are LiveMigrate and Evict. If you enable both options as shown in this example, updates use LiveMigrate for VMIs that support live migration and Evict for any VMIs that do not support live migration. To disable automatic workload updates, you can either remove the workloadUpdateStrategy stanza or set workloadUpdateMethods: [] to leave the array empty.
    2
    The least disruptive update method. VMIs that support live migration are updated by migrating the virtual machine (VM) guest into a new pod with the updated components enabled. If LiveMigrate is the only workload update method listed, VMIs that do not support live migration are not disrupted or updated.
    3
    A disruptive method that shuts down VMI pods during upgrade. Evict is the only update method available if live migration is not enabled in the cluster. If a VMI is controlled by a VirtualMachine object that has runStrategy: always configured, a new VMI is created in a new pod with updated components.
    4
    The number of VMIs that can be forced to be updated at a time by using the Evict method. This does not apply to the LiveMigrate method.
    5
    The interval to wait before evicting the next batch of workloads. This does not apply to the LiveMigrate method.
    Note

    You can configure live migration limits and timeouts by editing the spec.liveMigrationConfig stanza of the HyperConverged CR.

  3. To apply your changes, save and exit the editor.

5.3. Approving pending Operator upgrades

5.3.1. Manually approving a pending Operator update

If an installed Operator has the approval strategy in its subscription set to Manual, when new updates are released in its current update channel, the update must be manually approved before installation can begin.

Prerequisites

  • An Operator previously installed using Operator Lifecycle Manager (OLM).

Procedure

  1. In the Administrator perspective of the OpenShift Container Platform web console, navigate to Operators → Installed Operators.
  2. Operators that have a pending update display a status with Upgrade available. Click the name of the Operator you want to update.
  3. Click the Subscription tab. Any update requiring approval are displayed next to Upgrade Status. For example, it might display 1 requires approval.
  4. Click 1 requires approval, then click Preview Install Plan.
  5. Review the resources that are listed as available for update. When satisfied, click Approve.
  6. Navigate back to the Operators → Installed Operators page to monitor the progress of the update. When complete, the status changes to Succeeded and Up to date.

5.4. Monitoring upgrade status

5.4.1. Monitoring OpenShift Virtualization upgrade status

To monitor the status of a OpenShift Virtualization Operator upgrade, watch the cluster service version (CSV) PHASE. You can also monitor the CSV conditions in the web console or by running the command provided here.

Note

The PHASE and conditions values are approximations that are based on available information.

Prerequisites

  • Log in to the cluster as a user with the cluster-admin role.
  • Install the OpenShift CLI (oc).

Procedure

  1. Run the following command:

    $ oc get csv -n openshift-cnv
  2. Review the output, checking the PHASE field. For example:

    Example output

    VERSION  REPLACES                                        PHASE
    4.9.0    kubevirt-hyperconverged-operator.v4.8.2         Installing
    4.9.0    kubevirt-hyperconverged-operator.v4.9.0         Replacing

  3. Optional: Monitor the aggregated status of all OpenShift Virtualization component conditions by running the following command:

    $ oc get hco -n openshift-cnv kubevirt-hyperconverged \
    -o=jsonpath='{range .status.conditions[*]}{.type}{"\t"}{.status}{"\t"}{.message}{"\n"}{end}'

    A successful upgrade results in the following output:

    Example output

    ReconcileComplete  True  Reconcile completed successfully
    Available          True  Reconcile completed successfully
    Progressing        False Reconcile completed successfully
    Degraded           False Reconcile completed successfully
    Upgradeable        True  Reconcile completed successfully

5.4.2. Viewing outdated OpenShift Virtualization workloads

You can view a list of outdated workloads by using the CLI.

Note

If there are outdated virtualization pods in your cluster, the OutdatedVirtualMachineInstanceWorkloads alert fires.

Procedure

  • To view a list of outdated virtual machine instances (VMIs), run the following command:

    $ kubectl get vmi -l kubevirt.io/outdatedLauncherImage --all-namespaces

5.5. Additional resources

Chapter 6. Additional security privileges granted for kubevirt-controller and virt-launcher

The kubevirt-controller and virt-launcher pods are granted some SELinux policies and Security Context Constraints privileges that are in addition to typical pod owners. These privileges enable virtual machines to use OpenShift Virtualization features.

6.1. Extended SELinux policies for virt-launcher pods

The container_t SELinux policy for virt-launcher pods is extended with the following rules:

  • allow process self (tun_socket (relabelfrom relabelto attach_queue))
  • allow process sysfs_t (file (write))
  • allow process hugetlbfs_t (dir (add_name create write remove_name rmdir setattr))
  • allow process hugetlbfs_t (file (create unlink))

These rules enable the following virtualization features:

  • Relabel and attach queues to its own TUN sockets, which is required to support network multi-queue. Multi-queue enables network performance to scale as the number of available vCPUs increases.
  • Allows virt-launcher pods to write information to sysfs (/sys) files, which is required to enable Single Root I/O Virtualization (SR-IOV).
  • Read/write hugetlbfs entries, which is required to support huge pages. Huge pages are a method of managing large amounts of memory by increasing the memory page size.

6.2. Additional OpenShift Container Platform security context constraints and Linux capabilities for the kubevirt-controller service account

Security context constraints (SCCs) control permissions for pods. These permissions include actions that a pod, a collection of containers, can perform and what resources it can access. You can use SCCs to define a set of conditions that a pod must run with to be accepted into the system.

The kubevirt-controller is a cluster controller that creates the virt-launcher pods for virtual machines in the cluster. These virt-launcher pods are granted permissions by the kubevirt-controller service account.

6.2.1. Additional SCCs granted to the kubevirt-controller service account

The kubevirt-controller service account is granted additional SCCs and Linux capabilities so that it can create virt-launcher pods with the appropriate permissions. These extended permissions allow virtual machines to take advantage of OpenShift Virtualization features that are beyond the scope of typical pods.

The kubevirt-controller service account is granted the following SCCs:

  • scc.AllowHostDirVolumePlugin = true
    This allows virtual machines to use the hostpath volume plugin.
  • scc.AllowPrivilegedContainer = false
    This ensures the virt-launcher pod is not run as a privileged container.
  • scc.AllowedCapabilities = []corev1.Capability{"NET_ADMIN", "NET_RAW", "SYS_NICE"}
    This provides the following additional Linux capabilities NET_ADMIN, NET_RAW, and SYS_NICE.

6.2.2. Viewing the SCC and RBAC definitions for the kubevirt-controller

You can view the SecurityContextConstraints definition for the kubevirt-controller by using the oc tool:

$ oc get scc kubevirt-controller -o yaml

You can view the RBAC definition for the kubevirt-controller clusterrole by using the oc tool:

$ oc get clusterrole kubevirt-controller -o yaml

6.3. Additional resources

  • The Red Hat Enterprise Linux Virtualization Tuning and Optimization Guide has more information on network multi-queue and huge pages.
  • The capabilities man page has more information on the Linux capabilities.
  • The sysfs(5) man page has more information on sysfs.
  • The OpenShift Container Platform Authentication guide has more information on Security Context Constraints.

Chapter 7. Using the CLI tools

The two primary CLI tools used for managing resources in the cluster are:

  • The OpenShift Virtualization virtctl client
  • The OpenShift Container Platform oc client

7.1. Prerequisites

7.2. OpenShift Container Platform client commands

The OpenShift Container Platform oc client is a command-line utility for managing OpenShift Container Platform resources, including the VirtualMachine (vm) and VirtualMachineInstance (vmi) object types.

Note

You can use the -n <namespace> flag to specify a different project.

Table 7.1. oc commands
CommandDescription

oc login -u <user_name>

Log in to the OpenShift Container Platform cluster as <user_name>.

oc get <object_type>

Display a list of objects for the specified object type in the current project.

oc describe <object_type> <resource_name>

Display details of the specific resource in the current project.

oc create -f <object_config>

Create a resource in the current project from a file name or from stdin.

oc edit <object_type> <resource_name>

Edit a resource in the current project.

oc delete <object_type> <resource_name>

Delete a resource in the current project.

For more comprehensive information on oc client commands, see the OpenShift Container Platform CLI tools documentation.

7.3. Virtctl client commands

The virtctl client is a command-line utility for managing OpenShift Virtualization resources.

To view a list of virtctl commands, run the following command:

$ virtctl help

To view a list of options that you can use with a specific command, run it with the -h or --help flag. For example:

$ virtctl image-upload -h

To view a list of global command options that you can use with any virtctl command, run the following command:

$ virtctl options

The following table contains the virtctl commands used throughout the OpenShift Virtualization documentation.

Table 7.2. virtctl client commands
CommandDescription

virtctl start <vm_name>

Start a virtual machine.

virtctl start --paused <vm_name>

Start a virtual machine in a paused state. This option enables you to interrupt the boot process from the VNC console.

virtctl stop <vm_name>

Stop a virtual machine.

virtctl stop <vm_name> --grace-period 0 --force

Force stop a virtual machine. This option might cause data inconsistency or data loss.

virtctl pause vm|vmi <object_name>

Pause a virtual machine or virtual machine instance. The machine state is kept in memory.

virtctl unpause vm|vmi <object_name>

Unpause a virtual machine or virtual machine instance.

virtctl migrate <vm_name>

Migrate a virtual machine.

virtctl restart <vm_name>

Restart a virtual machine.

virtctl expose <vm_name>

Create a service that forwards a designated port of a virtual machine or virtual machine instance and expose the service on the specified port of the node.

virtctl console <vmi_name>

Connect to a serial console of a virtual machine instance.

virtctl vnc --kubeconfig=$KUBECONFIG <vmi_name>

Open a VNC (Virtual Network Client) connection to a virtual machine instance. Access the graphical console of a virtual machine instance through a VNC which requires a remote viewer on your local machine.

virtctl vnc --kubeconfig=$KUBECONFIG --proxy-only=true <vmi-name>

Display the port number and connect manually to the virtual machine instance by using any viewer through the VNC connection.

virtctl vnc --kubeconfig=$KUBECONFIG --port=<port-number> <vmi-name>

Specify a port number to run the proxy on the specified port, if that port is available. If a port number is not specified, the proxy runs on a random port.

virtctl image-upload dv <datavolume_name> --image-path=</path/to/image> --no-create

Upload a virtual machine image to a data volume that already exists.

virtctl image-upload dv <datavolume_name> --size=<datavolume_size> --image-path=</path/to/image>

Upload a virtual machine image to a new data volume.

virtctl version

Display the client and server version information.

virtctl fslist <vmi_name>

Return a full list of file systems available on the guest machine.

virtctl guestosinfo <vmi_name>

Return guest agent information about the operating system.

virtctl userlist <vmi_name>

Return a full list of logged-in users on the guest machine.

7.4. Creating a container using virtctl guestfs

You can use the virtctl guestfs command to deploy an interactive container with libguestfs-tools and a persistent volume claim (PVC) attached to it.

Procedure

  • To deploy a container with libguestfs-tools, mount the PVC, and attach a shell to it, run the following command:

    $ virtctl guestfs -n <namespace> <pvc_name> 1
    1
    The PVC name is a required argument. If you do not include it, an error message appears.

7.5. Libguestfs tools and virtctl guestfs

Libguestfs tools help you access and modify virtual machine (VM) disk images. You can use libguestfs tools to view and edit files in a guest, clone and build virtual machines, and format and resize disks.

You can also use the virtctl guestfs command and its sub-commands to modify, inspect, and debug VM disks on a PVC. To see a complete list of possible sub-commands, enter virt- on the command line and press the Tab key. For example:

CommandDescription

virt-edit -a /dev/vda /etc/motd

Edit a file interactively in your terminal.

virt-customize -a /dev/vda --ssh-inject root:string:<public key example>

Inject an ssh key into the guest and create a login.

virt-df -a /dev/vda -h

See how much disk space is used by a VM.

virt-customize -a /dev/vda --run-command 'rpm -qa > /rpm-list'

See the full list of all RPMs installed on a guest by creating an output file containing the full list.

virt-cat -a /dev/vda /rpm-list

Display the output file list of all RPMs created using the virt-customize -a /dev/vda --run-command 'rpm -qa > /rpm-list' command in your terminal.

virt-sysprep -a /dev/vda

Seal a virtual machine disk image to be used as a template.

By default, virtctl guestfs creates a session with everything needed to manage a VM disk. However, the command also supports several flag options if you want to customize the behavior:

Flag OptionDescription

--h or --help

Provides help for guestfs.

-n <namespace> option with a <pvc_name> argument

To use a PVC from a specific namespace.

If you do not use the -n <namespace> option, your current project is used. To change projects, use oc project <namespace>.

If you do not include a <pvc_name> argument, an error message appears.

--image string

Lists the libguestfs-tools container image.

You can configure the container to use a custom image by using the --image option.

--kvm

Indicates that kvm is used by the libguestfs-tools container.

By default, virtctl guestfs sets up kvm for the interactive container, which greatly speeds up the libguest-tools execution because it uses QEMU.

If a cluster does not have any kvm supporting nodes, you must disable kvm by setting the option --kvm=false.

If not set, the libguestfs-tools pod remains pending because it cannot be scheduled on any node.

--pull-policy string

Shows the pull policy for the libguestfs image.

You can also overwrite the image’s pull policy by setting the pull-policy option.

The command also checks if a PVC is in use by another pod, in which case an error message appears. However, once the libguestfs-tools process starts, the setup cannot avoid a new pod using the same PVC. You must verify that there are no active virtctl guestfs pods before starting the VM that accesses the same PVC.

Note

The virtctl guestfs command accepts only a single PVC attached to the interactive pod.

7.6. Additional resources

Chapter 8. Virtual machines

8.1. Creating virtual machines

Use one of these procedures to create a virtual machine:

  • Quick Start guided tour
  • Running the wizard
  • Pasting a pre-configured YAML file with the virtual machine wizard
  • Using the CLI
Warning

Do not create virtual machines in openshift-* namespaces. Instead, create a new namespace or use an existing namespace without the openshift prefix.

When you create virtual machines from the web console, select a virtual machine template that is configured with a boot source. Virtual machine templates with a boot source are labeled as Available boot source or they display a customized label text. Using templates with an available boot source expedites the process of creating virtual machines.

Templates without a boot source are labeled as Boot source required. You can use these templates if you complete the steps for adding a boot source to the virtual machine.

8.1.1. Using a Quick Start to create a virtual machine

The web console provides Quick Starts with instructional guided tours for creating virtual machines. You can access the Quick Starts catalog by selecting the Help menu in the Administrator perspective to view the Quick Starts catalog. When you click on a Quick Start tile and begin the tour, the system guides you through the process.

Tasks in a Quick Start begin with selecting a Red Hat template. Then, you can add a boot source and import the operating system image. Finally, you can save the custom template and use it to create a virtual machine.

Prerequisites

  • Access to the website where you can download the URL link for the operating system image.

Procedure

  1. In the web console, select Quick Starts from the Help menu.
  2. Click on a tile in the Quick Starts catalog. For example: Creating a Red Hat Linux Enterprise Linux virtual machine.
  3. Follow the instructions in the guided tour and complete the tasks for importing an operating system image and creating a virtual machine. The Virtual Machines tab displays the virtual machine.

8.1.2. Running the virtual machine wizard to create a virtual machine

The web console features a wizard that guides you through the process of selecting a virtual machine template and creating a virtual machine. Red Hat virtual machine templates are preconfigured with an operating system image, default settings for the operating system, flavor (CPU and memory), and workload type (server). When templates are configured with a boot source, they are labeled with a customized label text or the default label text Available boot source. These templates are then ready to be used for creating virtual machines.

You can select a template from the list of preconfigured templates, review the settings, and create a virtual machine in the Create virtual machine from template wizard. If you choose to customize your virtual machine, the wizard guides you through the General, Networking, Storage, Advanced, and Review steps. All required fields displayed by the wizard are marked by a *.

Create network interface controllers (NICs) and storage disks later and attach them to virtual machines.

Procedure

  1. Click WorkloadsVirtualization from the side menu.
  2. From the Virtual Machines tab or the Templates tab, click Create and select Virtual Machine with Wizard.
  3. Select a template that is configured with a boot source.
  4. Click Next to go to the Review and create step.
  5. Clear the Start this virtual machine after creation checkbox if you do not want to start the virtual machine now.
  6. Click Create virtual machine and exit the wizard or continue with the wizard to customize the virtual machine.
  7. Click Customize virtual machine to go to the General step.

    1. Optional: Edit the Name field to specify a custom name for the virtual machine.
    2. Optional: In the Description field, add a description.
  8. Click Next to go to the Networking step. A nic0 NIC is attached by default.

    1. Optional: Click Add Network Interface to create additional NICs.
    2. Optional: You can remove any or all NICs by clicking the Options menu kebab and selecting Delete. A virtual machine does not need a NIC attached to be created. You can create NICs after the virtual machine has been created.
  9. Click Next to go to the Storage step.

    1. Optional: Click Add Disk to create additional disks. These disks can be removed by clicking the Options menu kebab and selecting Delete.
    2. Optional: Click the Options menu kebab to edit the disk and save your changes.
  10. Click Next to go to the Advanced step and choose one of the following options:

    1. If you selected a Linux template to create the VM, review the details for Cloud-init and configure SSH access.

      Note

      Statically inject an SSH key by using the custom script in cloud-init or in the wizard. This allows you to securely and remotely manage virtual machines and manage and transfer information. This step is strongly recommended to secure your VM. 

    2. If you selected a Windows template to create the VM, use the SysPrep section to upload answer files in XML format for automated Windows setup.
  11. Click Next to go to the Review step and review the settings for the virtual machine.
  12. Click Create Virtual Machine.
  13. Click See virtual machine details to view the Overview for this virtual machine.

    The virtual machine is listed in the Virtual Machines tab.

Refer to the virtual machine wizard fields section when running the web console wizard.

8.1.2.1. Virtual machine wizard fields
NameParameterDescription

Name

 

The name can contain lowercase letters (a-z), numbers (0-9), and hyphens (-), up to a maximum of 253 characters. The first and last characters must be alphanumeric. The name must not contain uppercase letters, spaces, periods (.), or special characters.

Description

 

Optional description field.

Operating System

 

The operating system that is selected for the virtual machine in the template. You cannot edit this field when creating a virtual machine from a template.

Boot Source

Import via URL (creates PVC)

Import content from an image available from an HTTP or HTTPS endpoint. Example: Obtaining a URL link from the web page with the operating system image.

Clone existing PVC (creates PVC)

Select an existent persistent volume claim available on the cluster and clone it.

Import via Registry (creates PVC)

Provision virtual machine from a bootable operating system container located in a registry accessible from the cluster. Example: kubevirt/cirros-registry-disk-demo.

PXE (network boot - adds network interface)

Boot an operating system from a server on the network. Requires a PXE bootable network attachment definition.

Persistent Volume Claim project

 

Project name that you want to use for cloning the PVC.

Persistent Volume Claim name

 

PVC name that should apply to this virtual machine template if you are cloning an existing PVC.

Mount this as a CD-ROM boot source

 

A CD-ROM requires an additional disk for installing the operating system. Select the checkbox to add a disk and customize it later.

Flavor

Tiny, Small, Medium, Large, Custom

Presets the amount of CPU and memory in a virtual machine template with predefined values that are allocated to the virtual machine, depending on the operating system associated with that template.

If you choose a default template, you can override the cpus and memsize values in the template using custom values to create a custom template. Alternatively, you can create a custom template by modifying the cpus and memsize values in the Details tab on the WorkloadsVirtualization page.

Workload Type

Note

If you choose the incorrect Workload Type, there could be performance or resource utilization issues (such as a slow UI).

Desktop

A virtual machine configuration for use on a desktop. Ideal for consumption on a small scale. Recommended for use with the web console. Use this template class or the Server template class to prioritize VM density over guaranteed VM performance.

Server

Balances performance and it is compatible with a wide range of server workloads. Use this template class or the Desktop template class to prioritize VM density over guaranteed VM performance.

High-Performance (requires CPU Manager)

A virtual machine configuration that is optimized for high-performance workloads. Use this template class to prioritize guaranteed VM performance over VM density.

Start this virtual machine after creation.

 

This checkbox is selected by default and the virtual machine starts running after creation. Clear the checkbox if you do not want the virtual machine to start when it is created.

Enable the CPU Manager to use the high-performance workload profile.

8.1.2.2. Networking fields
NameDescription

Name

Name for the network interface controller.

Model

Indicates the model of the network interface controller. Supported values are e1000e and virtio.

Network

List of available network attachment definitions.

Type

List of available binding methods. For the default pod network, masquerade is the only recommended binding method. For secondary networks, use the bridge binding method. The masquerade method is not supported for non-default networks. Select SR-IOV if you configured an SR-IOV network device and defined that network in the namespace.

MAC Address

MAC address for the network interface controller. If a MAC address is not specified, one is assigned automatically.

8.1.2.3. Storage fields
NameSelectionDescription

Source

Blank (creates PVC)

Create an empty disk.

Import via URL (creates PVC)

Import content via URL (HTTP or HTTPS endpoint).

Use an existing PVC

Use a PVC that is already available in the cluster.

Clone existing PVC (creates PVC)

Select an existing PVC available in the cluster and clone it.

Import via Registry (creates PVC)

Import content via container registry.

Container (ephemeral)

Upload content from a container located in a registry accessible from the cluster. The container disk should be used only for read-only filesystems such as CD-ROMs or temporary virtual machines.

Name

 

Name of the disk. The name can contain lowercase letters (a-z), numbers (0-9), hyphens (-), and periods (.), up to a maximum of 253 characters. The first and last characters must be alphanumeric. The name must not contain uppercase letters, spaces, or special characters.

Size

 

Size of the disk in GiB.

Type

 

Type of disk. Example: Disk or CD-ROM

Interface

 

Type of disk device. Supported interfaces are virtIO, SATA, and SCSI.

Storage Class

 

The storage class that is used to create the disk.

Advanced storage settings

The following advanced storage settings are optional and available for Blank, Import via URL, and Clone existing PVC disks. Before OpenShift Virtualization 4.11, if you do not specify these parameters, the system uses the default values from the kubevirt-storage-class-defaults config map. In OpenShift Virtualization 4.11 and later, the system uses the default values from the storage profile.

Note

Use storage profiles to ensure consistent advanced storage settings when provisioning storage for OpenShift Virtualization.

To manually specify Volume Mode and Access Mode, you must clear the Apply optimized StorageProfile settings checkbox, which is selected by default.

NameMode descriptionParameterParameter description

Volume Mode

Defines whether the persistent volume uses a formatted file system or raw block state. Default is Filesystem.

Filesystem

Stores the virtual disk on a file system-based volume.

Block

Stores the virtual disk directly on the block volume. Only use Block if the underlying storage supports it.

Access Mode

Access mode of the persistent volume.

ReadWriteOnce (RWO)

Volume can be mounted as read-write by a single node.

ReadWriteMany (RWX)

Volume can be mounted as read-write by many nodes at one time.

Note

This is required for some features, such as live migration of virtual machines between nodes.

ReadOnlyMany (ROX)

Volume can be mounted as read only by many nodes.

8.1.2.4. Cloud-init fields
NameDescription

Hostname

Sets a specific hostname for the virtual machine.

Authorized SSH Keys

The user’s public key that is copied to ~/.ssh/authorized_keys on the virtual machine.

Custom script

Replaces other options with a field in which you paste a custom cloud-init script.

To configure storage class defaults, use storage profiles. For more information, see Customizing the storage profile.

8.1.2.5. Pasting in a pre-configured YAML file to create a virtual machine

Create a virtual machine by writing or pasting a YAML configuration file. A valid example virtual machine configuration is provided by default whenever you open the YAML edit screen.

If your YAML configuration is invalid when you click Create, an error message indicates the parameter in which the error occurs. Only one error is shown at a time.

Note

Navigating away from the YAML screen while editing cancels any changes to the configuration you have made.

Procedure

  1. Click WorkloadsVirtualization from the side menu.
  2. Click the Virtual Machines tab.
  3. Click Create and select Virtual Machine With YAML.
  4. Write or paste your virtual machine configuration in the editable window.

    1. Alternatively, use the example virtual machine provided by default in the YAML screen.
  5. Optional: Click Download to download the YAML configuration file in its present state.
  6. Click Create to create the virtual machine.

The virtual machine is listed in the Virtual Machines tab.

8.1.3. Using the CLI to create a virtual machine

You can create a virtual machine from a virtualMachine manifest.

Procedure

  1. Edit the VirtualMachine manifest for your VM. For example, the following manifest configures a Red Hat Enterprise Linux (RHEL) VM:

    Example 8.1. Example manifest for a RHEL VM

    apiVersion: kubevirt.io/v1
    kind: VirtualMachine
    metadata:
      labels:
        app: <vm_name> 1
      name: <vm_name>
    spec:
      dataVolumeTemplates:
      - apiVersion: cdi.kubevirt.io/v1beta1
        kind: DataVolume
        metadata:
          name: <vm_name>
        spec:
          sourceRef:
            kind: DataSource
            name: rhel9
            namespace: openshift-virtualization-os-images
          storage:
            resources:
              requests:
                storage: 30Gi
      running: false
      template:
        metadata:
          labels:
            kubevirt.io/domain: <vm_name>
        spec:
          domain:
            cpu:
              cores: 1
              sockets: 2
              threads: 1
            devices:
              disks:
              - disk:
                  bus: virtio
                name: rootdisk
              - disk:
                  bus: virtio
                name: cloudinitdisk
              interfaces:
              - masquerade: {}
                name: default
              rng: {}
            features:
              smm:
                enabled: true
            firmware:
              bootloader:
                efi: {}
            resources:
              requests:
                memory: 8Gi
          evictionStrategy: LiveMigrate
          networks:
          - name: default
            pod: {}
          volumes:
          - dataVolume:
              name: <vm_name>
            name: rootdisk
          - cloudInitNoCloud:
              userData: |-
                #cloud-config
                user: cloud-user
                password: '<password>' 2
                chpasswd: { expire: False }
            name: cloudinitdisk
    1
    Specify the name of the virtual machine.
    2
    Specify the password for cloud-user.
  2. Create a virtual machine by using the manifest file:

    $ oc create -f <vm_manifest_file>.yaml
  3. Optional: Start the virtual machine:

    $ virtctl start <vm_name>

8.1.4. Virtual machine storage volume types

Storage volume typeDescription

ephemeral

A local copy-on-write (COW) image that uses a network volume as a read-only backing store. The backing volume must be a PersistentVolumeClaim. The ephemeral image is created when the virtual machine starts and stores all writes locally. The ephemeral image is discarded when the virtual machine is stopped, restarted, or deleted. The backing volume (PVC) is not mutated in any way.

persistentVolumeClaim

Attaches an available PV to a virtual machine. Attaching a PV allows for the virtual machine data to persist between sessions.

Importing an existing virtual machine disk into a PVC by using CDI and attaching the PVC to a virtual machine instance is the recommended method for importing existing virtual machines into OpenShift Container Platform. There are some requirements for the disk to be used within a PVC.

dataVolume

Data volumes build on the persistentVolumeClaim disk type by managing the process of preparing the virtual machine disk via an import, clone, or upload operation. VMs that use this volume type are guaranteed not to start until the volume is ready.

Specify type: dataVolume or type: "". If you specify any other value for type, such as persistentVolumeClaim, a warning is displayed, and the virtual machine does not start.

cloudInitNoCloud

Attaches a disk that contains the referenced cloud-init NoCloud data source, providing user data and metadata to the virtual machine. A cloud-init installation is required inside the virtual machine disk.

containerDisk

References an image, such as a virtual machine disk, that is stored in the container image registry. The image is pulled from the registry and attached to the virtual machine as a disk when the virtual machine is launched.

A containerDisk volume is not limited to a single virtual machine and is useful for creating large numbers of virtual machine clones that do not require persistent storage.

Only RAW and QCOW2 formats are supported disk types for the container image registry. QCOW2 is recommended for reduced image size.

Note

A containerDisk volume is ephemeral. It is discarded when the virtual machine is stopped, restarted, or deleted. A containerDisk volume is useful for read-only file systems such as CD-ROMs or for disposable virtual machines.

emptyDisk

Creates an additional sparse QCOW2 disk that is tied to the life-cycle of the virtual machine interface. The data survives guest-initiated reboots in the virtual machine but is discarded when the virtual machine stops or is restarted from the web console. The empty disk is used to store application dependencies and data that otherwise exceeds the limited temporary file system of an ephemeral disk.

The disk capacity size must also be provided.

8.1.5. About RunStrategies for virtual machines

A RunStrategy for virtual machines determines a virtual machine instance’s (VMI) behavior, depending on a series of conditions. The spec.runStrategy setting exists in the virtual machine configuration process as an alternative to the spec.running setting. The spec.runStrategy setting allows greater flexibility for how VMIs are created and managed, in contrast to the spec.running setting with only true or false responses. However, the two settings are mutually exclusive. Only either spec.running or spec.runStrategy can be used. An error occurs if both are used.

There are four defined RunStrategies.

Always
A VMI is always present when a virtual machine is created. A new VMI is created if the original stops for any reason, which is the same behavior as spec.running: true.
RerunOnFailure
A VMI is re-created if the previous instance fails due to an error. The instance is not re-created if the virtual machine stops successfully, such as when it shuts down.
Manual
The start, stop, and restart virtctl client commands can be used to control the VMI’s state and existence.
Halted
No VMI is present when a virtual machine is created, which is the same behavior as spec.running: false.

Different combinations of the start, stop and restart virtctl commands affect which RunStrategy is used.

The following table follows a VM’s transition from different states. The first column shows the VM’s initial RunStrategy. Each additional column shows a virtctl command and the new RunStrategy after that command is run.

Initial RunStrategystartstoprestart

Always

-

Halted

Always

RerunOnFailure

-

Halted

RerunOnFailure

Manual

Manual

Manual

Manual

Halted

Always

-

-

Note

In OpenShift Virtualization clusters installed using installer-provisioned infrastructure, when a node fails the MachineHealthCheck and becomes unavailable to the cluster, VMs with a RunStrategy of Always or RerunOnFailure are rescheduled on a new node.

apiVersion: kubevirt.io/v1
kind: VirtualMachine
spec:
  RunStrategy: Always 1
  template:
...
1
The VMI’s current RunStrategy setting.

8.1.6. Additional resources

8.2. Editing virtual machines

You can update a virtual machine configuration using either the YAML editor in the web console or the OpenShift CLI on the command line. You can also update a subset of the parameters in the Virtual Machine Details screen.

8.2.1. Editing a virtual machine in the web console

Edit select values of a virtual machine in the web console by clicking the pencil icon next to the relevant field. Other values can be edited using the CLI.

Labels and annotations are editable for both preconfigured Red Hat templates and your custom virtual machine templates. All other values are editable only for custom virtual machine templates that users have created using the Red Hat templates or the Create Virtual Machine Template wizard.

Procedure

  1. Click WorkloadsVirtualization from the side menu.
  2. Click the Virtual Machines tab.
  3. Select a virtual machine.
  4. Click the Details tab.
  5. Click the pencil icon to make a field editable.
  6. Make the relevant changes and click Save.
Note

If the virtual machine is running, changes to Boot Order or Flavor will not take effect until you restart the virtual machine.

You can view pending changes by clicking View Pending Changes on the right side of the relevant field. The Pending Changes banner at the top of the page displays a list of all changes that will be applied when the virtual machine restarts.

8.2.2. Editing a virtual machine YAML configuration using the web console

You can edit the YAML configuration of a virtual machine in the web console. Some parameters cannot be modified. If you click Save with an invalid configuration, an error message indicates the parameter that cannot be changed.

If you edit the YAML configuration while the virtual machine is running, changes will not take effect until you restart the virtual machine.

Note

Navigating away from the YAML screen while editing cancels any changes to the configuration you have made.

Procedure

  1. Click WorkloadsVirtualization from the side menu.
  2. Select a virtual machine.
  3. Click the YAML tab to display the editable configuration.
  4. Optional: You can click Download to download the YAML file locally in its current state.
  5. Edit the file and click Save.

A confirmation message shows that the modification has been successful and includes the updated version number for the object.

8.2.3. Editing a virtual machine YAML configuration using the CLI

Use this procedure to edit a virtual machine YAML configuration using the CLI.

Prerequisites

  • You configured a virtual machine with a YAML object configuration file.
  • You installed the oc CLI.

Procedure

  1. Run the following command to update the virtual machine configuration:

    $ oc edit <object_type> <object_ID>
  2. Open the object configuration.
  3. Edit the YAML.
  4. If you edit a running virtual machine, you need to do one of the following:

    • Restart the virtual machine.
    • Run the following command for the new configuration to take effect:

      $ oc apply <object_type> <object_ID>

8.2.4. Adding a virtual disk to a virtual machine

Use this procedure to add a virtual disk to a virtual machine.

Procedure

  1. Click WorkloadsVirtualization from the side menu.
  2. Click the Virtual Machines tab.
  3. Select a virtual machine to open the Virtual Machine Overview screen.
  4. Click the Disks tab.
  5. In the Add Disk window, specify the Source, Name, Size, Type, Interface, and Storage Class.

    1. Advanced: You can enable preallocation if you use a blank disk source and require maximum write performance when creating data volumes. To do so, select the Enable preallocation checkbox.
    2. Optional: In the Advanced list, specify the Volume Mode and Access Mode for the virtual disk. If you do not specify these parameters, the system uses the default values from the kubevirt-storage-class-defaults config map.
  6. Click Add.
Note

If the virtual machine is running, the new disk is in the pending restart state and will not be attached until you restart the virtual machine.

The Pending Changes banner at the top of the page displays a list of all changes that will be applied when the virtual machine restarts.

To configure storage class defaults, use storage profiles. For more information, see Customizing the storage profile.

8.2.4.1. Storage fields
NameSelectionDescription

Source

Blank (creates PVC)

Create an empty disk.

Import via URL (creates PVC)

Import content via URL (HTTP or HTTPS endpoint).

Use an existing PVC

Use a PVC that is already available in the cluster.

Clone existing PVC (creates PVC)

Select an existing PVC available in the cluster and clone it.

Import via Registry (creates PVC)

Import content via container registry.

Container (ephemeral)

Upload content from a container located in a registry accessible from the cluster. The container disk should be used only for read-only filesystems such as CD-ROMs or temporary virtual machines.

Name

 

Name of the disk. The name can contain lowercase letters (a-z), numbers (0-9), hyphens (-), and periods (.), up to a maximum of 253 characters. The first and last characters must be alphanumeric. The name must not contain uppercase letters, spaces, or special characters.

Size

 

Size of the disk in GiB.

Type

 

Type of disk. Example: Disk or CD-ROM

Interface

 

Type of disk device. Supported interfaces are virtIO, SATA, and SCSI.

Storage Class

 

The storage class that is used to create the disk.

Advanced storage settings

The following advanced storage settings are optional and available for Blank, Import via URL, and Clone existing PVC disks. Before OpenShift Virtualization 4.11, if you do not specify these parameters, the system uses the default values from the kubevirt-storage-class-defaults config map. In OpenShift Virtualization 4.11 and later, the system uses the default values from the storage profile.

Note

Use storage profiles to ensure consistent advanced storage settings when provisioning storage for OpenShift Virtualization.

To manually specify Volume Mode and Access Mode, you must clear the Apply optimized StorageProfile settings checkbox, which is selected by default.

NameMode descriptionParameterParameter description

Volume Mode

Defines whether the persistent volume uses a formatted file system or raw block state. Default is Filesystem.

Filesystem

Stores the virtual disk on a file system-based volume.

Block

Stores the virtual disk directly on the block volume. Only use Block if the underlying storage supports it.

Access Mode

Access mode of the persistent volume.

ReadWriteOnce (RWO)

Volume can be mounted as read-write by a single node.

ReadWriteMany (RWX)

Volume can be mounted as read-write by many nodes at one time.

Note

This is required for some features, such as live migration of virtual machines between nodes.

ReadOnlyMany (ROX)

Volume can be mounted as read only by many nodes.

8.2.5. Adding a network interface to a virtual machine

Use this procedure to add a network interface to a virtual machine.

Procedure

  1. Click WorkloadsVirtualization from the side menu.
  2. Click the Virtual Machines tab.
  3. Select a virtual machine to open the Virtual Machine Overview screen.
  4. Click the Network Interfaces tab.
  5. Click Add Network Interface.
  6. In the Add Network Interface window, specify the Name, Model, Network, Type, and MAC Address of the network interface.
  7. Click Add.
Note

If the virtual machine is running, the new network interface is in the pending restart state and changes will not take effect until you restart the virtual machine.

The Pending Changes banner at the top of the page displays a list of all changes that will be applied when the virtual machine restarts.

8.2.5.1. Networking fields
NameDescription

Name

Name for the network interface controller.

Model

Indicates the model of the network interface controller. Supported values are e1000e and virtio.

Network

List of available network attachment definitions.

Type

List of available binding methods. For the default pod network, masquerade is the only recommended binding method. For secondary networks, use the bridge binding method. The masquerade method is not supported for non-default networks. Select SR-IOV if you configured an SR-IOV network device and defined that network in the namespace.

MAC Address

MAC address for the network interface controller. If a MAC address is not specified, one is assigned automatically.

8.2.6. Editing CD-ROMs for Virtual Machines

Use the following procedure to edit CD-ROMs for virtual machines.

Procedure

  1. Click WorkloadsVirtualization from the side menu.
  2. Click the Virtual Machines tab.
  3. Select a virtual machine to open the Virtual Machine Overview screen.
  4. Click the Disks tab.
  5. Click the Options menu kebab for the CD-ROM that you want to edit and select Edit.
  6. In the Edit CD-ROM window, edit the fields: Source, Persistent Volume Claim, Name, Type, and Interface.
  7. Click Save.

8.2.7. Additional resources

8.3. Editing boot order

You can update the values for a boot order list by using the web console or the CLI.

With Boot Order in the Virtual Machine Overview page, you can:

  • Select a disk or network interface controller (NIC) and add it to the boot order list.
  • Edit the order of the disks or NICs in the boot order list.
  • Remove a disk or NIC from the boot order list, and return it back to the inventory of bootable sources.

8.3.1. Adding items to a boot order list in the web console

Add items to a boot order list by using the web console.

Procedure

  1. Click WorkloadsVirtualization from the side menu.
  2. Click the Virtual Machines tab.
  3. Select a virtual machine to open the Virtual Machine Overview screen.
  4. Click the Details tab.
  5. Click the pencil icon that is located on the right side of Boot Order. If a YAML configuration does not exist, or if this is the first time that you are creating a boot order list, the following message displays: No resource selected. VM will attempt to boot from disks by order of appearance in YAML file.
  6. Click Add Source and select a bootable disk or network interface controller (NIC) for the virtual machine.
  7. Add any additional disks or NICs to the boot order list.
  8. Click Save.
Note

If the virtual machine is running, changes to Boot Order will not take effect until you restart the virtual machine.

You can view pending changes by clicking View Pending Changes on the right side of the Boot Order field. The Pending Changes banner at the top of the page displays a list of all changes that will be applied when the virtual machine restarts.

8.3.2. Editing a boot order list in the web console

Edit the boot order list in the web console.

Procedure

  1. Click WorkloadsVirtualization from the side menu.
  2. Click the Virtual Machines tab.
  3. Select a virtual machine to open the Virtual Machine Overview screen.
  4. Click the Details tab.
  5. Click the pencil icon that is located on the right side of Boot Order.
  6. Choose the appropriate method to move the item in the boot order list:

    • If you do not use a screen reader, hover over the arrow icon next to the item that you want to move, drag the item up or down, and drop it in a location of your choice.
    • If you use a screen reader, press the Up Arrow key or Down Arrow key to move the item in the boot order list. Then, press the Tab key to drop the item in a location of your choice.
  7. Click Save.
Note

If the virtual machine is running, changes to the boot order list will not take effect until you restart the virtual machine.

You can view pending changes by clicking View Pending Changes on the right side of the Boot Order field. The Pending Changes banner at the top of the page displays a list of all changes that will be applied when the virtual machine restarts.

8.3.3. Editing a boot order list in the YAML configuration file

Edit the boot order list in a YAML configuration file by using the CLI.

Procedure

  1. Open the YAML configuration file for the virtual machine by running the following command:

    $ oc edit vm example
  2. Edit the YAML file and modify the values for the boot order associated with a disk or network interface controller (NIC). For example:

    disks:
      - bootOrder: 1 1
        disk:
          bus: virtio
        name: containerdisk
      - disk:
          bus: virtio
        name: cloudinitdisk
      - cdrom:
          bus: virtio
        name: cd-drive-1
    interfaces:
      - boot Order: 2 2
        macAddress: '02:96:c4:00:00'
        masquerade: {}
        name: default
    1
    The boot order value specified for the disk.
    2
    The boot order value specified for the network interface controller.
  3. Save the YAML file.
  4. Click reload the content to apply the updated boot order values from the YAML file to the boot order list in the web console.

8.3.4. Removing items from a boot order list in the web console

Remove items from a boot order list by using the web console.

Procedure

  1. Click WorkloadsVirtualization from the side menu.
  2. Click the Virtual Machines tab.
  3. Select a virtual machine to open the Virtual Machine Overview screen.
  4. Click the Details tab.
  5. Click the pencil icon that is located on the right side of Boot Order.
  6. Click the Remove icon delete next to the item. The item is removed from the boot order list and saved in the list of available boot sources. If you remove all items from the boot order list, the following message displays: No resource selected. VM will attempt to boot from disks by order of appearance in YAML file.
Note

If the virtual machine is running, changes to Boot Order will not take effect until you restart the virtual machine.

You can view pending changes by clicking View Pending Changes on the right side of the Boot Order field. The Pending Changes banner at the top of the page displays a list of all changes that will be applied when the virtual machine restarts.

8.4. Deleting virtual machines

You can delete a virtual machine from the web console or by using the oc command line interface.

8.4.1. Deleting a virtual machine using the web console

Deleting a virtual machine permanently removes it from the cluster.

Note

When you delete a virtual machine, the data volume it uses is automatically deleted.

Procedure

  1. In the OpenShift Virtualization console, click WorkloadsVirtualization from the side menu.
  2. Click the Virtual Machines tab.
  3. Click the Options menu kebab of the virtual machine that you want to delete and select Delete Virtual Machine.

    • Alternatively, click the virtual machine name to open the Virtual Machine Overview screen and click ActionsDelete Virtual Machine.
  4. In the confirmation pop-up window, click Delete to permanently delete the virtual machine.

8.4.2. Deleting a virtual machine by using the CLI

You can delete a virtual machine by using the oc command line interface (CLI). The oc client enables you to perform actions on multiple virtual machines.

Note

When you delete a virtual machine, the data volume it uses is automatically deleted.

Prerequisites

  • Identify the name of the virtual machine that you want to delete.

Procedure

  • Delete the virtual machine by running the following command:

    $ oc delete vm <vm_name>
    Note

    This command only deletes objects that exist in the current project. Specify the -n <project_name> option if the object you want to delete is in a different project or namespace.

8.5. Managing virtual machine instances

If you have standalone virtual machine instances (VMIs) that were created independently outside of the OpenShift Virtualization environment, you can manage them by using the web console or by using oc or virtctl commands from the command-line interface (CLI).

The virtctl command provides more virtualization options than the oc command. For example, you can use virtctl to pause a VM or expose a port.

8.5.1. About virtual machine instances

A virtual machine instance (VMI) is a representation of a running virtual machine (VM). When a VMI is owned by a VM or by another object, you manage it through its owner in the web console or by using the oc command-line interface (CLI).

A standalone VMI is created and started independently with a script, through automation, or by using other methods in the CLI. In your environment, you might have standalone VMIs that were developed and started outside of the OpenShift Virtualization environment. You can continue to manage those standalone VMIs by using the CLI. You can also use the web console for specific tasks associated with standalone VMIs:

  • List standalone VMIs and their details.
  • Edit labels and annotations for a standalone VMI.
  • Delete a standalone VMI.

When you delete a VM, the associated VMI is automatically deleted. You delete a standalone VMI directly because it is not owned by VMs or other objects.

Note

Before you uninstall OpenShift Virtualization, list and view the standalone VMIs by using the CLI or the web console. Then, delete any outstanding VMIs.

8.5.2. Listing all virtual machine instances using the CLI

You can list all virtual machine instances (VMIs) in your cluster, including standalone VMIs and those owned by virtual machines, by using the oc command-line interface (CLI).

Procedure

  • List all VMIs by running the following command:

    $ oc get vmis

8.5.3. Listing standalone virtual machine instances using the web console

Using the web console, you can list and view standalone virtual machine instances (VMIs) in your cluster that are not owned by virtual machines (VMs).

Note

VMIs that are owned by VMs or other objects are not displayed in the web console. The web console displays only standalone VMIs. If you want to list all VMIs in your cluster, you must use the CLI.

Procedure

  • Click Workloads → Virtualization from the side menu. A list of VMs and standalone VMIs displays. You can identify standalone VMIs by the dark colored badges that display next to the virtual machine instance names.

8.5.4. Editing a standalone virtual machine instance using the web console

You can edit annotations and labels for a standalone virtual machine instance (VMI) using the web console. Other items displayed in the Details page for a standalone VMI are not editable.

Procedure

  1. Click WorkloadsVirtualization from the side menu. A list of virtual machines (VMs) and standalone VMIs displays.
  2. Click the name of a standalone VMI to open the Virtual Machine Instance Overview screen.
  3. Click the Details tab.
  4. Click the pencil icon that is located on the right side of Annotations.
  5. Make the relevant changes and click Save.
Note

To edit labels for a standalone VMI, click Actions and select Edit Labels. Make the relevant changes and click Save.

8.5.5. Deleting a standalone virtual machine instance using the CLI

You can delete a standalone virtual machine instance (VMI) by using the oc command-line interface (CLI).

Prerequisites

  • Identify the name of the VMI that you want to delete.

Procedure

  • Delete the VMI by running the following command:

    $ oc delete vmi <vmi_name>

8.5.6. Deleting a standalone virtual machine instance using the web console

Delete a standalone virtual machine instance (VMI) from the web console.

Procedure

  1. In the OpenShift Container Platform web console, click WorkloadsVirtualization from the side menu.
  2. Click the ⋮ button of the standalone virtual machine instance (VMI) that you want to delete and select Delete Virtual Machine Instance.

    • Alternatively, click the name of the standalone VMI. The Virtual Machine Instance Overview page displays.
  3. Select ActionsDelete Virtual Machine Instance.
  4. In the confirmation pop-up window, click Delete to permanently delete the standalone VMI.

8.6. Controlling virtual machine states

You can stop, start, restart, and unpause virtual machines from the web console.

You can use virtctl to manage virtual machine states and perform other actions from the CLI. For example, you can use virtctl to force stop a VM or expose a port.

8.6.1. Starting a virtual machine

You can start a virtual machine from the web console.

Procedure

  1. Click WorkloadsVirtualization from the side menu.
  2. Click the Virtual Machines tab.
  3. Find the row that contains the virtual machine that you want to start.
  4. Navigate to the appropriate menu for your use case:

    • To stay on this page, where you can perform actions on multiple virtual machines:

      1. Click the Options menu kebab located at the far right end of the row.
    • To view comprehensive information about the selected virtual machine before you start it:

      1. Access the Virtual Machine Overview screen by clicking the name of the virtual machine.
      2. Click Actions.
  5. Select Start Virtual Machine.
  6. In the confirmation window, click Start to start the virtual machine.
Note

When you start virtual machine that is provisioned from a URL source for the first time, the virtual machine has a status of Importing while OpenShift Virtualization imports the container from the URL endpoint. Depending on the size of the image, this process might take several minutes.

8.6.2. Restarting a virtual machine

You can restart a running virtual machine from the web console.

Important

To avoid errors, do not restart a virtual machine while it has a status of Importing.

Procedure

  1. Click WorkloadsVirtualization from the side menu.
  2. Click the Virtual Machines tab.
  3. Find the row that contains the virtual machine that you want to restart.
  4. Navigate to the appropriate menu for your use case:

    • To stay on this page, where you can perform actions on multiple virtual machines:

      1. Click the Options menu kebab located at the far right end of the row.
    • To view comprehensive information about the selected virtual machine before you restart it:

      1. Access the Virtual Machine Overview screen by clicking the name of the virtual machine.
      2. Click Actions.
  5. Select Restart Virtual Machine.
  6. In the confirmation window, click Restart to restart the virtual machine.

8.6.3. Stopping a virtual machine

You can stop a virtual machine from the web console.

Procedure

  1. Click WorkloadsVirtualization from the side menu.
  2. Click the Virtual Machines tab.
  3. Find the row that contains the virtual machine that you want to stop.
  4. Navigate to the appropriate menu for your use case:

    • To stay on this page, where you can perform actions on multiple virtual machines:

      1. Click the Options menu kebab located at the far right end of the row.
    • To view comprehensive information about the selected virtual machine before you stop it:

      1. Access the Virtual Machine Overview screen by clicking the name of the virtual machine.
      2. Click Actions.
  5. Select Stop Virtual Machine.
  6. In the confirmation window, click Stop to stop the virtual machine.

8.6.4. Unpausing a virtual machine

You can unpause a paused virtual machine from the web console.

Prerequisites

  • At least one of your virtual machines must have a status of Paused.

    Note

    You can pause virtual machines by using the virtctl client.

Procedure

  1. Click WorkloadsVirtualization from the side menu.
  2. Click the Virtual Machines tab.
  3. Find the row that contains the virtual machine that you want to unpause.
  4. Navigate to the appropriate menu for your use case:

    • To stay on this page, where you can perform actions on multiple virtual machines:

      1. In the Status column, click Paused.
    • To view comprehensive information about the selected virtual machine before you unpause it:

      1. Access the Virtual Machine Overview screen by clicking the name of the virtual machine.
      2. Click the pencil icon that is located on the right side of Status.
  5. In the confirmation window, click Unpause to unpause the virtual machine.

8.7. Accessing virtual machine consoles

OpenShift Virtualization provides different virtual machine consoles that you can use to accomplish different product tasks. You can access these consoles through the OpenShift Container Platform web console and by using CLI commands.

8.7.1. Accessing virtual machine consoles in the OpenShift Container Platform web console

You can connect to virtual machines by using the serial console or the VNC console in the OpenShift Container Platform web console.

You can connect to Windows virtual machines by using the desktop viewer console, which uses RDP (remote desktop protocol), in the OpenShift Container Platform web console.

8.7.1.1. Connecting to the serial console

Connect to the serial console of a running virtual machine from the Console tab in the Virtual Machine Overview screen of the web console.

Procedure

  1. In the OpenShift Virtualization console, click WorkloadsVirtualization from the side menu.
  2. Click the Virtual Machines tab.
  3. Select a virtual machine to open the Virtual Machine Overview page.
  4. Click Console. The VNC console opens by default.
  5. Select Disconnect before switching to ensure that only one console session is open at a time. Otherwise, the VNC console session remains active in the background.
  6. Click the VNC Console drop-down list and select Serial Console.
  7. Click Disconnect to end the console session.
  8. Optional: Open the serial console in a separate window by clicking Open Console in New Window.
8.7.1.2. Connecting to the VNC console

Connect to the VNC console of a running virtual machine from the Console tab in the Virtual Machine Overview screen of the web console.

Procedure

  1. In the OpenShift Virtualization console, click WorkloadsVirtualization from the side menu.
  2. Click the Virtual Machines tab.
  3. Select a virtual machine to open the Virtual Machine Overview page.
  4. Click the Console tab. The VNC console opens by default.
  5. Optional: Open the VNC console in a separate window by clicking Open Console in New Window.
  6. Optional: Send key combinations to the virtual machine by clicking Send Key.
  7. Click outside the console window and then click Disconnect to end the session.
8.7.1.3. Connecting to a Windows virtual machine with RDP

The desktop viewer console, which utilizes the Remote Desktop Protocol (RDP), provides a better console experience for connecting to Windows virtual machines.

To connect to a Windows virtual machine with RDP, download the console.rdp file for the virtual machine from the Consoles tab in the Virtual Machine Details screen of the web console and supply it to your preferred RDP client.

Prerequisites

  • A running Windows virtual machine with the QEMU guest agent installed. The qemu-guest-agent is included in the VirtIO drivers.
  • A layer-2 NIC attached to the virtual machine.
  • An RDP client installed on a machine on the same network as the Windows virtual machine.

Procedure

  1. In the OpenShift Virtualization console, click WorkloadsVirtualization from the side menu.
  2. Click the Virtual Machines tab.
  3. Select a Windows virtual machine to open the Virtual Machine Overview screen.
  4. Click the Console tab.
  5. In the Console list, select Desktop Viewer.
  6. In the Network Interface list, select the layer-2 NIC.
  7. Click Launch Remote Desktop to download the console.rdp file.
  8. Open an RDP client and reference the console.rdp file. For example, using remmina:

    $ remmina --connect /path/to/console.rdp
  9. Enter the Administrator user name and password to connect to the Windows virtual machine.
8.7.1.4. Copying the SSH command from the web console

Copy the command to access a running virtual machine (VM) via SSH from the Actions list in the web console.

Procedure

  1. In the OpenShift Container Platform console, click WorkloadsVirtualization from the side menu.
  2. Click the Virtual Machines tab.
  3. Select a virtual machine to open the Virtual Machine Overview page.
  4. From the Actions list, select Copy SSH Command. You can now paste this command onto the OpenShift CLI (oc).

8.7.2. Accessing virtual machine consoles by using CLI commands

8.7.2.1. Accessing a virtual machine instance via SSH

You can use SSH to access a virtual machine (VM) after you expose port 22 on it.

The virtctl expose command forwards a virtual machine instance (VMI) port to a node port and creates a service for enabled access. The following example creates the fedora-vm-ssh service that forwards traffic from a specific port of cluster nodes to port 22 of the <fedora-vm> virtual machine.

Prerequisites

  • You must be in the same project as the VMI.
  • The VMI you want to access must be connected to the default pod network by using the masquerade binding method.
  • The VMI you want to access must be running.
  • Install the OpenShift CLI (oc).

Procedure

  1. Run the following command to create the fedora-vm-ssh service:

    $ virtctl expose vm <fedora-vm> --port=22 --name=fedora-vm-ssh --type=NodePort 1
    1
    <fedora-vm> is the name of the VM that you run the fedora-vm-ssh service on.
  2. Check the service to find out which port the service acquired:

    $ oc get svc

    Example output

    NAME            TYPE       CLUSTER-IP     EXTERNAL-IP   PORT(S)           AGE
    fedora-vm-ssh   NodePort   127.0.0.1      <none>        22:32551/TCP   6s

    In this example, the service acquired the 32551 port.

  3. Log in to the VMI via SSH. Use the ipAddress of any of the cluster nodes and the port that you found in the previous step:

    $ ssh username@<node_IP_address> -p 32551
8.7.2.2. Accessing a virtual machine via SSH with YAML configurations

You can enable an SSH connection to a virtual machine (VM) without the need to run the virtctl expose command. When the YAML file for the VM and the YAML file for the service are configured and applied, the service forwards the SSH traffic to the VM.

The following examples show the configurations for the VM’s YAML file and the service YAML file.

Prerequisites

  • Install the OpenShift CLI (oc).
  • Create a namespace for the VM’s YAML file by using the oc create namespace command and specifying a name for the namespace.

Procedure

  1. In the YAML file for the VM, add the label and a value for exposing the service for SSH connections. Enable the masquerade feature for the interface:

    Example VirtualMachine definition

    apiVersion: kubevirt.io/v1
    kind: VirtualMachine
    metadata:
      namespace: ssh-ns 1
      name: vm-ssh
    spec:
      running: false
      template:
        metadata:
          labels:
            kubevirt.io/vm: vm-ssh
            special: vm-ssh 2
        spec:
          domain:
            devices:
              disks:
              - disk:
                  bus: virtio
                name: containerdisk
              - disk:
                  bus: virtio
                name: cloudinitdisk
              interfaces:
              - masquerade: {} 3
                name: testmasquerade 4
              rng: {}
            machine:
              type: ""
            resources:
              requests:
                memory: 1024M
          networks:
          - name: testmasquerade
            pod: {}
          volumes:
          - name: containerdisk
            containerDisk:
              image: kubevirt/fedora-cloud-container-disk-demo
          - name: cloudinitdisk
            cloudInitNoCloud:
              userData: |
                #cloud-config
                user: fedora
                password: fedora
                chpasswd: {expire: False}
    # ...

    1
    Name of the namespace created by the oc create namespace command.
    2
    Label used by the service to identify the virtual machine instances that are enabled for SSH traffic connections. The label can be any key:value pair that is added as a label to this YAML file and as a selector in the service YAML file.
    3
    The interface type is masquerade.
    4
    The name of this interface is testmasquerade.
  2. Create the VM:

    $ oc create -f <path_for_the_VM_YAML_file>
  3. Start the VM:

    $ virtctl start vm-ssh
  4. In the YAML file for the service, specify the service name, port number, and the target port.

    Example Service definition

    apiVersion: v1
    kind: Service
    metadata:
      name: svc-ssh 1
      namespace: ssh-ns 2
    spec:
      ports:
      - targetPort: 22 3
        protocol: TCP
        port: 27017
      selector:
        special: vm-ssh 4
      type: NodePort
    # ...

    1
    Name of the SSH service.
    2
    Name of the namespace created by the oc create namespace command.
    3
    The target port number for the SSH connection.
    4
    The selector name and value must match the label specified in the YAML file for the VM.
  5. Create the service:

    $ oc create -f <path_for_the_service_YAML_file>
  6. Verify that the VM is running:

    $ oc get vmi

    Example output

    NAME    AGE     PHASE       IP              NODENAME
    vm-ssh 6s       Running     10.244.196.152  node01

  7. Check the service to find out which port the service acquired:

    $ oc get svc

    Example output

    NAME            TYPE       CLUSTER-IP     EXTERNAL-IP   PORT(S)           AGE
    svc-ssh     NodePort       10.106.236.208 <none>        27017:30093/TCP   22s

    In this example, the service acquired the port number 30093.

  8. Run the following command to obtain the IP address for the node:

    $ oc get node <node_name> -o wide

    Example output

    NAME    STATUS   ROLES   AGE    VERSION  INTERNAL-IP      EXTERNAL-IP
    node01  Ready    worker  6d22h  v1.22.1  192.168.55.101   <none>

  9. Log in to the VM via SSH by specifying the IP address of the node where the VM is running and the port number. Use the port number displayed by the oc get svc command and the IP address of the node displayed by the oc get node command. The following example shows the ssh command with the username, node’s IP address, and the port number:

    $ ssh fedora@192.168.55.101 -p 30093
8.7.2.3. Accessing the serial console of a virtual machine instance

The virtctl console command opens a serial console to the specified virtual machine instance.

Prerequisites

  • The virt-viewer package must be installed.
  • The virtual machine instance you want to access must be running.

Procedure

  • Connect to the serial console with virtctl:

    $ virtctl console <VMI>
8.7.2.4. Accessing the graphical console of a virtual machine instances with VNC

The virtctl client utility can use the remote-viewer function to open a graphical console to a running virtual machine instance. This capability is included in the virt-viewer package.

Prerequisites

  • The virt-viewer package must be installed.
  • The virtual machine instance you want to access must be running.
Note

If you use virtctl via SSH on a remote machine, you must forward the X session to your machine.

Procedure

  1. Connect to the graphical interface with the virtctl utility:

    $ virtctl vnc <VMI>
  2. If the command failed, try using the -v flag to collect troubleshooting information:

    $ virtctl vnc <VMI> -v 4
8.7.2.5. Connecting to a Windows virtual machine with an RDP console

The Remote Desktop Protocol (RDP) provides a better console experience for connecting to Windows virtual machines.

To connect to a Windows virtual machine with RDP, specify the IP address of the attached L2 NIC to your RDP client.

Prerequisites

  • A running Windows virtual machine with the QEMU guest agent installed. The qemu-guest-agent is included in the VirtIO drivers.
  • A layer 2 NIC attached to the virtual machine.
  • An RDP client installed on a machine on the same network as the Windows virtual machine.

Procedure

  1. Log in to the OpenShift Virtualization cluster through the oc CLI tool as a user with an access token.

    $ oc login -u <user> https://<cluster.example.com>:8443
  2. Use oc describe vmi to display the configuration of the running Windows virtual machine.

    $ oc describe vmi <windows-vmi-name>

    Example output

    ...
    spec:
      networks:
      - name: default
        pod: {}
      - multus:
          networkName: cnv-bridge
        name: bridge-net
    ...
    status:
      interfaces:
      - interfaceName: eth0
        ipAddress: 198.51.100.0/24
        ipAddresses:
          198.51.100.0/24
        mac: a0:36:9f:0f:b1:70
        name: default
      - interfaceName: eth1
        ipAddress: 192.0.2.0/24
        ipAddresses:
          192.0.2.0/24
          2001:db8::/32
        mac: 00:17:a4:77:77:25
        name: bridge-net
    ...

  3. Identify and copy the IP address of the layer 2 network interface. This is 192.0.2.0 in the above example, or 2001:db8:: if you prefer IPv6.
  4. Open an RDP client and use the IP address copied in the previous step for the connection.
  5. Enter the Administrator user name and password to connect to the Windows virtual machine.

8.8. Triggering virtual machine failover by resolving a failed node

If a node fails and machine health checks are not deployed on your cluster, virtual machines (VMs) with RunStrategy: Always configured are not automatically relocated to healthy nodes. To trigger VM failover, you must manually delete the Node object.

Note

If you installed your cluster by using installer-provisioned infrastructure and you properly configured machine health checks:

  • Failed nodes are automatically recycled.
  • Virtual machines with RunStrategy set to Always or RerunOnFailure are automatically scheduled on healthy nodes.

8.8.1. Prerequisites

  • A node where a virtual machine was running has the NotReady condition.
  • The virtual machine that was running on the failed node has RunStrategy set to Always.
  • You have installed the OpenShift CLI (oc).

8.8.2. Deleting nodes from a bare metal cluster

When you delete a node using the CLI, the node object is deleted in Kubernetes, but the pods that exist on the node are not deleted. Any bare pods not backed by a replication controller become inaccessible to OpenShift Container Platform. Pods backed by replication controllers are rescheduled to other available nodes. You must delete local manifest pods.

Procedure

Delete a node from an OpenShift Container Platform cluster running on bare metal by completing the following steps:

  1. Mark the node as unschedulable:

    $ oc adm cordon <node_name>
  2. Drain all pods on the node:

    $ oc adm drain <node_name> --force=true

    This step might fail if the node is offline or unresponsive. Even if the node does not respond, it might still be running a workload that writes to shared storage. To avoid data corruption, power down the physical hardware before you proceed.

  3. Delete the node from the cluster:

    $ oc delete node <node_name>

    Although the node object is now deleted from the cluster, it can still rejoin the cluster after reboot or if the kubelet service is restarted. To permanently delete the node and all its data, you must decommission the node.

  4. If you powered down the physical hardware, turn it back on so that the node can rejoin the cluster.

8.8.3. Verifying virtual machine failover

After all resources are terminated on the unhealthy node, a new virtual machine instance (VMI) is automatically created on a healthy node for each relocated VM. To confirm that the VMI was created, view all VMIs by using the oc CLI.

8.8.3.1. Listing all virtual machine instances using the CLI

You can list all virtual machine instances (VMIs) in your cluster, including standalone VMIs and those owned by virtual machines, by using the oc command-line interface (CLI).

Procedure

  • List all VMIs by running the following command:

    $ oc get vmis

8.9. Installing the QEMU guest agent on virtual machines

The QEMU guest agent is a daemon that runs on the virtual machine and passes information to the host about the virtual machine, users, file systems, and secondary networks.

8.9.1. Installing QEMU guest agent on a Linux virtual machine

The qemu-guest-agent is widely available and available by default in Red Hat virtual machines. Install the agent and start the service.

To check if your virtual machine (VM) has the QEMU guest agent installed and running, verify that AgentConnected is listed in the VM spec.

Note

To create snapshots of an online (Running state) VM with the highest integrity, install the QEMU guest agent.

The QEMU guest agent takes a consistent snapshot by attempting to quiesce the VM’s file system as much as possible, depending on the system workload. This ensures that in-flight I/O is written to the disk before the snapshot is taken. If the guest agent is not present, quiescing is not possible and a best-effort snapshot is taken. The conditions under which the snapshot was taken are reflected in the snapshot indications that are displayed in the web console or CLI.

Procedure

  1. Access the virtual machine command line through one of the consoles or by SSH.
  2. Install the QEMU guest agent on the virtual machine:

    $ yum install -y qemu-guest-agent
  3. Ensure the service is persistent and start it:

    $ systemctl enable --now qemu-guest-agent

You can also install and start the QEMU guest agent by using the custom script field in the cloud-init section of the wizard when creating either virtual machines or virtual machines templates in the web console.

8.9.2. Installing QEMU guest agent on a Windows virtual machine

For Windows virtual machines, the QEMU guest agent is included in the VirtIO drivers. Install the drivers on an existng or new Windows system.

To check if your virtual machine (VM) has the QEMU guest agent installed and running, verify that AgentConnected is listed in the VM spec.

Note

To create snapshots of an online (Running state) VM with the highest integrity, install the QEMU guest agent.

The QEMU guest agent takes a consistent snapshot by attempting to quiesce the VM’s file system as much as possible, depending on the system workload. This ensures that in-flight I/O is written to the disk before the snapshot is taken. If the guest agent is not present, quiescing is not possible and a best-effort snapshot is taken. The conditions under which the snapshot was taken are reflected in the snapshot indications that are displayed in the web console or CLI.

8.9.2.1. Installing VirtIO drivers on an existing Windows virtual machine

Install the VirtIO drivers from the attached SATA CD drive to an existing Windows virtual machine.

Note

This procedure uses a generic approach to adding drivers to Windows. The process might differ slightly between versions of Windows. See the installation documentation for your version of Windows for specific installation steps.

Procedure

  1. Start the virtual machine and connect to a graphical console.
  2. Log in to a Windows user session.
  3. Open Device Manager and expand Other devices to list any Unknown device.

    1. Open the Device Properties to identify the unknown device. Right-click the device and select Properties.
    2. Click the Details tab and select Hardware Ids in the Property list.
    3. Compare the Value for the Hardware Ids with the supported VirtIO drivers.
  4. Right-click the device and select Update Driver Software.
  5. Click Browse my computer for driver software and browse to the attached SATA CD drive, where the VirtIO drivers are located. The drivers are arranged hierarchically according to their driver type, operating system, and CPU architecture.
  6. Click Next to install the driver.
  7. Repeat this process for all the necessary VirtIO drivers.
  8. After the driver installs, click Close to close the window.
  9. Reboot the virtual machine to complete the driver installation.
8.9.2.2. Installing VirtIO drivers during Windows installation

Install the VirtIO drivers from the attached SATA CD driver during Windows installation.

Note

This procedure uses a generic approach to the Windows installation and the installation method might differ between versions of Windows. See the documentation for the version of Windows that you are installing.

Procedure

  1. Start the virtual machine and connect to a graphical console.
  2. Begin the Windows installation process.
  3. Select the Advanced installation.
  4. The storage destination will not be recognized until the driver is loaded. Click Load driver.
  5. The drivers are attached as a SATA CD drive. Click OK and browse the CD drive for the storage driver to load. The drivers are arranged hierarchically according to their driver type, operating system, and CPU architecture.
  6. Repeat the previous two steps for all required drivers.
  7. Complete the Windows installation.

8.10. Viewing the QEMU guest agent information for virtual machines

When the QEMU guest agent runs on the virtual machine, you can use the web console to view information about the virtual machine, users, file systems, and secondary networks.

8.10.1. Prerequisites

8.10.2. About the QEMU guest agent information in the web console

When the QEMU guest agent is installed, the Details pane within the Virtual Machine Overview tab and the Details tab display information about the hostname, operating system, time zone, and logged in users.

The Virtual Machine Overview shows information about the guest operating system installed on the virtual machine. The Details tab displays a table with information for logged in users. The Disks tab displays a table with information for file systems.

Note

If the QEMU guest agent is not installed, the Virtual Machine Overview tab and the Details tab display information about the operating system that was specified when the virtual machine was created.

8.10.3. Viewing the QEMU guest agent information in the web console

You can use the web console to view information for virtual machines that is passed by the QEMU guest agent to the host.

Procedure

  1. Click WorkloadsVirtual Machines from the side menu.
  2. Click the Virtual Machines tab.
  3. Select a virtual machine name to open the Virtual Machine Overview screen and view the Details pane.
  4. Click Logged in users to view the Details tab that shows information for users.
  5. Click the Disks tab to view information about the file systems.

8.11. Managing config maps, secrets, and service accounts in virtual machines

You can use secrets, config maps, and service accounts to pass configuration data to virtual machines. For example, you can:

  • Give a virtual machine access to a service that requires credentials by adding a secret to the virtual machine.
  • Store non-confidential configuration data in a config map so that a pod or another object can consume the data.
  • Allow a component to access the API server by associating a service account with that component.
Note

OpenShift Virtualization exposes secrets, config maps, and service accounts as virtual machine disks so that you can use them across platforms without additional overhead.

8.11.1. Adding a secret, config map, or service account to a virtual machine

Add a secret, config map, or service account to a virtual machine by using the OpenShift Container Platform web console.

Prerequisites

  • The secret, config map, or service account that you want to add must exist in the same namespace as the target virtual machine.

Procedure

  1. Click WorkloadsVirtualization from the side menu.
  2. Click the Virtual Machines tab.
  3. Select a virtual machine to open the Virtual Machine Overview screen.
  4. Click the Environment tab.
  5. Click Select a resource and select a secret, config map, or service account from the list. A six character serial number is automatically generated for the selected resource.
  6. Click Save.
  7. Optional. Add another object by clicking Add Config Map, Secret or Service Account.
Note
  1. You can reset the form to the last saved state by clicking Reload.
  2. The Environment resources are added to the virtual machine as disks. You can mount the secret, config map, or service account as you would mount any other disk.
  3. If the virtual machine is running, changes will not take effect until you restart the virtual machine. The newly added resources are marked as pending changes for both the Environment and Disks tab in the Pending Changes banner at the top of the page.

Verification

  1. From the Virtual Machine Overview page, click the Disks tab.
  2. Check to ensure that the secret, config map, or service account is included in the list of disks.
  3. Optional. Choose the appropriate method to apply your changes:

    1. If the virtual machine is running, restart the virtual machine by clicking ActionsRestart Virtual Machine.
    2. If the virtual machine is stopped, start the virtual machine by clicking ActionsStart Virtual Machine.

You can now mount the secret, config map, or service account as you would mount any other disk.

8.11.2. Removing a secret, config map, or service account from a virtual machine

Remove a secret, config map, or service account from a virtual machine by using the OpenShift Container Platform web console.

Prerequisites

  • You must have at least one secret, config map, or service account that is attached to a virtual machine.

Procedure

  1. Click WorkloadsVirtualization from the side menu.
  2. Click the Virtual Machines tab.
  3. Select a virtual machine to open the Virtual Machine Overview screen.
  4. Click the Environment tab.
  5. Find the item that you want to delete in the list, and click Remove delete on the right side of the item.
  6. Click Save.
Note

You can reset the form to the last saved state by clicking Reload.

Verification

  1. From the Virtual Machine Overview page, click the Disks tab.
  2. Check to ensure that the secret, config map, or service account that you removed is no longer included in the list of disks.

8.11.3. Additional resources

8.12. Installing VirtIO driver on an existing Windows virtual machine

8.12.1. About VirtIO drivers

VirtIO drivers are paravirtualized device drivers required for Microsoft Windows virtual machines to run in OpenShift Virtualization. The supported drivers are available in the container-native-virtualization/virtio-win container disk of the Red Hat Ecosystem Catalog.

The container-native-virtualization/virtio-win container disk must be attached to the virtual machine as a SATA CD drive to enable driver installation. You can install VirtIO drivers during Windows installation on the virtual machine or added to an existing Windows installation.

After the drivers are installed, the container-native-virtualization/virtio-win container disk can be removed from the virtual machine.

See also: Installing Virtio drivers on a new Windows virtual machine.

8.12.2. Supported VirtIO drivers for Microsoft Windows virtual machines

Table 8.1. Supported drivers
Driver nameHardware IDDescription

viostor

VEN_1AF4&DEV_1001
VEN_1AF4&DEV_1042

The block driver. Sometimes displays as an SCSI Controller in the Other devices group.

viorng

VEN_1AF4&DEV_1005
VEN_1AF4&DEV_1044

The entropy source driver. Sometimes displays as a PCI Device in the Other devices group.

NetKVM

VEN_1AF4&DEV_1000
VEN_1AF4&DEV_1041

The network driver. Sometimes displays as an Ethernet Controller in the Other devices group. Available only if a VirtIO NIC is configured.

8.12.3. Adding VirtIO drivers container disk to a virtual machine

OpenShift Virtualization distributes VirtIO drivers for Microsoft Windows as a container disk, which is available from the Red Hat Ecosystem Catalog. To install these drivers to a Windows virtual machine, attach the container-native-virtualization/virtio-win container disk to the virtual machine as a SATA CD drive in the virtual machine configuration file.

Prerequisites

  • Download the container-native-virtualization/virtio-win container disk from the Red Hat Ecosystem Catalog. This is not mandatory, because the container disk will be downloaded from the Red Hat registry if it not already present in the cluster, but it can reduce installation time.

Procedure

  1. Add the container-native-virtualization/virtio-win container disk as a cdrom disk in the Windows virtual machine configuration file. The container disk will be downloaded from the registry if it is not already present in the cluster.

    spec:
      domain:
        devices:
          disks:
            - name: virtiocontainerdisk
              bootOrder: 2 1
              cdrom:
                bus: sata
    volumes:
      - containerDisk:
          image: container-native-virtualization/virtio-win
        name: virtiocontainerdisk
    1
    OpenShift Virtualization boots virtual machine disks in the order defined in the VirtualMachine configuration file. You can either define other disks for the virtual machine before the container-native-virtualization/virtio-win container disk or use the optional bootOrder parameter to ensure the virtual machine boots from the correct disk. If you specify the bootOrder for a disk, it must be specified for all disks in the configuration.
  2. The disk is available once the virtual machine has started:

    • If you add the container disk to a running virtual machine, use oc apply -f <vm.yaml> in the CLI or reboot the virtual machine for the changes to take effect.
    • If the virtual machine is not running, use virtctl start <vm>.

After the virtual machine has started, the VirtIO drivers can be installed from the attached SATA CD drive.

8.12.4. Installing VirtIO drivers on an existing Windows virtual machine

Install the VirtIO drivers from the attached SATA CD drive to an existing Windows virtual machine.

Note

This procedure uses a generic approach to adding drivers to Windows. The process might differ slightly between versions of Windows. See the installation documentation for your version of Windows for specific installation steps.

Procedure

  1. Start the virtual machine and connect to a graphical console.
  2. Log in to a Windows user session.
  3. Open Device Manager and expand Other devices to list any Unknown device.

    1. Open the Device Properties to identify the unknown device. Right-click the device and select Properties.
    2. Click the Details tab and select Hardware Ids in the Property list.
    3. Compare the Value for the Hardware Ids with the supported VirtIO drivers.
  4. Right-click the device and select Update Driver Software.
  5. Click Browse my computer for driver software and browse to the attached SATA CD drive, where the VirtIO drivers are located. The drivers are arranged hierarchically according to their driver type, operating system, and CPU architecture.
  6. Click Next to install the driver.
  7. Repeat this process for all the necessary VirtIO drivers.
  8. After the driver installs, click Close to close the window.
  9. Reboot the virtual machine to complete the driver installation.

8.12.5. Removing the VirtIO container disk from a virtual machine

After installing all required VirtIO drivers to the virtual machine, the container-native-virtualization/virtio-win container disk no longer needs to be attached to the virtual machine. Remove the container-native-virtualization/virtio-win container disk from the virtual machine configuration file.

Procedure

  1. Edit the configuration file and remove the disk and the volume.

    $ oc edit vm <vm-name>
    spec:
      domain:
        devices:
          disks:
            - name: virtiocontainerdisk
              bootOrder: 2
              cdrom:
                bus: sata
    volumes:
      - containerDisk:
          image: container-native-virtualization/virtio-win
        name: virtiocontainerdisk
  2. Reboot the virtual machine for the changes to take effect.

8.13. Installing VirtIO driver on a new Windows virtual machine

8.13.1. Prerequisites

8.13.2. About VirtIO drivers

VirtIO drivers are paravirtualized device drivers required for Microsoft Windows virtual machines to run in OpenShift Virtualization. The supported drivers are available in the container-native-virtualization/virtio-win container disk of the Red Hat Ecosystem Catalog.

The container-native-virtualization/virtio-win container disk must be attached to the virtual machine as a SATA CD drive to enable driver installation. You can install VirtIO drivers during Windows installation on the virtual machine or added to an existing Windows installation.

After the drivers are installed, the container-native-virtualization/virtio-win container disk can be removed from the virtual machine.

See also: Installing VirtIO driver on an existing Windows virtual machine.

8.13.3. Supported VirtIO drivers for Microsoft Windows virtual machines

Table 8.2. Supported drivers
Driver nameHardware IDDescription

viostor

VEN_1AF4&DEV_1001
VEN_1AF4&DEV_1042

The block driver. Sometimes displays as an SCSI Controller in the Other devices group.

viorng

VEN_1AF4&DEV_1005
VEN_1AF4&DEV_1044

The entropy source driver. Sometimes displays as a PCI Device in the Other devices group.

NetKVM

VEN_1AF4&DEV_1000
VEN_1AF4&DEV_1041

The network driver. Sometimes displays as an Ethernet Controller in the Other devices group. Available only if a VirtIO NIC is configured.

8.13.4. Adding VirtIO drivers container disk to a virtual machine

OpenShift Virtualization distributes VirtIO drivers for Microsoft Windows as a container disk, which is available from the Red Hat Ecosystem Catalog. To install these drivers to a Windows virtual machine, attach the container-native-virtualization/virtio-win container disk to the virtual machine as a SATA CD drive in the virtual machine configuration file.

Prerequisites

  • Download the container-native-virtualization/virtio-win container disk from the Red Hat Ecosystem Catalog. This is not mandatory, because the container disk will be downloaded from the Red Hat registry if it not already present in the cluster, but it can reduce installation time.

Procedure

  1. Add the container-native-virtualization/virtio-win container disk as a cdrom disk in the Windows virtual machine configuration file. The container disk will be downloaded from the registry if it is not already present in the cluster.

    spec:
      domain:
        devices:
          disks:
            - name: virtiocontainerdisk
              bootOrder: 2 1
              cdrom:
                bus: sata
    volumes:
      - containerDisk:
          image: container-native-virtualization/virtio-win
        name: virtiocontainerdisk
    1
    OpenShift Virtualization boots virtual machine disks in the order defined in the VirtualMachine configuration file. You can either define other disks for the virtual machine before the container-native-virtualization/virtio-win container disk or use the optional bootOrder parameter to ensure the virtual machine boots from the correct disk. If you specify the bootOrder for a disk, it must be specified for all disks in the configuration.
  2. The disk is available once the virtual machine has started:

    • If you add the container disk to a running virtual machine, use oc apply -f <vm.yaml> in the CLI or reboot the virtual machine for the changes to take effect.
    • If the virtual machine is not running, use virtctl start <vm>.

After the virtual machine has started, the VirtIO drivers can be installed from the attached SATA CD drive.

8.13.5. Installing VirtIO drivers during Windows installation

Install the VirtIO drivers from the attached SATA CD driver during Windows installation.

Note

This procedure uses a generic approach to the Windows installation and the installation method might differ between versions of Windows. See the documentation for the version of Windows that you are installing.

Procedure

  1. Start the virtual machine and connect to a graphical console.
  2. Begin the Windows installation process.
  3. Select the Advanced installation.
  4. The storage destination will not be recognized until the driver is loaded. Click Load driver.
  5. The drivers are attached as a SATA CD drive. Click OK and browse the CD drive for the storage driver to load. The drivers are arranged hierarchically according to their driver type, operating system, and CPU architecture.
  6. Repeat the previous two steps for all required drivers.
  7. Complete the Windows installation.

8.13.6. Removing the VirtIO container disk from a virtual machine

After installing all required VirtIO drivers to the virtual machine, the container-native-virtualization/virtio-win container disk no longer needs to be attached to the virtual machine. Remove the container-native-virtualization/virtio-win container disk from the virtual machine configuration file.

Procedure

  1. Edit the configuration file and remove the disk and the volume.

    $ oc edit vm <vm-name>
    spec:
      domain:
        devices:
          disks:
            - name: virtiocontainerdisk
              bootOrder: 2
              cdrom:
                bus: sata
    volumes:
      - containerDisk:
          image: container-native-virtualization/virtio-win
        name: virtiocontainerdisk
  2. Reboot the virtual machine for the changes to take effect.

8.14. Advanced virtual machine management

8.14.1. Working with resource quotas for virtual machines

Create and manage resource quotas for virtual machines.

8.14.1.1. Setting resource quota limits for virtual machines

Resource quotas that only use requests automatically work with virtual machines (VMs). If your resource quota uses limits, you must manually set resource limits on VMs. Resource limits must be at least 100 MiB larger than resource requests.

Procedure

  1. Set limits for a VM by editing the VirtualMachine manifest. For example:

    apiVersion: kubevirt.io/v1
    kind: VirtualMachine
    metadata:
      name: with-limits
    spec:
      running: false
      template:
        spec:
          domain:
    # ...
            resources:
              requests:
                memory: 128Mi
              limits:
                memory: 256Mi  1
    1
    This configuration is supported because the limits.memory value is at least 100Mi larger than the requests.memory value.
  2. Save the VirtualMachine manifest.
8.14.1.2. Additional resources

8.14.2. Specifying nodes for virtual machines

You can place virtual machines (VMs) on specific nodes by using node placement rules.

8.14.2.1. About node placement for virtual machines

To ensure that virtual machines (VMs) run on appropriate nodes, you can configure node placement rules. You might want to do this if:

  • You have several VMs. To ensure fault tolerance, you want them to run on different nodes.
  • You have two chatty VMs. To avoid redundant inter-node routing, you want the VMs to run on the same node.
  • Your VMs require specific hardware features that are not present on all available nodes.
  • You have a pod that adds capabilities to a node, and you want to place a VM on that node so that it can use those capabilities.
Note

Virtual machine placement relies on any existing node placement rules for workloads. If workloads are excluded from specific nodes on the component level, virtual machines cannot be placed on those nodes.

You can use the following rule types in the spec field of a VirtualMachine manifest:

nodeSelector
Allows virtual machines to be scheduled on nodes that are labeled with the key-value pair or pairs that you specify in this field. The node must have labels that exactly match all listed pairs.
affinity

Enables you to use more expressive syntax to set rules that match nodes with virtual machines. For example, you can specify that a rule is a preference, rather than a hard requirement, so that virtual machines are still scheduled if the rule is not satisfied. Pod affinity, pod anti-affinity, and node affinity are supported for virtual machine placement. Pod affinity works for virtual machines because the VirtualMachine workload type is based on the Pod object.

Note

Affinity rules only apply during scheduling. OpenShift Container Platform does not reschedule running workloads if the constraints are no longer met.

tolerations
Allows virtual machines to be scheduled on nodes that have matching taints. If a taint is applied to a node, that node only accepts virtual machines that tolerate the taint.
8.14.2.2. Node placement examples

The following example YAML file snippets use nodePlacement, affinity, and tolerations fields to customize node placement for virtual machines.

8.14.2.2.1. Example: VM node placement with nodeSelector

In this example, the virtual machine requires a node that has metadata containing both example-key-1 = example-value-1 and example-key-2 = example-value-2 labels.

Warning

If there are no nodes that fit this description, the virtual machine is not scheduled.

Example VM manifest

metadata:
  name: example-vm-node-selector
apiVersion: kubevirt.io/v1
kind: VirtualMachine
spec:
  template:
    spec:
      nodeSelector:
        example-key-1: example-value-1
        example-key-2: example-value-2
...

8.14.2.2.2. Example: VM node placement with pod affinity and pod anti-affinity

In this example, the VM must be scheduled on a node that has a running pod with the label example-key-1 = example-value-1. If there is no such pod running on any node, the VM is not scheduled.

If possible, the VM is not scheduled on a node that has any pod with the label example-key-2 = example-value-2. However, if all candidate nodes have a pod with this label, the scheduler ignores this constraint.

Example VM manifest

metadata:
  name: example-vm-pod-affinity
apiVersion: kubevirt.io/v1
kind: VirtualMachine
spec:
  affinity:
    podAffinity:
      requiredDuringSchedulingIgnoredDuringExecution: 1
      - labelSelector:
          matchExpressions:
          - key: example-key-1
            operator: In
            values:
            - example-value-1
        topologyKey: kubernetes.io/hostname
    podAntiAffinity:
      preferredDuringSchedulingIgnoredDuringExecution: 2
      - weight: 100
        podAffinityTerm:
          labelSelector:
            matchExpressions:
            - key: example-key-2
              operator: In
              values:
              - example-value-2
          topologyKey: kubernetes.io/hostname
...

1
If you use the requiredDuringSchedulingIgnoredDuringExecution rule type, the VM is not scheduled if the constraint is not met.
2
If you use the preferredDuringSchedulingIgnoredDuringExecution rule type, the VM is still scheduled if the constraint is not met, as long as all required constraints are met.
8.14.2.2.3. Example: VM node placement with node affinity

In this example, the VM must be scheduled on a node that has the label example.io/example-key = example-value-1 or the label example.io/example-key = example-value-2. The constraint is met if only one of the labels is present on the node. If neither label is present, the VM is not scheduled.

If possible, the scheduler avoids nodes that have the label example-node-label-key = example-node-label-value. However, if all candidate nodes have this label, the scheduler ignores this constraint.

Example VM manifest

metadata:
  name: example-vm-node-affinity
apiVersion: kubevirt.io/v1
kind: VirtualMachine
spec:
  affinity:
    nodeAffinity:
      requiredDuringSchedulingIgnoredDuringExecution: 1
        nodeSelectorTerms:
        - matchExpressions:
          - key: example.io/example-key
            operator: In
            values:
            - example-value-1
            - example-value-2
      preferredDuringSchedulingIgnoredDuringExecution: 2
      - weight: 1
        preference:
          matchExpressions:
          - key: example-node-label-key
            operator: In
            values:
            - example-node-label-value
...

1
If you use the requiredDuringSchedulingIgnoredDuringExecution rule type, the VM is not scheduled if the constraint is not met.
2
If you use the preferredDuringSchedulingIgnoredDuringExecution rule type, the VM is still scheduled if the constraint is not met, as long as all required constraints are met.
8.14.2.2.4. Example: VM node placement with tolerations

In this example, nodes that are reserved for virtual machines are already labeled with the key=virtualization:NoSchedule taint. Because this virtual machine has matching tolerations, it can schedule onto the tainted nodes.

Note

A virtual machine that tolerates a taint is not required to schedule onto a node with that taint.

Example VM manifest

metadata:
  name: example-vm-tolerations
apiVersion: kubevirt.io/v1
kind: VirtualMachine
spec:
  tolerations:
  - key: "key"
    operator: "Equal"
    value: "virtualization"
    effect: "NoSchedule"
...

8.14.2.3. Additional resources

8.14.3. Configuring certificate rotation

Configure certificate rotation parameters to replace existing certificates.

8.14.3.1. Configuring certificate rotation

You can do this during OpenShift Virtualization installation in the web console or after installation in the HyperConverged custom resource (CR).

Procedure

  1. Open the HyperConverged CR by running the following command:

    $ oc edit hco -n openshift-cnv kubevirt-hyperconverged
  2. Edit the spec.certConfig fields as shown in the following example. To avoid overloading the system, ensure that all values are greater than or equal to 10 minutes. Express all values as strings that comply with the golang ParseDuration format.

    apiVersion: hco.kubevirt.io/v1beta1
    kind: HyperConverged
    metadata:
     name: kubevirt-hyperconverged
     namespace: openshift-cnv
    spec:
      certConfig:
        ca:
          duration: 48h0m0s
          renewBefore: 24h0m0s 1
        server:
          duration: 24h0m0s  2
          renewBefore: 12h0m0s  3
    1
    The value of ca.renewBefore must be less than or equal to the value of ca.duration.
    2
    The value of server.duration must be less than or equal to the value of ca.duration.
    3
    The value of server.renewBefore must be less than or equal to the value of server.duration.
  3. Apply the YAML file to your cluster.
8.14.3.2. Troubleshooting certificate rotation parameters

Deleting one or more certConfig values causes them to revert to the default values, unless the default values conflict with one of the following conditions:

  • The value of ca.renewBefore must be less than or equal to the value of ca.duration.
  • The value of server.duration must be less than or equal to the value of ca.duration.
  • The value of server.renewBefore must be less than or equal to the value of server.duration.

If the default values conflict with these conditions, you will receive an error.

If you remove the server.duration value in the following example, the default value of 24h0m0s is greater than the value of ca.duration, conflicting with the specified conditions.

Example

certConfig:
   ca:
     duration: 4h0m0s
     renewBefore: 1h0m0s
   server:
     duration: 4h0m0s
     renewBefore: 4h0m0s

This results in the following error message:

error: hyperconvergeds.hco.kubevirt.io "kubevirt-hyperconverged" could not be patched: admission webhook "validate-hco.kubevirt.io" denied the request: spec.certConfig: ca.duration is smaller than server.duration

The error message only mentions the first conflict. Review all certConfig values before you proceed.

8.14.4. Automating management tasks

You can automate OpenShift Virtualization management tasks by using Red Hat Ansible Automation Platform. Learn the basics by using an Ansible Playbook to create a new virtual machine.

8.14.4.1. About Red Hat Ansible Automation

Ansible is an automation tool used to configure systems, deploy software, and perform rolling updates. Ansible includes support for OpenShift Virtualization, and Ansible modules enable you to automate cluster management tasks such as template, persistent volume claim, and virtual machine operations.

Ansible provides a way to automate OpenShift Virtualization management, which you can also accomplish by using the oc CLI tool or APIs. Ansible is unique because it allows you to integrate KubeVirt modules with other Ansible modules.

8.14.4.2. Automating virtual machine creation

You can use the kubevirt_vm Ansible Playbook to create virtual machines in your OpenShift Container Platform cluster using Red Hat Ansible Automation Platform.

Prerequisites

Procedure

  1. Edit an Ansible Playbook YAML file so that it includes the kubevirt_vm task:

      kubevirt_vm:
        namespace:
        name:
        cpu_cores:
        memory:
        disks:
          - name:
            volume:
              containerDisk:
                image:
            disk:
              bus:
    Note

    This snippet only includes the kubevirt_vm portion of the playbook.

  2. Edit the values to reflect the virtual machine you want to create, including the namespace, the number of cpu_cores, the memory, and the disks. For example:

      kubevirt_vm:
        namespace: default
        name: vm1
        cpu_cores: 1
        memory: 64Mi
        disks:
          - name: containerdisk
            volume:
              containerDisk:
                image: kubevirt/cirros-container-disk-demo:latest
            disk:
              bus: virtio
  3. If you want the virtual machine to boot immediately after creation, add state: running to the YAML file. For example:

      kubevirt_vm:
        namespace: default
        name: vm1
        state: running 1
        cpu_cores: 1
    1
    Changing this value to state: absent deletes the virtual machine, if it already exists.
  4. Run the ansible-playbook command, using your playbook’s file name as the only argument:

    $ ansible-playbook create-vm.yaml
  5. Review the output to determine if the play was successful:

    Example output

    (...)
    TASK [Create my first VM] ************************************************************************
    changed: [localhost]
    
    PLAY RECAP ********************************************************************************************************
    localhost                  : ok=2    changed=1    unreachable=0    failed=0    skipped=0    rescued=0    ignored=0

  6. If you did not include state: running in your playbook file and you want to boot the VM now, edit the file so that it includes state: running and run the playbook again:

    $ ansible-playbook create-vm.yaml

To verify that the virtual machine was created, try to access the VM console.

8.14.4.3. Example: Ansible Playbook for creating virtual machines

You can use the kubevirt_vm Ansible Playbook to automate virtual machine creation.

The following YAML file is an example of the kubevirt_vm playbook. It includes sample values that you must replace with your own information if you run the playbook.

---
- name: Ansible Playbook 1
  hosts: localhost
  connection: local
  tasks:
    - name: Create my first VM
      kubevirt_vm:
        namespace: default
        name: vm1
        cpu_cores: 1
        memory: 64Mi
        disks:
          - name: containerdisk
            volume:
              containerDisk:
                image: kubevirt/cirros-container-disk-demo:latest
            disk:
              bus: virtio

8.14.5. Using EFI mode for virtual machines

You can boot a virtual machine (VM) in Extensible Firmware Interface (EFI) mode.

8.14.5.1. About EFI mode for virtual machines

Extensible Firmware Interface (EFI), like legacy BIOS, initializes hardware components and operating system image files when a computer starts. EFI supports more modern features and customization options than BIOS, enabling faster boot times.

It stores all the information about initialization and startup in a file with a .efi extension, which is stored on a special partition called EFI System Partition (ESP). The ESP also contains the boot loader programs for the operating system that is installed on the computer.

8.14.5.2. Booting virtual machines in EFI mode

You can configure a virtual machine to boot in EFI mode by editing the VM manifest.

Prerequisites

  • Install the OpenShift CLI (oc).

Procedure

  1. Create a YAML file that defines a VM object. Use the firmware stanza of the example YAML file:

    Booting in EFI mode with secure boot active

    apiversion: kubevirt.io/v1
    kind: VirtualMachine
    metadata:
      labels:
        special: vm-secureboot
      name: vm-secureboot
    spec:
      template:
        metadata:
          labels:
            special: vm-secureboot
        spec:
          domain:
            devices:
              disks:
              - disk:
                  bus: virtio
                name: containerdisk
            features:
              acpi: {}
              smm:
                enabled: true 1
            firmware:
              bootloader:
                efi:
                  secureBoot: true 2
    #...

    1
    OpenShift Virtualization requires System Management Mode (SMM) to be enabled for Secure Boot in EFI mode to occur.
    2
    OpenShift Virtualization supports a VM with or without Secure Boot when using EFI mode. If Secure Boot is enabled, then EFI mode is required. However, EFI mode can be enabled without using Secure Boot.
  2. Apply the manifest to your cluster by running the following command:

    $ oc create -f <file_name>.yaml

8.14.6. Configuring PXE booting for virtual machines

PXE booting, or network booting, is available in OpenShift Virtualization. Network booting allows a computer to boot and load an operating system or other program without requiring a locally attached storage device. For example, you can use it to choose your desired OS image from a PXE server when deploying a new host.

8.14.6.1. Prerequisites
  • A Linux bridge must be connected.
  • The PXE server must be connected to the same VLAN as the bridge.
8.14.6.2. PXE booting with a specified MAC address

As an administrator, you can boot a client over the network by first creating a NetworkAttachmentDefinition object for your PXE network. Then, reference the network attachment definition in your virtual machine instance configuration file before you start the virtual machine instance. You can also specify a MAC address in the virtual machine instance configuration file, if required by the PXE server.

Prerequisites

  • A Linux bridge must be connected.
  • The PXE server must be connected to the same VLAN as the bridge.

Procedure

  1. Configure a PXE network on the cluster:

    1. Create the network attachment definition file for PXE network pxe-net-conf:

      apiVersion: "k8s.cni.cncf.io/v1"
      kind: NetworkAttachmentDefinition
      metadata:
        name: pxe-net-conf
      spec:
        config: '{
          "cniVersion": "0.3.1",
          "name": "pxe-net-conf",
          "plugins": [
            {
              "type": "cnv-bridge",
              "bridge": "br1",
              "vlan": 1 1
            },
            {
              "type": "cnv-tuning" 2
            }
          ]
        }'
      1
      Optional: The VLAN tag.
      2
      The cnv-tuning plugin provides support for custom MAC addresses.
      Note

      The virtual machine instance will be attached to the bridge br1 through an access port with the requested VLAN.

  2. Create the network attachment definition by using the file you created in the previous step:

    $ oc create -f pxe-net-conf.yaml
  3. Edit the virtual machine instance configuration file to include the details of the interface and network.

    1. Specify the network and MAC address, if required by the PXE server. If the MAC address is not specified, a value is assigned automatically.

      Ensure that bootOrder is set to 1 so that the interface boots first. In this example, the interface is connected to a network called <pxe-net>:

      interfaces:
      - masquerade: {}
        name: default
      - bridge: {}
        name: pxe-net
        macAddress: de:00:00:00:00:de
        bootOrder: 1
      Note

      Boot order is global for interfaces and disks.

    2. Assign a boot device number to the disk to ensure proper booting after operating system provisioning.

      Set the disk bootOrder value to 2:

      devices:
        disks:
        - disk:
            bus: virtio
          name: containerdisk
          bootOrder: 2
    3. Specify that the network is connected to the previously created network attachment definition. In this scenario, <pxe-net> is connected to the network attachment definition called <pxe-net-conf>:

      networks:
      - name: default
        pod: {}
      - name: pxe-net
        multus:
          networkName: pxe-net-conf
  4. Create the virtual machine instance:

    $ oc create -f vmi-pxe-boot.yaml

Example output

  virtualmachineinstance.kubevirt.io "vmi-pxe-boot" created

  1. Wait for the virtual machine instance to run:

    $ oc get vmi vmi-pxe-boot -o yaml | grep -i phase
      phase: Running
  2. View the virtual machine instance using VNC:

    $ virtctl vnc vmi-pxe-boot
  3. Watch the boot screen to verify that the PXE boot is successful.
  4. Log in to the virtual machine instance:

    $ virtctl console vmi-pxe-boot
  5. Verify the interfaces and MAC address on the virtual machine and that the interface connected to the bridge has the specified MAC address. In this case, we used eth1 for the PXE boot, without an IP address. The other interface, eth0, got an IP address from OpenShift Container Platform.

    $ ip addr

Example output

...
3. eth1: <BROADCAST,MULTICAST> mtu 1500 qdisc noop state DOWN group default qlen 1000
   link/ether de:00:00:00:00:de brd ff:ff:ff:ff:ff:ff

8.14.6.3. OpenShift Virtualization networking glossary

OpenShift Virtualization provides advanced networking functionality by using custom resources and plugins.

The following terms are used throughout OpenShift Virtualization documentation:

Container Network Interface (CNI)
a Cloud Native Computing Foundation project, focused on container network connectivity. OpenShift Virtualization uses CNI plugins to build upon the basic Kubernetes networking functionality.
Multus
a "meta" CNI plugin that allows multiple CNIs to exist so that a pod or virtual machine can use the interfaces it needs.
Custom resource definition (CRD)
a Kubernetes API resource that allows you to define custom resources, or an object defined by using the CRD API resource.
Network attachment definition
a CRD introduced by the Multus project that allows you to attach pods, virtual machines, and virtual machine instances to one or more networks.
Preboot eXecution Environment (PXE)
an interface that enables an administrator to boot a client machine from a server over the network. Network booting allows you to remotely load operating systems and other software onto the client.

8.14.7. Managing guest memory

If you want to adjust guest memory settings to suit a specific use case, you can do so by editing the guest’s YAML configuration file. OpenShift Virtualization allows you to configure guest memory overcommitment and disable guest memory overhead accounting.

Warning

The following procedures increase the chance that virtual machine processes will be killed due to memory pressure. Proceed only if you understand the risks.

8.14.7.1. Configuring guest memory overcommitment

If your virtual workload requires more memory than available, you can use memory overcommitment to allocate all or most of the host’s memory to your virtual machine instances (VMIs). Enabling memory overcommitment means that you can maximize resources that are normally reserved for the host.

For example, if the host has 32 GB RAM, you can use memory overcommitment to fit 8 virtual machines (VMs) with 4 GB RAM each. This allocation works under the assumption that the virtual machines will not use all of their memory at the same time.

Important

Memory overcommitment increases the potential for virtual machine processes to be killed due to memory pressure (OOM killed).

The potential for a VM to be OOM killed varies based on your specific configuration, node memory, available swap space, virtual machine memory consumption, the use of kernel same-page merging (KSM), and other factors.

Procedure

  1. To explicitly tell the virtual machine instance that it has more memory available than was requested from the cluster, edit the virtual machine configuration file and set spec.domain.memory.guest to a higher value than spec.domain.resources.requests.memory. This process is called memory overcommitment.

    In this example, 1024M is requested from the cluster, but the virtual machine instance is told that it has 2048M available. As long as there is enough free memory available on the node, the virtual machine instance will consume up to 2048M.

    kind: VirtualMachine
    spec:
      template:
        domain:
        resources:
            requests:
              memory: 1024M
        memory:
            guest: 2048M
    Note

    The same eviction rules as those for pods apply to the virtual machine instance if the node is under memory pressure.

  2. Create the virtual machine:

    $ oc create -f <file_name>.yaml
8.14.7.2. Disabling guest memory overhead accounting

A small amount of memory is requested by each virtual machine instance in addition to the amount that you request. This additional memory is used for the infrastructure that wraps each VirtualMachineInstance process.

Though it is not usually advisable, it is possible to increase the virtual machine instance density on the node by disabling guest memory overhead accounting.

Important

Disabling guest memory overhead accounting increases the potential for virtual machine processes to be killed due to memory pressure (OOM killed).

The potential for a VM to be OOM killed varies based on your specific configuration, node memory, available swap space, virtual machine memory consumption, the use of kernel same-page merging (KSM), and other factors.

Procedure

  1. To disable guest memory overhead accounting, edit the YAML configuration file and set the overcommitGuestOverhead value to true. This parameter is disabled by default.

    kind: VirtualMachine
    spec:
      template:
        domain:
        resources:
            overcommitGuestOverhead: true
            requests:
              memory: 1024M
    Note

    If overcommitGuestOverhead is enabled, it adds the guest overhead to memory limits, if present.

  2. Create the virtual machine:

    $ oc create -f <file_name>.yaml

8.14.8. Using huge pages with virtual machines

You can use huge pages as backing memory for virtual machines in your cluster.

8.14.8.1. Prerequisites
8.14.8.2. What huge pages do

Memory is managed in blocks known as pages. On most systems, a page is 4Ki. 1Mi of memory is equal to 256 pages; 1Gi of memory is 256,000 pages, and so on. CPUs have a built-in memory management unit that manages a list of these pages in hardware. The Translation Lookaside Buffer (TLB) is a small hardware cache of virtual-to-physical page mappings. If the virtual address passed in a hardware instruction can be found in the TLB, the mapping can be determined quickly. If not, a TLB miss occurs, and the system falls back to slower, software-based address translation, resulting in performance issues. Since the size of the TLB is fixed, the only way to reduce the chance of a TLB miss is to increase the page size.

A huge page is a memory page that is larger than 4Ki. On x86_64 architectures, there are two common huge page sizes: 2Mi and 1Gi. Sizes vary on other architectures. To use huge pages, code must be written so that applications are aware of them. Transparent Huge Pages (THP) attempt to automate the management of huge pages without application knowledge, but they have limitations. In particular, they are limited to 2Mi page sizes. THP can lead to performance degradation on nodes with high memory utilization or fragmentation due to defragmenting efforts of THP, which can lock memory pages. For this reason, some applications may be designed to (or recommend) usage of pre-allocated huge pages instead of THP.

In OpenShift Virtualization, virtual machines can be configured to consume pre-allocated huge pages.

8.14.8.3. Configuring huge pages for virtual machines

You can configure virtual machines to use pre-allocated huge pages by including the memory.hugepages.pageSize and resources.requests.memory parameters in your virtual machine configuration.

The memory request must be divisible by the page size. For example, you cannot request 500Mi memory with a page size of 1Gi.

Note

The memory layouts of the host and the guest OS are unrelated. Huge pages requested in the virtual machine manifest apply to QEMU. Huge pages inside the guest can only be configured based on the amount of available memory of the virtual machine instance.

If you edit a running virtual machine, the virtual machine must be rebooted for the changes to take effect.

Prerequisites

  • Nodes must have pre-allocated huge pages configured.

Procedure

  1. In your virtual machine configuration, add the resources.requests.memory and memory.hugepages.pageSize parameters to the spec.domain. The following configuration snippet is for a virtual machine that requests a total of 4Gi memory with a page size of 1Gi:

    kind: VirtualMachine
    ...
    spec:
      domain:
        resources:
          requests:
            memory: "4Gi" 1
        memory:
          hugepages:
            pageSize: "1Gi" 2
    ...
    1
    The total amount of memory requested for the virtual machine. This value must be divisible by the page size.
    2
    The size of each huge page. Valid values for x86_64 architecture are 1Gi and 2Mi. The page size must be smaller than the requested memory.
  2. Apply the virtual machine configuration:

    $ oc apply -f <virtual_machine>.yaml

8.14.9. Enabling dedicated resources for virtual machines

To improve performance, you can dedicate node resources, such as CPU, to a virtual machine.

8.14.9.1. About dedicated resources

When you enable dedicated resources for your virtual machine, your virtual machine’s workload is scheduled on CPUs that will not be used by other processes. By using dedicated resources, you can improve the performance of the virtual machine and the accuracy of latency predictions.

8.14.9.2. Prerequisites
  • The CPU Manager must be configured on the node. Verify that the node has the cpumanager = true label before scheduling virtual machine workloads.
  • The virtual machine must be powered off.
8.14.9.3. Enabling dedicated resources for a virtual machine

You can enable dedicated resources for a virtual machine in the Details tab. Virtual machines that were created by using a Red Hat template or the wizard can be enabled with dedicated resources.

Procedure

  1. Click WorkloadsVirtual Machines from the side menu.
  2. Select a virtual machine to open the Virtual Machine tab.
  3. Click the Details tab.
  4. Click the pencil icon to the right of the Dedicated Resources field to open the Dedicated Resources window.
  5. Select Schedule this workload with dedicated resources (guaranteed policy).
  6. Click Save.

8.14.10. Scheduling virtual machines

You can schedule a virtual machine (VM) on a node by ensuring that the VM’s CPU model and policy attribute are matched for compatibility with the CPU models and policy attributes supported by the node.

8.14.10.1. Policy attributes

You can schedule a virtual machine (VM) by specifying a policy attribute and a CPU feature that is matched for compatibility when the VM is scheduled on a node. A policy attribute specified for a VM determines how that VM is scheduled on a node.

Policy attributeDescription

force

The VM is forced to be scheduled on a node. This is true even if the host CPU does not support the VM’s CPU.

require

Default policy that applies to a VM if the VM is not configured with a specific CPU model and feature specification. If a node is not configured to support CPU node discovery with this default policy attribute or any one of the other policy attributes, VMs are not scheduled on that node. Either the host CPU must support the VM’s CPU or the hypervisor must be able to emulate the supported CPU model.

optional

The VM is added to a node if that VM is supported by the host’s physical machine CPU.

disable

The VM cannot be scheduled with CPU node discovery.

forbid

The VM is not scheduled even if the feature is supported by the host CPU and CPU node discovery is enabled.

8.14.10.2. Setting a policy attribute and CPU feature

You can set a policy attribute and CPU feature for each virtual machine (VM) to ensure that it is scheduled on a node according to policy and feature. The CPU feature that you set is verified to ensure that it is supported by the host CPU or emulated by the hypervisor.

Procedure

  • Edit the domain spec of your VM configuration file. The following example sets the CPU feature and the require policy for a virtual machine (VM):

    apiVersion: kubevirt.io/v1
    kind: VirtualMachine
    metadata:
      name: myvm
    spec:
      template:
        spec:
          domain:
            cpu:
              features:
                - name: apic 1
                  policy: require 2
    1
    Name of the CPU feature for the VM.
    2
    Policy attribute for the VM.
8.14.10.3. Scheduling virtual machines with the supported CPU model

You can configure a CPU model for a virtual machine (VM) to schedule it on a node where its CPU model is supported.

Procedure

  • Edit the domain spec of your virtual machine configuration file. The following example shows a specific CPU model defined for a VM:

    apiVersion: kubevirt.io/v1
    kind: VirtualMachine
    metadata:
      name: myvm
    spec:
      template:
        spec:
          domain:
            cpu:
              model: Conroe 1
    1
    CPU model for the VM.
8.14.10.4. Scheduling virtual machines with the host model

When the CPU model for a virtual machine (VM) is set to host-model, the VM inherits the CPU model of the node where it is scheduled.

Procedure

  • Edit the domain spec of your VM configuration file. The following example shows host-model being specified for the virtual machine:

    apiVersion: kubevirt/v1alpha3
    kind: VirtualMachine
    metadata:
      name: myvm
    spec:
      template:
        spec:
          domain:
            cpu:
              model: host-model 1
    1
    The VM that inherits the CPU model of the node where it is scheduled.

8.14.11. Configuring PCI passthrough

The Peripheral Component Interconnect (PCI) passthrough feature enables you to access and manage hardware devices from a virtual machine. When PCI passthrough is configured, the PCI devices function as if they were physically attached to the guest operating system.

Cluster administrators can expose and manage host devices that are permitted to be used in the cluster by using the oc command-line interface (CLI).

8.14.11.1. About preparing a host device for PCI passthrough

To prepare a host device for PCI passthrough by using the CLI, create a MachineConfig object and add kernel arguments to enable the Input-Output Memory Management Unit (IOMMU). Bind the PCI device to the Virtual Function I/O (VFIO) driver and then expose it in the cluster by editing the permittedHostDevices field of the HyperConverged custom resource (CR). The permittedHostDevices list is empty when you first install the OpenShift Virtualization Operator.

To remove a PCI host device from the cluster by using the CLI, delete the PCI device information from the HyperConverged CR.

8.14.11.1.1. Adding kernel arguments to enable the IOMMU driver

To enable the IOMMU (Input-Output Memory Management Unit) driver in the kernel, create the MachineConfig object and add the kernel arguments.

Prerequisites

  • Administrative privilege to a working OpenShift Container Platform cluster.
  • Intel or AMD CPU hardware.
  • Intel Virtualization Technology for Directed I/O extensions or AMD IOMMU in the BIOS (Basic Input/Output System) is enabled.

Procedure

  1. Create a MachineConfig object that identifies the kernel argument. The following example shows a kernel argument for an Intel CPU.

    apiVersion: machineconfiguration.openshift.io/v1
    kind: MachineConfig
    metadata:
      labels:
        machineconfiguration.openshift.io/role: worker 1
      name: 100-worker-iommu 2
    spec:
      config:
        ignition:
          version: 3.2.0
      kernelArguments:
          - intel_iommu=on 3
    ...
    1
    Applies the new kernel argument only to worker nodes.
    2
    The name indicates the ranking of this kernel argument (100) among the machine configs and its purpose. If you have an AMD CPU, specify the kernel argument as amd_iommu=on.
    3
    Identifies the kernel argument as intel_iommu for an Intel CPU.
  2. Create the new MachineConfig object:

    $ oc create -f 100-worker-kernel-arg-iommu.yaml

Verification

  • Verify that the new MachineConfig object was added.

    $ oc get MachineConfig
8.14.11.1.2. Binding PCI devices to the VFIO driver

To bind PCI devices to the VFIO (Virtual Function I/O) driver, obtain the values for vendor-ID and device-ID from each device and create a list with the values. Add this list to the MachineConfig object. The MachineConfig Operator generates the /etc/modprobe.d/vfio.conf on the nodes with the PCI devices, and binds the PCI devices to the VFIO driver.

Prerequisites

  • You added kernel arguments to enable IOMMU for the CPU.

Procedure

  1. Run the lspci command to obtain the vendor-ID and the device-ID for the PCI device.

    $ lspci -nnv | grep -i nvidia

    Example output

    02:01.0 3D controller [0302]: NVIDIA Corporation GV100GL [Tesla V100 PCIe 32GB] [10de:1eb8] (rev a1)

  2. Create a Butane config file, 100-worker-vfiopci.bu, binding the PCI device to the VFIO driver.

    Note

    See "Creating machine configs with Butane" for information about Butane.

    Example

    variant: openshift
    version: 4.9.0
    metadata:
      name: 100-worker-vfiopci
      labels:
        machineconfiguration.openshift.io/role: worker 1
    storage:
      files:
      - path: /etc/modprobe.d/vfio.conf
        mode: 0644
        overwrite: true
        contents:
          inline: |
            options vfio-pci ids=10de:1eb8 2
      - path: /etc/modules-load.d/vfio-pci.conf 3
        mode: 0644
        overwrite: true
        contents:
          inline: vfio-pci

    1
    Applies the new kernel argument only to worker nodes.
    2
    Specify the previously determined vendor-ID value (10de) and the device-ID value (1eb8) to bind a single device to the VFIO driver. You can add a list of multiple devices with their vendor and device information.
    3
    The file that loads the vfio-pci kernel module on the worker nodes.
  3. Use Butane to generate a MachineConfig object file, 100-worker-vfiopci.yaml, containing the configuration to be delivered to the worker nodes:

    $ butane 100-worker-vfiopci.bu -o 100-worker-vfiopci.yaml
  4. Apply the MachineConfig object to the worker nodes:

    $ oc apply -f 100-worker-vfiopci.yaml
  5. Verify that the MachineConfig object was added.

    $ oc get MachineConfig

    Example output

    NAME                             GENERATEDBYCONTROLLER                      IGNITIONVERSION  AGE
    00-master                        d3da910bfa9f4b599af4ed7f5ac270d55950a3a1   3.2.0            25h
    00-worker                        d3da910bfa9f4b599af4ed7f5ac270d55950a3a1   3.2.0            25h
    01-master-container-runtime      d3da910bfa9f4b599af4ed7f5ac270d55950a3a1   3.2.0            25h
    01-master-kubelet                d3da910bfa9f4b599af4ed7f5ac270d55950a3a1   3.2.0            25h
    01-worker-container-runtime      d3da910bfa9f4b599af4ed7f5ac270d55950a3a1   3.2.0            25h
    01-worker-kubelet                d3da910bfa9f4b599af4ed7f5ac270d55950a3a1   3.2.0            25h
    100-worker-iommu                                                            3.2.0            30s
    100-worker-vfiopci-configuration                                            3.2.0            30s

Verification

  • Verify that the VFIO driver is loaded.

    $ lspci -nnk -d 10de:

    The output confirms that the VFIO driver is being used.

    Example output

    04:00.0 3D controller [0302]: NVIDIA Corporation GP102GL [Tesla P40] [10de:1eb8] (rev a1)
            Subsystem: NVIDIA Corporation Device [10de:1eb8]
            Kernel driver in use: vfio-pci
            Kernel modules: nouveau

8.14.11.1.3. Exposing PCI host devices in the cluster using the CLI

To expose PCI host devices in the cluster, add details about the PCI devices to the spec.permittedHostDevices.pciHostDevices array of the HyperConverged custom resource (CR).

Procedure

  1. Edit the HyperConverged CR in your default editor by running the following command:

    $ oc edit hyperconverged kubevirt-hyperconverged -n openshift-cnv
  2. Add the PCI device information to the spec.permittedHostDevices.pciHostDevices array. For example:

    Example configuration file

    apiVersion: hco.kubevirt.io/v1
    kind: HyperConverged
    metadata:
      name: kubevirt-hyperconverged
      namespace: openshift-cnv
    spec:
      permittedHostDevices: 1
        pciHostDevices: 2
        - pciDeviceSelector: "10DE:1DB6" 3
          resourceName: "nvidia.com/GV100GL_Tesla_V100" 4
        - pciDeviceSelector: "10DE:1EB8"
          resourceName: "nvidia.com/TU104GL_Tesla_T4"
        - pciDeviceSelector: "8086:6F54"
          resourceName: "intel.com/qat"
          externalResourceProvider: true 5
    ...

    1
    The host devices that are permitted to be used in the cluster.
    2
    The list of PCI devices available on the node.
    3
    The vendor-ID and the device-ID required to identify the PCI device.
    4
    The name of a PCI host device.
    5
    Optional: Setting this field to true indicates that the resource is provided by an external device plugin. OpenShift Virtualization allows the usage of this device in the cluster but leaves the allocation and monitoring to an external device plugin.
    Note

    The above example snippet shows two PCI host devices that are named nvidia.com/GV100GL_Tesla_V100 and nvidia.com/TU104GL_Tesla_T4 added to the list of permitted host devices in the HyperConverged CR. These devices have been tested and verified to work with OpenShift Virtualization.

  3. Save your changes and exit the editor.

Verification

  • Verify that the PCI host devices were added to the node by running the following command. The example output shows that there is one device each associated with the nvidia.com/GV100GL_Tesla_V100, nvidia.com/TU104GL_Tesla_T4, and intel.com/qat resource names.

    $ oc describe node <node_name>

    Example output

    Capacity:
      cpu:                            64
      devices.kubevirt.io/kvm:        110
      devices.kubevirt.io/tun:        110
      devices.kubevirt.io/vhost-net:  110
      ephemeral-storage:              915128Mi
      hugepages-1Gi:                  0
      hugepages-2Mi:                  0
      memory:                         131395264Ki
      nvidia.com/GV100GL_Tesla_V100   1
      nvidia.com/TU104GL_Tesla_T4     1
      intel.com/qat:                  1
      pods:                           250
    Allocatable:
      cpu:                            63500m
      devices.kubevirt.io/kvm:        110
      devices.kubevirt.io/tun:        110
      devices.kubevirt.io/vhost-net:  110
      ephemeral-storage:              863623130526
      hugepages-1Gi:                  0
      hugepages-2Mi:                  0
      memory:                         130244288Ki
      nvidia.com/GV100GL_Tesla_V100   1
      nvidia.com/TU104GL_Tesla_T4     1
      intel.com/qat:                  1
      pods:                           250

8.14.11.1.4. Removing PCI host devices from the cluster using the CLI

To remove a PCI host device from the cluster, delete the information for that device from the HyperConverged custom resource (CR).

Procedure

  1. Edit the HyperConverged CR in your default editor by running the following command:

    $ oc edit hyperconverged kubevirt-hyperconverged -n openshift-cnv
  2. Remove the PCI device information from the spec.permittedHostDevices.pciHostDevices array by deleting the pciDeviceSelector, resourceName and externalResourceProvider (if applicable) fields for the appropriate device. In this example, the intel.com/qat resource has been deleted.

    Example configuration file

    apiVersion: hco.kubevirt.io/v1
    kind: HyperConverged
    metadata:
      name: kubevirt-hyperconverged
      namespace: openshift-cnv
    spec:
      permittedHostDevices:
        pciHostDevices:
        - pciDeviceSelector: "10DE:1DB6"
          resourceName: "nvidia.com/GV100GL_Tesla_V100"
        - pciDeviceSelector: "10DE:1EB8"
          resourceName: "nvidia.com/TU104GL_Tesla_T4"
    ...

  3. Save your changes and exit the editor.

Verification

  • Verify that the PCI host device was removed from the node by running the following command. The example output shows that there are zero devices associated with the intel.com/qat resource name.

    $ oc describe node <node_name>

    Example output

    Capacity:
      cpu:                            64
      devices.kubevirt.io/kvm:        110
      devices.kubevirt.io/tun:        110
      devices.kubevirt.io/vhost-net:  110
      ephemeral-storage:              915128Mi
      hugepages-1Gi:                  0
      hugepages-2Mi:                  0
      memory:                         131395264Ki
      nvidia.com/GV100GL_Tesla_V100   1
      nvidia.com/TU104GL_Tesla_T4     1
      intel.com/qat:                  0
      pods:                           250
    Allocatable:
      cpu:                            63500m
      devices.kubevirt.io/kvm:        110
      devices.kubevirt.io/tun:        110
      devices.kubevirt.io/vhost-net:  110
      ephemeral-storage:              863623130526
      hugepages-1Gi:                  0
      hugepages-2Mi:                  0
      memory:                         130244288Ki
      nvidia.com/GV100GL_Tesla_V100   1
      nvidia.com/TU104GL_Tesla_T4     1
      intel.com/qat:                  0
      pods:                           250

8.14.11.2. Configuring virtual machines for PCI passthrough

After the PCI devices have been added to the cluster, you can assign them to virtual machines. The PCI devices are now available as if they are physically connected to the virtual machines.

8.14.11.2.1. Assigning a PCI device to a virtual machine

When a PCI device is available in a cluster, you can assign it to a virtual machine and enable PCI passthrough.

Procedure

  • Assign the PCI device to a virtual machine as a host device.

    Example

    apiVersion: kubevirt.io/v1
    kind: VirtualMachine
    spec:
      domain:
        devices:
          hostDevices:
          - deviceName: nvidia.com/TU104GL_Tesla_T4 1
            name: hostdevices1

    1
    The name of the PCI device that is permitted on the cluster as a host device. The virtual machine can access this host device.

Verification

  • Use the following command to verify that the host device is available from the virtual machine.

    $ lspci -nnk | grep NVIDIA

    Example output

    $ 02:01.0 3D controller [0302]: NVIDIA Corporation GV100GL [Tesla V100 PCIe 32GB] [10de:1eb8] (rev a1)

8.14.11.3. Additional resources

8.14.12. Configuring a watchdog

Expose a watchdog by configuring the virtual machine (VM) for a watchdog device, installing the watchdog, and starting the watchdog service.

8.14.12.1. Prerequisites
  • The virtual machine must have kernel support for an i6300esb watchdog device. Red Hat Enterprise Linux (RHEL) images support i6300esb.
8.14.12.2. Defining a watchdog device

Define how the watchdog proceeds when the operating system (OS) no longer responds.

Table 8.3. Available actions

poweroff

The virtual machine (VM) powers down immediately. If spec.running is set to true, or spec.runStrategy is not set to manual, then the VM reboots.

reset

The VM reboots in place and the guest OS cannot react. Because the length of time required for the guest OS to reboot can cause liveness probes to timeout, use of this option is discouraged. This timeout can extend the time it takes the VM to reboot if cluster-level protections notice the liveness probe failed and forcibly reschedule it.

shutdown

The VM gracefully powers down by stopping all services.

Procedure

  1. Create a YAML file with the following contents:

    apiVersion: kubevirt.io/v1
    kind: VirtualMachine
    metadata:
      labels:
        kubevirt.io/vm: vm2-rhel84-watchdog
      name: <vm-name>
    spec:
      running: false
      template:
        metadata:
         labels:
            kubevirt.io/vm: vm2-rhel84-watchdog
        spec:
          domain:
            devices:
              watchdog:
                name: <watchdog>
                i6300esb:
                  action: "poweroff" 1
    ...
    1
    Specify the watchdog action (poweroff, reset, or shutdown).

    The example above configures the i6300esb watchdog device on a RHEL8 VM with the poweroff action and exposes the device as /dev/watchdog.

    This device can now be used by the watchdog binary.

  2. Apply the YAML file to your cluster by running the following command:

    $ oc apply -f <file_name>.yaml
Important

This procedure is provided for testing watchdog functionality only and must not be run on production machines.

  1. Run the following command to verify that the VM is connected to the watchdog device:

    $ lspci | grep watchdog -i
  2. Run one of the following commands to confirm the watchdog is active:

    • Trigger a kernel panic:

      # echo c > /proc/sysrq-trigger
    • Terminate the watchdog service:

      # pkill -9 watchdog
8.14.12.3. Installing a watchdog device

Install the watchdog package on your virtual machine and start the watchdog service.

Procedure

  1. As a root user, install the watchdog package and dependencies:

    # yum install watchdog
  2. Uncomment the following line in the /etc/watchdog.conf file, and save the changes:

    #watchdog-device = /dev/watchdog
  3. Enable the watchdog service to start on boot:

    # systemctl enable --now watchdog.service
8.14.12.4. Additional resources

8.15. Importing virtual machines

8.15.1. TLS certificates for data volume imports

8.15.1.1. Adding TLS certificates for authenticating data volume imports

TLS certificates for registry or HTTPS endpoints must be added to a config map to import data from these sources. This config map must be present in the namespace of the destination data volume.

Create the config map by referencing the relative file path for the TLS certificate.

Procedure

  1. Ensure you are in the correct namespace. The config map can only be referenced by data volumes if it is in the same namespace.

    $ oc get ns
  2. Create the config map:

    $ oc create configmap <configmap-name> --from-file=</path/to/file/ca.pem>
8.15.1.2. Example: Config map created from a TLS certificate

The following example is of a config map created from ca.pem TLS certificate.

apiVersion: v1
kind: ConfigMap
metadata:
  name: tls-certs
data:
  ca.pem: |
    -----BEGIN CERTIFICATE-----
    ... <base64 encoded cert> ...
    -----END CERTIFICATE-----

8.15.2. Importing virtual machine images with data volumes

Use the Containerized Data Importer (CDI) to import a virtual machine image into a persistent volume claim (PVC) by using a data volume. You can attach a data volume to a virtual machine for persistent storage.

The virtual machine image can be hosted at an HTTP or HTTPS endpoint, or built into a container disk and stored in a container registry.

Important

When you import a disk image into a PVC, the disk image is expanded to use the full storage capacity that is requested in the PVC. To use this space, the disk partitions and file system(s) in the virtual machine might need to be expanded.

The resizing procedure varies based on the operating system installed on the virtual machine. See the operating system documentation for details.

8.15.2.1. Prerequisites
8.15.2.2. CDI supported operations matrix

This matrix shows the supported CDI operations for content types against endpoints, and which of these operations requires scratch space.

Content typesHTTPHTTPSHTTP basic authRegistryUpload

KubeVirt (QCOW2)

✓ QCOW2
✓ GZ*
✓ XZ*

✓ QCOW2**
✓ GZ*
✓ XZ*

✓ QCOW2
✓ GZ*
✓ XZ*

✓ QCOW2*
□ GZ
□ XZ

✓ QCOW2*
✓ GZ*
✓ XZ*

KubeVirt (RAW)

✓ RAW
✓ GZ
✓ XZ

✓ RAW
✓ GZ
✓ XZ

✓ RAW
✓ GZ
✓ XZ

✓ RAW*
□ GZ
□ XZ

✓ RAW*
✓ GZ*
✓ XZ*

✓ Supported operation

□ Unsupported operation

* Requires scratch space

** Requires scratch space if a custom certificate authority is required

Note

CDI now uses the OpenShift Container Platform cluster-wide proxy configuration.

8.15.2.3. About data volumes

DataVolume objects are custom resources that are provided by the Containerized Data Importer (CDI) project. Data volumes orchestrate import, clone, and upload operations that are associated with an underlying persistent volume claim (PVC). Data volumes are integrated with OpenShift Virtualization, and they prevent a virtual machine from being started before the PVC has been prepared.

8.15.2.4. Importing a virtual machine image into storage by using a data volume

You can import a virtual machine image into storage by using a data volume.

The virtual machine image can be hosted at an HTTP or HTTPS endpoint or the image can be built into a container disk and stored in a container registry.

You specify the data source for the image in a VirtualMachine configuration file. When the virtual machine is created, the data volume with the virtual machine image is imported into storage.

Prerequisites

  • To import a virtual machine image you must have the following:

    • A virtual machine disk image in RAW, ISO, or QCOW2 format, optionally compressed by using xz or gz.
    • An HTTP or HTTPS endpoint where the image is hosted, along with any authentication credentials needed to access the data source.
  • To import a container disk, you must have a virtual machine image built into a container disk and stored in a container registry, along with any authentication credentials needed to access the data source.
  • If the virtual machine must communicate with servers that use self-signed certificates or certificates not signed by the system CA bundle, you must create a config map in the same namespace as the data volume.

Procedure

  1. If your data source requires authentication, create a Secret manifest, specifying the data source credentials, and save it as endpoint-secret.yaml:

    apiVersion: v1
    kind: Secret
    metadata:
      name: endpoint-secret 1
      labels:
        app: containerized-data-importer
    type: Opaque
    data:
      accessKeyId: "" 2
      secretKey:   "" 3
    1
    Specify the name of the Secret.
    2
    Specify the Base64-encoded key ID or user name.
    3
    Specify the Base64-encoded secret key or password.
  2. Apply the Secret manifest:

    $ oc apply -f endpoint-secret.yaml
  3. Edit the VirtualMachine manifest, specifying the data source for the virtual machine image you want to import, and save it as vm-fedora-datavolume.yaml:

    apiVersion: kubevirt.io/v1
    kind: VirtualMachine
    metadata:
      creationTimestamp: null
      labels:
        kubevirt.io/vm: vm-fedora-datavolume
      name: vm-fedora-datavolume 1
    spec:
      dataVolumeTemplates:
      - metadata:
          creationTimestamp: null
          name: fedora-dv 2
        spec:
          storage:
            resources:
              requests:
                storage: 10Gi
            storageClassName: local
          source:
            http: 3
              url: "https://mirror.arizona.edu/fedora/linux/releases/35/Cloud/x86_64/images/Fedora-Cloud-Base-35-1.2.x86_64.qcow2" 4
              secretRef: endpoint-secret 5
              certConfigMap: "" 6
        status: {}
      running: true
      template:
        metadata:
          creationTimestamp: null
          labels:
            kubevirt.io/vm: vm-fedora-datavolume
        spec:
          domain:
            devices:
              disks:
              - disk:
                  bus: virtio
                name: datavolumedisk1
            machine:
              type: ""
            resources:
              requests:
                memory: 1.5Gi
          terminationGracePeriodSeconds: 180
          volumes:
          - dataVolume:
              name: fedora-dv
            name: datavolumedisk1
    status: {}
    1
    Specify the name of the virtual machine.
    2
    Specify the name of the data volume.
    3
    Specify http for an HTTP or HTTPS endpoint. Specify registry for a container disk image imported from a registry.
    4
    The source of the virtual machine image you want to import. This example references a virtual machine image at an HTTPS endpoint. An example of a container registry endpoint is url: "docker://kubevirt/fedora-cloud-container-disk-demo:latest".
    5
    Required if you created a Secret for the data source.
    6
    Optional: Specify a CA certificate config map.
  4. Create the virtual machine:

    $ oc create -f vm-fedora-datavolume.yaml
    Note

    The oc create command creates the data volume and the virtual machine. The CDI controller creates an underlying PVC with the correct annotation and the import process begins. When the import is complete, the data volume status changes to Succeeded. You can start the virtual machine.

    Data volume provisioning happens in the background, so there is no need to monitor the process.

Verification

  1. The importer pod downloads the virtual machine image or container disk from the specified URL and stores it on the provisioned PV. View the status of the importer pod by running the following command:

    $ oc get pods
  2. Monitor the data volume until its status is Succeeded by running the following command:

    $ oc describe dv fedora-dv 1
    1
    Specify the data volume name that you defined in the VirtualMachine manifest.
  3. Verify that provisioning is complete and that the virtual machine has started by accessing its serial console:

    $ virtctl console vm-fedora-datavolume
8.15.2.5. Additional resources

8.15.3. Importing virtual machine images into block storage with data volumes

You can import an existing virtual machine image into your OpenShift Container Platform cluster. OpenShift Virtualization uses data volumes to automate the import of data and the creation of an underlying persistent volume claim (PVC).

Important

When you import a disk image into a PVC, the disk image is expanded to use the full storage capacity that is requested in the PVC. To use this space, the disk partitions and file system(s) in the virtual machine might need to be expanded.

The resizing procedure varies based on the operating system that is installed on the virtual machine. See the operating system documentation for details.

8.15.3.1. Prerequisites
8.15.3.2. About data volumes

DataVolume objects are custom resources that are provided by the Containerized Data Importer (CDI) project. Data volumes orchestrate import, clone, and upload operations that are associated with an underlying persistent volume claim (PVC). Data volumes are integrated with OpenShift Virtualization, and they prevent a virtual machine from being started before the PVC has been prepared.

8.15.3.3. About block persistent volumes

A block persistent volume (PV) is a PV that is backed by a raw block device. These volumes do not have a file system and can provide performance benefits for virtual machines by reducing overhead.

Raw block volumes are provisioned by specifying volumeMode: Block in the PV and persistent volume claim (PVC) specification.

8.15.3.4. Creating a local block persistent volume

Create a local block persistent volume (PV) on a node by populating a file and mounting it as a loop device. You can then reference this loop device in a PV manifest as a Block volume and use it as a block device for a virtual machine image.

Procedure

  1. Log in as root to the node on which to create the local PV. This procedure uses node01 for its examples.
  2. Create a file and populate it with null characters so that it can be used as a block device. The following example creates a file loop10 with a size of 2Gb (20 100Mb blocks):

    $ dd if=/dev/zero of=<loop10> bs=100M count=20
  3. Mount the loop10 file as a loop device.

    $ losetup </dev/loop10>d3 <loop10> 1 2
    1
    File path where the loop device is mounted.
    2
    The file created in the previous step to be mounted as the loop device.
  4. Create a PersistentVolume manifest that references the mounted loop device.

    kind: PersistentVolume
    apiVersion: v1
    metadata:
      name: <local-block-pv10>
      annotations:
    spec:
      local:
        path: </dev/loop10> 1
      capacity:
        storage: <2Gi>
      volumeMode: Block 2
      storageClassName: local 3
      accessModes:
        - ReadWriteOnce
      persistentVolumeReclaimPolicy: Delete
      nodeAffinity:
        required:
          nodeSelectorTerms:
          - matchExpressions:
            - key: kubernetes.io/hostname
              operator: In
              values:
              - <node01> 4
    1
    The path of the loop device on the node.
    2
    Specifies it is a block PV.
    3
    Optional: Set a storage class for the PV. If you omit it, the cluster default is used.
    4
    The node on which the block device was mounted.
  5. Create the block PV.

    # oc create -f <local-block-pv10.yaml>1
    1
    The file name of the persistent volume created in the previous step.
8.15.3.5. Importing a virtual machine image into block storage by using a data volume

You can import a virtual machine image into block storage by using a data volume. You reference the data volume in a VirtualMachine manifest before you create a virtual machine.

Prerequisites

  • A virtual machine disk image in RAW, ISO, or QCOW2 format, optionally compressed by using xz or gz.
  • An HTTP or HTTPS endpoint where the image is hosted, along with any authentication credentials needed to access the data source.

Procedure

  1. If your data source requires authentication, create a Secret manifest, specifying the data source credentials, and save it as endpoint-secret.yaml:

    apiVersion: v1
    kind: Secret
    metadata:
      name: endpoint-secret 1
      labels:
        app: containerized-data-importer
    type: Opaque
    data:
      accessKeyId: "" 2
      secretKey:   "" 3
    1
    Specify the name of the Secret.
    2
    Specify the Base64-encoded key ID or user name.
    3
    Specify the Base64-encoded secret key or password.
  2. Apply the Secret manifest:

    $ oc apply -f endpoint-secret.yaml
  3. Create a DataVolume manifest, specifying the data source for the virtual machine image and Block for storage.volumeMode.

    apiVersion: cdi.kubevirt.io/v1beta1
    kind: DataVolume
    metadata:
      name: import-pv-datavolume 1
    spec:
      storageClassName: local 2
        source:
          http:
            url: "https://mirror.arizona.edu/fedora/linux/releases/35/Cloud/x86_64/images/Fedora-Cloud-Base-35-1.2.x86_64.qcow2" 3
            secretRef: endpoint-secret 4
      storage:
        volumeMode: Block 5
        resources:
          requests:
            storage: 10Gi
    1
    Specify the name of the data volume.
    2
    Optional: Set the storage class or omit it to accept the cluster default.
    3
    Specify the HTTP or HTTPS URL of the image to import.
    4
    Required if you created a Secret for the data source.
    5
    The volume mode and access mode are detected automatically for known storage provisioners. Otherwise, specify Block.
  4. Create the data volume to import the virtual machine image:

    $ oc create -f import-pv-datavolume.yaml

You can reference this data volume in a VirtualMachine manifest before you create a virtual machine.

8.15.3.6. CDI supported operations matrix

This matrix shows the supported CDI operations for content types against endpoints, and which of these operations requires scratch space.

Content typesHTTPHTTPSHTTP basic authRegistryUpload

KubeVirt (QCOW2)

✓ QCOW2
✓ GZ*
✓ XZ*

✓ QCOW2**
✓ GZ*
✓ XZ*

✓ QCOW2
✓ GZ*
✓ XZ*

✓ QCOW2*
□ GZ
□ XZ

✓ QCOW2*
✓ GZ*
✓ XZ*

KubeVirt (RAW)

✓ RAW
✓ GZ
✓ XZ

✓ RAW
✓ GZ
✓ XZ

✓ RAW
✓ GZ
✓ XZ

✓ RAW*
□ GZ
□ XZ

✓ RAW*
✓ GZ*
✓ XZ*

✓ Supported operation

□ Unsupported operation

* Requires scratch space

** Requires scratch space if a custom certificate authority is required

Note

CDI now uses the OpenShift Container Platform cluster-wide proxy configuration.

8.15.3.7. Additional resources

8.16. Cloning virtual machines

8.16.1. Enabling user permissions to clone data volumes across namespaces

The isolating nature of namespaces means that users cannot by default clone resources between namespaces.

To enable a user to clone a virtual machine to another namespace, a user with the cluster-admin role must create a new cluster role. Bind this cluster role to a user to enable them to clone virtual machines to the destination namespace.

8.16.1.1. Prerequisites
  • Only a user with the cluster-admin role can create cluster roles.
8.16.1.2. About data volumes

DataVolume objects are custom resources that are provided by the Containerized Data Importer (CDI) project. Data volumes orchestrate import, clone, and upload operations that are associated with an underlying persistent volume claim (PVC). Data volumes are integrated with OpenShift Virtualization, and they prevent a virtual machine from being started before the PVC has been prepared.

8.16.1.3. Creating RBAC resources for cloning data volumes

Create a new cluster role that enables permissions for all actions for the datavolumes resource.

Procedure

  1. Create a ClusterRole manifest:

    apiVersion: rbac.authorization.k8s.io/v1
    kind: ClusterRole
    metadata:
      name: <datavolume-cloner> 1
    rules:
    - apiGroups: ["cdi.kubevirt.io"]
      resources: ["datavolumes/source"]
      verbs: ["*"]
    1
    Unique name for the cluster role.
  2. Create the cluster role in the cluster:

    $ oc create -f <datavolume-cloner.yaml> 1
    1
    The file name of the ClusterRole manifest created in the previous step.
  3. Create a RoleBinding manifest that applies to both the source and destination namespaces and references the cluster role created in the previous step.

    apiVersion: rbac.authorization.k8s.io/v1
    kind: RoleBinding
    metadata:
      name: <allow-clone-to-user> 1
      namespace: <Source namespace> 2
    subjects:
    - kind: ServiceAccount
      name: default
      namespace: <Destination namespace> 3
    roleRef:
      kind: ClusterRole
      name: datavolume-cloner 4
      apiGroup: rbac.authorization.k8s.io
    1
    Unique name for the role binding.
    2
    The namespace for the source data volume.
    3
    The namespace to which the data volume is cloned.
    4
    The name of the cluster role created in the previous step.
  4. Create the role binding in the cluster:

    $ oc create -f <datavolume-cloner.yaml> 1
    1
    The file name of the RoleBinding manifest created in the previous step.

8.16.2. Cloning a virtual machine disk into a new data volume

You can clone the persistent volume claim (PVC) of a virtual machine disk into a new data volume by referencing the source PVC in your data volume configuration file.

Warning

Cloning operations between different volume modes are supported, such as cloning from a persistent volume (PV) with volumeMode: Block to a PV with volumeMode: Filesystem.

However, you can only clone between different volume modes if they are of the contentType: kubevirt.

Tip

When you enable preallocation globally, or for a single data volume, the Containerized Data Importer (CDI) preallocates disk space during cloning. Preallocation enhances write performance. For more information, see Using preallocation for data volumes.

8.16.2.1. Prerequisites
8.16.2.2. About data volumes

DataVolume objects are custom resources that are provided by the Containerized Data Importer (CDI) project. Data volumes orchestrate import, clone, and upload operations that are associated with an underlying persistent volume claim (PVC). Data volumes are integrated with OpenShift Virtualization, and they prevent a virtual machine from being started before the PVC has been prepared.

8.16.2.3. Cloning the persistent volume claim of a virtual machine disk into a new data volume

You can clone a persistent volume claim (PVC) of an existing virtual machine disk into a new data volume. The new data volume can then be used for a new virtual machine.

Note

When a data volume is created independently of a virtual machine, the lifecycle of the data volume is independent of the virtual machine. If the virtual machine is deleted, neither the data volume nor its associated PVC is deleted.

Prerequisites

  • Determine the PVC of an existing virtual machine disk to use. You must power down the virtual machine that is associated with the PVC before you can clone it.
  • Install the OpenShift CLI (oc).

Procedure

  1. Examine the virtual machine disk you want to clone to identify the name and namespace of the associated PVC.
  2. Create a YAML file for a data volume that specifies the name of the new data volume, the name and namespace of the source PVC, and the size of the new data volume.

    For example:

    apiVersion: cdi.kubevirt.io/v1beta1
    kind: DataVolume
    metadata:
      name: <cloner-datavolume> 1
    spec:
      source:
        pvc:
          namespace: "<source-namespace>" 2
          name: "<my-favorite-vm-disk>" 3
      pvc:
        accessModes:
          - ReadWriteOnce
        resources:
          requests:
            storage: <2Gi> 4
    1
    The name of the new data volume.
    2
    The namespace where the source PVC exists.
    3
    The name of the source PVC.
    4
    The size of the new data volume. You must allocate enough space, or the cloning operation fails. The size must be the same as or larger than the source PVC.
  3. Start cloning the PVC by creating the data volume:

    $ oc create -f <cloner-datavolume>.yaml
    Note

    Data volumes prevent a virtual machine from starting before the PVC is prepared, so you can create a virtual machine that references the new data volume while the PVC clones.

8.16.2.4. CDI supported operations matrix

This matrix shows the supported CDI operations for content types against endpoints, and which of these operations requires scratch space.

Content typesHTTPHTTPSHTTP basic authRegistryUpload

KubeVirt (QCOW2)

✓ QCOW2
✓ GZ*
✓ XZ*

✓ QCOW2**
✓ GZ*
✓ XZ*

✓ QCOW2
✓ GZ*
✓ XZ*

✓ QCOW2*
□ GZ
□ XZ

✓ QCOW2*
✓ GZ*
✓ XZ*

KubeVirt (RAW)

✓ RAW
✓ GZ
✓ XZ

✓ RAW
✓ GZ
✓ XZ

✓ RAW
✓ GZ
✓ XZ

✓ RAW*
□ GZ
□ XZ

✓ RAW*
✓ GZ*
✓ XZ*

✓ Supported operation

□ Unsupported operation

* Requires scratch space

** Requires scratch space if a custom certificate authority is required

8.16.3. Cloning a virtual machine by using a data volume template

You can create a new virtual machine by cloning the persistent volume claim (PVC) of an existing VM. By including a dataVolumeTemplate in your virtual machine configuration file, you create a new data volume from the original PVC.

Warning

Cloning operations between different volume modes are supported, such as cloning from a persistent volume (PV) with volumeMode: Block to a PV with volumeMode: Filesystem.

However, you can only clone between different volume modes if they are of the contentType: kubevirt.

Tip

When you enable preallocation globally, or for a single data volume, the Containerized Data Importer (CDI) preallocates disk space during cloning. Preallocation enhances write performance. For more information, see Using preallocation for data volumes.

8.16.3.1. Prerequisites
8.16.3.2. About data volumes

DataVolume objects are custom resources that are provided by the Containerized Data Importer (CDI) project. Data volumes orchestrate import, clone, and upload operations that are associated with an underlying persistent volume claim (PVC). Data volumes are integrated with OpenShift Virtualization, and they prevent a virtual machine from being started before the PVC has been prepared.

8.16.3.3. Creating a new virtual machine from a cloned persistent volume claim by using a data volume template

You can create a virtual machine that clones the persistent volume claim (PVC) of an existing virtual machine into a data volume. Reference a dataVolumeTemplate in the virtual machine manifest and the source PVC is cloned to a data volume, which is then automatically used for the creation of the virtual machine.

Note

When a data volume is created as part of the data volume template of a virtual machine, the lifecycle of the data volume is then dependent on the virtual machine. If the virtual machine is deleted, the data volume and associated PVC are also deleted.

Prerequisites

  • Determine the PVC of an existing virtual machine disk to use. You must power down the virtual machine that is associated with the PVC before you can clone it.
  • Install the OpenShift CLI (oc).

Procedure

  1. Examine the virtual machine you want to clone to identify the name and namespace of the associated PVC.
  2. Create a YAML file for a VirtualMachine object. The following virtual machine example clones my-favorite-vm-disk, which is located in the source-namespace namespace. The 2Gi data volume called favorite-clone is created from my-favorite-vm-disk.

    For example:

    apiVersion: kubevirt.io/v1
    kind: VirtualMachine
    metadata:
      labels:
        kubevirt.io/vm: vm-dv-clone
      name: vm-dv-clone 1
    spec:
      running: false
      template:
        metadata:
          labels:
            kubevirt.io/vm: vm-dv-clone
        spec:
          domain:
            devices:
              disks:
              - disk:
                  bus: virtio
                name: root-disk
            resources:
              requests:
                memory: 64M
          volumes:
          - dataVolume:
              name: favorite-clone
            name: root-disk
      dataVolumeTemplates:
      - metadata:
          name: favorite-clone
        spec:
          storage:
            accessModes:
            - ReadWriteOnce
            resources:
              requests:
                storage: 2Gi
          source:
            pvc:
              namespace: "source-namespace"
              name: "my-favorite-vm-disk"
    1
    The virtual machine to create.
  3. Create the virtual machine with the PVC-cloned data volume:

    $ oc create -f <vm-clone-datavolumetemplate>.yaml
8.16.3.4. CDI supported operations matrix

This matrix shows the supported CDI operations for content types against endpoints, and which of these operations requires scratch space.

Content typesHTTPHTTPSHTTP basic authRegistryUpload

KubeVirt (QCOW2)

✓ QCOW2
✓ GZ*
✓ XZ*

✓ QCOW2**
✓ GZ*
✓ XZ*

✓ QCOW2
✓ GZ*
✓ XZ*

✓ QCOW2*
□ GZ
□ XZ

✓ QCOW2*
✓ GZ*
✓ XZ*

KubeVirt (RAW)

✓ RAW
✓ GZ
✓ XZ

✓ RAW
✓ GZ
✓ XZ

✓ RAW
✓ GZ
✓ XZ

✓ RAW*
□ GZ
□ XZ

✓ RAW*
✓ GZ*
✓ XZ*

✓ Supported operation

□ Unsupported operation

* Requires scratch space

** Requires scratch space if a custom certificate authority is required

8.16.4. Cloning a virtual machine disk into a new block storage data volume

You can clone the persistent volume claim (PVC) of a virtual machine disk into a new block data volume by referencing the source PVC in your data volume configuration file.

Warning

Cloning operations between different volume modes are supported, such as cloning from a persistent volume (PV) with volumeMode: Block to a PV with volumeMode: Filesystem.

However, you can only clone between different volume modes if they are of the contentType: kubevirt.

Tip

When you enable preallocation globally, or for a single data volume, the Containerized Data Importer (CDI) preallocates disk space during cloning. Preallocation enhances write performance. For more information, see Using preallocation for data volumes.

8.16.4.1. Prerequisites
8.16.4.2. About data volumes

DataVolume objects are custom resources that are provided by the Containerized Data Importer (CDI) project. Data volumes orchestrate import, clone, and upload operations that are associated with an underlying persistent volume claim (PVC). Data volumes are integrated with OpenShift Virtualization, and they prevent a virtual machine from being started before the PVC has been prepared.

8.16.4.3. About block persistent volumes

A block persistent volume (PV) is a PV that is backed by a raw block device. These volumes do not have a file system and can provide performance benefits for virtual machines by reducing overhead.

Raw block volumes are provisioned by specifying volumeMode: Block in the PV and persistent volume claim (PVC) specification.

8.16.4.4. Creating a local block persistent volume

Create a local block persistent volume (PV) on a node by populating a file and mounting it as a loop device. You can then reference this loop device in a PV manifest as a Block volume and use it as a block device for a virtual machine image.

Procedure

  1. Log in as root to the node on which to create the local PV. This procedure uses node01 for its examples.
  2. Create a file and populate it with null characters so that it can be used as a block device. The following example creates a file loop10 with a size of 2Gb (20 100Mb blocks):

    $ dd if=/dev/zero of=<loop10> bs=100M count=20
  3. Mount the loop10 file as a loop device.

    $ losetup </dev/loop10>d3 <loop10> 1 2
    1
    File path where the loop device is mounted.
    2
    The file created in the previous step to be mounted as the loop device.
  4. Create a PersistentVolume manifest that references the mounted loop device.

    kind: PersistentVolume
    apiVersion: v1
    metadata:
      name: <local-block-pv10>
      annotations:
    spec:
      local:
        path: </dev/loop10> 1
      capacity:
        storage: <2Gi>
      volumeMode: Block 2
      storageClassName: local 3
      accessModes:
        - ReadWriteOnce
      persistentVolumeReclaimPolicy: Delete
      nodeAffinity:
        required:
          nodeSelectorTerms:
          - matchExpressions:
            - key: kubernetes.io/hostname
              operator: In
              values:
              - <node01> 4
    1
    The path of the loop device on the node.
    2
    Specifies it is a block PV.
    3
    Optional: Set a storage class for the PV. If you omit it, the cluster default is used.
    4
    The node on which the block device was mounted.
  5. Create the block PV.

    # oc create -f <local-block-pv10.yaml>1
    1
    The file name of the persistent volume created in the previous step.
8.16.4.5. Cloning the persistent volume claim of a virtual machine disk into a new data volume

You can clone a persistent volume claim (PVC) of an existing virtual machine disk into a new data volume. The new data volume can then be used for a new virtual machine.

Note

When a data volume is created independently of a virtual machine, the lifecycle of the data volume is independent of the virtual machine. If the virtual machine is deleted, neither the data volume nor its associated PVC is deleted.

Prerequisites

  • Determine the PVC of an existing virtual machine disk to use. You must power down the virtual machine that is associated with the PVC before you can clone it.
  • Install the OpenShift CLI (oc).
  • At least one available block persistent volume (PV) that is the same size as or larger than the source PVC.

Procedure

  1. Examine the virtual machine disk you want to clone to identify the name and namespace of the associated PVC.
  2. Create a YAML file for a data volume that specifies the name of the new data volume, the name and namespace of the source PVC, volumeMode: Block so that an available block PV is used, and the size of the new data volume.

    For example:

    apiVersion: cdi.kubevirt.io/v1beta1
    kind: DataVolume
    metadata:
      name: <cloner-datavolume> 1
    spec:
      source:
        pvc:
          namespace: "<source-namespace>" 2
          name: "<my-favorite-vm-disk>" 3
      pvc:
        accessModes:
          - ReadWriteOnce
        resources:
          requests:
            storage: <2Gi> 4
        volumeMode: Block 5
    1
    The name of the new data volume.
    2
    The namespace where the source PVC exists.
    3
    The name of the source PVC.
    4
    The size of the new data volume. You must allocate enough space, or the cloning operation fails. The size must be the same as or larger than the source PVC.
    5
    Specifies that the destination is a block PV
  3. Start cloning the PVC by creating the data volume:

    $ oc create -f <cloner-datavolume>.yaml
    Note

    Data volumes prevent a virtual machine from starting before the PVC is prepared, so you can create a virtual machine that references the new data volume while the PVC clones.

8.16.4.6. CDI supported operations matrix

This matrix shows the supported CDI operations for content types against endpoints, and which of these operations requires scratch space.

Content typesHTTPHTTPSHTTP basic authRegistryUpload

KubeVirt (QCOW2)

✓ QCOW2
✓ GZ*
✓ XZ*

✓ QCOW2**
✓ GZ*
✓ XZ*

✓ QCOW2
✓ GZ*
✓ XZ*

✓ QCOW2*
□ GZ
□ XZ

✓ QCOW2*
✓ GZ*
✓ XZ*

KubeVirt (RAW)

✓ RAW
✓ GZ
✓ XZ

✓ RAW
✓ GZ
✓ XZ

✓ RAW
✓ GZ
✓ XZ

✓ RAW*
□ GZ
□ XZ

✓ RAW*
✓ GZ*
✓ XZ*

✓ Supported operation

□ Unsupported operation

* Requires scratch space

** Requires scratch space if a custom certificate authority is required

8.17. Virtual machine networking

8.17.1. Configuring the virtual machine for the default pod network

You can connect a virtual machine to the default internal pod network by configuring its network interface to use the masquerade binding mode

8.17.1.1. Configuring masquerade mode from the command line

You can use masquerade mode to hide a virtual machine’s outgoing traffic behind the pod IP address. Masquerade mode uses Network Address Translation (NAT) to connect virtual machines to the pod network backend through a Linux bridge.

Enable masquerade mode and allow traffic to enter the virtual machine by editing your virtual machine configuration file.

Prerequisites

  • The virtual machine must be configured to use DHCP to acquire IPv4 addresses. The examples below are configured to use DHCP.

Procedure

  1. Edit the interfaces spec of your virtual machine configuration file:

    kind: VirtualMachine
    spec:
      domain:
        devices:
          interfaces:
            - name: default
              masquerade: {} 1
              ports: 2
                - port: 80
      networks:
      - name: default
        pod: {}
    1
    Connect using masquerade mode.
    2
    Optional: List the ports that you want to expose from the virtual machine, each specified by the port field. The port value must be a number between 0 and 65536. When the ports array is not used, all ports in the valid range are open to incoming traffic. In this example, incoming traffic is allowed on port 80.
    Note

    Ports 49152 and 49153 are reserved for use by the libvirt platform and all other incoming traffic to these ports is dropped.

  2. Create the virtual machine:

    $ oc create -f <vm-name>.yaml
8.17.1.2. Configuring masquerade mode with dual-stack (IPv4 and IPv6)

You can configure a new virtual machine (VM) to use both IPv6 and IPv4 on the default pod network by using cloud-init.

The Network.pod.vmIPv6NetworkCIDR field in the virtual machine instance configuration determines the static IPv6 address of the VM and the gateway IP address. These are used by the virt-launcher pod to route IPv6 traffic to the virtual machine and are not used externally. The Network.pod.vmIPv6NetworkCIDR field specifies an IPv6 address block in Classless Inter-Domain Routing (CIDR) notation. The default value is fd10:0:2::2/120. You can edit this value based on your network requirements.

When the virtual machine is running, incoming and outgoing traffic for the virtual machine is routed to both the IPv4 address and the unique IPv6 address of the virt-launcher pod. The virt-launcher pod then routes the IPv4 traffic to the DHCP address of the virtual machine, and the IPv6 traffic to the statically set IPv6 address of the virtual machine.

Prerequisites

  • The OpenShift Container Platform cluster must use the OVN-Kubernetes Container Network Interface (CNI) network provider configured for dual-stack.

Procedure

  1. In a new virtual machine configuration, include an interface with masquerade and configure the IPv6 address and default gateway by using cloud-init.

    apiVersion: kubevirt.io/v1
    kind: VirtualMachine
    metadata:
      name: example-vm-ipv6
    ...
              interfaces:
                - name: default
                  masquerade: {} 1
                  ports:
                    - port: 80 2
          networks:
          - name: default
            pod: {}
          volumes:
          - cloudInitNoCloud:
              networkData: |
                version: 2
                ethernets:
                  eth0:
                    dhcp4: true
                    addresses: [ fd10:0:2::2/120 ] 3
                    gateway6: fd10:0:2::1 4
    1
    Connect using masquerade mode.
    2
    Allows incoming traffic on port 80 to the virtual machine.
    3
    The static IPv6 address as determined by the Network.pod.vmIPv6NetworkCIDR field in the virtual machine instance configuration. The default value is fd10:0:2::2/120.
    4
    The gateway IP address as determined by the Network.pod.vmIPv6NetworkCIDR field in the virtual machine instance configuration. The default value is fd10:0:2::1.
  2. Create the virtual machine in the namespace:

    $ oc create -f example-vm-ipv6.yaml

Verification

  • To verify that IPv6 has been configured, start the virtual machine and view the interface status of the virtual machine instance to ensure it has an IPv6 address:
$ oc get vmi <vmi-name> -o jsonpath="{.status.interfaces[*].ipAddresses}"

8.17.2. Creating a service to expose a virtual machine

You can expose a virtual machine within the cluster or outside the cluster by using a Service object.

8.17.2.1. About services

A Kubernetes service is an abstract way to expose an application running on a set of pods as a network service. Services allow your applications to receive traffic. Services can be exposed in different ways by specifying a spec.type in the Service object:

ClusterIP
Exposes the service on an internal IP address within the cluster. ClusterIP is the default service type.
NodePort
Exposes the service on the same port of each selected node in the cluster. NodePort makes a service accessible from outside the cluster.
LoadBalancer
Creates an external load balancer in the current cloud (if supported) and assigns a fixed, external IP address to the service.
8.17.2.1.1. Dual-stack support

If IPv4 and IPv6 dual-stack networking is enabled for your cluster, you can create a service that uses IPv4, IPv6, or both, by defining the spec.ipFamilyPolicy and the spec.ipFamilies fields in the Service object.

The spec.ipFamilyPolicy field can be set to one of the following values:

SingleStack
The control plane assigns a cluster IP address for the service based on the first configured service cluster IP range.
PreferDualStack
The control plane assigns both IPv4 and IPv6 cluster IP addresses for the service on clusters that have dual-stack configured.
RequireDualStack
This option fails for clusters that do not have dual-stack networking enabled. For clusters that have dual-stack configured, the behavior is the same as when the value is set to PreferDualStack. The control plane allocates cluster IP addresses from both IPv4 and IPv6 address ranges.

You can define which IP family to use for single-stack or define the order of IP families for dual-stack by setting the spec.ipFamilies field to one of the following array values:

  • [IPv4]
  • [IPv6]
  • [IPv4, IPv6]
  • [IPv6, IPv4]
8.17.2.2. Exposing a virtual machine as a service

Create a ClusterIP, NodePort, or LoadBalancer service to connect to a running virtual machine (VM) from within or outside the cluster.

Procedure

  1. Edit the VirtualMachine manifest to add the label for service creation:

    apiVersion: kubevirt.io/v1
    kind: VirtualMachine
    metadata:
      name: vm-ephemeral
      namespace: example-namespace
    spec:
      running: false
      template:
        metadata:
          labels:
            special: key 1
    # ...
    1
    Add the label special: key in the spec.template.metadata.labels section.
    Note

    Labels on a virtual machine are passed through to the pod. The special: key label must match the label in the spec.selector attribute of the Service manifest.

  2. Save the VirtualMachine manifest file to apply your changes.
  3. Create a Service manifest to expose the VM:

    apiVersion: v1
    kind: Service
    metadata:
      name: vmservice 1
      namespace: example-namespace 2
    spec:
      externalTrafficPolicy: Cluster 3
      ports:
      - nodePort: 30000 4
        port: 27017
        protocol: TCP
        targetPort: 22 5
      selector:
        special: key 6
      type: NodePort 7
    1
    The name of the Service object.
    2
    The namespace where the Service object resides. This must match the metadata.namespace field of the VirtualMachine manifest.
    3
    Optional: Specifies how the nodes distribute service traffic that is received on external IP addresses. This only applies to NodePort and LoadBalancer service types. The default value is Cluster which routes traffic evenly to all cluster endpoints.
    4
    Optional: When set, the nodePort value must be unique across all services. If not specified, a value in the range above 30000 is dynamically allocated.
    5
    Optional: The VM port to be exposed by the service. It must reference an open port if a port list is defined in the VM manifest. If targetPort is not specified, it takes the same value as port.
    6
    The reference to the label that you added in the spec.template.metadata.labels stanza of the VirtualMachine manifest.
    7
    The type of service. Possible values are ClusterIP, NodePort and LoadBalancer.
  4. Save the Service manifest file.
  5. Create the service by running the following command:

    $ oc create -f <service_name>.yaml
  6. Start the VM. If the VM is already running, restart it.

Verification

  1. Query the Service object to verify that it is available:

    $ oc get service -n example-namespace

    Example output for ClusterIP service

    NAME        TYPE        CLUSTER-IP     EXTERNAL-IP   PORT(S)     AGE
    vmservice   ClusterIP   172.30.3.149   <none>        27017/TCP   2m

    Example output for NodePort service

    NAME        TYPE        CLUSTER-IP     EXTERNAL-IP   PORT(S)            AGE
    vmservice   NodePort    172.30.232.73   <none>       27017:30000/TCP    5m

    Example output for LoadBalancer service

    NAME        TYPE            CLUSTER-IP     EXTERNAL-IP                    PORT(S)           AGE
    vmservice   LoadBalancer    172.30.27.5   172.29.10.235,172.29.10.235     27017:31829/TCP   5s

  2. Choose the appropriate method to connect to the virtual machine:

    • For a ClusterIP service, connect to the VM from within the cluster by using the service IP address and the service port. For example:

      $ ssh fedora@172.30.3.149 -p 27017
    • For a NodePort service, connect to the VM by specifying the node IP address and the node port outside the cluster network. For example:

      $ ssh fedora@$NODE_IP -p 30000
    • For a LoadBalancer service, use the vinagre client to connect to your virtual machine by using the public IP address and port. External ports are dynamically allocated.
8.17.2.3. Additional resources

8.17.3. Connecting a virtual machine to a Linux bridge network

You can attach virtual machines to multiple networks by using Linux bridges. You can also import virtual machines with existing workloads that depend on access to multiple interfaces.

To attach a virtual machine to an additional network:

  1. Configure a bridge network attachment definition for a namespace in the web console or CLI.

    Note

    The network attachment definition must be in the same namespace as the pod or virtual machine.

  2. Attach the virtual machine to the network attachment definition by using either the web console or the CLI:

    • In the web console, create a NIC for a new or existing virtual machine.
    • In the CLI, include the network information in the virtual machine configuration.
8.17.3.1. OpenShift Virtualization networking glossary

OpenShift Virtualization provides advanced networking functionality by using custom resources and plugins.

The following terms are used throughout OpenShift Virtualization documentation:

Container Network Interface (CNI)
a Cloud Native Computing Foundation project, focused on container network connectivity. OpenShift Virtualization uses CNI plugins to build upon the basic Kubernetes networking functionality.
Multus
a "meta" CNI plugin that allows multiple CNIs to exist so that a pod or virtual machine can use the interfaces it needs.
Custom resource definition (CRD)
a Kubernetes API resource that allows you to define custom resources, or an object defined by using the CRD API resource.
Network attachment definition
a CRD introduced by the Multus project that allows you to attach pods, virtual machines, and virtual machine instances to one or more networks.
Preboot eXecution Environment (PXE)
an interface that enables an administrator to boot a client machine from a server over the network. Network booting allows you to remotely load operating systems and other software onto the client.
8.17.3.2. Creating a network attachment definition
8.17.3.2.1. Prerequisites
  • A Linux bridge must be configured and attached on every node. See the node networking section for more information.
Warning

Configuring ipam in a network attachment definition for virtual machines is not supported.

8.17.3.2.2. Creating a Linux bridge network attachment definition in the web console

Network administrators can create network attachment definitions to provide layer-2 networking to pods and virtual machines.

Procedure

  1. In the web console, click NetworkingNetwork Attachment Definitions.
  2. Click Create Network Attachment Definition.

    Note

    The network attachment definition must be in the same namespace as the pod or virtual machine.

  3. Enter a unique Name and optional Description.
  4. Click the Network Type list and select CNV Linux bridge.
  5. Enter the name of the bridge in the Bridge Name field.
  6. Optional: If the resource has VLAN IDs configured, enter the ID numbers in the VLAN Tag Number field.
  7. Optional: Select MAC Spoof Check to enable MAC spoof filtering. This feature provides security against a MAC spoofing attack by allowing only a single MAC address to exit the pod.
  8. Click Create.

    Note

    A Linux bridge network attachment definition is the most efficient method for connecting a virtual machine to a VLAN.

8.17.3.2.3. Creating a Linux bridge network attachment definition in the CLI

As a network administrator, you can configure a network attachment definition of type cnv-bridge to provide layer-2 networking to pods and virtual machines.

Prerequisites

  • The node must support nftables and the nft binary must be deployed to enable MAC spoof check.

Procedure

  1. Create a network attachment definition in the same namespace as the virtual machine.
  2. Add the virtual machine to the network attachment definition, as in the following example:

    apiVersion: "k8s.cni.cncf.io/v1"
    kind: NetworkAttachmentDefinition
    metadata:
      name: <bridge-network> 1
      annotations:
        k8s.v1.cni.cncf.io/resourceName: bridge.network.kubevirt.io/<bridge-interface> 2
    spec:
      config: '{
        "cniVersion": "0.3.1",
        "name": "<bridge-network>", 3
        "type": "cnv-bridge", 4
        "bridge": "<bridge-interface>", 5
        "macspoofchk": true, 6
        "vlan": 1 7
      }'
    1
    The name for the NetworkAttachmentDefinition object.
    2
    Optional: Annotation key-value pair for node selection, where bridge-interface is the name of a bridge configured on some nodes. If you add this annotation to your network attachment definition, your virtual machine instances will only run on the nodes that have the bridge-interface bridge connected.
    3
    The name for the configuration. It is recommended to match the configuration name to the name value of the network attachment definition.
    4
    The actual name of the Container Network Interface (CNI) plugin that provides the network for this network attachment definition. Do not change this field unless you want to use a different CNI.
    5
    The name of the Linux bridge configured on the node.
    6
    Optional: Flag to enable MAC spoof check. When set to true, you cannot change the MAC address of the pod or guest interface. This attribute provides security against a MAC spoofing attack by allowing only a single MAC address to exit the pod.
    7
    Optional: The VLAN tag. No additional VLAN configuration is required on the node network configuration policy.
    Note

    A Linux bridge network attachment definition is the most efficient method for connecting a virtual machine to a VLAN.

  3. Create the network attachment definition:

    $ oc create -f <network-attachment-definition.yaml> 1
    1
    Where <network-attachment-definition.yaml> is the file name of the network attachment definition manifest.

Verification

  • Verify that the network attachment definition was created by running the following command:

    $ oc get network-attachment-definition <bridge-network>
8.17.3.3. Attaching the virtual machine to the additional network
8.17.3.3.1. Creating a NIC for a virtual machine in the web console

Create and attach additional NICs to a virtual machine from the web console.

Procedure

  1. In the correct project in the OpenShift Virtualization console, click WorkloadsVirtualization from the side menu.
  2. Click the Virtual Machines tab.
  3. Select a virtual machine to open the Virtual Machine Overview screen.
  4. Click Network Interfaces to display the NICs already attached to the virtual machine.
  5. Click Add Network Interface to create a new slot in the list.
  6. Use the Network drop-down list to select the network attachment definition for the additional network.
  7. Fill in the Name, Model, Type, and MAC Address for the new NIC.
  8. Click Add to save and attach the NIC to the virtual machine.
8.17.3.3.2. Networking fields
NameDescription

Name

Name for the network interface controller.

Model

Indicates the model of the network interface controller. Supported values are e1000e and virtio.

Network

List of available network attachment definitions.

Type

List of available binding methods. For the default pod network, masquerade is the only recommended binding method. For secondary networks, use the bridge binding method. The masquerade method is not supported for non-default networks. Select SR-IOV if you configured an SR-IOV network device and defined that network in the namespace.

MAC Address

MAC address for the network interface controller. If a MAC address is not specified, one is assigned automatically.

8.17.3.3.3. Attaching a virtual machine to an additional network in the CLI

Attach a virtual machine to an additional network by adding a bridge interface and specifying a network attachment definition in the virtual machine configuration.

This procedure uses a YAML file to demonstrate editing the configuration and applying the updated file to the cluster. You can alternatively use the oc edit <object> <name> command to edit an existing virtual machine.

Prerequisites

  • Shut down the virtual machine before editing the configuration. If you edit a running virtual machine, you must restart the virtual machine for the changes to take effect.

Procedure

  1. Create or edit a configuration of a virtual machine that you want to connect to the bridge network.
  2. Add the bridge interface to the spec.template.spec.domain.devices.interfaces list and the network attachment definition to the spec.template.spec.networks list. This example adds a bridge interface called bridge-net that connects to the a-bridge-network network attachment definition:

    apiVersion: kubevirt.io/v1
    kind: VirtualMachine
    metadata:
        name: <example-vm>
    spec:
      template:
        spec:
          domain:
            devices:
              interfaces:
                - masquerade: {}
                  name: <default>
                - bridge: {}
                  name: <bridge-net> 1
    ...
          networks:
            - name: <default>
              pod: {}
            - name: <bridge-net> 2
              multus:
                networkName: <network-namespace>/<a-bridge-network> 3
    ...
    1
    The name of the bridge interface.
    2
    The name of the network. This value must match the name value of the corresponding spec.template.spec.domain.devices.interfaces entry.
    3
    The name of the network attachment definition, prefixed by the namespace where it exists. The namespace must be either the default namespace or the same namespace where the VM is to be created. In this case, multus is used. Multus is a cloud network interface (CNI) plugin that allows multiple CNIs to exist so that a pod or virtual machine can use the interfaces it needs.
  3. Apply the configuration:

    $ oc apply -f <example-vm.yaml>
  4. Optional: If you edited a running virtual machine, you must restart it for the changes to take effect.
8.17.3.4. Additional resources

8.17.4. Connecting a virtual machine to an SR-IOV network

You can connect a virtual machine (VM) to a Single Root I/O Virtualization (SR-IOV) network by performing the following steps:

  1. Configure an SR-IOV network device.
  2. Configure an SR-IOV network.
  3. Connect the VM to the SR-IOV network.
8.17.4.1. Prerequisites
8.17.4.2. Configuring SR-IOV network devices

The SR-IOV Network Operator adds the SriovNetworkNodePolicy.sriovnetwork.openshift.io CustomResourceDefinition to OpenShift Container Platform. You can configure an SR-IOV network device by creating a SriovNetworkNodePolicy custom resource (CR).

Note

When applying the configuration specified in a SriovNetworkNodePolicy object, the SR-IOV Operator might drain the nodes, and in some cases, reboot nodes.

It might take several minutes for a configuration change to apply.

Prerequisites

  • You installed the OpenShift CLI (oc).
  • You have access to the cluster as a user with the cluster-admin role.
  • You have installed the SR-IOV Network Operator.
  • You have enough available nodes in your cluster to handle the evicted workload from drained nodes.
  • You have not selected any control plane nodes for SR-IOV network device configuration.

Procedure

  1. Create an SriovNetworkNodePolicy object, and then save the YAML in the <name>-sriov-node-network.yaml file. Replace <name> with the name for this configuration.

    apiVersion: sriovnetwork.openshift.io/v1
    kind: SriovNetworkNodePolicy
    metadata:
      name: <name> 1
      namespace: openshift-sriov-network-operator 2
    spec:
      resourceName: <sriov_resource_name> 3
      nodeSelector:
        feature.node.kubernetes.io/network-sriov.capable: "true" 4
      priority: <priority> 5
      mtu: <mtu> 6
      numVfs: <num> 7
      nicSelector: 8
        vendor: "<vendor_code>" 9
        deviceID: "<device_id>" 10
        pfNames: ["<pf_name>", ...] 11
        rootDevices: ["<pci_bus_id>", "..."] 12
      deviceType: vfio-pci 13
      isRdma: false 14
    1
    Specify a name for the CR object.
    2
    Specify the namespace where the SR-IOV Operator is installed.
    3
    Specify the resource name of the SR-IOV device plugin. You can create multiple SriovNetworkNodePolicy objects for a resource name.
    4
    Specify the node selector to select which nodes are configured. Only SR-IOV network devices on selected nodes are configured. The SR-IOV Container Network Interface (CNI) plugin and device plugin are deployed only on selected nodes.
    5
    Optional: Specify an integer value between 0 and 99. A smaller number gets higher priority, so a priority of 10 is higher than a priority of 99. The default value is 99.
    6
    Optional: Specify a value for the maximum transmission unit (MTU) of the virtual function. The maximum MTU value can vary for different NIC models.
    7
    Specify the number of the virtual functions (VF) to create for the SR-IOV physical network device. For an Intel network interface controller (NIC), the number of VFs cannot be larger than the total VFs supported by the device. For a Mellanox NIC, the number of VFs cannot be larger than 128.
    8
    The nicSelector mapping selects the Ethernet device for the Operator to configure. You do not need to specify values for all the parameters. It is recommended to identify the Ethernet adapter with enough precision to minimize the possibility of selecting an Ethernet device unintentionally. If you specify rootDevices, you must also specify a value for vendor, deviceID, or pfNames. If you specify both pfNames and rootDevices at the same time, ensure that they point to an identical device.
    9
    Optional: Specify the vendor hex code of the SR-IOV network device. The only allowed values are either 8086 or 15b3.
    10
    Optional: Specify the device hex code of SR-IOV network device. The only allowed values are 158b, 1015, 1017.
    11
    Optional: The parameter accepts an array of one or more physical function (PF) names for the Ethernet device.
    12
    The parameter accepts an array of one or more PCI bus addresses for the physical function of the Ethernet device. Provide the address in the following format: 0000:02:00.1.
    13
    The vfio-pci driver type is required for virtual functions in OpenShift Virtualization.
    14
    Optional: Specify whether to enable remote direct memory access (RDMA) mode. For a Mellanox card, set isRdma to false. The default value is false.
    Note

    If isRDMA flag is set to true, you can continue to use the RDMA enabled VF as a normal network device. A device can be used in either mode.

  2. Optional: Label the SR-IOV capable cluster nodes with SriovNetworkNodePolicy.Spec.NodeSelector if they are not already labeled. For more information about labeling nodes, see "Understanding how to update labels on nodes".
  3. Create the SriovNetworkNodePolicy object:

    $ oc create -f <name>-sriov-node-network.yaml

    where <name> specifies the name for this configuration.

    After applying the configuration update, all the pods in sriov-network-operator namespace transition to the Running status.

  4. To verify that the SR-IOV network device is configured, enter the following command. Replace <node_name> with the name of a node with the SR-IOV network device that you just configured.

    $ oc get sriovnetworknodestates -n openshift-sriov-network-operator <node_name> -o jsonpath='{.status.syncStatus}'
8.17.4.3. Configuring SR-IOV additional network

You can configure an additional network that uses SR-IOV hardware by creating an SriovNetwork object.

When you create an SriovNetwork object, the SR-IOV Network Operator automatically creates a NetworkAttachmentDefinition object.

Note

Do not modify or delete an SriovNetwork object if it is attached to pods or virtual machines in a running state.

Prerequisites

  • Install the OpenShift CLI (oc).
  • Log in as a user with cluster-admin privileges.

Procedure

  1. Create the following SriovNetwork object, and then save the YAML in the <name>-sriov-network.yaml file. Replace <name> with a name for this additional network.
apiVersion: sriovnetwork.openshift.io/v1
kind: SriovNetwork
metadata:
  name: <name> 1
  namespace: openshift-sriov-network-operator 2
spec:
  resourceName: <sriov_resource_name> 3
  networkNamespace: <target_namespace> 4
  vlan: <vlan> 5
  spoofChk: "<spoof_check>" 6
  linkState: <link_state> 7
  maxTxRate: <max_tx_rate> 8
  minTxRate: <min_rx_rate> 9
  vlanQoS: <vlan_qos> 10
  trust: "<trust_vf>" 11
  capabilities: <capabilities> 12
1
Replace <name> with a name for the object. The SR-IOV Network Operator creates a NetworkAttachmentDefinition object with same name.
2
Specify the namespace where the SR-IOV Network Operator is installed.
3
Replace <sriov_resource_name> with the value for the .spec.resourceName parameter from the SriovNetworkNodePolicy object that defines the SR-IOV hardware for this additional network.
4
Replace <target_namespace> with the target namespace for the SriovNetwork. Only pods or virtual machines in the target namespace can attach to the SriovNetwork.
5
Optional: Replace <vlan> with a Virtual LAN (VLAN) ID for the additional network. The integer value must be from 0 to 4095. The default value is 0.
6
Optional: Replace <spoof_check> with the spoof check mode of the VF. The allowed values are the strings "on" and "off".
Important

You must enclose the value you specify in quotes or the CR is rejected by the SR-IOV Network Operator.

7
Optional: Replace <link_state> with the link state of virtual function (VF). Allowed value are enable, disable and auto.
8
Optional: Replace <max_tx_rate> with a maximum transmission rate, in Mbps, for the VF.
9
Optional: Replace <min_tx_rate> with a minimum transmission rate, in Mbps, for the VF. This value should always be less than or equal to Maximum transmission rate.
Note

Intel NICs do not support the minTxRate parameter. For more information, see BZ#1772847.

10
Optional: Replace <vlan_qos> with an IEEE 802.1p priority level for the VF. The default value is 0.
11
Optional: Replace <trust_vf> with the trust mode of the VF. The allowed values are the strings "on" and "off".
Important

You must enclose the value you specify in quotes or the CR is rejected by the SR-IOV Network Operator.

12
Optional: Replace <capabilities> with the capabilities to configure for this network.
  1. To create the object, enter the following command. Replace <name> with a name for this additional network.

    $ oc create -f <name>-sriov-network.yaml
  2. Optional: To confirm that the NetworkAttachmentDefinition object associated with the SriovNetwork object that you created in the previous step exists, enter the following command. Replace <namespace> with the namespace you specified in the SriovNetwork object.

    $ oc get net-attach-def -n <namespace>
8.17.4.4. Connecting a virtual machine to an SR-IOV network

You can connect the virtual machine (VM) to the SR-IOV network by including the network details in the VM configuration.

Procedure

  1. Include the SR-IOV network details in the spec.domain.devices.interfaces and spec.networks of the VM configuration:

    kind: VirtualMachine
    ...
    spec:
      domain:
        devices:
          interfaces:
          - name: <default> 1
            masquerade: {} 2
          - name: <nic1> 3
            sriov: {}
      networks:
      - name: <default> 4
        pod: {}
      - name: <nic1> 5
        multus:
            networkName: <sriov-network> 6
    ...
    1
    A unique name for the interface that is connected to the pod network.
    2
    The masquerade binding to the default pod network.
    3
    A unique name for the SR-IOV interface.
    4
    The name of the pod network interface. This must be the same as the interfaces.name that you defined earlier.
    5
    The name of the SR-IOV interface. This must be the same as the interfaces.name that you defined earlier.
    6
    The name of the SR-IOV network attachment definition.
  2. Apply the virtual machine configuration:

    $ oc apply -f <vm-sriov.yaml> 1
    1
    The name of the virtual machine YAML file.

8.17.5. Configuring IP addresses for virtual machines

You can configure either dynamically or statically provisioned IP addresses for virtual machines.

Prerequisites

  • The virtual machine must connect to an external network.
  • You must have a DHCP server available on the additional network to configure a dynamic IP for the virtual machine.
8.17.5.1. Configuring an IP address for a new virtual machine using cloud-init

You can use cloud-init to configure an IP address when you create a virtual machine. The IP address can be dynamically or statically provisioned.

Procedure

  • Create a virtual machine configuration and include the cloud-init network details in the spec.volumes.cloudInitNoCloud.networkData field of the virtual machine configuration:

    1. To configure a dynamic IP, specify the interface name and the dhcp4 boolean:

      kind: VirtualMachine
      spec:
      ...
        volumes:
        - cloudInitNoCloud:
            networkData: |
              version: 2
              ethernets:
                eth1: 1
                  dhcp4: true 2
      1
      The interface name.
      2
      Uses DHCP to provision an IPv4 address.
    2. To configure a static IP, specify the interface name and the IP address:

      kind: VirtualMachine
      spec:
      ...
        volumes:
        - cloudInitNoCloud:
            networkData: |
              version: 2
              ethernets:
                eth1: 1
                  addresses:
                  - 10.10.10.14/24 2
      1
      The interface name.
      2
      The static IP address for the virtual machine.

8.17.6. Viewing the IP address of NICs on a virtual machine

You can view the IP address for a network interface controller (NIC) by using the web console or the oc client. The QEMU guest agent displays additional information about the virtual machine’s secondary networks.

8.17.6.1. Prerequisites
  • Install the QEMU guest agent on the virtual machine.
8.17.6.2. Viewing the IP address of a virtual machine interface in the CLI

The network interface configuration is included in the oc describe vmi <vmi_name> command.

You can also view the IP address information by running ip addr on the virtual machine, or by running oc get vmi <vmi_name> -o yaml.

Procedure

  • Use the oc describe command to display the virtual machine interface configuration:

    $ oc describe vmi <vmi_name>

    Example output

    ...
    Interfaces:
       Interface Name:  eth0
       Ip Address:      10.244.0.37/24
       Ip Addresses:
         10.244.0.37/24
         fe80::858:aff:fef4:25/64
       Mac:             0a:58:0a:f4:00:25
       Name:            default
       Interface Name:  v2
       Ip Address:      1.1.1.7/24
       Ip Addresses:
         1.1.1.7/24
         fe80::f4d9:70ff:fe13:9089/64
       Mac:             f6:d9:70:13:90:89
       Interface Name:  v1
       Ip Address:      1.1.1.1/24
       Ip Addresses:
         1.1.1.1/24
         1.1.1.2/24
         1.1.1.4/24
         2001:de7:0:f101::1/64
         2001:db8:0:f101::1/64
         fe80::1420:84ff:fe10:17aa/64
       Mac:             16:20:84:10:17:aa

8.17.6.3. Viewing the IP address of a virtual machine interface in the web console

The IP information displays in the Virtual Machine Overview screen for the virtual machine.

Procedure

  1. In the OpenShift Virtualization console, click WorkloadsVirtualization from the side menu.
  2. Click the Virtual Machines tab.
  3. Select a virtual machine name to open the Virtual Machine Overview screen.

The information for each attached NIC is displayed under IP Address.

8.17.7. Using a MAC address pool for virtual machines

The KubeMacPool component provides a MAC address pool service for virtual machine NICs in a namespace.

8.17.7.1. About KubeMacPool

KubeMacPool provides a MAC address pool per namespace and allocates MAC addresses for virtual machine NICs from the pool. This ensures that the NIC is assigned a unique MAC address that does not conflict with the MAC address of another virtual machine.

Virtual machine instances created from that virtual machine retain the assigned MAC address across reboots.

Note

KubeMacPool does not handle virtual machine instances created independently from a virtual machine.

KubeMacPool is enabled by default when you install OpenShift Virtualization. You can disable a MAC address pool for a namespace by adding the mutatevirtualmachines.kubemacpool.io=ignore label to the namespace. Re-enable KubeMacPool for the namespace by removing the label.

8.17.7.2. Disabling a MAC address pool for a namespace in the CLI

Disable a MAC address pool for virtual machines in a namespace by adding the mutatevirtualmachines.kubemacpool.io=ignore label to the namespace.

Procedure

  • Add the mutatevirtualmachines.kubemacpool.io=ignore label to the namespace. The following example disables KubeMacPool for two namespaces, <namespace1> and <namespace2>:

    $ oc label namespace <namespace1> <namespace2> mutatevirtualmachines.kubemacpool.io=ignore
8.17.7.3. Re-enabling a MAC address pool for a namespace in the CLI

If you disabled KubeMacPool for a namespace and want to re-enable it, remove the mutatevirtualmachines.kubemacpool.io=ignore label from the namespace.

Note

Earlier versions of OpenShift Virtualization used the label mutatevirtualmachines.kubemacpool.io=allocate to enable KubeMacPool for a namespace. This is still supported but redundant as KubeMacPool is now enabled by default.

Procedure

  • Remove the KubeMacPool label from the namespace. The following example re-enables KubeMacPool for two namespaces, <namespace1> and <namespace2>:

    $ oc label namespace <namespace1> <namespace2> mutatevirtualmachines.kubemacpool.io-

8.18. Virtual machine disks

8.18.1. Storage features

Use the following table to determine feature availability for local and shared persistent storage in OpenShift Virtualization.

8.18.1.1. OpenShift Virtualization storage feature matrix
Table 8.4. OpenShift Virtualization storage feature matrix
 Virtual machine live migrationHost-assisted virtual machine disk cloningStorage-assisted virtual machine disk cloningVirtual machine snapshots

OpenShift Container Storage: RBD block-mode volumes

Yes

Yes

Yes

Yes

OpenShift Virtualization hostpath provisioner

No

Yes

No

No

Other multi-node writable storage

Yes [1]

Yes

Yes [2]

Yes [2]

Other single-node writable storage

No

Yes

Yes [2]

Yes [2]

  1. PVCs must request a ReadWriteMany access mode.
  2. Storage provider must support both Kubernetes and CSI snapshot APIs
Note

You cannot live migrate virtual machines that use:

  • A storage class with ReadWriteOnce (RWO) access mode
  • Passthrough features such as GPUs or SR-IOV network interfaces that have the sriovLiveMigration feature gate disabled

Do not set the evictionStrategy field to LiveMigrate for these virtual machines.

8.18.2. Configuring local storage for virtual machines

You can configure local storage for your virtual machines by using the hostpath provisioner feature.

8.18.2.1. About the hostpath provisioner

The hostpath provisioner is a local storage provisioner designed for OpenShift Virtualization. If you want to configure local storage for virtual machines, you must enable the hostpath provisioner first.

When you install the OpenShift Virtualization Operator, the hostpath provisioner Operator is automatically installed. To use it, you must:

  • Configure SELinux:

    • If you use Red Hat Enterprise Linux CoreOS (RHCOS) 8 workers, you must create a MachineConfig object on each node.
    • Otherwise, apply the SELinux label container_file_t to the persistent volume (PV) backing directory on each node.
  • Create a HostPathProvisioner custom resource.
  • Create a StorageClass object for the hostpath provisioner.

The hostpath provisioner Operator deploys the provisioner as a DaemonSet on each node when you create its custom resource. In the custom resource file, you specify the backing directory for the persistent volumes that the hostpath provisioner creates.

8.18.2.2. Configuring SELinux for the hostpath provisioner on Red Hat Enterprise Linux CoreOS (RHCOS) 8

You must configure SELinux before you create the HostPathProvisioner custom resource. To configure SELinux on Red Hat Enterprise Linux CoreOS (RHCOS) 8 workers, you must create a MachineConfig object on each node.

Prerequisites

  • Create a backing directory on each node for the persistent volumes (PVs) that the hostpath provisioner creates.

    Important

    The backing directory must not be located in the filesystem’s root directory because the / partition is read-only on RHCOS. For example, you can use /var/<directory_name> but not /<directory_name>.

    Warning

    If you select a directory that shares space with your operating system, you might exhaust the space on that partition and your node might become non-functional. Create a separate partition and point the hostpath provisioner to the separate partition to avoid interference with your operating system.

Procedure

  1. Create the MachineConfig file. For example:

    $ touch machineconfig.yaml
  2. Edit the file, ensuring that you include the directory where you want the hostpath provisioner to create PVs. For example:

    apiVersion: machineconfiguration.openshift.io/v1
    kind: MachineConfig
    metadata:
      name: 50-set-selinux-for-hostpath-provisioner
      labels:
        machineconfiguration.openshift.io/role: worker
    spec:
      config:
        ignition:
          version: 3.2.0
        systemd:
          units:
            - contents: |
                [Unit]
                Description=Set SELinux chcon for hostpath provisioner
                Before=kubelet.service
    
                [Service]
                ExecStart=/usr/bin/chcon -Rt container_file_t <backing_directory_path> 1
    
                [Install]
                WantedBy=multi-user.target
              enabled: true
              name: hostpath-provisioner.service
    1
    Specify the backing directory where you want the provisioner to create PVs. This directory must not be located in the filesystem’s root directory (/).
  3. Create the MachineConfig object:

    $ oc create -f machineconfig.yaml -n <namespace>
8.18.2.3. Using the hostpath provisioner to enable local storage

To deploy the hostpath provisioner and enable your virtual machines to use local storage, first create a HostPathProvisioner custom resource.

Prerequisites

  • Create a backing directory on each node for the persistent volumes (PVs) that the hostpath provisioner creates.

    Important

    The backing directory must not be located in the filesystem’s root directory because the / partition is read-only on Red Hat Enterprise Linux CoreOS (RHCOS). For example, you can use /var/<directory_name> but not /<directory_name>.

    Warning

    If you select a directory that shares space with your operating system, you might exhaust the space on that partition and your node becomes non-functional. Create a separate partition and point the hostpath provisioner to the separate partition to avoid interference with your operating system.

  • Apply the SELinux context container_file_t to the PV backing directory on each node. For example:

    $ sudo chcon -t container_file_t -R <backing_directory_path>
    Note

    If you use Red Hat Enterprise Linux CoreOS (RHCOS) 8 workers, you must configure SELinux by using a MachineConfig manifest instead.

Procedure

  1. Create the HostPathProvisioner custom resource file. For example:

    $ touch hostpathprovisioner_cr.yaml
  2. Edit the file, ensuring that the spec.pathConfig.path value is the directory where you want the hostpath provisioner to create PVs. For example:

    apiVersion: hostpathprovisioner.kubevirt.io/v1beta1
    kind: HostPathProvisioner
    metadata:
      name: hostpath-provisioner
    spec:
      imagePullPolicy: IfNotPresent
      pathConfig:
        path: "<backing_directory_path>" 1
        useNamingPrefix: false 2
      workload: 3
    1
    Specify the backing directory where you want the provisioner to create PVs. This directory must not be located in the filesystem’s root directory (/).
    2
    Change this value to true if you want to use the name of the persistent volume claim (PVC) that is bound to the created PV as the prefix of the directory name.
    3
    Optional: You can use the spec.workload field to configure node placement rules for the hostpath provisioner.
    Note

    If you did not create the backing directory, the provisioner attempts to create it for you. If you did not apply the container_file_t SELinux context, this can cause Permission denied errors.

  3. Create the custom resource in the openshift-cnv namespace:

    $ oc create -f hostpathprovisioner_cr.yaml -n openshift-cnv
8.18.2.4. Creating a storage class

When you create a storage class, you set parameters that affect the dynamic provisioning of persistent volumes (PVs) that belong to that storage class. You cannot update a StorageClass object’s parameters after you create it.

Important

When using OpenShift Virtualization with OpenShift Container Platform Container Storage, specify RBD block mode persistent volume claims (PVCs) when creating virtual machine disks. With virtual machine disks, RBD block mode volumes are more efficient and provide better performance than Ceph FS or RBD filesystem-mode PVCs.

To specify RBD block mode PVCs, use the 'ocs-storagecluster-ceph-rbd' storage class and VolumeMode: Block.

Procedure

  1. Create a YAML file for defining the storage class. For example:

    $ touch storageclass.yaml
  2. Edit the file. For example:

    apiVersion: storage.k8s.io/v1
    kind: StorageClass
    metadata:
      name: hostpath-provisioner 1
    provisioner: kubevirt.io/hostpath-provisioner
    reclaimPolicy: Delete 2
    volumeBindingMode: WaitForFirstConsumer 3
    1
    You can optionally rename the storage class by changing this value.
    2
    The two possible reclaimPolicy values are Delete and Retain. If you do not specify a value, the storage class defaults to Delete.
    3
    The volumeBindingMode value determines when dynamic provisioning and volume binding occur. Specify WaitForFirstConsumer to delay the binding and provisioning of a PV until after a pod that uses the persistent volume claim (PVC) is created. This ensures that the PV meets the pod’s scheduling requirements.
    Note

    Virtual machines use data volumes that are based on local PVs. Local PVs are bound to specific nodes. While the disk image is prepared for consumption by the virtual machine, it is possible that the virtual machine cannot be scheduled to the node where the local storage PV was previously pinned.

    To solve this problem, use the Kubernetes pod scheduler to bind the PVC to a PV on the correct node. By using StorageClass with volumeBindingMode set to WaitForFirstConsumer, the binding and provisioning of the PV is delayed until a Pod is created using the PVC.

  3. Create the StorageClass object:

    $ oc create -f storageclass.yaml

Additional resources

8.18.3. Creating data volumes

When you create a data volume, the Containerized Data Importer (CDI) creates a persistent volume claim (PVC) and populates the PVC with your data. You can create a data volume as either a standalone resource or by using a dataVolumeTemplate resource in a virtual machine specification. You create a data volume by using either the PVC API or storage APIs.

Important

When using OpenShift Virtualization with OpenShift Container Platform Container Storage, specify RBD block mode persistent volume claims (PVCs) when creating virtual machine disks. With virtual machine disks, RBD block mode volumes are more efficient and provide better performance than Ceph FS or RBD filesystem-mode PVCs.

To specify RBD block mode PVCs, use the 'ocs-storagecluster-ceph-rbd' storage class and VolumeMode: Block.

Tip

Whenever possible, use the storage API to optimize space allocation and maximize performance.

A storage profile is a custom resource that the CDI manages. It provides recommended storage settings based on the associated storage class. A storage profile is allocated for each storage class.

Storage profiles enable you to create data volumes quickly while reducing coding and minimizing potential errors.

For recognized storage types, the CDI provides values that optimize the creation of PVCs. However, you can configure automatic settings for a storage class if you customize the storage profile.

8.18.3.1. Creating data volumes using the storage API

When you create a data volume using the storage API, the Containerized Data Interface (CDI) optimizes your persistent volume claim (PVC) allocation based on the type of storage supported by your selected storage class. You only have to specify the data volume name, namespace, and the amount of storage that you want to allocate.

For example:

  • When using Ceph RBD, accessModes is automatically set to ReadWriteMany, which enables live migration. volumeMode is set to Block to maximize performance.
  • When you are using volumeMode: Filesystem, more space will automatically be requested by the CDI, if required to accommodate file system overhead.

In the following YAML, using the storage API requests a data volume with two gigabytes of usable space. The user does not need to know the volumeMode in order to correctly estimate the required persistent volume claim (PVC) size. The CDI chooses the optimal combination of accessModes and volumeMode attributes automatically. These optimal values are based on the type of storage or the defaults that you define in your storage profile. If you want to provide custom values, they override the system-calculated values.

Example DataVolume definition

apiVersion: cdi.kubevirt.io/v1beta1
kind: DataVolume
metadata:
  name: <datavolume> 1
spec:
  source:
    pvc: 2
      namespace: "<source_namespace>" 3
      name: "<my_vm_disk>" 4
  storage: 5
    resources:
      requests:
        storage: 2Gi 6
    storageClassName: <storage_class> 7

1
The name of the new data volume.
2
Indicate that the source of the import is an existing persistent volume claim (PVC).
3
The namespace where the source PVC exists.
4
The name of the source PVC.
5
Indicates allocation using the storage API.
6
Specifies the amount of available space that you request for the PVC.
7
Optional: The name of the storage class. If the storage class is not specified, the system default storage class is used.
8.18.3.2. Creating data volumes using the PVC API

When you create a data volume using the PVC API, the Containerized Data Interface (CDI) creates the data volume based on what you specify for the following fields:

  • accessModes (ReadWriteOnce, ReadWriteMany, or ReadOnlyMany)
  • volumeMode (Filesystem or Block)
  • capacity of storage (5Gi, for example)

In the following YAML, using the PVC API allocates a data volume with a storage capacity of two gigabytes. You specify an access mode of ReadWriteMany to enable live migration. Because you know the values your system can support, you specify Block storage instead of the default, Filesystem.

Example DataVolume definition

apiVersion: cdi.kubevirt.io/v1beta1
kind: DataVolume
metadata:
  name: <datavolume> 1
spec:
  source:
    pvc: 2
      namespace: "<source_namespace>" 3
      name: "<my_vm_disk>" 4
  pvc: 5
    accessModes: 6
      - ReadWriteMany
    resources:
      requests:
        storage: 2Gi 7
    volumeMode: Block 8
    storageClassName: <storage_class> 9

1
The name of the new data volume.
2
In the source section, pvc indicates that the source of the import is an existing persistent volume claim (PVC).
3
The namespace where the source PVC exists.
4
The name of the source PVC.
5
Indicates allocation using the PVC API.
6
accessModes is required when using the PVC API.
7
Specifies the amount of space you are requesting for your data volume.
8
Specifies that the destination is a block PVC.
9
Optionally, specify the storage class. If the storage class is not specified, the system default storage class is used.
Important

When you explicitly allocate a data volume by using the PVC API and you are not using volumeMode: Block, consider file system overhead.

File system overhead is the amount of space required by the file system to maintain its metadata. The amount of space required for file system metadata is file system dependent. Failing to account for file system overhead in your storage capacity request can result in an underlying persistent volume claim (PVC) that is not large enough to accommodate your virtual machine disk.

If you use the storage API, the CDI will factor in file system overhead and request a larger persistent volume claim (PVC) to ensure that your allocation request is successful.

8.18.3.3. Customizing the storage profile

You can specify default parameters by editing the StorageProfile object for the provisioner’s storage class. These default parameters only apply to the persistent volume claim (PVC) if they are not configured in the DataVolume object.

Prerequisites

  • Ensure that your planned configuration is supported by the storage class and its provider. Specifying an incompatible configuration in a storage profile causes volume provisioning to fail.
Note

An empty status section in a storage profile indicates that a storage provisioner is not recognized by the Containerized Data Interface (CDI). Customizing a storage profile is necessary if you have a storage provisioner that is not recognized by the CDI. In this case, the administrator sets appropriate values in the storage profile to ensure successful allocations.

Warning

If you create a data volume and omit YAML attributes and these attributes are not defined in the storage profile, then the requested storage will not be allocated and the underlying persistent volume claim (PVC) will not be created.

Procedure

  1. Edit the storage profile. In this example, the provisioner is not recognized by CDI:

    $ oc edit -n openshift-cnv storageprofile <storage_class>

    Example storage profile

    apiVersion: cdi.kubevirt.io/v1beta1
    kind: StorageProfile
    metadata:
      name: <unknown_provisioner_class>
    #   ...
    spec: {}
    status:
      provisioner: <unknown_provisioner>
      storageClass: <unknown_provisioner_class>

  2. Provide the needed attribute values in the storage profile:

    Example storage profile

    apiVersion: cdi.kubevirt.io/v1beta1
    kind: StorageProfile
    metadata:
      name: <unknown_provisioner_class>
    #   ...
    spec:
      claimPropertySets:
      - accessModes:
        - ReadWriteOnce 1
        volumeMode:
          Filesystem 2
    status:
      provisioner: <unknown_provisioner>
      storageClass: <unknown_provisioner_class>

    1
    The accessModes that you select.
    2
    The volumeMode that you select.

    After you save your changes, the selected values appear in the storage profile status element.

8.18.3.3.1. Setting a default cloning strategy using a storage profile

You can use storage profiles to set a default cloning method for a storage class, creating a cloning strategy. Setting cloning strategies can be helpful, for example, if your storage vendor only supports certain cloning methods. It also allows you to select a method that limits resource usage or maximizes performance.

Cloning strategies can be specified by setting the cloneStrategy attribute in a storage profile to one of these values:

  • snapshot - This method is used by default when snapshots are configured. This cloning strategy uses a temporary volume snapshot to clone the volume. The storage provisioner must support CSI snapshots.
  • copy - This method uses a source pod and a target pod to copy data from the source volume to the target volume. Host-assisted cloning is the least efficient method of cloning.
  • csi-clone - This method uses the CSI clone API to efficiently clone an existing volume without using an interim volume snapshot. Unlike snapshot or copy, which are used by default if no storage profile is defined, CSI volume cloning is only used when you specify it in the StorageProfile object for the provisioner’s storage class.
Note

You can also set clone strategies using the CLI without modifying the default claimPropertySets in your YAML spec section.

Example storage profile

apiVersion: cdi.kubevirt.io/v1beta1
kind: StorageProfile
metadata:
  name: <provisioner_class>
#   ...
spec:
  claimPropertySets:
  - accessModes:
    - ReadWriteOnce 1
    volumeMode:
      Filesystem 2
  cloneStrategy:
  csi-clone 3
status:
  provisioner: <provisioner>
  storageClass: <provisioner_class>

1
The accessModes that you select.
2
The volumeMode that you select.
3
The default cloning method of your choice. In this example, CSI volume cloning is specified.
8.18.3.4. Additional resources

8.18.4. Configuring CDI to work with namespaces that have a compute resource quota

You can use the Containerized Data Importer (CDI) to import, upload, and clone virtual machine disks into namespaces that are subject to CPU and memory resource restrictions.

8.18.4.1. About CPU and memory quotas in a namespace

A resource quota, defined by the ResourceQuota object, imposes restrictions on a namespace that limit the total amount of compute resources that can be consumed by resources within that namespace.

The HyperConverged custom resource (CR) defines the user configuration for the Containerized Data Importer (CDI). The CPU and memory request and limit values are set to a default value of 0. This ensures that pods created by CDI that do not specify compute resource requirements are given the default values and are allowed to run in a namespace that is restricted with a quota.

8.18.4.2. Overriding CPU and memory defaults

Modify the default settings for CPU and memory requests and limits for your use case by adding the spec.resourceRequirements.storageWorkloads stanza to the HyperConverged custom resource (CR).

Prerequisites

  • Install the OpenShift CLI (oc).

Procedure

  1. Edit the HyperConverged CR by running the following command:

    $ oc edit hco -n openshift-cnv kubevirt-hyperconverged
  2. Add the spec.resourceRequirements.storageWorkloads stanza to the CR, setting the values based on your use case. For example:

    apiVersion: hco.kubevirt.io/v1beta1
    kind: HyperConverged
    metadata:
      name: kubevirt-hyperconverged
    spec:
      resourceRequirements:
        storageWorkloads:
          limits:
            cpu: "500m"
            memory: "2Gi"
          requests:
            cpu: "250m"
            memory: "1Gi"
  3. Save and exit the editor to update the HyperConverged CR.
8.18.4.3. Additional resources

8.18.5. Managing data volume annotations

Data volume (DV) annotations allow you to manage pod behavior. You can add one or more annotations to a data volume, which then propagates to the created importer pods.

8.18.5.1. Example: Data volume annotations

This example shows how you can configure data volume (DV) annotations to control which network the importer pod uses. The v1.multus-cni.io/default-network: bridge-network annotation causes the pod to use the multus network named bridge-network as its default network. If you want the importer pod to use both the default network from the cluster and the secondary multus network, use the k8s.v1.cni.cncf.io/networks: <network_name> annotation.

Multus network annotation example

apiVersion: cdi.kubevirt.io/v1beta1
kind: DataVolume
metadata:
  name: dv-ann
  annotations:
      v1.multus-cni.io/default-network: bridge-network 1
spec:
  source:
      http:
         url: "example.exampleurl.com"
  pvc:
    accessModes:
      - ReadWriteOnce
    resources:
      requests:
        storage: 1Gi

1
Multus network annotation

8.18.6. Using preallocation for data volumes

The Containerized Data Importer can preallocate disk space to improve write performance when creating data volumes.

You can enable preallocation for specific data volumes.

8.18.6.1. About preallocation

The Containerized Data Importer (CDI) can use the QEMU preallocate mode for data volumes to improve write performance. You can use preallocation mode for importing and uploading operations and when creating blank data volumes.

If preallocation is enabled, CDI uses the better preallocation method depending on the underlying file system and device type:

fallocate
If the file system supports it, CDI uses the operating system’s fallocate call to preallocate space by using the posix_fallocate function, which allocates blocks and marks them as uninitialized.
full
If fallocate mode cannot be used, full mode allocates space for the image by writing data to the underlying storage. Depending on the storage location, all the empty allocated space might be zeroed.
8.18.6.2. Enabling preallocation for a data volume

You can enable preallocation for specific data volumes by including the spec.preallocation field in the data volume manifest. You can enable preallocation mode in either the web console or by using the OpenShift CLI (oc).

Preallocation mode is supported for all CDI source types.

Procedure

  • Specify the spec.preallocation field in the data volume manifest:

    apiVersion: cdi.kubevirt.io/v1beta1
    kind: DataVolume
    metadata:
      name: preallocated-datavolume
    spec:
      source: 1
        ...
      pvc:
        ...
      preallocation: true 2
    1
    All CDI source types support preallocation, however preallocation is ignored for cloning operations.
    2
    The preallocation field is a boolean that defaults to false.

8.18.7. Uploading local disk images by using the web console

You can upload a locally stored disk image file by using the web console.

8.18.7.1. Prerequisites
8.18.7.2. CDI supported operations matrix

This matrix shows the supported CDI operations for content types against endpoints, and which of these operations requires scratch space.

Content typesHTTPHTTPSHTTP basic authRegistryUpload

KubeVirt (QCOW2)

✓ QCOW2
✓ GZ*
✓ XZ*

✓ QCOW2**
✓ GZ*
✓ XZ*

✓ QCOW2
✓ GZ*
✓ XZ*

✓ QCOW2*
□ GZ
□ XZ

✓ QCOW2*
✓ GZ*
✓ XZ*

KubeVirt (RAW)

✓ RAW
✓ GZ
✓ XZ

✓ RAW
✓ GZ
✓ XZ

✓ RAW
✓ GZ
✓ XZ

✓ RAW*
□ GZ
□ XZ

✓ RAW*
✓ GZ*
✓ XZ*

✓ Supported operation

□ Unsupported operation

* Requires scratch space

** Requires scratch space if a custom certificate authority is required

8.18.7.3. Uploading an image file using the web console

Use the web console to upload an image file to a new persistent volume claim (PVC). You can later use this PVC to attach the image to new virtual machines.

Prerequisites

  • You must have one of the following:

    • A raw virtual machine image file in either ISO or IMG format.
    • A virtual machine image file in QCOW2 format.
  • For best results, compress your image file according to the following guidelines before you upload it:

    • Compress a raw image file by using xz or gzip.

      Note

      Using a compressed raw image file results in the most efficient upload.

    • Compress a QCOW2 image file by using the method that is recommended for your client:

      • If you use a Linux client, sparsify the QCOW2 file by using the virt-sparsify tool.
      • If you use a Windows client, compress the QCOW2 file by using xz or gzip.

Procedure

  1. From the side menu of the web console, click StoragePersistent Volume Claims.
  2. Click the Create Persistent Volume Claim drop-down list to expand it.
  3. Click With Data Upload Form to open the Upload Data to Persistent Volume Claim page.
  4. Click Browse to open the file manager and select the image that you want to upload, or drag the file into the Drag a file here or browse to upload field.
  5. Optional: Set this image as the default image for a specific operating system.

    1. Select the Attach this data to a virtual machine operating system check box.
    2. Select an operating system from the list.
  6. The Persistent Volume Claim Name field is automatically filled with a unique name and cannot be edited. Take note of the name assigned to the PVC so that you can identify it later, if necessary.
  7. Select a storage class from the Storage Class list.
  8. In the Size field, enter the size value for the PVC. Select the corresponding unit of measurement from the drop-down list.

    Warning

    The PVC size must be larger than the size of the uncompressed virtual disk.

  9. Select an Access Mode that matches the storage class that you selected.
  10. Click Upload.
8.18.7.4. Additional resources

8.18.8. Uploading local disk images by using the virtctl tool

You can upload a locally stored disk image to a new or existing data volume by using the virtctl command-line utility.

8.18.8.1. Prerequisites
8.18.8.2. About data volumes

DataVolume objects are custom resources that are provided by the Containerized Data Importer (CDI) project. Data volumes orchestrate import, clone, and upload operations that are associated with an underlying persistent volume claim (PVC). Data volumes are integrated with OpenShift Virtualization, and they prevent a virtual machine from being started before the PVC has been prepared.

8.18.8.3. Creating an upload data volume

You can manually create a data volume with an upload data source to use for uploading local disk images.

Procedure

  1. Create a data volume configuration that specifies spec: source: upload{}:

    apiVersion: cdi.kubevirt.io/v1beta1
    kind: DataVolume
    metadata:
      name: <upload-datavolume> 1
    spec:
      source:
          upload: {}
      pvc:
        accessModes:
          - ReadWriteOnce
        resources:
          requests:
            storage: <2Gi> 2
    1
    The name of the data volume.
    2
    The size of the data volume. Ensure that this value is greater than or equal to the size of the disk that you upload.
  2. Create the data volume by running the following command:

    $ oc create -f <upload-datavolume>.yaml
8.18.8.4. Uploading a local disk image to a data volume

You can use the virtctl CLI utility to upload a local disk image from a client machine to a data volume (DV) in your cluster. You can use a DV that already exists in your cluster or create a new DV during this procedure.

Note

After you upload a local disk image, you can add it to a virtual machine.

Prerequisites

  • You must have one of the following:

    • A raw virtual machine image file in either ISO or IMG format.
    • A virtual machine image file in QCOW2 format.
  • For best results, compress your image file according to the following guidelines before you upload it:

    • Compress a raw image file by using xz or gzip.

      Note

      Using a compressed raw image file results in the most efficient upload.

    • Compress a QCOW2 image file by using the method that is recommended for your client:

      • If you use a Linux client, sparsify the QCOW2 file by using the virt-sparsify tool.
      • If you use a Windows client, compress the QCOW2 file by using xz or gzip.
  • The kubevirt-virtctl package must be installed on the client machine.
  • The client machine must be configured to trust the OpenShift Container Platform router’s certificate.

Procedure

  1. Identify the following items:

    • The name of the upload data volume that you want to use. If this data volume does not exist, it is created automatically.
    • The size of the data volume, if you want it to be created during the upload procedure. The size must be greater than or equal to the size of the disk image.
    • The file location of the virtual machine disk image that you want to upload.
  2. Upload the disk image by running the virtctl image-upload command. Specify the parameters that you identified in the previous step. For example:

    $ virtctl image-upload dv <datavolume_name> \ 1
    --size=<datavolume_size> \ 2
    --image-path=</path/to/image> \ 3
    1
    The name of the data volume.
    2
    The size of the data volume. For example: --size=500Mi, --size=1G
    3
    The file path of the virtual machine disk image.
    Note
    • If you do not want to create a new data volume, omit the --size parameter and include the --no-create flag.
    • When uploading a disk image to a PVC, the PVC size must be larger than the size of the uncompressed virtual disk.
    • To allow insecure server connections when using HTTPS, use the --insecure parameter. Be aware that when you use the --insecure flag, the authenticity of the upload endpoint is not verified.
  3. Optional. To verify that a data volume was created, view all data volumes by running the following command:

    $ oc get dvs
8.18.8.5. CDI supported operations matrix

This matrix shows the supported CDI operations for content types against endpoints, and which of these operations requires scratch space.

Content typesHTTPHTTPSHTTP basic authRegistryUpload

KubeVirt (QCOW2)

✓ QCOW2
✓ GZ*
✓ XZ*

✓ QCOW2**
✓ GZ*
✓ XZ*

✓ QCOW2
✓ GZ*
✓ XZ*

✓ QCOW2*
□ GZ
□ XZ

✓ QCOW2*
✓ GZ*
✓ XZ*

KubeVirt (RAW)

✓ RAW
✓ GZ
✓ XZ

✓ RAW
✓ GZ
✓ XZ

✓ RAW
✓ GZ
✓ XZ

✓ RAW*
□ GZ
□ XZ

✓ RAW*
✓ GZ*
✓ XZ*

✓ Supported operation

□ Unsupported operation

* Requires scratch space

** Requires scratch space if a custom certificate authority is required

8.18.8.6. Additional resources

8.18.9. Uploading a local disk image to a block storage data volume

You can upload a local disk image into a block data volume by using the virtctl command-line utility.

In this workflow, you create a local block device to use as a persistent volume, associate this block volume with an upload data volume, and use virtctl to upload the local disk image into the data volume.

8.18.9.1. Prerequisites
8.18.9.2. About data volumes

DataVolume objects are custom resources that are provided by the Containerized Data Importer (CDI) project. Data volumes orchestrate import, clone, and upload operations that are associated with an underlying persistent volume claim (PVC). Data volumes are integrated with OpenShift Virtualization, and they prevent a virtual machine from being started before the PVC has been prepared.

8.18.9.3. About block persistent volumes

A block persistent volume (PV) is a PV that is backed by a raw block device. These volumes do not have a file system and can provide performance benefits for virtual machines by reducing overhead.

Raw block volumes are provisioned by specifying volumeMode: Block in the PV and persistent volume claim (PVC) specification.

8.18.9.4. Creating a local block persistent volume

Create a local block persistent volume (PV) on a node by populating a file and mounting it as a loop device. You can then reference this loop device in a PV manifest as a Block volume and use it as a block device for a virtual machine image.

Procedure

  1. Log in as root to the node on which to create the local PV. This procedure uses node01 for its examples.
  2. Create a file and populate it with null characters so that it can be used as a block device. The following example creates a file loop10 with a size of 2Gb (20 100Mb blocks):

    $ dd if=/dev/zero of=<loop10> bs=100M count=20
  3. Mount the loop10 file as a loop device.

    $ losetup </dev/loop10>d3 <loop10> 1 2
    1
    File path where the loop device is mounted.
    2
    The file created in the previous step to be mounted as the loop device.
  4. Create a PersistentVolume manifest that references the mounted loop device.

    kind: PersistentVolume
    apiVersion: v1
    metadata:
      name: <local-block-pv10>
      annotations:
    spec:
      local:
        path: </dev/loop10> 1
      capacity:
        storage: <2Gi>
      volumeMode: Block 2
      storageClassName: local 3
      accessModes:
        - ReadWriteOnce
      persistentVolumeReclaimPolicy: Delete
      nodeAffinity:
        required:
          nodeSelectorTerms:
          - matchExpressions:
            - key: kubernetes.io/hostname
              operator: In
              values:
              - <node01> 4
    1
    The path of the loop device on the node.
    2
    Specifies it is a block PV.
    3
    Optional: Set a storage class for the PV. If you omit it, the cluster default is used.
    4
    The node on which the block device was mounted.
  5. Create the block PV.

    # oc create -f <local-block-pv10.yaml>1
    1
    The file name of the persistent volume created in the previous step.
8.18.9.5. Creating an upload data volume

You can manually create a data volume with an upload data source to use for uploading local disk images.

Procedure

  1. Create a data volume configuration that specifies spec: source: upload{}:

    apiVersion: cdi.kubevirt.io/v1beta1
    kind: DataVolume
    metadata:
      name: <upload-datavolume> 1
    spec:
      source:
          upload: {}
      pvc:
        accessModes:
          - ReadWriteOnce
        resources:
          requests:
            storage: <2Gi> 2
    1
    The name of the data volume.
    2
    The size of the data volume. Ensure that this value is greater than or equal to the size of the disk that you upload.
  2. Create the data volume by running the following command:

    $ oc create -f <upload-datavolume>.yaml
8.18.9.6. Uploading a local disk image to a data volume

You can use the virtctl CLI utility to upload a local disk image from a client machine to a data volume (DV) in your cluster. You can use a DV that already exists in your cluster or create a new DV during this procedure.

Note

After you upload a local disk image, you can add it to a virtual machine.

Prerequisites

  • You must have one of the following:

    • A raw virtual machine image file in either ISO or IMG format.
    • A virtual machine image file in QCOW2 format.
  • For best results, compress your image file according to the following guidelines before you upload it:

    • Compress a raw image file by using xz or gzip.

      Note

      Using a compressed raw image file results in the most efficient upload.

    • Compress a QCOW2 image file by using the method that is recommended for your client:

      • If you use a Linux client, sparsify the QCOW2 file by using the virt-sparsify tool.
      • If you use a Windows client, compress the QCOW2 file by using xz or gzip.
  • The kubevirt-virtctl package must be installed on the client machine.
  • The client machine must be configured to trust the OpenShift Container Platform router’s certificate.

Procedure

  1. Identify the following items:

    • The name of the upload data volume that you want to use. If this data volume does not exist, it is created automatically.
    • The size of the data volume, if you want it to be created during the upload procedure. The size must be greater than or equal to the size of the disk image.
    • The file location of the virtual machine disk image that you want to upload.
  2. Upload the disk image by running the virtctl image-upload command. Specify the parameters that you identified in the previous step. For example:

    $ virtctl image-upload dv <datavolume_name> \ 1
    --size=<datavolume_size> \ 2
    --image-path=</path/to/image> \ 3
    1
    The name of the data volume.
    2
    The size of the data volume. For example: --size=500Mi, --size=1G
    3
    The file path of the virtual machine disk image.
    Note
    • If you do not want to create a new data volume, omit the --size parameter and include the --no-create flag.
    • When uploading a disk image to a PVC, the PVC size must be larger than the size of the uncompressed virtual disk.
    • To allow insecure server connections when using HTTPS, use the --insecure parameter. Be aware that when you use the --insecure flag, the authenticity of the upload endpoint is not verified.
  3. Optional. To verify that a data volume was created, view all data volumes by running the following command:

    $ oc get dvs
8.18.9.7. CDI supported operations matrix

This matrix shows the supported CDI operations for content types against endpoints, and which of these operations requires scratch space.

Content typesHTTPHTTPSHTTP basic authRegistryUpload

KubeVirt (QCOW2)

✓ QCOW2
✓ GZ*
✓ XZ*

✓ QCOW2**
✓ GZ*
✓ XZ*

✓ QCOW2
✓ GZ*
✓ XZ*

✓ QCOW2*
□ GZ
□ XZ

✓ QCOW2*
✓ GZ*
✓ XZ*

KubeVirt (RAW)

✓ RAW
✓ GZ
✓ XZ

✓ RAW
✓ GZ
✓ XZ

✓ RAW
✓ GZ
✓ XZ

✓ RAW*
□ GZ
□ XZ

✓ RAW*
✓ GZ*
✓ XZ*

✓ Supported operation

□ Unsupported operation

* Requires scratch space

** Requires scratch space if a custom certificate authority is required

8.18.9.8. Additional resources

8.18.10. Managing virtual machine snapshots

You can create and delete virtual machine (VM) snapshots for VMs, whether the VMs are powered off (offline) or on (online). You can only restore to a powered off (offline) VM. OpenShift Virtualization supports VM snapshots on the following:

  • Red Hat OpenShift Container Storage
  • Any other cloud storage provider with the Container Storage Interface (CSI) driver that supports the Kubernetes Volume Snapshot API

Online snapshots have a default time deadline of five minutes (5m) that can be changed, if needed.

Important

Online snapshots are not supported for virtual machines that have hot-plugged virtual disks.

Note

To create snapshots of an online (Running state) VM with the highest integrity, install the QEMU guest agent.

The QEMU guest agent takes a consistent snapshot by attempting to quiesce the VM file system as much as possible, depending on the system workload. This ensures that in-flight I/O is written to the disk before the snapshot is taken. If the guest agent is not present, quiescing is not possible and a best-effort snapshot is taken. The conditions under which the snapshot was taken are reflected in the snapshot indications that are displayed in the web console or CLI.

8.18.10.1. About virtual machine snapshots

A snapshot represents the state and data of a virtual machine (VM) at a specific point in time. You can use a snapshot to restore an existing VM to a previous state (represented by the snapshot) for backup and disaster recovery or to rapidly roll back to a previous development version.

A VM snapshot is created from a VM that is powered off (Stopped state) or powered on (Running state).

When taking a snapshot of a running VM, the controller checks that the QEMU guest agent is installed and running. If so, it freezes the VM file system before taking the snapshot, and thaws the file system after the snapshot is taken.

The snapshot stores a copy of each Container Storage Interface (CSI) volume attached to the VM and a copy of the VM specification and metadata. Snapshots cannot be changed after creation.

With the VM snapshots feature, cluster administrators and application developers can:

  • Create a new snapshot
  • List all snapshots attached to a specific VM
  • Restore a VM from a snapshot
  • Delete an existing VM snapshot
8.18.10.1.1. Virtual machine snapshot controller and custom resource definitions (CRDs)

The VM snapshot feature introduces three new API objects defined as CRDs for managing snapshots:

  • VirtualMachineSnapshot: Represents a user request to create a snapshot. It contains information about the current state of the VM.
  • VirtualMachineSnapshotContent: Represents a provisioned resource on the cluster (a snapshot). It is created by the VM snapshot controller and contains references to all resources required to restore the VM.
  • VirtualMachineRestore: Represents a user request to restore a VM from a snapshot.

The VM snapshot controller binds a VirtualMachineSnapshotContent object with the VirtualMachineSnapshot object for which it was created, with a one-to-one mapping.

8.18.10.2. Installing QEMU guest agent on a Linux virtual machine

The qemu-guest-agent is widely available and available by default in Red Hat virtual machines. Install the agent and start the service.

To check if your virtual machine (VM) has the QEMU guest agent installed and running, verify that AgentConnected is listed in the VM spec.

Note

To create snapshots of an online (Running state) VM with the highest integrity, install the QEMU guest agent.

The QEMU guest agent takes a consistent snapshot by attempting to quiesce the VM’s file system as much as possible, depending on the system workload. This ensures that in-flight I/O is written to the disk before the snapshot is taken. If the guest agent is not present, quiescing is not possible and a best-effort snapshot is taken. The conditions under which the snapshot was taken are reflected in the snapshot indications that are displayed in the web console or CLI.

Procedure

  1. Access the virtual machine command line through one of the consoles or by SSH.
  2. Install the QEMU guest agent on the virtual machine:

    $ yum install -y qemu-guest-agent
  3. Ensure the service is persistent and start it:

    $ systemctl enable --now qemu-guest-agent
8.18.10.3. Installing QEMU guest agent on a Windows virtual machine

For Windows virtual machines, the QEMU guest agent is included in the VirtIO drivers. Install the drivers on an existng or new Windows system.

To check if your virtual machine (VM) has the QEMU guest agent installed and running, verify that AgentConnected is listed in the VM spec.

Note

To create snapshots of an online (Running state) VM with the highest integrity, install the QEMU guest agent.

The QEMU guest agent takes a consistent snapshot by attempting to quiesce the VM’s file system as much as possible, depending on the system workload. This ensures that in-flight I/O is written to the disk before the snapshot is taken. If the guest agent is not present, quiescing is not possible and a best-effort snapshot is taken. The conditions under which the snapshot was taken are reflected in the snapshot indications that are displayed in the web console or CLI.

8.18.10.3.1. Installing VirtIO drivers on an existing Windows virtual machine

Install the VirtIO drivers from the attached SATA CD drive to an existing Windows virtual machine.

Note

This procedure uses a generic approach to adding drivers to Windows. The process might differ slightly between versions of Windows. See the installation documentation for your version of Windows for specific installation steps.

Procedure

  1. Start the virtual machine and connect to a graphical console.
  2. Log in to a Windows user session.
  3. Open Device Manager and expand Other devices to list any Unknown device.

    1. Open the Device Properties to identify the unknown device. Right-click the device and select Properties.
    2. Click the Details tab and select Hardware Ids in the Property list.
    3. Compare the Value for the Hardware Ids with the supported VirtIO drivers.
  4. Right-click the device and select Update Driver Software.
  5. Click Browse my computer for driver software and browse to the attached SATA CD drive, where the VirtIO drivers are located. The drivers are arranged hierarchically according to their driver type, operating system, and CPU architecture.
  6. Click Next to install the driver.
  7. Repeat this process for all the necessary VirtIO drivers.
  8. After the driver installs, click Close to close the window.
  9. Reboot the virtual machine to complete the driver installation.
8.18.10.3.2. Installing VirtIO drivers during Windows installation

Install the VirtIO drivers from the attached SATA CD driver during Windows installation.

Note

This procedure uses a generic approach to the Windows installation and the installation method might differ between versions of Windows. See the documentation for the version of Windows that you are installing.

Procedure

  1. Start the virtual machine and connect to a graphical console.
  2. Begin the Windows installation process.
  3. Select the Advanced installation.
  4. The storage destination will not be recognized until the driver is loaded. Click Load driver.
  5. The drivers are attached as a SATA CD drive. Click OK and browse the CD drive for the storage driver to load. The drivers are arranged hierarchically according to their driver type, operating system, and CPU architecture.
  6. Repeat the previous two steps for all required drivers.
  7. Complete the Windows installation.
8.18.10.4. Creating a virtual machine snapshot in the web console

You can create a virtual machine (VM) snapshot by using the web console.

Note

To create snapshots of an online (Running state) VM with the highest integrity, install the QEMU guest agent.

The QEMU guest agent takes a consistent snapshot by attempting to quiesce the VM’s file system as much as possible, depending on the system workload. This ensures that in-flight I/O is written to the disk before the snapshot is taken. If the guest agent is not present, quiescing is not possible and a best-effort snapshot is taken. The conditions under which the snapshot was taken are reflected in the snapshot indications that are displayed in the web console or CLI.

Note

The VM snapshot only includes disks that meet the following requirements:

  • Must be either a data volume or persistent volume claim
  • Belong to a storage class that supports Container Storage Interface (CSI) volume snapshots

Procedure

  1. Click WorkloadsVirtualization from the side menu.
  2. Click the Virtual Machines tab.
  3. Select a virtual machine to open the Virtual Machine Overview screen.
  4. If the virtual machine is running, click ActionsStop Virtual Machine to power it down.
  5. Click the Snapshots tab and then click Take Snapshot.
  6. Fill in the Snapshot Name and optional Description fields.
  7. Expand Disks included in this Snapshot to see the storage volumes to be included in the snapshot.
  8. If your VM has disks that cannot be included in the snapshot and you still wish to proceed, select the I am aware of this warning and wish to proceed checkbox.
  9. Click Save.
8.18.10.5. Creating a virtual machine snapshot in the CLI

You can create a virtual machine (VM) snapshot for an offline or online VM by creating a VirtualMachineSnapshot object. Kubevirt will coordinate with the QEMU guest agent to create a snapshot of the online VM.

Note

To create snapshots of an online (Running state) VM with the highest integrity, install the QEMU guest agent.

The QEMU guest agent takes a consistent snapshot by attempting to quiesce the VM’s file system as much as possible, depending on the system workload. This ensures that in-flight I/O is written to the disk before the snapshot is taken. If the guest agent is not present, quiescing is not possible and a best-effort snapshot is taken. The conditions under which the snapshot was taken are reflected in the snapshot indications that are displayed in the web console or CLI.

Prerequisites

  • Ensure that the persistent volume claims (PVCs) are in a storage class that supports Container Storage Interface (CSI) volume snapshots.
  • Install the OpenShift CLI (oc).
  • Optional: Power down the VM for which you want to create a snapshot.

Procedure

  1. Create a YAML file to define a VirtualMachineSnapshot object that specifies the name of the new VirtualMachineSnapshot and the name of the source VM.

    For example:

    apiVersion: snapshot.kubevirt.io/v1alpha1
    kind: VirtualMachineSnapshot
    metadata:
      name: my-vmsnapshot 1
    spec:
      source:
        apiGroup: kubevirt.io
        kind: VirtualMachine
        name: my-vm 2
    1
    The name of the new VirtualMachineSnapshot object.
    2
    The name of the source VM.
  2. Create the VirtualMachineSnapshot resource. The snapshot controller creates a VirtualMachineSnapshotContent object, binds it to the VirtualMachineSnapshot and updates the status and readyToUse fields of the VirtualMachineSnapshot object.

    $ oc create -f <my-vmsnapshot>.yaml
  3. Optional: If you are taking an online snapshot, you can use the wait command and monitor the status of the snapshot:

    1. Enter the following command:

      $ oc wait my-vm my-vmsnapshot --for condition=Ready
    2. Verify the status of the snapshot:

      • InProgress - The online snapshot operation is still in progress.
      • Succeeded - The online snapshot operation completed successfully.
      • Failed - The online snapshot operaton failed.

        Note

        Online snapshots have a default time deadline of five minutes (5m). If the snapshot does not complete successfully in five minutes, the status is set to failed. Afterwards, the file system will be thawed and the VM unfrozen but the status remains failed until you delete the failed snapshot image.

        To change the default time deadline, add the FailureDeadline attribute to the VM snapshot spec with the time designated in minutes (m) or in seconds (s) that you want to specify before the snapshot operation times out.

        To set no deadline, you can specify 0, though this is generally not recommended, as it can result in an unresponsive VM.

        If you do not specify a unit of time such as m or s, the default is seconds (s).

Verification

  1. Verify that the VirtualMachineSnapshot object is created and bound with VirtualMachineSnapshotContent. The readyToUse flag must be set to true.

    $ oc describe vmsnapshot <my-vmsnapshot>

    Example output

    apiVersion: snapshot.kubevirt.io/v1alpha1
    kind: VirtualMachineSnapshot
    metadata:
      creationTimestamp: "2020-09-30T14:41:51Z"
      finalizers:
      - snapshot.kubevirt.io/vmsnapshot-protection
      generation: 5
      name: mysnap
      namespace: default
      resourceVersion: "3897"
      selfLink: /apis/snapshot.kubevirt.io/v1alpha1/namespaces/default/virtualmachinesnapshots/my-vmsnapshot
      uid: 28eedf08-5d6a-42c1-969c-2eda58e2a78d
    spec:
      source:
        apiGroup: kubevirt.io
        kind: VirtualMachine
        name: my-vm
    status:
      conditions:
      - lastProbeTime: null
        lastTransitionTime: "2020-09-30T14:42:03Z"
        reason: Operation complete
        status: "False" 1
        type: Progressing
      - lastProbeTime: null
        lastTransitionTime: "2020-09-30T14:42:03Z"
        reason: Operation complete
        status: "True" 2
        type: Ready
      creationTime: "2020-09-30T14:42:03Z"
      readyToUse: true 3
      sourceUID: 355897f3-73a0-4ec4-83d3-3c2df9486f4f
      virtualMachineSnapshotContentName: vmsnapshot-content-28eedf08-5d6a-42c1-969c-2eda58e2a78d 4

    1
    The status field of the Progressing condition specifies if the snapshot is still being created.
    2
    The status field of the Ready condition specifies if the snapshot creation process is complete.
    3
    Specifies if the snapshot is ready to be used.
    4
    Specifies that the snapshot is bound to a VirtualMachineSnapshotContent object created by the snapshot controller.
  2. Check the spec:volumeBackups property of the VirtualMachineSnapshotContent resource to verify that the expected PVCs are included in the snapshot.
8.18.10.6. Verifying online snapshot creation with snapshot indications

Snapshot indications are contextual information about online virtual machine (VM) snapshot operations. Indications are not available for offline virtual machine (VM) snapshot operations. Indications are helpful in describing details about the online snapshot creation.

Prerequisites

  • To view indications, you must have attempted to create an online VM snapshot using the CLI or the web console.

Procedure

  1. Display the output from the snapshot indications by doing one of the following:

    • For snapshots created with the CLI, view indicator output in the VirtualMachineSnapshot object YAML, in the status field.
    • For snapshots created using the web console, click VirtualMachineSnapshot > Status in the Snapshot details screen.
  2. Verify the status of your online VM snapshot:

    • Online indicates that the VM was running during online snapshot creation.
    • NoGuestAgent indicates that the QEMU guest agent was not running during online snapshot creation. The QEMU guest agent could not be used to freeze and thaw the file system, either because the QEMU guest agent was not installed or running or due to another error.
8.18.10.7. Restoring a virtual machine from a snapshot in the web console

You can restore a virtual machine (VM) to a previous configuration represented by a snapshot in the web console.

Procedure

  1. Click WorkloadsVirtualization from the side menu.
  2. Click the Virtual Machines tab.
  3. Select a virtual machine to open the Virtual Machine Overview screen.
  4. If the virtual machine is running, click ActionsStop Virtual Machine to power it down.
  5. Click the Snapshots tab. The page displays a list of snapshots associated with the virtual machine.
  6. Choose one of the following methods to restore a VM snapshot:

    1. For the snapshot that you want to use as the source to restore the VM, click Restore.
    2. Select a snapshot to open the Snapshot Details screen and click ActionsRestore Virtual Machine Snapshot.
  7. In the confirmation pop-up window, click Restore to restore the VM to its previous configuration represented by the snapshot.
8.18.10.8. Restoring a virtual machine from a snapshot in the CLI

You can restore an existing virtual machine (VM) to a previous configuration by using a VM snapshot. You can only restore from an offline VM snapshot.

Prerequisites

  • Install the OpenShift CLI (oc).
  • Power down the VM you want to restore to a previous state.

Procedure

  1. Create a YAML file to define a VirtualMachineRestore object that specifies the name of the VM you want to restore and the name of the snapshot to be used as the source.

    For example:

    apiVersion: snapshot.kubevirt.io/v1alpha1
    kind: VirtualMachineRestore
    metadata:
      name: my-vmrestore 1
    spec:
      target:
        apiGroup: kubevirt.io
        kind: VirtualMachine
        name: my-vm 2
      virtualMachineSnapshotName: my-vmsnapshot 3
    1
    The name of the new VirtualMachineRestore object.
    2
    The name of the target VM you want to restore.
    3
    The name of the VirtualMachineSnapshot object to be used as the source.
  2. Create the VirtualMachineRestore resource. The snapshot controller updates the status fields of the VirtualMachineRestore object and replaces the existing VM configuration with the snapshot content.

    $ oc create -f <my-vmrestore>.yaml

Verification

  • Verify that the VM is restored to the previous state represented by the snapshot. The complete flag must be set to true.

    $ oc get vmrestore <my-vmrestore>

    Example output

    apiVersion: snapshot.kubevirt.io/v1alpha1
    kind: VirtualMachineRestore
    metadata:
    creationTimestamp: "2020-09-30T14:46:27Z"
    generation: 5
    name: my-vmrestore
    namespace: default
    ownerReferences:
    - apiVersion: kubevirt.io/v1
      blockOwnerDeletion: true
      controller: true
      kind: VirtualMachine
      name: my-vm
      uid: 355897f3-73a0-4ec4-83d3-3c2df9486f4f
      resourceVersion: "5512"
      selfLink: /apis/snapshot.kubevirt.io/v1alpha1/namespaces/default/virtualmachinerestores/my-vmrestore
      uid: 71c679a8-136e-46b0-b9b5-f57175a6a041
      spec:
        target:
          apiGroup: kubevirt.io
          kind: VirtualMachine
          name: my-vm
      virtualMachineSnapshotName: my-vmsnapshot
      status:
      complete: true 1
      conditions:
      - lastProbeTime: null
      lastTransitionTime: "2020-09-30T14:46:28Z"
      reason: Operation complete
      status: "False" 2
      type: Progressing
      - lastProbeTime: null
      lastTransitionTime: "2020-09-30T14:46:28Z"
      reason: Operation complete
      status: "True" 3
      type: Ready
      deletedDataVolumes:
      - test-dv1
      restoreTime: "2020-09-30T14:46:28Z"
      restores:
      - dataVolumeName: restore-71c679a8-136e-46b0-b9b5-f57175a6a041-datavolumedisk1
      persistentVolumeClaim: restore-71c679a8-136e-46b0-b9b5-f57175a6a041-datavolumedisk1
      volumeName: datavolumedisk1
      volumeSnapshotName: vmsnapshot-28eedf08-5d6a-42c1-969c-2eda58e2a78d-volume-datavolumedisk1

    1
    Specifies if the process of restoring the VM to the state represented by the snapshot is complete.
    2
    The status field of the Progressing condition specifies if the VM is still being restored.
    3
    The status field of the Ready condition specifies if the VM restoration process is complete.
8.18.10.9. Deleting a virtual machine snapshot in the web console

You can delete an existing virtual machine snapshot by using the web console.

Procedure

  1. Click WorkloadsVirtualization from the side menu.
  2. Click the Virtual Machines tab.
  3. Select a virtual machine to open the Virtual Machine Overview screen.
  4. Click the Snapshots tab. The page displays a list of snapshots associated with the virtual machine.
  5. Choose one of the following methods to delete a virtual machine snapshot:

    1. Click the Options menu kebab of the virtual machine snapshot that you want to delete and select Delete Virtual Machine Snapshot.
    2. Select a snapshot to open the Snapshot Details screen and click ActionsDelete Virtual Machine Snapshot.
  6. In the confirmation pop-up window, click Delete to delete the snapshot.
8.18.10.10. Deleting a virtual machine snapshot in the CLI

You can delete an existing virtual machine (VM) snapshot by deleting the appropriate VirtualMachineSnapshot object.

Prerequisites

  • Install the OpenShift CLI (oc).

Procedure

  • Delete the VirtualMachineSnapshot object. The snapshot controller deletes the VirtualMachineSnapshot along with the associated VirtualMachineSnapshotContent object.

    $ oc delete vmsnapshot <my-vmsnapshot>

Verification

  • Verify that the snapshot is deleted and no longer attached to this VM:

    $ oc get vmsnapshot
8.18.10.11. Additional resources

8.18.11. Moving a local virtual machine disk to a different node

Virtual machines that use local volume storage can be moved so that they run on a specific node.

You might want to move the virtual machine to a specific node for the following reasons:

  • The current node has limitations to the local storage configuration.
  • The new node is better optimized for the workload of that virtual machine.

To move a virtual machine that uses local storage, you must clone the underlying volume by using a data volume. After the cloning operation is complete, you can edit the virtual machine configuration so that it uses the new data volume, or add the new data volume to another virtual machine.

Tip

When you enable preallocation globally, or for a single data volume, the Containerized Data Importer (CDI) preallocates disk space during cloning. Preallocation enhances write performance. For more information, see Using preallocation for data volumes.

Note

Users without the cluster-admin role require additional user permissions to clone volumes across namespaces.

8.18.11.1. Cloning a local volume to another node

You can move a virtual machine disk so that it runs on a specific node by cloning the underlying persistent volume claim (PVC).

To ensure the virtual machine disk is cloned to the correct node, you must either create a new persistent volume (PV) or identify one on the correct node. Apply a unique label to the PV so that it can be referenced by the data volume.

Note

The destination PV must be the same size or larger than the source PVC. If the destination PV is smaller than the source PVC, the cloning operation fails.

Prerequisites

  • The virtual machine must not be running. Power down the virtual machine before cloning the virtual machine disk.

Procedure

  1. Either create a new local PV on the node, or identify a local PV already on the node:

    • Create a local PV that includes the nodeAffinity.nodeSelectorTerms parameters. The following manifest creates a 10Gi local PV on node01.

      kind: PersistentVolume
      apiVersion: v1
      metadata:
        name: <destination-pv> 1
        annotations:
      spec:
        accessModes:
        - ReadWriteOnce
        capacity:
          storage: 10Gi 2
        local:
          path: /mnt/local-storage/local/disk1 3
        nodeAffinity:
          required:
            nodeSelectorTerms:
            - matchExpressions:
              - key: kubernetes.io/hostname
                operator: In
                values:
                - node01 4
        persistentVolumeReclaimPolicy: Delete
        storageClassName: local
        volumeMode: Filesystem
      1
      The name of the PV.
      2
      The size of the PV. You must allocate enough space, or the cloning operation fails. The size must be the same as or larger than the source PVC.
      3
      The mount path on the node.
      4
      The name of the node where you want to create the PV.
    • Identify a PV that already exists on the target node. You can identify the node where a PV is provisioned by viewing the nodeAffinity field in its configuration:

      $ oc get pv <destination-pv> -o yaml

      The following snippet shows that the PV is on node01:

      Example output

      ...
      spec:
        nodeAffinity:
          required:
            nodeSelectorTerms:
            - matchExpressions:
              - key: kubernetes.io/hostname 1
                operator: In
                values:
                - node01 2
      ...

      1
      The kubernetes.io/hostname key uses the node hostname to select a node.
      2
      The hostname of the node.
  2. Add a unique label to the PV:

    $ oc label pv <destination-pv> node=node01
  3. Create a data volume manifest that references the following:

    • The PVC name and namespace of the virtual machine.
    • The label you applied to the PV in the previous step.
    • The size of the destination PV.

      apiVersion: cdi.kubevirt.io/v1beta1
      kind: DataVolume
      metadata:
        name: <clone-datavolume> 1
      spec:
        source:
          pvc:
            name: "<source-vm-disk>" 2
            namespace: "<source-namespace>" 3
        pvc:
          accessModes:
            - ReadWriteOnce
          selector:
            matchLabels:
              node: node01 4
          resources:
            requests:
              storage: <10Gi> 5
      1
      The name of the new data volume.
      2
      The name of the source PVC. If you do not know the PVC name, you can find it in the virtual machine configuration: spec.volumes.persistentVolumeClaim.claimName.
      3
      The namespace where the source PVC exists.
      4
      The label that you applied to the PV in the previous step.
      5
      The size of the destination PV.
  4. Start the cloning operation by applying the data volume manifest to your cluster:

    $ oc apply -f <clone-datavolume.yaml>

The data volume clones the PVC of the virtual machine into the PV on the specific node.

8.18.12. Expanding virtual storage by adding blank disk images

You can increase your storage capacity or create new data partitions by adding blank disk images to OpenShift Virtualization.

8.18.12.1. About data volumes

DataVolume objects are custom resources that are provided by the Containerized Data Importer (CDI) project. Data volumes orchestrate import, clone, and upload operations that are associated with an underlying persistent volume claim (PVC). Data volumes are integrated with OpenShift Virtualization, and they prevent a virtual machine from being started before the PVC has been prepared.

8.18.12.2. Creating a blank disk image with data volumes

You can create a new blank disk image in a persistent volume claim by customizing and deploying a data volume configuration file.

Prerequisites

  • At least one available persistent volume.
  • Install the OpenShift CLI (oc).

Procedure

  1. Edit the DataVolume manifest:

    apiVersion: cdi.kubevirt.io/v1beta1
    kind: DataVolume
    metadata:
      name: blank-image-datavolume
    spec:
      source:
          blank: {}
      pvc:
        # Optional: Set the storage class or omit to accept the default
        # storageClassName: "hostpath"
        accessModes:
          - ReadWriteOnce
        resources:
          requests:
            storage: 500Mi
  2. Create the blank disk image by running the following command:

    $ oc create -f <blank-image-datavolume>.yaml
8.18.12.3. Additional resources

8.18.13. Cloning a data volume using smart-cloning

Smart-cloning is a built-in feature of OpenShift Container Platform Storage (OCS), designed to enhance performance of the cloning process. Clones created with smart-cloning are faster and more efficient than host-assisted cloning.

You do not need to perform any action to enable smart-cloning, but you need to ensure your storage environment is compatible with smart-cloning to use this feature.

When you create a data volume with a persistent volume claim (PVC) source, you automatically initiate the cloning process. You always receive a clone of the data volume if your environment supports smart-cloning or not. However, you will only receive the performance benefits of smart cloning if your storage provider supports smart-cloning.

8.18.13.1. About smart-cloning

When a data volume is smart-cloned, the following occurs:

  1. A snapshot of the source persistent volume claim (PVC) is created.
  2. A PVC is created from the snapshot.
  3. The snapshot is deleted.
8.18.13.2. Cloning a data volume

Prerequisites

For smart-cloning to occur, the following conditions are required:

  • Your storage provider must support snapshots.
  • The source and target PVCs must be defined to the same storage class.
  • The source and target PVCs share the same volumeMode.
  • The VolumeSnapshotClass object must reference the storage class defined to both the source and target PVCs.

Procedure

To initiate cloning of a data volume:

  1. Create a YAML file for a DataVolume object that specifies the name of the new data volume and the name and namespace of the source PVC. In this example, because you specify the storage API, there is no need to specify accessModes or volumeMode. The optimal values will be calculated for you automatically.

    apiVersion: cdi.kubevirt.io/v1beta1
    kind: DataVolume
    metadata:
      name: <cloner-datavolume> 1
    spec:
      source:
        pvc:
          namespace: "<source-namespace>" 2
          name: "<my-favorite-vm-disk>" 3
      storage: 4
        resources:
          requests:
            storage: <2Gi> 5
    1
    The name of the new data volume.
    2
    The namespace where the source PVC exists.
    3
    The name of the source PVC.
    4
    Specifies allocation with the storage API
    5
    The size of the new data volume.
  2. Start cloning the PVC by creating the data volume:

    $ oc create -f <cloner-datavolume>.yaml
    Note

    Data volumes prevent a virtual machine from starting before the PVC is prepared, so you can create a virtual machine that references the new data volume while the PVC clones.

8.18.13.3. Additional resources

8.18.14. Creating and using boot sources

A boot source contains a bootable operating system (OS) and all of the configuration settings for the OS, such as drivers.

You use a boot source to create virtual machine templates with specific configurations. These templates can be used to create any number of available virtual machines.

Quick Start tours are available in the OpenShift Container Platform web console to assist you in creating a custom boot source, uploading a boot source, and other tasks. Select Quick Starts from the Help menu to view the Quick Start tours.

8.18.14.1. About virtual machines and boot sources

Virtual machines consist of a virtual machine definition and one or more disks that are backed by data volumes. Virtual machine templates enable you to create virtual machines using predefined virtual machine specifications.

Every virtual machine template requires a boot source, which is a fully configured virtual machine disk image including configured drivers. Each virtual machine template contains a virtual machine definition with a pointer to the boot source. Each boot source has a predefined name and namespace. For some operating systems, a boot source is automatically provided. If it is not provided, then an administrator must prepare a custom boot source.

Provided boot sources are updated automatically to the latest version of the operating system. For auto-updated boot sources, persistent volume claims (PVCs) are created with the cluster’s default storage class. If you select a different default storage class after configuration, you must delete the existing data volumes in the cluster namespace that are configured with the previous default storage class.

To use the boot sources feature, install the latest release of OpenShift Virtualization. The namespace openshift-virtualization-os-images enables the feature and is installed with the OpenShift Virtualization Operator. Once the boot source feature is installed, you can create boot sources, attach them to templates, and create virtual machines from the templates.

Define a boot source by using a persistent volume claim (PVC) that is populated by uploading a local file, cloning an existing PVC, importing from a registry, or by URL. Attach a boot source to a virtual machine template by using the web console. After the boot source is attached to a virtual machine template, you create any number of fully configured ready-to-use virtual machines from the template.

8.18.14.2. Importing a Red Hat Enterprise Linux image as a boot source

You can import a Red Hat Enterprise Linux (RHEL) image as a boot source by specifying the URL address for the image.

Prerequisites

  • You must have access to the web server with the operating system image. For example: Red Hat Enterprise Linux web page with images.

Procedure

  1. In the OpenShift Virtualization console, click WorkloadsVirtualization from the side menu.
  2. Click the Templates tab.
  3. Identify the RHEL template for which you want to configure a boot source and click Add source.
  4. In the Add boot source to template window, select Import via URL (creates PVC) from the Boot source type list.
  5. Click RHEL download page to access the Red Hat Customer Portal. A list of available installers and images is displayed on the Download Red Hat Enterprise Linux page.
  6. Identify the Red Hat Enterprise Linux KVM guest image that you want to download. Right-click Download Now, and copy the URL for the image.
  7. In the Add boot source to template window, paste the copied URL of the guest image into the Import URL field, and click Save and import.

Verification

To verify that a boot source was added to the template:

  1. Click the Templates tab.
  2. Confirm that the tile for this template displays a green checkmark.

You can now use this template to create RHEL virtual machines.

8.18.14.3. Adding a boot source for a virtual machine template

A boot source can be configured for any virtual machine template that you want to use for creating virtual machines or custom templates. When virtual machine templates are configured with a boot source, they are labeled Available in the Templates tab. After you add a boot source to a template, you can create a new virtual machine from the template.

There are four methods for selecting and adding a boot source in the web console:

  • Upload local file (creates PVC)
  • Import via URL (creates PVC)
  • Clone existing PVC (creates PVC)
  • Import via Registry (creates PVC)

Prerequisites

  • To add a boot source, you must be logged in as a user with the os-images.kubevirt.io:edit RBAC role or as an administrator. You do not need special privileges to create a virtual machine from a template with a boot source added.
  • To upload a local file, the operating system image file must exist on your local machine.
  • To import via URL, access to the web server with the operating system image is required. For example: the Red Hat Enterprise Linux web page with images.
  • To clone an existing PVC, access to the project with a PVC is required.
  • To import via registry, access to the container registry is required.

Procedure

  1. In the OpenShift Virtualization console, click WorkloadsVirtualization from the side menu.
  2. Click the Templates tab.
  3. Identify the virtual machine template for which you want to configure a boot source and click Add source.
  4. In the Add boot source to template window, click Select boot source, select a method for creating a persistent volume claim (PVC): Upload local file, Import via URL, Clone existing PVC, or Import via Registry.
  5. Optional: Click This is a CD-ROM boot source to mount a CD-ROM and use it to install the operating system on to an empty disk. The additional empty disk is automatically created and mounted by OpenShift Virtualization. If the additional disk is not needed, you can remove it when you create the virtual machine.
  6. Enter a value for Persistent Volume Claim size to specify the PVC size that is adequate for the uncompressed image and any additional space that is required.

    1. Optional: Enter a name for Source provider to associate the name with this template.
    2. Optional: Advanced Storage settings: Click Storage class and select the storage class that is used to create the disk. Typically, this storage class is the default storage class that is created for use by all PVCs.

      Note

      Provided boot sources are updated automatically to the latest version of the operating system. For auto-updated boot sources, persistent volume claims (PVCs) are created with the cluster’s default storage class. If you select a different default storage class after configuration, you must delete the existing data volumes in the cluster namespace that are configured with the previous default storage class.

    3. Optional: Advanced Storage settings: Click Access mode and select an access mode for the persistent volume:

      • Single User (RWO) mounts the volume as read-write by a single node.
      • Shared Access (RWX) mounts the volume as read-write by many nodes.
      • Read Only (ROX) mounts the volume as read-only by many nodes.
    4. Optional: Advanced Storage settings: Click Volume mode if you want to select Block instead of the default value Filesystem. OpenShift Virtualization can statically provision raw block volumes. These volumes do not have a file system, and can provide performance benefits for applications that either write to the disk directly or implement their own storage service.
  7. Select the appropriate method to save your boot source:

    1. Click Save and upload if you uploaded a local file.
    2. Click Save and import if you imported content from a URL or the registry.
    3. Click Save and clone if you cloned an existing PVC.

Your custom virtual machine template with a boot source is listed in the Templates tab, and you can create virtual machines by using this template.

8.18.14.4. Creating a virtual machine from a template with an attached boot source

After you add a boot source to a template, you can create a new virtual machine from the template.

Procedure

  1. In the OpenShift Container Platform web console, click Workloads > Virtualization in the side menu.
  2. From the Virtual Machines tab or the Templates tab, click Create and select Virtual Machine with Wizard.
  3. In the Select a template step, select an OS from the Operating System list that has the (Source available) label next to the OS and version name. The (Source available) label indicates that a boot source is available for this OS.
  4. Click Review and Confirm.
  5. Review your virtual machine settings and edit them, if required.
  6. Click Create Virtual Machine to create your virtual machine. The Successfully created virtual machine page is displayed.
8.18.14.5. Creating a custom boot source

You can prepare a custom disk image, based on an existing disk image, for use as a boot source.

Use this procedure to complete the following tasks:

  • Preparing a custom disk image
  • Creating a boot source from the custom disk image
  • Attaching the boot source to a custom template

Procedure

  1. In the OpenShift Virtualization console, click Workloads > Virtualization from the side menu.
  2. Click the Templates tab.
  3. Click the link in the Source provider column for the template you want to customize. A window displays, indicating that the template currently has a defined source.
  4. In the window, click the Customize source link.
  5. Click Continue in the About boot source customization window to proceed with customization after reading the information provided about the boot source customization process.
  6. On the Prepare boot source customization page, in the Define new template section:

    1. Select the New template namespace field and then choose a project.
    2. Enter the name of the custom template in the New template name field.
    3. Enter the name of the template provider in the New template provider field.
    4. Select the New template support field and then choose the appropriate value, indicating support contacts for the custom template you create.
    5. Select the New template flavor field and then choose the appropriate CPU and memory values for the custom image you create.
  7. In the Prepare boot source for customization section, customize the cloud-init YAML script, if needed, to define login credentials. Otherwise, the script generates default credentials for you.
  8. Click Start Customization. The customization process begins and the Preparing boot source customization page displays, followed by the Customize boot source page. The Customize boot source page displays the output of the running script. When the script completes, your custom image is available.
  9. In the VNC console, click show password in the Guest login credentials section. Your login credentials display.
  10. When the image is ready for login, sign in with the VNC Console by providing the user name and password displayed in the Guest login credentials section.
  11. Verify the custom image works as expected. If it does, click Make this boot source available.
  12. In the Finish customization and make template available window, select I have sealed the boot source so it can be used as a template and then click Apply.
  13. On the Finishing boot source customization page, wait for the template creation process to complete. Click Navigate to template details or Navigate to template list to view your customized template, created from your custom boot source.
8.18.14.6. Additional resources

8.18.15. Hot-plugging virtual disks

Important

Hot-plugging virtual disks is a Technology Preview feature only. Technology Preview features are not supported with Red Hat production service level agreements (SLAs) and might not be functionally complete. Red Hat does not recommend using them in production. These features provide early access to upcoming product features, enabling customers to test functionality and provide feedback during the development process.

For more information about the support scope of Red Hat Technology Preview features, see Technology Preview Features Support Scope.

Hot-plug and hot-unplug virtual disks when you want to add or remove them without stopping your virtual machine or virtual machine instance. This capability is helpful when you need to add storage to a running virtual machine without incurring down-time.

When you hot-plug a virtual disk, you attach a virtual disk to a virtual machine instance while the virtual machine is running.

When you hot-unplug a virtual disk, you detach a virtual disk from a virtual machine instance while the virtual machine is running.

Only data volumes and persistent volume claims (PVCs) can be hot-plugged and hot-unplugged. You cannot hot-plug or hot-unplug container disks.

8.18.15.1. Hot-plugging a virtual disk using the CLI

Hot-plug virtual disks that you want to attach to a virtual machine instance (VMI) while a virtual machine is running.

Prerequisites

  • You must have a running virtual machine to hot-plug a virtual disk.
  • You must have at least one data volume or persistent volume claim (PVC) available for hot-plugging.

Procedure

  • Hot-plug a virtual disk by running the following command:

    $ virtctl addvolume <virtual-machine|virtual-machine-instance> --volume-name=<datavolume|PVC> \
    [--persist] [--serial=<label-name>]
    • Use the optional --persist flag to add the hot-plugged disk to the virtual machine specification as a permanently mounted virtual disk. Stop, restart, or reboot the virtual machine to permanently mount the virtual disk. After specifying the --persist flag, you can no longer hot-plug or hot-unplug the virtual disk. The --persist flag applies to virtual machines, not virtual machine instances.
    • The optional --serial flag allows you to add an alphanumeric string label of your choice. This helps you to identify the hot-plugged disk in a guest virtual machine. If you do not specify this option, the label defaults to the name of the hot-plugged data volume or PVC.
8.18.15.2. Hot-unplugging a virtual disk using the CLI

Hot-unplug virtual disks that you want to detach from a virtual machine instance (VMI) while a virtual machine is running.

Prerequisites

  • Your virtual machine must be running.
  • You must have at least one data volume or persistent volume claim (PVC) available and hot-plugged.

Procedure

  • Hot-unplug a virtual disk by running the following command:

    $ virtctl removevolume <virtual-machine|virtual-machine-instance> --volume-name=<datavolume|PVC>
8.18.15.3. Hot-plugging a virtual disk using the web console

Hot-plug virtual disks that you want to attach to a virtual machine instance (VMI) while a virtual machine is running.

Prerequisites

  • You must have a running virtual machine to hot-plug a virtual disk.

Procedure

  1. Click WorkloadsVirtualization from the side menu.
  2. On the Virtual Machines tab, select the running virtual machine select the running virtual machine to which you want to hot-plug a virtual disk.
  3. On the Disks tab, click Add Disk.
  4. In the Add Disk window, fill in the information for the virtual disk that you want to hot-plug.
  5. Click Add.
8.18.15.4. Hot-unplugging a virtual disk using the web console

Hot-unplug virtual disks that you want to attach to a virtual machine instance (VMI) while a virtual machine is running.

Prerequisites

  • Your virtual machine must be running with a hot-plugged disk attached.

Procedure

  1. Click WorkloadsVirtualization from the side menu.
  2. On the Virtual Machines tab, select the running virtual machine with the disk you want to hot-unplug.
  3. On the Disks tab, click the Options menu kebab of the virtual disk that you want to hot-unplug.
  4. Click Delete.

8.18.16. Using container disks with virtual machines

You can build a virtual machine image into a container disk and store it in your container registry. You can then import the container disk into persistent storage for a virtual machine or attach it directly to the virtual machine for ephemeral storage.

Important

If you use large container disks, I/O traffic might increase, impacting worker nodes. This can lead to unavailable nodes. You can resolve this by:

8.18.16.1. About container disks

A container disk is a virtual machine image that is stored as a container image in a container image registry. You can use container disks to deliver the same disk images to multiple virtual machines and to create large numbers of virtual machine clones.

A container disk can either be imported into a persistent volume claim (PVC) by using a data volume that is attached to a virtual machine, or attached directly to a virtual machine as an ephemeral containerDisk volume.

8.18.16.1.1. Importing a container disk into a PVC by using a data volume

Use the Containerized Data Importer (CDI) to import the container disk into a PVC by using a data volume. You can then attach the data volume to a virtual machine for persistent storage.

8.18.16.1.2. Attaching a container disk to a virtual machine as a containerDisk volume

A containerDisk volume is ephemeral. It is discarded when the virtual machine is stopped, restarted, or deleted. When a virtual machine with a containerDisk volume starts, the container image is pulled from the registry and hosted on the node that is hosting the virtual machine.

Use containerDisk volumes for read-only file systems such as CD-ROMs or for disposable virtual machines.

Important

Using containerDisk volumes for read-write file systems is not recommended because the data is temporarily written to local storage on the hosting node. This slows live migration of the virtual machine, such as in the case of node maintenance, because the data must be migrated to the destination node. Additionally, all data is lost if the node loses power or otherwise shuts down unexpectedly.

8.18.16.2. Preparing a container disk for virtual machines

You must build a container disk with a virtual machine image and push it to a container registry before it can used with a virtual machine. You can then either import the container disk into a PVC using a data volume and attach it to a virtual machine, or you can attach the container disk directly to a virtual machine as an ephemeral containerDisk volume.

The size of a disk image inside a container disk is limited by the maximum layer size of the registry where the container disk is hosted.

Note

For Red Hat Quay, you can change the maximum layer size by editing the YAML configuration file that is created when Red Hat Quay is first deployed.

Prerequisites

  • Install podman if it is not already installed.
  • The virtual machine image must be either QCOW2 or RAW format.

Procedure

  1. Create a Dockerfile to build the virtual machine image into a container image. The virtual machine image must be owned by QEMU, which has a UID of 107, and placed in the /disk/ directory inside the container. Permissions for the /disk/ directory must then be set to 0440.

    The following example uses the Red Hat Universal Base Image (UBI) to handle these configuration changes in the first stage, and uses the minimal scratch image in the second stage to store the result:

    $ cat > Dockerfile << EOF
    FROM registry.access.redhat.com/ubi8/ubi:latest AS builder
    ADD --chown=107:107 <vm_image>.qcow2 /disk/ 1
    RUN chmod 0440 /disk/*
    
    FROM scratch
    COPY --from=builder /disk/* /disk/
    EOF
    1
    Where <vm_image> is the virtual machine image in either QCOW2 or RAW format.
    To use a remote virtual machine image, replace <vm_image>.qcow2 with the complete url for the remote image.
  2. Build and tag the container:

    $ podman build -t <registry>/<container_disk_name>:latest .
  3. Push the container image to the registry:

    $ podman push <registry>/<container_disk_name>:latest

If your container registry does not have TLS you must add it as an insecure registry before you can import container disks into persistent storage.

8.18.16.3. Disabling TLS for a container registry to use as insecure registry

You can disable TLS (transport layer security) for one or more container registries by editing the insecureRegistries field of the HyperConverged custom resource.

Prerequisites

  • Log in to the cluster as a user with the cluster-admin role.

Procedure

  • Edit the HyperConverged custom resource and add a list of insecure registries to the spec.storageImport.insecureRegistries field.

    apiVersion: hco.kubevirt.io/v1beta1
    kind: HyperConverged
    metadata:
      name: kubevirt-hyperconverged
      namespace: openshift-cnv
    spec:
      storageImport:
        insecureRegistries: 1
          - "private-registry-example-1:5000"
          - "private-registry-example-2:5000"
    1
    Replace the examples in this list with valid registry hostnames.
8.18.16.4. Next steps

8.18.17. Preparing CDI scratch space

8.18.17.1. About data volumes

DataVolume objects are custom resources that are provided by the Containerized Data Importer (CDI) project. Data volumes orchestrate import, clone, and upload operations that are associated with an underlying persistent volume claim (PVC). Data volumes are integrated with OpenShift Virtualization, and they prevent a virtual machine from being started before the PVC has been prepared.

8.18.17.2. About scratch space

The Containerized Data Importer (CDI) requires scratch space (temporary storage) to complete some operations, such as importing and uploading virtual machine images. During this process, CDI provisions a scratch space PVC equal to the size of the PVC backing the destination data volume (DV). The scratch space PVC is deleted after the operation completes or aborts.

You can define the storage class that is used to bind the scratch space PVC in the spec.scratchSpaceStorageClass field of the HyperConverged custom resource.

If the defined storage class does not match a storage class in the cluster, then the default storage class defined for the cluster is used. If there is no default storage class defined in the cluster, the storage class used to provision the original DV or PVC is used.

Note

CDI requires requesting scratch space with a file volume mode, regardless of the PVC backing the origin data volume. If the origin PVC is backed by block volume mode, you must define a storage class capable of provisioning file volume mode PVCs.

Manual provisioning

If there are no storage classes, CDI uses any PVCs in the project that match the size requirements for the image. If there are no PVCs that match these requirements, the CDI import pod remains in a Pending state until an appropriate PVC is made available or until a timeout function kills the pod.

8.18.17.3. CDI operations that require scratch space
TypeReason

Registry imports

CDI must download the image to a scratch space and extract the layers to find the image file. The image file is then passed to QEMU-IMG for conversion to a raw disk.

Upload image

QEMU-IMG does not accept input from STDIN. Instead, the image to upload is saved in scratch space before it can be passed to QEMU-IMG for conversion.

HTTP imports of archived images

QEMU-IMG does not know how to handle the archive formats CDI supports. Instead, the image is unarchived and saved into scratch space before it is passed to QEMU-IMG.

HTTP imports of authenticated images

QEMU-IMG inadequately handles authentication. Instead, the image is saved to scratch space and authenticated before it is passed to QEMU-IMG.

HTTP imports of custom certificates

QEMU-IMG inadequately handles custom certificates of HTTPS endpoints. Instead, CDI downloads the image to scratch space before passing the file to QEMU-IMG.

8.18.17.4. Defining a storage class

You can define the storage class that the Containerized Data Importer (CDI) uses when allocating scratch space by adding the spec.scratchSpaceStorageClass field to the HyperConverged custom resource (CR).

Prerequisites

  • Install the OpenShift CLI (oc).

Procedure

  1. Edit the HyperConverged CR by running the following command:

    $ oc edit hco -n openshift-cnv kubevirt-hyperconverged
  2. Add the spec.scratchSpaceStorageClass field to the CR, setting the value to the name of a storage class that exists in the cluster:

    apiVersion: hco.kubevirt.io/v1beta1
    kind: HyperConverged
    metadata:
      name: kubevirt-hyperconverged
    spec:
      scratchSpaceStorageClass: "<storage_class>" 1
    1
    If you do not specify a storage class, CDI uses the storage class of the persistent volume claim that is being populated.
  3. Save and exit your default editor to update the HyperConverged CR.
8.18.17.5. CDI supported operations matrix

This matrix shows the supported CDI operations for content types against endpoints, and which of these operations requires scratch space.

Content typesHTTPHTTPSHTTP basic authRegistryUpload

KubeVirt (QCOW2)

✓ QCOW2
✓ GZ*
✓ XZ*

✓ QCOW2**
✓ GZ*
✓ XZ*

✓ QCOW2
✓ GZ*
✓ XZ*

✓ QCOW2*
□ GZ
□ XZ

✓ QCOW2*
✓ GZ*
✓ XZ*

KubeVirt (RAW)

✓ RAW
✓ GZ
✓ XZ

✓ RAW
✓ GZ
✓ XZ

✓ RAW
✓ GZ
✓ XZ

✓ RAW*
□ GZ
□ XZ

✓ RAW*
✓ GZ*
✓ XZ*

✓ Supported operation

□ Unsupported operation

* Requires scratch space

** Requires scratch space if a custom certificate authority is required

8.18.17.6. Additional resources

8.18.18. Re-using persistent volumes

To re-use a statically provisioned persistent volume (PV), you must first reclaim the volume. This involves deleting the PV so that the storage configuration can be re-used.

8.18.18.1. About reclaiming statically provisioned persistent volumes

When you reclaim a persistent volume (PV), you unbind the PV from a persistent volume claim (PVC) and delete the PV. Depending on the underlying storage, you might need to manually delete the shared storage.

You can then re-use the PV configuration to create a PV with a different name.

Statically provisioned PVs must have a reclaim policy of Retain to be reclaimed. If they do not, the PV enters a failed state when the PVC is unbound from the PV.

Important

The Recycle reclaim policy is deprecated in OpenShift Container Platform 4.

8.18.18.2. Reclaiming statically provisioned persistent volumes

Reclaim a statically provisioned persistent volume (PV) by unbinding the persistent volume claim (PVC) and deleting the PV. You might also need to manually delete the shared storage.

Reclaiming a statically provisioned PV is dependent on the underlying storage. This procedure provides a general approach that might need to be customized depending on your storage.

Procedure

  1. Ensure that the reclaim policy of the PV is set to Retain:

    1. Check the reclaim policy of the PV:

      $ oc get pv <pv_name> -o yaml | grep 'persistentVolumeReclaimPolicy'
    2. If the persistentVolumeReclaimPolicy is not set to Retain, edit the reclaim policy with the following command:

      $ oc patch pv <pv_name> -p '{"spec":{"persistentVolumeReclaimPolicy":"Retain"}}'
  2. Ensure that no resources are using the PV:

    $ oc describe pvc <pvc_name> | grep 'Mounted By:'

    Remove any resources that use the PVC before continuing.

  3. Delete the PVC to release the PV:

    $ oc delete pvc <pvc_name>
  4. Optional: Export the PV configuration to a YAML file. If you manually remove the shared storage later in this procedure, you can refer to this configuration. You can also use spec parameters in this file as the basis to create a new PV with the same storage configuration after you reclaim the PV:

    $ oc get pv <pv_name> -o yaml > <file_name>.yaml
  5. Delete the PV:

    $ oc delete pv <pv_name>
  6. Optional: Depending on the storage type, you might need to remove the contents of the shared storage folder:

    $ rm -rf <path_to_share_storage>
  7. Optional: Create a PV that uses the same storage configuration as the deleted PV. If you exported the reclaimed PV configuration earlier, you can use the spec parameters of that file as the basis for a new PV manifest:

    Note

    To avoid possible conflict, it is good practice to give the new PV object a different name than the one that you deleted.

    $ oc create -f <new_pv_name>.yaml

Additional resources

8.18.19. Deleting data volumes

You can manually delete a data volume by using the oc command-line interface.

Note

When you delete a virtual machine, the data volume it uses is automatically deleted.

8.18.19.1. About data volumes

DataVolume objects are custom resources that are provided by the Containerized Data Importer (CDI) project. Data volumes orchestrate import, clone, and upload operations that are associated with an underlying persistent volume claim (PVC). Data volumes are integrated with OpenShift Virtualization, and they prevent a virtual machine from being started before the PVC has been prepared.

8.18.19.2. Listing all data volumes

You can list the data volumes in your cluster by using the oc command-line interface.

Procedure

  • List all data volumes by running the following command:

    $ oc get dvs
8.18.19.3. Deleting a data volume

You can delete a data volume by using the oc command-line interface (CLI).

Prerequisites

  • Identify the name of the data volume that you want to delete.

Procedure

  • Delete the data volume by running the following command:

    $ oc delete dv <datavolume_name>
    Note

    This command only deletes objects that exist in the current project. Specify the -n <project_name> option if the object you want to delete is in a different project or namespace.

Chapter 9. Virtual machine templates

9.1. Creating virtual machine templates

9.1.1. About virtual machine templates

Preconfigured Red Hat virtual machine templates are listed in the Templates tab within the Virtualization page. These templates are available for different versions of Red Hat Enterprise Linux, Fedora, Microsoft Windows 10, and Microsoft Windows Servers. Each Red Hat virtual machine template is preconfigured with the operating system image, default settings for the operating system, flavor (CPU and memory), and workload type (server).

The Templates tab displays four types of virtual machine templates:

  • Red Hat Supported templates are fully supported by Red Hat.
  • User Supported templates are Red Hat Supported templates that were cloned and created by users.
  • Red Hat Provided templates have limited support from Red Hat.
  • User Provided templates are Red Hat Provided templates that were cloned and created by users.
Note

In the Templates tab, you cannot edit or delete Red Hat Supported or Red Hat Provided templates. You can only edit or delete custom virtual machine templates that were created by users.

Using a Red Hat template is convenient because the template is already preconfigured. When you select a Red Hat template to create your own custom template, the Create Virtual Machine Template wizard prompts you to add a boot source if a boot source was not added previously. Then, you can either save your custom template or continue to customize it and save it.

You can also select the Create Virtual Machine Template wizard directly and create a custom virtual machine template. The wizard prompts you to provide configuration details for the operating system, flavor, workload type, and other settings. You can add a boot source and continue to customize your template and save it.

9.1.2. About virtual machines and boot sources

Virtual machines consist of a virtual machine definition and one or more disks that are backed by data volumes. Virtual machine templates enable you to create virtual machines using predefined virtual machine specifications.

Every virtual machine template requires a boot source, which is a fully configured virtual machine disk image including configured drivers. Each virtual machine template contains a virtual machine definition with a pointer to the boot source. Each boot source has a predefined name and namespace. For some operating systems, a boot source is automatically provided. If it is not provided, then an administrator must prepare a custom boot source.

Provided boot sources are updated automatically to the latest version of the operating system. For auto-updated boot sources, persistent volume claims (PVCs) are created with the cluster’s default storage class. If you select a different default storage class after configuration, you must delete the existing data volumes in the cluster namespace that are configured with the previous default storage class.

To use the boot sources feature, install the latest release of OpenShift Virtualization. The namespace openshift-virtualization-os-images enables the feature and is installed with the OpenShift Virtualization Operator. Once the boot source feature is installed, you can create boot sources, attach them to templates, and create virtual machines from the templates.

Define a boot source by using a persistent volume claim (PVC) that is populated by uploading a local file, cloning an existing PVC, importing from a registry, or by URL. Attach a boot source to a virtual machine template by using the web console. After the boot source is attached to a virtual machine template, you create any number of fully configured ready-to-use virtual machines from the template.

9.1.3. Adding a boot source for a virtual machine template

A boot source can be configured for any virtual machine template that you want to use for creating virtual machines or custom templates. When virtual machine templates are configured with a boot source, they are labeled Available in the Templates tab. After you add a boot source to a template, you can create a new virtual machine from the template.

There are four methods for selecting and adding a boot source in the web console:

  • Upload local file (creates PVC)
  • Import via URL (creates PVC)
  • Clone existing PVC (creates PVC)
  • Import via Registry (creates PVC)

Prerequisites

  • To add a boot source, you must be logged in as a user with the os-images.kubevirt.io:edit RBAC role or as an administrator. You do not need special privileges to create a virtual machine from a template with a boot source added.
  • To upload a local file, the operating system image file must exist on your local machine.
  • To import via URL, access to the web server with the operating system image is required. For example: the Red Hat Enterprise Linux web page with images.
  • To clone an existing PVC, access to the project with a PVC is required.
  • To import via registry, access to the container registry is required.

Procedure

  1. In the OpenShift Virtualization console, click WorkloadsVirtualization from the side menu.
  2. Click the Templates tab.
  3. Identify the virtual machine template for which you want to configure a boot source and click Add source.
  4. In the Add boot source to template window, click Select boot source, select a method for creating a persistent volume claim (PVC): Upload local file, Import via URL, Clone existing PVC, or Import via Registry.
  5. Optional: Click This is a CD-ROM boot source to mount a CD-ROM and use it to install the operating system on to an empty disk. The additional empty disk is automatically created and mounted by OpenShift Virtualization. If the additional disk is not needed, you can remove it when you create the virtual machine.
  6. Enter a value for Persistent Volume Claim size to specify the PVC size that is adequate for the uncompressed image and any additional space that is required.

    1. Optional: Enter a name for Source provider to associate the name with this template.
    2. Optional: Advanced Storage settings: Click Storage class and select the storage class that is used to create the disk. Typically, this storage class is the default storage class that is created for use by all PVCs.

      Note

      Provided boot sources are updated automatically to the latest version of the operating system. For auto-updated boot sources, persistent volume claims (PVCs) are created with the cluster’s default storage class. If you select a different default storage class after configuration, you must delete the existing data volumes in the cluster namespace that are configured with the previous default storage class.

    3. Optional: Advanced Storage settings: Click Access mode and select an access mode for the persistent volume:

      • Single User (RWO) mounts the volume as read-write by a single node.
      • Shared Access (RWX) mounts the volume as read-write by many nodes.
      • Read Only (ROX) mounts the volume as read-only by many nodes.
    4. Optional: Advanced Storage settings: Click Volume mode if you want to select Block instead of the default value Filesystem. OpenShift Virtualization can statically provision raw block volumes. These volumes do not have a file system, and can provide performance benefits for applications that either write to the disk directly or implement their own storage service.
  7. Select the appropriate method to save your boot source:

    1. Click Save and upload if you uploaded a local file.
    2. Click Save and import if you imported content from a URL or the registry.
    3. Click Save and clone if you cloned an existing PVC.

Your custom virtual machine template with a boot source is listed in the Templates tab, and you can create virtual machines by using this template.

9.1.3.1. Virtual machine template fields for adding a boot source

The following table describes the fields for Add boot source to template window. This window displays when you click Add Source for a virtual machine template in the Templates tab.

NameParameterDescription

Boot source type

Upload local file (creates PVC)

Upload a file from your local device. Supported file types include gz, xz, tar, and qcow2.

Import via URL (creates PVC)

Import content from an image available from an HTTP or HTTPS endpoint. Obtain the download link URL from the web page where the image download is available and enter that URL link in the Import via URL (creates PVC) field. Example: For a Red Hat Enterprise Linux image, log on to the Red Hat Customer Portal, access the image download page, and copy the download link URL for the KVM guest image.

Clone existing PVC (creates PVC)

Use a PVC that is already available in the cluster and clone it.

Import via Registry (creates PVC)

Specify the bootable operating system container that is located in a registry and accessible from the cluster. Example: kubevirt/cirros-registry-dis-demo.

Source provider

 

Optional field. Add descriptive text about the source for the template or the name of the user who created the template. Example: Red Hat.

Advanced

Storage class

The storage class that is used to create the disk.

Access mode

Access mode of the persistent volume. Supported access modes are Single User (RWO), Shared Access (RWX), Read Only (ROX). If Single User (RWO) is selected, the disk can be mounted as read/write by a single node. If Shared Access (RWX) is selected, the disk can be mounted as read-write by many nodes. The kubevirt-storage-class-defaults config map provides access mode defaults for data volumes. The default value is set according to the best option for each storage class in the cluster.

+

Note

Shared Access (RWX) is required for some features, such as live migration of virtual machines between nodes.

Volume mode

Defines whether the persistent volume uses a formatted file system or raw block state. Supported modes are Block and Filesystem. The kubevirt-storage-class-defaults config map provides volume mode defaults for data volumes. The default value is set according to the best option for each storage class in the cluster.

9.1.4. Marking virtual machine templates as favorites

For easier access to virtual machine templates that are used frequently, you can mark those templates as favorites.

Procedure

  1. In the OpenShift Virtualization console, click WorkloadsVirtualization from the side menu.
  2. Click the Templates tab.
  3. Identify the Red Hat template that you want to mark as a favorite.
  4. Click the Options menu kebab and select Favorite template. The template moves up higher in the list of displayed templates.

9.1.5. Filtering the list of virtual machine templates by providers

In the Templates tab, you can use the Search by name field to search for virtual machine templates by specifying either the name of the template or a label that identfies the template. You can also filter templates by the provider, and display only those templates that meet your filtering criteria.

Procedure

  1. In the OpenShift Virtualization console, click WorkloadsVirtualization from the side menu.
  2. Click the Templates tab.
  3. To filter templates, click Filter.
  4. Select the appropriate checkbox from the list to filter the templates: Red Hat Supported, User Supported, Red Hat Provided, and User Provided.

9.1.6. Creating a virtual machine template with the wizard in the web console

The web console features the Create Virtual Machine Template wizard that guides you through the General, Networking, Storage, Advanced, and Review steps to simplify the process of creating virtual machine templates. All required fields are marked with a *. The Create Virtual Machine Template wizard prevents you from moving to the next step until you provide values in the required fields.

Note

The wizard guides you to create a custom virtual machine template where you specify the operating system, boot source, flavor, and other settings.

Procedure

  1. In the OpenShift Virtualization console, click WorkloadsVirtualization from the side menu.
  2. Click the Templates tab.
  3. Click Create and select Template with Wizard.
  4. Fill in all required fields in the General step.
  5. Click Next to progress to the Networking step. A NIC that is named nic0 is attached by default.

    1. Optional: Click Add Network Interface to create additional NICs.
    2. Optional: You can remove any or all NICs by clicking the Options menu kebab and selecting Delete. Virtual machines created from a template do not need a NIC attached. NICs can be created after a virtual machine has been created.
  6. Click Next to progress to the Storage step.
  7. Click Add Disk to add a disk, and complete your selections for the fields in the Add Disk screen.

    Note

    If Import via URL (creates PVC), Import via Registry (creates PVC), or Container (ephemeral) is selected as Source, a rootdisk disk is created and attached to the virtual machine as the Bootable Disk.

    A Bootable Disk is not required for virtual machines provisioned from a PXE source if there are no disks attached to the virtual machine. If one or more disks are attached to the virtual machine, you must select one as the Bootable Disk.

    Blank disks, PVC disks without a valid boot source, and the cloudinitdisk cannot be used as a boot source.

  8. Optional: Click Advanced to configure cloud-init and SSH access.

    Note

    Statically inject an SSH key by using the custom script in cloud-init or in the wizard. This allows you to securely and remotely manage virtual machines and manage and transfer information. This step is strongly recommended to secure your VM. 

  9. Click Review to review and confirm your settings.
  10. Click Create Virtual Machine template.
  11. Click See virtual machine template details to view details about the virtual machine template.

The template is also listed in the Templates tab.

9.1.7. Virtual machine template wizard fields

The following tables describe the fields for the General, Networking, Storage, and Advanced steps in the Create Virtual Machine Template wizard.

9.1.7.1. Virtual machine template wizard fields
NameParameterDescription

Template

 

Template from which to create the virtual machine. Selecting a template will automatically complete other fields.

Name

 

The name can contain lowercase letters (a-z), numbers (0-9), and hyphens (-), up to a maximum of 253 characters. The first and last characters must be alphanumeric. The name must not contain uppercase letters, spaces, periods (.), or special characters.

Template provider

 

The name of the user who is creating the template for the cluster or any meaningful name that identifies this template.

Template support

No additional support

This template does not have additional support in the cluster.

Support by template provider

This template is supported by the template provider.

Description

 

Optional description field.

Operating System

 

The operating system that is selected for the virtual machine. Selecting an operating system automatically selects the default Flavor and Workload Type for that operating system.

Boot Source

Import via URL (creates PVC)

Import content from an image available from an HTTP or HTTPS endpoint. Example: Obtaining a URL link from the web page with the operating system image.

Clone existing PVC (creates PVC)

Select an existent persistent volume claim available on the cluster and clone it.

Import via Registry (creates PVC)

Provision virtual machine from a bootable operating system container located in a registry accessible from the cluster. Example: kubevirt/cirros-registry-disk-demo.

PXE (network boot - adds network interface)

Boot an operating system from a server on the network. Requires a PXE bootable network attachment definition.

Persistent Volume Claim project

 

Project name that you want to use for cloning the PVC.

Persistent Volume Claim name

 

PVC name that should apply to this virtual machine template if you are cloning an existing PVC.

Mount this as a CD-ROM boot source

 

A CD-ROM requires an additional disk for installing the operating system. Select the checkbox to add a disk and customize it later.

Flavor

Tiny, Small, Medium, Large, Custom

Presets the amount of CPU and memory in a virtual machine template with predefined values that are allocated to the virtual machine, depending on the operating system associated with that template.

If you choose a default template, you can override the cpus and memsize values in the template using custom values to create a custom template. Alternatively, you can create a custom template by modifying the cpus and memsize values in the Details tab on the WorkloadsVirtualization page.

Workload Type

Note

If you choose the incorrect Workload Type, there could be performance or resource utilization issues (such as a slow UI).

Desktop

A virtual machine configuration for use on a desktop. Ideal for consumption on a small scale. Recommended for use with the web console. Use this template class or the Server template class to prioritize VM density over guaranteed VM performance.

Server

Balances performance and it is compatible with a wide range of server workloads. Use this template class or the Desktop template class to prioritize VM density over guaranteed VM performance.

High-Performance (requires CPU Manager)

A virtual machine configuration that is optimized for high-performance workloads. Use this template class to prioritize guaranteed VM performance over VM density.

9.1.7.2. Networking fields
NameDescription

Name

Name for the network interface controller.

Model

Indicates the model of the network interface controller. Supported values are e1000e and virtio.

Network

List of available network attachment definitions.

Type

List of available binding methods. For the default pod network, masquerade is the only recommended binding method. For secondary networks, use the bridge binding method. The masquerade method is not supported for non-default networks. Select SR-IOV if you configured an SR-IOV network device and defined that network in the namespace.

MAC Address

MAC address for the network interface controller. If a MAC address is not specified, one is assigned automatically.

9.1.7.3. Storage fields
NameSelectionDescription

Source

Blank (creates PVC)

Create an empty disk.

Import via URL (creates PVC)

Import content via URL (HTTP or HTTPS endpoint).

Use an existing PVC

Use a PVC that is already available in the cluster.

Clone existing PVC (creates PVC)

Select an existing PVC available in the cluster and clone it.

Import via Registry (creates PVC)

Import content via container registry.

Container (ephemeral)

Upload content from a container located in a registry accessible from the cluster. The container disk should be used only for read-only filesystems such as CD-ROMs or temporary virtual machines.

Name

 

Name of the disk. The name can contain lowercase letters (a-z), numbers (0-9), hyphens (-), and periods (.), up to a maximum of 253 characters. The first and last characters must be alphanumeric. The name must not contain uppercase letters, spaces, or special characters.

Size

 

Size of the disk in GiB.

Type

 

Type of disk. Example: Disk or CD-ROM

Interface

 

Type of disk device. Supported interfaces are virtIO, SATA, and SCSI.

Storage Class

 

The storage class that is used to create the disk.

Advanced storage settings

The following advanced storage settings are optional and available for Blank, Import via URL, and Clone existing PVC disks. Before OpenShift Virtualization 4.11, if you do not specify these parameters, the system uses the default values from the kubevirt-storage-class-defaults config map. In OpenShift Virtualization 4.11 and later, the system uses the default values from the storage profile.

Note

Use storage profiles to ensure consistent advanced storage settings when provisioning storage for OpenShift Virtualization.

To manually specify Volume Mode and Access Mode, you must clear the Apply optimized StorageProfile settings checkbox, which is selected by default.

NameMode descriptionParameterParameter description

Volume Mode

Defines whether the persistent volume uses a formatted file system or raw block state. Default is Filesystem.

Filesystem

Stores the virtual disk on a file system-based volume.

Block

Stores the virtual disk directly on the block volume. Only use Block if the underlying storage supports it.

Access Mode

Access mode of the persistent volume.

ReadWriteOnce (RWO)

Volume can be mounted as read-write by a single node.

ReadWriteMany (RWX)

Volume can be mounted as read-write by many nodes at one time.

Note

This is required for some features, such as live migration of virtual machines between nodes.

ReadOnlyMany (ROX)

Volume can be mounted as read only by many nodes.

9.1.7.4. Cloud-init fields
NameDescription

Hostname

Sets a specific hostname for the virtual machine.

Authorized SSH Keys

The user’s public key that is copied to ~/.ssh/authorized_keys on the virtual machine.

Custom script

Replaces other options with a field in which you paste a custom cloud-init script.

9.1.8. Additional resources

9.2. Editing virtual machine templates

You can update a virtual machine template in the web console, either by editing the full configuration in the YAML editor or by selecting a custom template in the Templates tab and modifying the editable items.

9.2.1. Editing a virtual machine template in the web console

Edit select values of a virtual machine template in the web console by clicking the pencil icon next to the relevant field. Other values can be edited using the CLI.

Labels and annotations are editable for both preconfigured Red Hat templates and your custom virtual machine templates. All other values are editable only for custom virtual machine templates that users have created using the Red Hat templates or the Create Virtual Machine Template wizard.

Procedure

  1. Click WorkloadsVirtualization from the side menu.
  2. Click the Templates tab.
  3. Select a virtual machine template.
  4. Click the VM Template Details tab.
  5. Click the pencil icon to make a field editable.
  6. Make the relevant changes and click Save.

Editing a virtual machine template will not affect virtual machines already created from that template.

9.2.2. Editing virtual machine template YAML configuration in the web console

You can edit the YAML configuration of a virtual machine template from the web console.

Some parameters cannot be modified. If you click Save with an invalid configuration, an error message indicates the parameter that cannot be modified.

Note

Navigating away from the YAML screen while editing cancels any changes to the configuration that you made.

Procedure

  1. In the OpenShift Virtualization console, click WorkloadsVirtualization from the side menu.
  2. Click the Templates tab.
  3. Select a template to open the VM Template Details screen.
  4. Click the YAML tab to display the editable configuration.
  5. Edit the file and click Save.

A confirmation message, which includes the updated version number for the object, shows that the YAML configuration was successfully edited.

9.2.3. Adding a virtual disk to a virtual machine template

Use this procedure to add a virtual disk to a virtual machine template.

Procedure

  1. Click WorkloadsVirtualization from the side menu.
  2. Click the Templates tab.
  3. Select a virtual machine template to open the VM Template Details screen.
  4. Click the Disks tab.
  5. In the Add Disk window, specify the Source, Name, Size, Type, Interface, and Storage Class.

    1. Advanced: You can enable preallocation if you use a blank disk source and require maximum write performance when creating data volumes. To do so, select the Enable preallocation checkbox.
    2. Optional: In the Advanced list, specify the Volume Mode and Access Mode for the virtual disk. If you do not specify these parameters, the system uses the default values from the kubevirt-storage-class-defaults config map.
  6. Click Add.

9.2.4. Adding a network interface to a virtual machine template

Use this procedure to add a network interface to a virtual machine template.

Procedure

  1. Click WorkloadsVirtualization from the side menu.
  2. Click the Templates tab.
  3. Select a virtual machine template to open the VM Template Details screen.
  4. Click the Network Interfaces tab.
  5. Click Add Network Interface.
  6. In the Add Network Interface window, specify the Name, Model, Network, Type, and MAC Address of the network interface.
  7. Click Add.

9.2.5. Editing CD-ROMs for Templates

Use the following procedure to edit CD-ROMs for virtual machine templates.

Procedure

  1. Click WorkloadsVirtualization from the side menu.
  2. Click the Templates tab.
  3. Select a virtual machine template to open the VM Template Details screen.
  4. Click the Disks tab.
  5. Click the Options menu kebab for the CD-ROM that you want to edit and select Edit.
  6. In the Edit CD-ROM window, edit the fields: Source, Persistent Volume Claim, Name, Type, and Interface.
  7. Click Save.

9.3. Enabling dedicated resources for virtual machine templates

Virtual machines can have resources of a node, such as CPU, dedicated to them to improve performance.

9.3.1. About dedicated resources

When you enable dedicated resources for your virtual machine, your virtual machine’s workload is scheduled on CPUs that will not be used by other processes. By using dedicated resources, you can improve the performance of the virtual machine and the accuracy of latency predictions.

9.3.2. Prerequisites

  • The CPU Manager must be configured on the node. Verify that the node has the cpumanager = true label before scheduling virtual machine workloads.

9.3.3. Enabling dedicated resources for a virtual machine template

You can enable dedicated resources for a virtual machine template in the Details tab. Virtual machines that were created by using a Red Hat template or the wizard can be enabled with dedicated resources.

Procedure

  1. Click WorkloadsVirtual Machine Templates from the side menu.
  2. Select a virtual machine template to open the Virtual Machine Template tab.
  3. Click the Details tab.
  4. Click the pencil icon to the right of the Dedicated Resources field to open the Dedicated Resources window.
  5. Select Schedule this workload with dedicated resources (guaranteed policy).
  6. Click Save.

9.4. Deleting a virtual machine template

Red Hat virtual machine templates cannot be deleted. You can use the web console to delete:

  • Virtual machine templates created from Red Hat templates
  • Custom virtual machine templates that were created by using the Create Virtual Machine Template wizard.

9.4.1. Deleting a virtual machine template in the web console

Deleting a virtual machine template permanently removes it from the cluster.

Note

You can delete virtual machine templates that were created by using a Red Hat template or the Create Virtual Machine Template wizard. Preconfigured virtual machine templates that are provided by Red Hat cannot be deleted.

Procedure

  1. In the OpenShift Virtualization console, click WorkloadsVirtualization from the side menu.
  2. Click the Templates tab. Select the appropriate method to delete a virtual machine template:

    • Click the Options menu kebab of the template to delete and select Delete Template.
    • Click the template name to open the Virtual Machine Template Details screen and click ActionsDelete Template.
  3. In the confirmation pop-up window, click Delete to permanently delete the template.

Chapter 10. Live migration

10.1. Virtual machine live migration

10.1.1. About live migration

Live migration is the process of moving a running virtual machine instance (VMI) to another node in the cluster without interrupting the virtual workload or access. If a VMI uses the LiveMigrate eviction strategy, it automatically migrates when the node that the VMI runs on is placed into maintenance mode. You can also manually start live migration by selecting a VMI to migrate.

You can use live migration if the following conditions are met:

  • Shared storage with ReadWriteMany (RWX) access mode.
  • Sufficient RAM and network bandwidth.
  • If the virtual machine uses a host model CPU, the nodes must support the virtual machine’s host model CPU.

By default, live migration traffic is encrypted using Transport Layer Security (TLS).

10.1.2. Updating access mode for live migration

For live migration to function properly, you must use the ReadWriteMany (RWX) access mode. Use this procedure to update the access mode, if needed.

Procedure

  • To set the RWX access mode, run the following oc patch command:

    $ oc patch -n openshift-cnv \
        cm kubevirt-storage-class-defaults \
        -p '{"data":{"'$<STORAGE_CLASS>'.accessMode":"ReadWriteMany"}}'

10.2. Live migration limits and timeouts

Apply live migration limits and timeouts so that migration processes do not overwhelm the cluster. Configure these settings by editing the HyperConverged custom resource (CR).

10.2.1. Configuring live migration limits and timeouts

Configure live migration limits and timeouts for the cluster by updating the HyperConverged custom resource (CR), which is located in the openshift-cnv namespace.

Procedure

  • Edit the HyperConverged CR and add the necessary live migration parameters.

    $ oc edit hco -n openshift-cnv kubevirt-hyperconverged

    Example configuration file

    apiVersion: hco.kubevirt.io/v1beta1
    kind: HyperConverged
    metadata:
      name: kubevirt-hyperconverged
      namespace: openshift-cnv
    spec:
      liveMigrationConfig: 1
        bandwidthPerMigration: 64Mi
        completionTimeoutPerGiB: 800
        parallelMigrationsPerCluster: 5
        parallelOutboundMigrationsPerNode: 2
        progressTimeout: 150

    1
    In this example, the spec.liveMigrationConfig array contains the default values for each field.
    Note

    You can restore the default value for any spec.liveMigrationConfig field by deleting that key/value pair and saving the file. For example, delete progressTimeout: <value> to restore the default progressTimeout: 150.

10.2.2. Cluster-wide live migration limits and timeouts

Table 10.1. Migration parameters
ParameterDescriptionDefault

parallelMigrationsPerCluster

Number of migrations running in parallel in the cluster.

5

parallelOutboundMigrationsPerNode

Maximum number of outbound migrations per node.

2

bandwidthPerMigration

Bandwidth limit of each migration, in MiB/s.

0 [1]

completionTimeoutPerGiB

The migration is canceled if it has not completed in this time, in seconds per GiB of memory. For example, a virtual machine instance with 6GiB memory times out if it has not completed migration in 4800 seconds. If the Migration Method is BlockMigration, the size of the migrating disks is included in the calculation.

800

progressTimeout

The migration is canceled if memory copy fails to make progress in this time, in seconds.

150

  1. The default value of 0 is unlimited.

10.3. Migrating a virtual machine instance to another node

Manually initiate a live migration of a virtual machine instance to another node using either the web console or the CLI.

10.3.1. Initiating live migration of a virtual machine instance in the web console

Migrate a running virtual machine instance to a different node in the cluster.

Note

The Migrate Virtual Machine action is visible to all users but only admin users can initiate a virtual machine migration.

Procedure

  1. In the OpenShift Virtualization console, click WorkloadsVirtualization from the side menu.
  2. Click the Virtual Machines tab.
  3. You can initiate the migration from this screen, which makes it easier to perform actions on multiple virtual machines in the one screen, or from the Virtual Machine Overview screen where you can view comprehensive details of the selected virtual machine:

    • Click the Options menu kebab at the end of virtual machine and select Migrate Virtual Machine.
    • Click the virtual machine name to open the Virtual Machine Overview screen and click ActionsMigrate Virtual Machine.
  4. Click Migrate to migrate the virtual machine to another node.

10.3.2. Initiating live migration of a virtual machine instance in the CLI

Initiate a live migration of a running virtual machine instance by creating a VirtualMachineInstanceMigration object in the cluster and referencing the name of the virtual machine instance.

Procedure

  1. Create a VirtualMachineInstanceMigration configuration file for the virtual machine instance to migrate. For example, vmi-migrate.yaml:

    apiVersion: kubevirt.io/v1
    kind: VirtualMachineInstanceMigration
    metadata:
      name: migration-job
    spec:
      vmiName: vmi-fedora
  2. Create the object in the cluster by running the following command:

    $ oc create -f vmi-migrate.yaml

The VirtualMachineInstanceMigration object triggers a live migration of the virtual machine instance. This object exists in the cluster for as long as the virtual machine instance is running, unless manually deleted.

10.4. Monitoring live migration of a virtual machine instance

You can monitor the progress of a live migration of a virtual machine instance from either the web console or the CLI.

10.4.1. Monitoring live migration of a virtual machine instance in the web console

For the duration of the migration, the virtual machine has a status of Migrating. This status is displayed in the Virtual Machines tab or in the Virtual Machine Overview screen for the migrating virtual machine.

Procedure

  1. In the OpenShift Virtualization console, click WorkloadsVirtualization from the side menu.
  2. Click the Virtual Machines tab.
  3. Select a virtual machine to open the Virtual Machine Overview screen.

10.4.2. Monitoring live migration of a virtual machine instance in the CLI

The status of the virtual machine migration is stored in the Status component of the VirtualMachineInstance configuration.

Procedure

  • Use the oc describe command on the migrating virtual machine instance:

    $ oc describe vmi vmi-fedora

    Example output

    ...
    Status:
      Conditions:
        Last Probe Time:       <nil>
        Last Transition Time:  <nil>
        Status:                True
        Type:                  LiveMigratable
      Migration Method:  LiveMigration
      Migration State:
        Completed:                    true
        End Timestamp:                2018-12-24T06:19:42Z
        Migration UID:                d78c8962-0743-11e9-a540-fa163e0c69f1
        Source Node:                  node2.example.com
        Start Timestamp:              2018-12-24T06:19:35Z
        Target Node:                  node1.example.com
        Target Node Address:          10.9.0.18:43891
        Target Node Domain Detected:  true

10.5. Cancelling the live migration of a virtual machine instance

Cancel the live migration so that the virtual machine instance remains on the original node.

You can cancel a live migration from either the web console or the CLI.

10.5.1. Cancelling live migration of a virtual machine instance in the web console

You can cancel a live migration of the virtual machine instance using the Options menu kebab found on each virtual machine in the VirtualizationVirtual Machines tab, or from the Actions menu available on all tabs in the Virtual Machine Overview screen.

Procedure

  1. In the OpenShift Virtualization console, click WorkloadsVirtualization from the side menu.
  2. Click the Virtual Machines tab.
  3. You can cancel the migration from this screen, which makes it easier to perform actions on multiple virtual machines, or from the Virtual Machine Overview screen where you can view comprehensive details of the selected virtual machine:

    • Click the Options menu kebab at the end of virtual machine and select Cancel Virtual Machine Migration.
    • Select a virtual machine name to open the Virtual Machine Overview screen and click ActionsCancel Virtual Machine Migration.
  4. Click Cancel Migration to cancel the virtual machine live migration.

10.5.2. Cancelling live migration of a virtual machine instance in the CLI

Cancel the live migration of a virtual machine instance by deleting the VirtualMachineInstanceMigration object associated with the migration.

Procedure

  • Delete the VirtualMachineInstanceMigration object that triggered the live migration, migration-job in this example:

    $ oc delete vmim migration-job

10.6. Configuring virtual machine eviction strategy

The LiveMigrate eviction strategy ensures that a virtual machine instance is not interrupted if the node is placed into maintenance or drained. Virtual machines instances with this eviction strategy will be live migrated to another node.

10.6.1. Configuring custom virtual machines with the LiveMigration eviction strategy

You only need to configure the LiveMigration eviction strategy on custom virtual machines. Common templates have this eviction strategy configured by default.

Procedure

  1. Add the evictionStrategy: LiveMigrate option to the spec.template.spec section in the virtual machine configuration file. This example uses oc edit to update the relevant snippet of the VirtualMachine configuration file:

    $ oc edit vm <custom-vm> -n <my-namespace>
    apiVersion: kubevirt.io/v1
    kind: VirtualMachine
    metadata:
      name: custom-vm
    spec:
      template:
        spec:
          evictionStrategy: LiveMigrate
    ...
  2. Restart the virtual machine for the update to take effect:

    $ virtctl restart <custom-vm> -n <my-namespace>

Chapter 11. Node maintenance

11.1. About node maintenance

11.1.1. About node maintenance mode

Nodes can be placed into maintenance mode using the oc adm utility, or using NodeMaintenance custom resources (CRs).

Placing a node into maintenance marks the node as unschedulable and drains all the virtual machines and pods from it. Virtual machine instances that have a LiveMigrate eviction strategy are live migrated to another node without loss of service. This eviction strategy is configured by default in virtual machine created from common templates but must be configured manually for custom virtual machines.

Virtual machine instances without an eviction strategy are shut down. Virtual machines with a RunStrategy of Running or RerunOnFailure are recreated on another node. Virtual machines with a RunStrategy of Manual are not automatically restarted.

Important

Virtual machines must have a persistent volume claim (PVC) with a shared ReadWriteMany (RWX) access mode to be live migrated.

When installed as part of OpenShift Virtualization, Node Maintenance Operator watches for new or deleted NodeMaintenance CRs. When a new NodeMaintenance CR is detected, no new workloads are scheduled and the node is cordoned off from the rest of the cluster. All pods that can be evicted are evicted from the node. When a NodeMaintenance CR is deleted, the node that is referenced in the CR is made available for new workloads.

Note

Using a NodeMaintenance CR for node maintenance tasks achieves the same results as the oc adm cordon and oc adm drain commands using standard OpenShift Container Platform custom resource processing.

11.1.2. Maintaining bare metal nodes

When you deploy OpenShift Container Platform on bare metal infrastructure, there are additional considerations that must be taken into account compared to deploying on cloud infrastructure. Unlike in cloud environments where the cluster nodes are considered ephemeral, re-provisioning a bare metal node requires significantly more time and effort for maintenance tasks.

When a bare metal node fails, for example, if a fatal kernel error happens or a NIC card hardware failure occurs, workloads on the failed node need to be restarted elsewhere else on the cluster while the problem node is repaired or replaced. Node maintenance mode allows cluster administrators to gracefully power down nodes, moving workloads to other parts of the cluster and ensuring workloads do not get interrupted. Detailed progress and node status details are provided during maintenance.

11.2. Setting a node to maintenance mode

Place a node into maintenance from the web console, CLI, or using a NodeMaintenance custom resource.

11.2.1. Setting a node to maintenance mode in the web console

Set a node to maintenance mode using the Options menu kebab found on each node in the ComputeNodes list, or using the Actions control of the Node Details screen.

Procedure

  1. In the OpenShift Virtualization console, click ComputeNodes.
  2. You can set the node to maintenance from this screen, which makes it easier to perform actions on multiple nodes in the one screen or from the Node Details screen where you can view comprehensive details of the selected node:

    • Click the Options menu kebab at the end of the node and select Start Maintenance.
    • Click the node name to open the Node Details screen and click ActionsStart Maintenance.
  3. Click Start Maintenance in the confirmation window.

The node will live migrate virtual machine instances that have the LiveMigration eviction strategy, and the node is no longer schedulable. All other pods and virtual machines on the node are deleted and recreated on another node.

11.2.2. Setting a node to maintenance mode in the CLI

Set a node to maintenance mode by marking it as unschedulable and using the oc adm drain command to evict or delete pods from the node.

Procedure

  1. Mark the node as unschedulable. The node status changes to NotReady,SchedulingDisabled.

    $ oc adm cordon <node1>
  2. Drain the node in preparation for maintenance. The node live migrates virtual machine instances that have the LiveMigratable condition set to True and the spec:evictionStrategy field set to LiveMigrate. All other pods and virtual machines on the node are deleted and recreated on another node.

    $ oc adm drain <node1> --delete-emptydir-data --ignore-daemonsets=true --force
    • The --delete-emptydir-data flag removes any virtual machine instances on the node that use emptyDir volumes. Data in these volumes is ephemeral and is safe to be deleted after termination.
    • The --ignore-daemonsets=true flag ensures that daemon sets are ignored and pod eviction can continue successfully.
    • The --force flag is required to delete pods that are not managed by a replica set or daemon set controller.

11.2.3. Setting a node to maintenance mode with a NodeMaintenance custom resource

You can put a node into maintenance mode with a NodeMaintenance custom resource (CR). When you apply a NodeMaintenance CR, all allowed pods are evicted and the node is shut down. Evicted pods are queued to be moved to another node in the cluster.

Prerequisites

  • Install the OpenShift Container Platform CLI oc.
  • Log in to the cluster as a user with cluster-admin privileges.

Procedure

  1. Create the following node maintenance CR, and save the file as nodemaintenance-cr.yaml:

    apiVersion: nodemaintenance.kubevirt.io/v1beta1
    kind: NodeMaintenance
    metadata:
      name: maintenance-example  1
    spec:
      nodeName: node-1.example.com 2
      reason: "Node maintenance" 3
    1
    Node maintenance CR name
    2
    The name of the node to be put into maintenance mode
    3
    Plain text description of the reason for maintenance
  2. Apply the node maintenance schedule by running the following command:

    $ oc apply -f nodemaintenance-cr.yaml
  3. Check the progress of the maintenance task by running the following command, replacing <node-name> with the name of your node:

    $ oc describe node <node-name>

    Example output

    Events:
      Type     Reason                     Age                   From     Message
      ----     ------                     ----                  ----     -------
      Normal   NodeNotSchedulable         61m                   kubelet  Node node-1.example.com status is now: NodeNotSchedulable

11.2.3.1. Checking status of current NodeMaintenance CR tasks

You can check the status of current NodeMaintenance CR tasks.

Prerequisites

  • Install the OpenShift Container Platform CLI oc.
  • Log in as a user with cluster-admin privileges.

Procedure

  • Check the status of current node maintenance tasks by running the following command:

    $ oc get NodeMaintenance -o yaml

    Example output

    apiVersion: v1
    items:
    - apiVersion: nodemaintenance.kubevirt.io/v1beta1
      kind: NodeMaintenance
      metadata:
    ...
      spec:
        nodeName: node-1.example.com
        reason: Node maintenance
      status:
        evictionPods: 3   1
        pendingPods:
        - pod-example-workload-0
        - httpd
        - httpd-manual
        phase: Running
        lastError: "Last failure message" 2
        totalpods: 5
    ...

    1
    evictionPods is the number of pods scheduled for eviction.
    2
    lastError records the latest eviction error, if any.

11.3. Resuming a node from maintenance mode

Resuming a node brings it out of maintenance mode and makes it schedulable again.

Resume a node from maintenance mode from the web console, CLI, or by deleting the NodeMaintenance custom resource.

11.3.1. Resuming a node from maintenance mode in the web console

Resume a node from maintenance mode using the Options menu kebab found on each node in the ComputeNodes list, or using the Actions control of the Node Details screen.

Procedure

  1. In the OpenShift Virtualization console, click ComputeNodes.
  2. You can resume the node from this screen, which makes it easier to perform actions on multiple nodes in the one screen, or from the Node Details screen where you can view comprehensive details of the selected node:

    • Click the Options menu kebab at the end of the node and select Stop Maintenance.
    • Click the node name to open the Node Details screen and click ActionsStop Maintenance.
  3. Click Stop Maintenance in the confirmation window.

The node becomes schedulable, but virtual machine instances that were running on the node prior to maintenance will not automatically migrate back to this node.

11.3.2. Resuming a node from maintenance mode in the CLI

Resume a node from maintenance mode by making it schedulable again.

Procedure

  • Mark the node as schedulable. You can then resume scheduling new workloads on the node.

    $ oc adm uncordon <node1>

11.3.3. Resuming a node from maintenance mode that was initiated with a NodeMaintenance CR

You can resume a node by deleting the NodeMaintenance CR.

Prerequisites

  • Install the OpenShift Container Platform CLI oc.
  • Log in to the cluster as a user with cluster-admin privileges.

Procedure

  • When your node maintenance task is complete, delete the active NodeMaintenance CR:

    $ oc delete -f nodemaintenance-cr.yaml

    Example output

    nodemaintenance.nodemaintenance.kubevirt.io "maintenance-example" deleted

11.4. Automatic renewal of TLS certificates

All TLS certificates for OpenShift Virtualization components are renewed and rotated automatically. You are not required to refresh them manually.

11.4.1. TLS certificates automatic renewal schedules

TLS certificates are automatically deleted and replaced according to the following schedule:

  • KubeVirt certificates are renewed daily.
  • Containerized Data Importer controller (CDI) certificates are renewed every 15 days.
  • MAC pool certificates are renewed every year.

Automatic TLS certificate rotation does not disrupt any operations. For example, the following operations continue to function without any disruption:

  • Migrations
  • Image uploads
  • VNC and console connections

11.5. Managing node labeling for obsolete CPU models

You can schedule a virtual machine (VM) on a node as long as the VM CPU model and policy are supported by the node.

11.5.1. About node labeling for obsolete CPU models

The OpenShift Virtualization Operator uses a predefined list of obsolete CPU models to ensure that a node supports only valid CPU models for scheduled VMs.

By default, the following CPU models are eliminated from the list of labels generated for the node:

Example 11.1. Obsolete CPU models

"486"
Conroe
athlon
core2duo
coreduo
kvm32
kvm64
n270
pentium
pentium2
pentium3
pentiumpro
phenom
qemu32
qemu64

This predefined list is not visible in the HyperConverged CR. You cannot remove CPU models from this list, but you can add to the list by editing the spec.obsoleteCPUs.cpuModels field of the HyperConverged CR.

11.5.2. About node labeling for CPU features

Through the process of iteration, the base CPU features in the minimum CPU model are eliminated from the list of labels generated for the node.

For example:

  • An environment might have two supported CPU models: Penryn and Haswell.
  • If Penryn is specified as the CPU model for minCPU, each base CPU feature for Penryn is compared to the list of CPU features supported by Haswell.

    Example 11.2. CPU features supported by Penryn

    apic
    clflush
    cmov
    cx16
    cx8
    de
    fpu
    fxsr
    lahf_lm
    lm
    mca
    mce
    mmx
    msr
    mtrr
    nx
    pae
    pat
    pge
    pni
    pse
    pse36
    sep
    sse
    sse2
    sse4.1
    ssse3
    syscall
    tsc

    Example 11.3. CPU features supported by Haswell

    aes
    apic
    avx
    avx2
    bmi1
    bmi2
    clflush
    cmov
    cx16
    cx8
    de
    erms
    fma
    fpu
    fsgsbase
    fxsr
    hle
    invpcid
    lahf_lm
    lm
    mca
    mce
    mmx
    movbe
    msr
    mtrr
    nx
    pae
    pat
    pcid
    pclmuldq
    pge
    pni
    popcnt
    pse
    pse36
    rdtscp
    rtm
    sep
    smep
    sse
    sse2
    sse4.1
    sse4.2
    ssse3
    syscall
    tsc
    tsc-deadline
    x2apic
    xsave
  • If both Penryn and Haswell support a specific CPU feature, a label is not created for that feature. Labels are generated for CPU features that are supported only by Haswell and not by Penryn.

    Example 11.4. Node labels created for CPU features after iteration

    aes
    avx
    avx2
    bmi1
    bmi2
    erms
    fma
    fsgsbase
    hle
    invpcid
    movbe
    pcid
    pclmuldq
    popcnt
    rdtscp
    rtm
    sse4.2
    tsc-deadline
    x2apic
    xsave

11.5.3. Configuring obsolete CPU models

You can configure a list of obsolete CPU models by editing the HyperConverged custom resource (CR).

Procedure

  • Edit the HyperConverged custom resource, specifying the obsolete CPU models in the obsoleteCPUs array. For example:

    apiVersion: hco.kubevirt.io/v1beta1
    kind: HyperConverged
    metadata:
      name: kubevirt-hyperconverged
      namespace: openshift-cnv
    spec:
      obsoleteCPUs:
        cpuModels: 1
          - "<obsolete_cpu_1>"
          - "<obsolete_cpu_2>"
        minCPUModel: "<minimum_cpu_model>" 2
    1
    Replace the example values in the cpuModels array with obsolete CPU models. Any value that you specify is added to a predefined list of obsolete CPU models. The predefined list is not visible in the CR.
    2
    Replace this value with the minimum CPU model that you want to use for basic CPU features. If you do not specify a value, Penryn is used by default.

11.6. Preventing node reconciliation

Use skip-node annotation to prevent the node-labeller from reconciling a node.

11.6.1. Using skip-node annotation

If you want the node-labeller to skip a node, annotate that node by using the oc CLI.

Prerequisites

  • You have installed the OpenShift CLI (oc).

Procedure

  • Annotate the node that you want to skip by running the following command:

    $ oc annotate node <node_name> node-labeller.kubevirt.io/skip-node=true 1
    1
    Replace <node_name> with the name of the relevant node to skip.

    Reconciliation resumes on the next cycle after the node annotation is removed or set to false.

11.6.2. Additional resources

Chapter 12. Node networking

12.1. Observing node network state

Node network state is the network configuration for all nodes in the cluster.

12.1.1. About nmstate

OpenShift Virtualization uses nmstate to report on and configure the state of the node network. This makes it possible to modify network policy configuration, such as by creating a Linux bridge on all nodes, by applying a single configuration manifest to the cluster.

Node networking is monitored and updated by the following objects:

NodeNetworkState
Reports the state of the network on that node.
NodeNetworkConfigurationPolicy
Describes the requested network configuration on nodes. You update the node network configuration, including adding and removing interfaces, by applying a NodeNetworkConfigurationPolicy manifest to the cluster.
NodeNetworkConfigurationEnactment
Reports the network policies enacted upon each node.

OpenShift Virtualization supports the use of the following nmstate interface types:

  • Linux Bridge
  • VLAN
  • Bond
  • Ethernet
Note

If your OpenShift Container Platform cluster uses OVN-Kubernetes as the default Container Network Interface (CNI) provider, you cannot attach a Linux bridge or bonding to the default interface of a host because of a change in the host network topology of OVN-Kubernetes. As a workaround, you can use a secondary network interface connected to your host, or switch to the OpenShift SDN default CNI provider.

12.1.2. Viewing the network state of a node

A NodeNetworkState object exists on every node in the cluster. This object is periodically updated and captures the state of the network for that node.

Procedure

  1. List all the NodeNetworkState objects in the cluster:

    $ oc get nns
  2. Inspect a NodeNetworkState object to view the network on that node. The output in this example has been redacted for clarity:

    $ oc get nns node01 -o yaml

    Example output

    apiVersion: nmstate.io/v1beta1
    kind: NodeNetworkState
    metadata:
      name: node01 1
    status:
      currentState: 2
        dns-resolver:
    ...
        interfaces:
    ...
        route-rules:
    ...
        routes:
    ...
      lastSuccessfulUpdateTime: "2020-01-31T12:14:00Z" 3

    1
    The name of the NodeNetworkState object is taken from the node.
    2
    The currentState contains the complete network configuration for the node, including DNS, interfaces, and routes.
    3
    Timestamp of the last successful update. This is updated periodically as long as the node is reachable and can be used to evalute the freshness of the report.

12.2. Updating node network configuration

You can update the node network configuration, such as adding or removing interfaces from nodes, by applying NodeNetworkConfigurationPolicy manifests to the cluster.

12.2.1. About nmstate

OpenShift Virtualization uses nmstate to report on and configure the state of the node network. This makes it possible to modify network policy configuration, such as by creating a Linux bridge on all nodes, by applying a single configuration manifest to the cluster.

Node networking is monitored and updated by the following objects:

NodeNetworkState
Reports the state of the network on that node.
NodeNetworkConfigurationPolicy
Describes the requested network configuration on nodes. You update the node network configuration, including adding and removing interfaces, by applying a NodeNetworkConfigurationPolicy manifest to the cluster.
NodeNetworkConfigurationEnactment
Reports the network policies enacted upon each node.

OpenShift Virtualization supports the use of the following nmstate interface types:

  • Linux Bridge
  • VLAN
  • Bond
  • Ethernet
Note

If your OpenShift Container Platform cluster uses OVN-Kubernetes as the default Container Network Interface (CNI) provider, you cannot attach a Linux bridge or bonding to the default interface of a host because of a change in the host network topology of OVN-Kubernetes. As a workaround, you can use a secondary network interface connected to your host, or switch to the OpenShift SDN default CNI provider.

12.2.2. Creating an interface on nodes

Create an interface on nodes in the cluster by applying a NodeNetworkConfigurationPolicy manifest to the cluster. The manifest details the requested configuration for the interface.

By default, the manifest applies to all nodes in the cluster. To add the interface to specific nodes, add the spec: nodeSelector parameter and the appropriate <key>:<value> for your node selector.

Procedure

  1. Create the NodeNetworkConfigurationPolicy manifest. The following example configures a Linux bridge on all worker nodes:

    apiVersion: nmstate.io/v1beta1
    kind: NodeNetworkConfigurationPolicy
    metadata:
      name: <br1-eth1-policy> 1
    spec:
      nodeSelector: 2
        node-role.kubernetes.io/worker: "" 3
      desiredState:
        interfaces:
          - name: br1
            description: Linux bridge with eth1 as a port 4
            type: linux-bridge
            state: up
            ipv4:
              dhcp: true
              enabled: true
            bridge:
              options:
                stp:
                  enabled: false
              port:
                - name: eth1
    1
    Name of the policy.
    2
    Optional: If you do not include the nodeSelector parameter, the policy applies to all nodes in the cluster.
    3
    This example uses the node-role.kubernetes.io/worker: "" node selector to select all worker nodes in the cluster.
    4
    Optional: Human-readable description for the interface.
  2. Create the node network policy:

    $ oc apply -f <br1-eth1-policy.yaml> 1
    1
    File name of the node network configuration policy manifest.
Additional resources

12.2.3. Confirming node network policy updates on nodes

A NodeNetworkConfigurationPolicy manifest describes your requested network configuration for nodes in the cluster. The node network policy includes your requested network configuration and the status of execution of the policy on the cluster as a whole.

When you apply a node network policy, a NodeNetworkConfigurationEnactment object is created for every node in the cluster. The node network configuration enactment is a read-only object that represents the status of execution of the policy on that node. If the policy fails to be applied on the node, the enactment for that node includes a traceback for troubleshooting.

Procedure

  1. To confirm that a policy has been applied to the cluster, list the policies and their status:

    $ oc get nncp
  2. Optional: If a policy is taking longer than expected to successfully configure, you can inspect the requested state and status conditions of a particular policy:

    $ oc get nncp <policy> -o yaml
  3. Optional: If a policy is taking longer than expected to successfully configure on all nodes, you can list the status of the enactments on the cluster:

    $ oc get nnce
  4. Optional: To view the configuration of a particular enactment, including any error reporting for a failed configuration:

    $ oc get nnce <node>.<policy> -o yaml

12.2.4. Removing an interface from nodes

You can remove an interface from one or more nodes in the cluster by editing the NodeNetworkConfigurationPolicy object and setting the state of the interface to absent.

Removing an interface from a node does not automatically restore the node network configuration to a previous state. If you want to restore the previous state, you will need to define that node network configuration in the policy.

If you remove a bridge or bonding interface, any node NICs in the cluster that were previously attached or subordinate to that bridge or bonding interface are placed in a down state and become unreachable. To avoid losing connectivity, configure the node NIC in the same policy so that it has a status of up and either DHCP or a static IP address.

Note

Deleting the node network policy that added an interface does not change the configuration of the policy on the node. Although a NodeNetworkConfigurationPolicy is an object in the cluster, it only represents the requested configuration.
Similarly, removing an interface does not delete the policy.

Procedure

  1. Update the NodeNetworkConfigurationPolicy manifest used to create the interface. The following example removes a Linux bridge and configures the eth1 NIC with DHCP to avoid losing connectivity:

    apiVersion: nmstate.io/v1beta1
    kind: NodeNetworkConfigurationPolicy
    metadata:
      name: <br1-eth1-policy> 1
    spec:
      nodeSelector: 2
        node-role.kubernetes.io/worker: "" 3
      desiredState:
        interfaces:
        - name: br1
          type: linux-bridge
          state: absent 4
        - name: eth1 5
          type: ethernet 6
          state: up 7
          ipv4:
            dhcp: true 8
            enabled: true 9
    1
    Name of the policy.
    2
    Optional: If you do not include the nodeSelector parameter, the policy applies to all nodes in the cluster.
    3
    This example uses the node-role.kubernetes.io/worker: "" node selector to select all worker nodes in the cluster.
    4
    Changing the state to absent removes the interface.
    5
    The name of the interface that is to be unattached from the bridge interface.
    6
    The type of interface. This example creates an Ethernet networking interface.
    7
    The requested state for the interface.
    8
    Optional: If you do not use dhcp, you can either set a static IP or leave the interface without an IP address.
    9
    Enables ipv4 in this example.
  2. Update the policy on the node and remove the interface:

    $ oc apply -f <br1-eth1-policy.yaml> 1
    1
    File name of the policy manifest.

12.2.5. Example policy configurations for different interfaces

12.2.5.1. Example: Linux bridge interface node network configuration policy

Create a Linux bridge interface on nodes in the cluster by applying a NodeNetworkConfigurationPolicy manifest to the cluster.

The following YAML file is an example of a manifest for a Linux bridge interface. It includes samples values that you must replace with your own information.

apiVersion: nmstate.io/v1beta1
kind: NodeNetworkConfigurationPolicy
metadata:
  name: br1-eth1-policy 1
spec:
  nodeSelector: 2
    kubernetes.io/hostname: <node01> 3
  desiredState:
    interfaces:
      - name: br1 4
        description: Linux bridge with eth1 as a port 5
        type: linux-bridge 6
        state: up 7
        ipv4:
          dhcp: true 8
          enabled: true 9
        bridge:
          options:
            stp:
              enabled: false 10
          port:
            - name: eth1 11
1
Name of the policy.
2
Optional: If you do not include the nodeSelector parameter, the policy applies to all nodes in the cluster.
3
This example uses a hostname node selector.
4
Name of the interface.
5
Optional: Human-readable description of the interface.
6
The type of interface. This example creates a bridge.
7
The requested state for the interface after creation.
8
Optional: If you do not use dhcp, you can either set a static IP or leave the interface without an IP address.
9
Enables ipv4 in this example.
10
Disables stp in this example.
11
The node NIC to which the bridge attaches.
12.2.5.2. Example: VLAN interface node network configuration policy

Create a VLAN interface on nodes in the cluster by applying a NodeNetworkConfigurationPolicy manifest to the cluster.

The following YAML file is an example of a manifest for a VLAN interface. It includes samples values that you must replace with your own information.

apiVersion: nmstate.io/v1beta1
kind: NodeNetworkConfigurationPolicy
metadata:
  name: vlan-eth1-policy 1
spec:
  nodeSelector: 2
    kubernetes.io/hostname: <node01> 3
  desiredState:
    interfaces:
    - name: eth1.102 4
      description: VLAN using eth1 5
      type: vlan 6
      state: up 7
      vlan:
        base-iface: eth1 8
        id: 102 9
1
Name of the policy.
2
Optional: If you do not include the nodeSelector parameter, the policy applies to all nodes in the cluster.
3
This example uses a hostname node selector.
4
Name of the interface.
5
Optional: Human-readable description of the interface.
6
The type of interface. This example creates a VLAN.
7
The requested state for the interface after creation.
8
The node NIC to which the VLAN is attached.
9
The VLAN tag.
12.2.5.3. Example: Bond interface node network configuration policy

Create a bond interface on nodes in the cluster by applying a NodeNetworkConfigurationPolicy manifest to the cluster.

Note

OpenShift Virtualization only supports the following bond modes:

  • mode=1 active-backup
  • mode=2 balance-xor
  • mode=4 802.3ad
  • mode=5 balance-tlb
  • mode=6 balance-alb

The following YAML file is an example of a manifest for a bond interface. It includes samples values that you must replace with your own information.

apiVersion: nmstate.io/v1beta1
kind: NodeNetworkConfigurationPolicy
metadata:
  name: bond0-eth1-eth2-policy 1
spec:
  nodeSelector: 2
    kubernetes.io/hostname: <node01> 3
  desiredState:
    interfaces:
    - name: bond0 4
      description: Bond with ports eth1 and eth2 5
      type: bond 6
      state: up 7
      ipv4:
        dhcp: true 8
        enabled: true 9
      link-aggregation:
        mode: active-backup 10
        options:
          miimon: '140' 11
        port: 12
        - eth1
        - eth2
      mtu: 1450 13
1
Name of the policy.
2
Optional: If you do not include the nodeSelector parameter, the policy applies to all nodes in the cluster.
3
This example uses a hostname node selector.
4
Name of the interface.
5
Optional: Human-readable description of the interface.
6
The type of interface. This example creates a bond.
7
The requested state for the interface after creation.
8
Optional: If you do not use dhcp, you can either set a static IP or leave the interface without an IP address.
9
Enables ipv4 in this example.
10
The driver mode for the bond. This example uses an active backup mode.
11
Optional: This example uses miimon to inspect the bond link every 140ms.
12
The subordinate node NICs in the bond.
13
Optional: The maximum transmission unit (MTU) for the bond. If not specified, this value is set to 1500 by default.
12.2.5.4. Example: Ethernet interface node network configuration policy

Configure an Ethernet interface on nodes in the cluster by applying a NodeNetworkConfigurationPolicy manifest to the cluster.

The following YAML file is an example of a manifest for an Ethernet interface. It includes sample values that you must replace with your own information.

apiVersion: nmstate.io/v1beta1
kind: NodeNetworkConfigurationPolicy
metadata:
  name: eth1-policy 1
spec:
  nodeSelector: 2
    kubernetes.io/hostname: <node01> 3
  desiredState:
    interfaces:
    - name: eth1 4
      description: Configuring eth1 on node01 5
      type: ethernet 6
      state: up 7
      ipv4:
        dhcp: true 8
        enabled: true 9
1
Name of the policy.
2
Optional: If you do not include the nodeSelector parameter, the policy applies to all nodes in the cluster.
3
This example uses a hostname node selector.
4
Name of the interface.
5
Optional: Human-readable description of the interface.
6
The type of interface. This example creates an Ethernet networking interface.
7
The requested state for the interface after creation.
8
Optional: If you do not use dhcp, you can either set a static IP or leave the interface without an IP address.
9
Enables ipv4 in this example.
12.2.5.5. Example: Multiple interfaces in the same node network configuration policy

You can create multiple interfaces in the same node network configuration policy. These interfaces can reference each other, allowing you to build and deploy a network configuration by using a single policy manifest.

The following example snippet creates a bond that is named bond10 across two NICs and a Linux bridge that is named br1 that connects to the bond.

#...
    interfaces:
    - name: bond10
      description: Bonding eth2 and eth3 for Linux bridge
      type: bond
      state: up
      link-aggregation:
        port:
        - eth2
        - eth3
    - name: br1
      description: Linux bridge on bond
      type: linux-bridge
      state: up
      bridge:
        port:
        - name: bond10
#...

12.2.6. Examples: IP management

The following example configuration snippets demonstrate different methods of IP management.

These examples use the ethernet interface type to simplify the example while showing the related context in the policy configuration. These IP management examples can be used with the other interface types.

12.2.6.1. Static

The following snippet statically configures an IP address on the Ethernet interface:

...
    interfaces:
    - name: eth1
      description: static IP on eth1
      type: ethernet
      state: up
      ipv4:
        dhcp: false
        address:
        - ip: 192.168.122.250 1
          prefix-length: 24
        enabled: true
...
1
Replace this value with the static IP address for the interface.
12.2.6.2. No IP address

The following snippet ensures that the interface has no IP address:

...
    interfaces:
    - name: eth1
      description: No IP on eth1
      type: ethernet
      state: up
      ipv4:
        enabled: false
...
12.2.6.3. Dynamic host configuration

The following snippet configures an Ethernet interface that uses a dynamic IP address, gateway address, and DNS:

...
    interfaces:
    - name: eth1
      description: DHCP on eth1
      type: ethernet
      state: up
      ipv4:
        dhcp: true
        enabled: true
...

The following snippet configures an Ethernet interface that uses a dynamic IP address but does not use a dynamic gateway address or DNS:

...
    interfaces:
    - name: eth1
      description: DHCP without gateway or DNS on eth1
      type: ethernet
      state: up
      ipv4:
        dhcp: true
        auto-gateway: false
        auto-dns: false
        enabled: true
...
12.2.6.4. DNS

The following snippet sets DNS configuration on the host.

...
    interfaces:
       ...
    dns-resolver:
      config:
        search:
        - example.com
        - example.org
        server:
        - 8.8.8.8
...
12.2.6.5. Static routing

The following snippet configures a static route and a static IP on interface eth1.

...
    interfaces:
    - name: eth1
      description: Static routing on eth1
      type: ethernet
      state: up
      ipv4:
        dhcp: false
        address:
        - ip: 192.0.2.251 1
          prefix-length: 24
        enabled: true
    routes:
      config:
      - destination: 198.51.100.0/24
        metric: 150
        next-hop-address: 192.0.2.1 2
        next-hop-interface: eth1
        table-id: 254
...
1
The static IP address for the Ethernet interface.
2
Next hop address for the node traffic. This must be in the same subnet as the IP address set for the Ethernet interface.

12.3. Troubleshooting node network configuration

If the node network configuration encounters an issue, the policy is automatically rolled back and the enactments report failure. This includes issues such as:

  • The configuration fails to be applied on the host.
  • The host loses connection to the default gateway.
  • The host loses connection to the API server.

12.3.1. Troubleshooting an incorrect node network configuration policy configuration

You can apply changes to the node network configuration across your entire cluster by applying a node network configuration policy. If you apply an incorrect configuration, you can use the following example to troubleshoot and correct the failed node network policy.

In this example, a Linux bridge policy is applied to an example cluster that has three control plane nodes (master) and three compute (worker) nodes. The policy fails to be applied because it references an incorrect interface. To find the error, investigate the available NMState resources. You can then update the policy with the correct configuration.

Procedure

  1. Create a policy and apply it to your cluster. The following example creates a simple bridge on the ens01 interface:

    apiVersion: nmstate.io/v1beta1
    kind: NodeNetworkConfigurationPolicy
    metadata:
      name: ens01-bridge-testfail
    spec:
      desiredState:
        interfaces:
          - name: br1
            description: Linux bridge with the wrong port
            type: linux-bridge
            state: up
            ipv4:
              dhcp: true
              enabled: true
            bridge:
              options:
                stp:
                  enabled: false
              port:
                - name: ens01
    $ oc apply -f ens01-bridge-testfail.yaml

    Example output

    nodenetworkconfigurationpolicy.nmstate.io/ens01-bridge-testfail created

  2. Verify the status of the policy by running the following command:

    $ oc get nncp

    The output shows that the policy failed:

    Example output

    NAME                    STATUS
    ens01-bridge-testfail   FailedToConfigure

    However, the policy status alone does not indicate if it failed on all nodes or a subset of nodes.

  3. List the node network configuration enactments to see if the policy was successful on any of the nodes. If the policy failed for only a subset of nodes, it suggests that the problem is with a specific node configuration. If the policy failed on all nodes, it suggests that the problem is with the policy.

    $ oc get nnce

    The output shows that the policy failed on all nodes:

    Example output

    NAME                                   STATUS
    control-plane-1.ens01-bridge-testfail        FailedToConfigure
    control-plane-2.ens01-bridge-testfail        FailedToConfigure
    control-plane-3.ens01-bridge-testfail        FailedToConfigure
    compute-1.ens01-bridge-testfail              FailedToConfigure
    compute-2.ens01-bridge-testfail              FailedToConfigure
    compute-3.ens01-bridge-testfail              FailedToConfigure

  4. View one of the failed enactments and look at the traceback. The following command uses the output tool jsonpath to filter the output:

    $ oc get nnce compute-1.ens01-bridge-testfail -o jsonpath='{.status.conditions[?(@.type=="Failing")].message}'

    This command returns a large traceback that has been edited for brevity:

    Example output

    error reconciling NodeNetworkConfigurationPolicy at desired state apply: , failed to execute nmstatectl set --no-commit --timeout 480: 'exit status 1' ''
    ...
    libnmstate.error.NmstateVerificationError:
    desired
    =======
    ---
    name: br1
    type: linux-bridge
    state: up
    bridge:
      options:
        group-forward-mask: 0
        mac-ageing-time: 300
        multicast-snooping: true
        stp:
          enabled: false
          forward-delay: 15
          hello-time: 2
          max-age: 20
          priority: 32768
      port:
      - name: ens01
    description: Linux bridge with the wrong port
    ipv4:
      address: []
      auto-dns: true
      auto-gateway: true
      auto-routes: true
      dhcp: true
      enabled: true
    ipv6:
      enabled: false
    mac-address: 01-23-45-67-89-AB
    mtu: 1500
    
    current
    =======
    ---
    name: br1
    type: linux-bridge
    state: up
    bridge:
      options:
        group-forward-mask: 0
        mac-ageing-time: 300
        multicast-snooping: true
        stp:
          enabled: false
          forward-delay: 15
          hello-time: 2
          max-age: 20
          priority: 32768
      port: []
    description: Linux bridge with the wrong port
    ipv4:
      address: []
      auto-dns: true
      auto-gateway: true
      auto-routes: true
      dhcp: true
      enabled: true
    ipv6:
      enabled: false
    mac-address: 01-23-45-67-89-AB
    mtu: 1500
    
    difference
    ==========
    --- desired
    +++ current
    @@ -13,8 +13,7 @@
           hello-time: 2
           max-age: 20
           priority: 32768
    -  port:
    -  - name: ens01
    +  port: []
     description: Linux bridge with the wrong port
     ipv4:
       address: []
      line 651, in _assert_interfaces_equal\n    current_state.interfaces[ifname],\nlibnmstate.error.NmstateVerificationError:

    The NmstateVerificationError lists the desired policy configuration, the current configuration of the policy on the node, and the difference highlighting the parameters that do not match. In this example, the port is included in the difference, which suggests that the problem is the port configuration in the policy.

  5. To ensure that the policy is configured properly, view the network configuration for one or all of the nodes by requesting the NodeNetworkState object. The following command returns the network configuration for the control-plane-1 node:

    $ oc get nns control-plane-1 -o yaml

    The output shows that the interface name on the nodes is ens1 but the failed policy incorrectly uses ens01:

    Example output

       - ipv4:
     ...
          name: ens1
          state: up
          type: ethernet

  6. Correct the error by editing the existing policy:

    $ oc edit nncp ens01-bridge-testfail
    ...
              port:
                - name: ens1

    Save the policy to apply the correction.

  7. Check the status of the policy to ensure it updated successfully:

    $ oc get nncp

    Example output

    NAME                    STATUS
    ens01-bridge-testfail   SuccessfullyConfigured

The updated policy is successfully configured on all nodes in the cluster.

Chapter 13. Logging, events, and monitoring

13.1. Viewing virtual machine logs

13.1.1. About virtual machine logs

Logs are collected for OpenShift Container Platform builds, deployments, and pods. In OpenShift Virtualization, virtual machine logs can be retrieved from the virtual machine launcher pod in either the web console or the CLI.

The -f option follows the log output in real time, which is useful for monitoring progress and error checking.

If the launcher pod is failing to start, use the --previous option to see the logs of the last attempt.

Warning

ErrImagePull and ImagePullBackOff errors can be caused by an incorrect deployment configuration or problems with the images that are referenced.

13.1.2. Viewing virtual machine logs in the CLI

Get virtual machine logs from the virtual machine launcher pod.

Procedure

  • Use the following command:

    $ oc logs <virt-launcher-name>

13.1.3. Viewing virtual machine logs in the web console

Get virtual machine logs from the associated virtual machine launcher pod.

Procedure

  1. In the OpenShift Virtualization console, click WorkloadsVirtualization from the side menu.
  2. Click the Virtual Machines tab.
  3. Select a virtual machine to open the Virtual Machine Overview screen.
  4. In the Details tab, click the virt-launcher-<name> pod in the Pod section.
  5. Click Logs.

13.2. Viewing events

13.2.1. About virtual machine events

OpenShift Container Platform events are records of important life-cycle information in a namespace and are useful for monitoring and troubleshooting resource scheduling, creation, and deletion issues.

OpenShift Virtualization adds events for virtual machines and virtual machine instances. These can be viewed from either the web console or the CLI.

See also: Viewing system event information in an OpenShift Container Platform cluster.

13.2.2. Viewing the events for a virtual machine in the web console

You can view the stream events for a running a virtual machine from the Virtual Machine Overview panel of the web console.

The ▮▮ button pauses the events stream.
The ▶ button continues a paused events stream.

Procedure

  1. Click WorkloadsVirtualization from the side menu.
  2. Click the Virtual Machines tab.
  3. Select a virtual machine to open the Virtual Machine Overview screen.
  4. Click Events to view all events for the virtual machine.

13.2.3. Viewing namespace events in the CLI

Use the OpenShift Container Platform client to get the events for a namespace.

Procedure

  • In the namespace, use the oc get command:

    $ oc get events

13.2.4. Viewing resource events in the CLI

Events are included in the resource description, which you can get using the OpenShift Container Platform client.

Procedure

  • In the namespace, use the oc describe command. The following example shows how to get the events for a virtual machine, a virtual machine instance, and the virt-launcher pod for a virtual machine:

    $ oc describe vm <vm>
    $ oc describe vmi <vmi>
    $ oc describe pod virt-launcher-<name>

13.3. Diagnosing data volumes using events and conditions

Use the oc describe command to analyze and help resolve issues with data volumes.

13.3.1. About conditions and events

Diagnose data volume issues by examining the output of the Conditions and Events sections generated by the command:

$ oc describe dv <DataVolume>

There are three Types in the Conditions section that display:

  • Bound
  • Running
  • Ready

The Events section provides the following additional information:

  • Type of event
  • Reason for logging
  • Source of the event
  • Message containing additional diagnostic information.

The output from oc describe does not always contains Events.

An event is generated when either Status, Reason, or Message changes. Both conditions and events react to changes in the state of the data volume.

For example, if you misspell the URL during an import operation, the import generates a 404 message. That message change generates an event with a reason. The output in the Conditions section is updated as well.

13.3.2. Analyzing data volumes using conditions and events

By inspecting the Conditions and Events sections generated by the describe command, you determine the state of the data volume in relation to persistent volume claims (PVCs), and whether or not an operation is actively running or completed. You might also receive messages that offer specific details about the status of the data volume, and how it came to be in its current state.

There are many different combinations of conditions. Each must be evaluated in its unique context.

Examples of various combinations follow.

  • Bound – A successfully bound PVC displays in this example.

    Note that the Type is Bound, so the Status is True. If the PVC is not bound, the Status is False.

    When the PVC is bound, an event is generated stating that the PVC is bound. In this case, the Reason is Bound and Status is True. The Message indicates which PVC owns the data volume.

    Message, in the Events section, provides further details including how long the PVC has been bound (Age) and by what resource (From), in this case datavolume-controller:

    Example output

    Status:
    	Conditions:
    		Last Heart Beat Time:  2020-07-15T03:58:24Z
    		Last Transition Time:  2020-07-15T03:58:24Z
    		Message:               PVC win10-rootdisk Bound
    		Reason:                Bound
    		Status:                True
    		Type:                  Bound
    
    	Events:
    		Type     Reason     Age    From                   Message
    		----     ------     ----   ----                   -------
    		Normal   Bound      24s    datavolume-controller  PVC example-dv Bound

  • Running – In this case, note that Type is Running and Status is False, indicating that an event has occurred that caused an attempted operation to fail, changing the Status from True to False.

    However, note that Reason is Completed and the Message field indicates Import Complete.

    In the Events section, the Reason and Message contain additional troubleshooting information about the failed operation. In this example, the Message displays an inability to connect due to a 404, listed in the Events section’s first Warning.

    From this information, you conclude that an import operation was running, creating contention for other operations that are attempting to access the data volume:

    Example output

    Status:
    	 Conditions:
    		 Last Heart Beat Time:  2020-07-15T04:31:39Z
    		 Last Transition Time:  2020-07-15T04:31:39Z
    		 Message:               Import Complete
    		 Reason:                Completed
    		 Status:                False
    		 Type:                  Running
    
    	Events:
    		Type     Reason           Age                From                   Message
    		----     ------           ----               ----                   -------
    		Warning  Error            12s (x2 over 14s)  datavolume-controller  Unable to connect
    		to http data source: expected status code 200, got 404. Status: 404 Not Found

  • Ready – If Type is Ready and Status is True, then the data volume is ready to be used, as in the following example. If the data volume is not ready to be used, the Status is False:

    Example output

    Status:
    	 Conditions:
    		 Last Heart Beat Time: 2020-07-15T04:31:39Z
    		 Last Transition Time:  2020-07-15T04:31:39Z
    		 Status:                True
    		 Type:                  Ready

13.4. Viewing information about virtual machine workloads

You can view high-level information about your virtual machines by using the Virtual Machines dashboard in the OpenShift Container Platform web console.

13.4.1. About the Virtual Machines dashboard

Access virtual machines from the OpenShift Container Platform web console by navigating to the WorkloadsVirtualization page. The WorkloadsVirtualization page contains two tabs:

  • Virtual Machines
  • Virtual Machine Templates

The following cards describe each virtual machine:

  • Details provides identifying information about the virtual machine, including:

    • Name
    • Namespace
    • Date of creation
    • Node name
    • IP address
  • Inventory lists the virtual machine’s resources, including:

    • Network interface controllers (NICs)
    • Disks
  • Status includes:

    • The current status of the virtual machine
    • A note indicating whether or not the QEMU guest agent is installed on the virtual machine
  • Utilization includes charts that display usage data for:

    • CPU
    • Memory
    • Filesystem
    • Network transfer
Note

Use the drop-down list to choose a duration for the utilization data. The available options are 1 Hour, 6 Hours, and 24 Hours.

  • Events lists messages about virtual machine activity over the past hour. To view additional events, click View all.

13.5. Monitoring virtual machine health

A virtual machine instance (VMI) can become unhealthy due to transient issues such as connectivity loss, deadlocks, or problems with external dependencies. A health check periodically performs diagnostics on a VMI by using any combination of the readiness and liveness probes.

13.5.1. About readiness and liveness probes

Use readiness and liveness probes to detect and handle unhealthy virtual machine instances (VMIs). You can include one or more probes in the specification of the VMI to ensure that traffic does not reach a VMI that is not ready for it and that a new instance is created when a VMI becomes unresponsive.

A readiness probe determines whether a VMI is ready to accept service requests. If the probe fails, the VMI is removed from the list of available endpoints until the VMI is ready.

A liveness probe determines whether a VMI is responsive. If the probe fails, the VMI is deleted and a new instance is created to restore responsiveness.

You can configure readiness and liveness probes by setting the spec.readinessProbe and the spec.livenessProbe fields of the VirtualMachineInstance object. These fields support the following tests:

HTTP GET
The probe determines the health of the VMI by using a web hook. The test is successful if the HTTP response code is between 200 and 399. You can use an HTTP GET test with applications that return HTTP status codes when they are completely initialized.
TCP socket
The probe attempts to open a socket to the VMI. The VMI is only considered healthy if the probe can establish a connection. You can use a TCP socket test with applications that do not start listening until initialization is complete.

13.5.2. Defining an HTTP readiness probe

Define an HTTP readiness probe by setting the spec.readinessProbe.httpGet field of the virtual machine instance (VMI) configuration.

Procedure

  1. Include details of the readiness probe in the VMI configuration file.

    Sample readiness probe with an HTTP GET test

    # ...
    spec:
      readinessProbe:
        httpGet: 1
          port: 1500 2
          path: /healthz 3
          httpHeaders:
          - name: Custom-Header
            value: Awesome
        initialDelaySeconds: 120 4
        periodSeconds: 20 5
        timeoutSeconds: 10 6
        failureThreshold: 3 7
        successThreshold: 3 8
    # ...

    1
    The HTTP GET request to perform to connect to the VMI.
    2
    The port of the VMI that the probe queries. In the above example, the probe queries port 1500.
    3
    The path to access on the HTTP server. In the above example, if the handler for the server’s /healthz path returns a success code, the VMI is considered to be healthy. If the handler returns a failure code, the VMI is removed from the list of available endpoints.
    4
    The time, in seconds, after the VMI starts before the readiness probe is initiated.
    5
    The delay, in seconds, between performing probes. The default delay is 10 seconds. This value must be greater than timeoutSeconds.
    6
    The number of seconds of inactivity after which the probe times out and the VMI is assumed to have failed. The default value is 1. This value must be lower than periodSeconds.
    7
    The number of times that the probe is allowed to fail. The default is 3. After the specified number of attempts, the pod is marked Unready.
    8
    The number of times that the probe must report success, after a failure, to be considered successful. The default is 1.
  2. Create the VMI by running the following command:

    $ oc create -f <file_name>.yaml

13.5.3. Defining a TCP readiness probe

Define a TCP readiness probe by setting the spec.readinessProbe.tcpSocket field of the virtual machine instance (VMI) configuration.

Procedure

  1. Include details of the TCP readiness probe in the VMI configuration file.

    Sample readiness probe with a TCP socket test

    ...
    spec:
      readinessProbe:
        initialDelaySeconds: 120 1
        periodSeconds: 20 2
        tcpSocket: 3
          port: 1500 4
        timeoutSeconds: 10 5
    ...

    1
    The time, in seconds, after the VMI starts before the readiness probe is initiated.
    2
    The delay, in seconds, between performing probes. The default delay is 10 seconds. This value must be greater than timeoutSeconds.
    3
    The TCP action to perform.
    4
    The port of the VMI that the probe queries.
    5
    The number of seconds of inactivity after which the probe times out and the VMI is assumed to have failed. The default value is 1. This value must be lower than periodSeconds.
  2. Create the VMI by running the following command:

    $ oc create -f <file_name>.yaml

13.5.4. Defining an HTTP liveness probe

Define an HTTP liveness probe by setting the spec.livenessProbe.httpGet field of the virtual machine instance (VMI) configuration. You can define both HTTP and TCP tests for liveness probes in the same way as readiness probes. This procedure configures a sample liveness probe with an HTTP GET test.

Procedure

  1. Include details of the HTTP liveness probe in the VMI configuration file.

    Sample liveness probe with an HTTP GET test

    # ...
    spec:
      livenessProbe:
        initialDelaySeconds: 120 1
        periodSeconds: 20 2
        httpGet: 3
          port: 1500 4
          path: /healthz 5
          httpHeaders:
          - name: Custom-Header
            value: Awesome
        timeoutSeconds: 10 6
    # ...

    1
    The time, in seconds, after the VMI starts before the liveness probe is initiated.
    2
    The delay, in seconds, between performing probes. The default delay is 10 seconds. This value must be greater than timeoutSeconds.
    3
    The HTTP GET request to perform to connect to the VMI.
    4
    The port of the VMI that the probe queries. In the above example, the probe queries port 1500. The VMI installs and runs a minimal HTTP server on port 1500 via cloud-init.
    5
    The path to access on the HTTP server. In the above example, if the handler for the server’s /healthz path returns a success code, the VMI is considered to be healthy. If the handler returns a failure code, the VMI is deleted and a new instance is created.
    6
    The number of seconds of inactivity after which the probe times out and the VMI is assumed to have failed. The default value is 1. This value must be lower than periodSeconds.
  2. Create the VMI by running the following command:

    $ oc create -f <file_name>.yaml

13.5.5. Template: Virtual machine configuration file for defining health checks

apiVersion: kubevirt.io/v1
kind: VirtualMachine
metadata:
  labels:
    special: vm-fedora
  name: vm-fedora
spec:
  template:
    metadata:
      labels:
        special: vm-fedora
    spec:
      domain:
        devices:
          disks:
          - disk:
              bus: virtio
            name: containerdisk
          - disk:
              bus: virtio
            name: cloudinitdisk
        resources:
          requests:
            memory: 1024M
      readinessProbe:
        httpGet:
          port: 1500
        initialDelaySeconds: 120
        periodSeconds: 20
        timeoutSeconds: 10
        failureThreshold: 3
        successThreshold: 3
      terminationGracePeriodSeconds: 180
      volumes:
      - name: containerdisk
        containerDisk:
          image: kubevirt/fedora-cloud-registry-disk-demo
      - cloudInitNoCloud:
          userData: |-
            #cloud-config
            password: fedora
            chpasswd: { expire: False }
            bootcmd:
              - setenforce 0
              - dnf install -y nmap-ncat
              - systemd-run --unit=httpserver nc -klp 1500 -e '/usr/bin/echo -e HTTP/1.1 200 OK\\n\\nHello World!'
        name: cloudinitdisk

13.5.6. Additional resources

13.6. Using the OpenShift Container Platform dashboard to get cluster information

Access the OpenShift Container Platform dashboard, which captures high-level information about the cluster, by clicking Home > Dashboards > Overview from the OpenShift Container Platform web console.

The OpenShift Container Platform dashboard provides various cluster information, captured in individual dashboard cards.

13.6.1. About the OpenShift Container Platform dashboards page

The OpenShift Container Platform dashboard consists of the following cards:

  • Details provides a brief overview of informational cluster details.

    Status include ok, error, warning, in progress, and unknown. Resources can add custom status names.

    • Cluster ID
    • Provider
    • Version
  • Cluster Inventory details number of resources and associated statuses. It is helpful when intervention is required to resolve problems, including information about:

    • Number of nodes
    • Number of pods
    • Persistent storage volume claims
    • Virtual machines (available if OpenShift Virtualization is installed)
    • Bare metal hosts in the cluster, listed according to their state (only available in metal3 environment).
  • Cluster Health summarizes the current health of the cluster as a whole, including relevant alerts and descriptions. If OpenShift Virtualization is installed, the overall health of OpenShift Virtualization is diagnosed as well. If more than one subsystem is present, click See All to view the status of each subsystem.
  • Cluster Capacity charts help administrators understand when additional resources are required in the cluster. The charts contain an inner ring that displays current consumption, while an outer ring displays thresholds configured for the resource, including information about:

    • CPU time
    • Memory allocation
    • Storage consumed
    • Network resources consumed
  • Cluster Utilization shows the capacity of various resources over a specified period of time, to help administrators understand the scale and frequency of high resource consumption.
  • Events lists messages related to recent activity in the cluster, such as pod creation or virtual machine migration to another host.
  • Top Consumers helps administrators understand how cluster resources are consumed. Click on a resource to jump to a detailed page listing pods and nodes that consume the largest amount of the specified cluster resource (CPU, memory, or storage).

13.7. Reviewing resource usage by virtual machines

Dashboards in the OpenShift Container Platform web console provide visual representations of cluster metrics to help you to quickly understand the state of your cluster. Dashboards belong to the monitoring stack that provides monitoring for core platform components.

The OpenShift Virtualization dashboard provides data on resource consumption for virtual machines and associated pods. The visualization metrics displayed in the OpenShift Virtualization dashboard are based on Prometheus Query Language (PromQL) queries.

A monitoring role is required to monitor user-defined namespaces in the OpenShift Virtualization dashboard.

13.7.1. About reviewing top consumers

In the OpenShift Virtualization dashboard, you can select a specific time period and view the top consumers of resources within that time period. Top consumers are virtual machines or virt-launcher pods that are consuming the highest amount of resources.

The following table shows resources monitored in the dashboard and describes the metrics associated with each resource for top consumers.

Monitored resources

Description

Memory swap traffic

Virtual machines consuming the most memory pressure when swapping memory.

vCPU wait

Virtual machines experiencing the maximum wait time (in seconds) for their vCPUs.

CPU usage by pod

The virt-launcher pods that are using the most CPU.

Network traffic

Virtual machines that are saturating the network by receiving the most amount of network traffic (in bytes).

Storage traffic

Virtual machines with the highest amount (in bytes) of storage-related traffic.

Storage IOPS

Virtual machines with the highest amount of I/O operations per second over a time period.

Memory usage

The virt-launcher pods that are using the most memory (in bytes).

Note

Viewing the maximum resource consumption is limited to the top five consumers.

13.7.2. Reviewing top consumers

In the Administrator perspective, you can view the OpenShift Virtualization dashboard where top consumers of resources are displayed.

Prerequisites

  • You have access to the cluster as a user with the cluster-admin role.

Procedure

  1. In the Administrator perspective in the OpenShift Virtualization web console, navigate to ObserveDashboards.
  2. Select the KubeVirt/Infrastructure Resources/Top Consumers dashboard from the Dashboard list.
  3. Select a predefined time period from the drop-down menu for Period. You can review the data for top consumers in the tables.
  4. Optional: Click Inspect to view or edit the Prometheus Query Language (PromQL) query associated with the top consumers for a table.

13.7.3. Additional resources

13.8. OpenShift Container Platform cluster monitoring, logging, and Telemetry

OpenShift Container Platform provides various resources for monitoring at the cluster level.

13.8.1. About OpenShift Container Platform monitoring

OpenShift Container Platform includes a pre-configured, pre-installed, and self-updating monitoring stack that provides monitoring for core platform components. OpenShift Container Platform delivers monitoring best practices out of the box. A set of alerts are included by default that immediately notify cluster administrators about issues with a cluster. Default dashboards in the OpenShift Container Platform web console include visual representations of cluster metrics to help you to quickly understand the state of your cluster.

After installing OpenShift Container Platform 4.9, cluster administrators can optionally enable monitoring for user-defined projects. By using this feature, cluster administrators, developers, and other users can specify how services and pods are monitored in their own projects. You can then query metrics, review dashboards, and manage alerting rules and silences for your own projects in the OpenShift Container Platform web console.

Note

Cluster administrators can grant developers and other users permission to monitor their own projects. Privileges are granted by assigning one of the predefined monitoring roles.

13.8.2. About logging subsystem components

The logging subsystem components include a collector deployed to each node in the OpenShift Container Platform cluster that collects all node and container logs and writes them to a log store. You can use a centralized web UI to create rich visualizations and dashboards with the aggregated data.

The major components of the logging subsystem are:

  • collection - This is the component that collects logs from the cluster, formats them, and forwards them to the log store. The current implementation is Fluentd.
  • log store - This is where the logs are stored. The default implementation is Elasticsearch. You can use the default Elasticsearch log store or forward logs to external log stores. The default log store is optimized and tested for short-term storage.
  • visualization - This is the UI component you can use to view logs, graphs, charts, and so forth. The current implementation is Kibana.

For more information on OpenShift Logging, see the OpenShift Logging documentation.

13.8.3. About Telemetry

Telemetry sends a carefully chosen subset of the cluster monitoring metrics to Red Hat. The Telemeter Client fetches the metrics values every four minutes and thirty seconds and uploads the data to Red Hat. These metrics are described in this document.

This stream of data is used by Red Hat to monitor the clusters in real-time and to react as necessary to problems that impact our customers. It also allows Red Hat to roll out OpenShift Container Platform upgrades to customers to minimize service impact and continuously improve the upgrade experience.

This debugging information is available to Red Hat Support and Engineering teams with the same restrictions as accessing data reported through support cases. All connected cluster information is used by Red Hat to help make OpenShift Container Platform better and more intuitive to use.

13.8.3.1. Information collected by Telemetry

The following information is collected by Telemetry:

13.8.3.1.1. System information
  • Version information, including the OpenShift Container Platform cluster version and installed update details that are used to determine update version availability
  • Update information, including the number of updates available per cluster, the channel and image repository used for an update, update progress information, and the number of errors that occur in an update
  • The unique random identifier that is generated during an installation
  • Configuration details that help Red Hat Support to provide beneficial support for customers, including node configuration at the cloud infrastructure level, hostnames, IP addresses, Kubernetes pod names, namespaces, and services
  • The OpenShift Container Platform framework components installed in a cluster and their condition and status
  • Events for all namespaces listed as "related objects" for a degraded Operator
  • Information about degraded software
  • Information about the validity of certificates
  • The name of the provider platform that OpenShift Container Platform is deployed on and the data center location
13.8.3.1.2. Sizing Information
  • Sizing information about clusters, machine types, and machines, including the number of CPU cores and the amount of RAM used for each
  • The number of running virtual machine instances in a cluster
  • The number of etcd members and the number of objects stored in the etcd cluster
  • Number of application builds by build strategy type
13.8.3.1.3. Usage information
  • Usage information about components, features, and extensions
  • Usage details about Technology Previews and unsupported configurations

Telemetry does not collect identifying information such as usernames or passwords. Red Hat does not intend to collect personal information. If Red Hat discovers that personal information has been inadvertently received, Red Hat will delete such information. To the extent that any telemetry data constitutes personal data, please refer to the Red Hat Privacy Statement for more information about Red Hat’s privacy practices.

13.8.4. CLI troubleshooting and debugging commands

For a list of the oc client troubleshooting and debugging commands, see the OpenShift Container Platform CLI tools documentation.

13.9. Prometheus queries for virtual resources

OpenShift Virtualization provides metrics for monitoring how infrastructure resources are consumed in the cluster. The metrics cover the following resources:

  • vCPU
  • Network
  • Storage
  • Guest memory swapping

Use the OpenShift Container Platform monitoring dashboard to query virtualization metrics.

13.9.1. Prerequisites

  • To use the vCPU metric, the schedstats=enable kernel argument must be applied to the MachineConfig object. This kernel argument enables scheduler statistics used for debugging and performance tuning and adds a minor additional load to the scheduler. See the OpenShift Container Platform machine configuration tasks documentation for more information on applying a kernel argument.
  • For guest memory swapping queries to return data, memory swapping must be enabled on the virtual guests.

13.9.2. Querying metrics

The OpenShift Container Platform monitoring dashboard enables you to run Prometheus Query Language (PromQL) queries to examine metrics visualized on a plot. This functionality provides information about the state of a cluster and any user-defined workloads that you are monitoring.

As a cluster administrator, you can query metrics for all core OpenShift Container Platform and user-defined projects.

As a developer, you must specify a project name when querying metrics. You must have the required privileges to view metrics for the selected project.

13.9.2.1. Querying metrics for all projects as a cluster administrator

As a cluster administrator or as a user with view permissions for all projects, you can access metrics for all default OpenShift Container Platform and user-defined projects in the Metrics UI.

Note

Only cluster administrators have access to the third-party UIs provided with OpenShift Container Platform Monitoring.

Prerequisites

  • You have access to the cluster as a user with the cluster-admin role or with view permissions for all projects.
  • You have installed the OpenShift CLI (oc).

Procedure

  1. In the Administrator perspective within the OpenShift Container Platform web console, select ObserveMetrics.
  2. Select Insert Metric at Cursor to view a list of predefined queries.
  3. To create a custom query, add your Prometheus Query Language (PromQL) query to the Expression field.
  4. To add multiple queries, select Add Query.
  5. To delete a query, select kebab next to the query, then choose Delete query.
  6. To disable a query from being run, select kebab next to the query and choose Disable query.
  7. Select Run Queries to run the queries that you have created. The metrics from the queries are visualized on the plot. If a query is invalid, the UI shows an error message.

    Note

    Queries that operate on large amounts of data might time out or overload the browser when drawing time series graphs. To avoid this, select Hide graph and calibrate your query using only the metrics table. Then, after finding a feasible query, enable the plot to draw the graphs.

  8. Optional: The page URL now contains the queries you ran. To use this set of queries again in the future, save this URL.

Additional resources

13.9.2.2. Querying metrics for user-defined projects as a developer

You can access metrics for a user-defined project as a developer or as a user with view permissions for the project.

In the Developer perspective, the Metrics UI includes some predefined CPU, memory, bandwidth, and network packet queries for the selected project. You can also run custom Prometheus Query Language (PromQL) queries for CPU, memory, bandwidth, network packet and application metrics for the project.

Note

Developers can only use the Developer perspective and not the Administrator perspective. As a developer, you can only query metrics for one project at a time. Developers cannot access the third-party UIs provided with OpenShift Container Platform monitoring that are for core platform components. Instead, use the Metrics UI for your user-defined project.

Prerequisites

  • You have access to the cluster as a developer or as a user with view permissions for the project that you are viewing metrics for.
  • You have enabled monitoring for user-defined projects.
  • You have deployed a service in a user-defined project.
  • You have created a ServiceMonitor custom resource definition (CRD) for the service to define how the service is monitored.

Procedure

  1. From the Developer perspective in the OpenShift Container Platform web console, select ObserveMetrics.
  2. Select the project that you want to view metrics for in the Project: list.
  3. Choose a query from the Select Query list, or run a custom PromQL query by selecting Show PromQL.

    Note

    In the Developer perspective, you can only run one query at a time.

Additional resources

13.9.3. Virtualization metrics

The following metric descriptions include example Prometheus Query Language (PromQL) queries. These metrics are not an API and might change between versions.

Note

The following examples use topk queries that specify a time period. If virtual machines are deleted during that time period, they can still appear in the query output.

13.9.3.1. vCPU metrics

The following query can identify virtual machines that are waiting for Input/Output (I/O):

kubevirt_vmi_vcpu_wait_seconds
Returns the wait time (in seconds) for a virtual machine’s vCPU.

A value above '0' means that the vCPU wants to run, but the host scheduler cannot run it yet. This inability to run indicates that there is an issue with I/O.

Note

To query the vCPU metric, the schedstats=enable kernel argument must first be applied to the MachineConfig object. This kernel argument enables scheduler statistics used for debugging and performance tuning and adds a minor additional load to the scheduler.

Example vCPU wait time query

topk(3, sum by (name, namespace) (rate(kubevirt_vmi_vcpu_wait_seconds[6m]))) > 0 1

1
This query returns the top 3 VMs waiting for I/O at every given moment over a six-minute time period.
13.9.3.2. Network metrics

The following queries can identify virtual machines that are saturating the network:

kubevirt_vmi_network_receive_bytes_total
Returns the total amount of traffic received (in bytes) on the virtual machine’s network.
kubevirt_vmi_network_transmit_bytes_total
Returns the total amount of traffic transmitted (in bytes) on the virtual machine’s network.

Example network traffic query

topk(3, sum by (name, namespace) (rate(kubevirt_vmi_network_receive_bytes_total[6m])) + sum by (name, namespace) (rate(kubevirt_vmi_network_transmit_bytes_total[6m]))) > 0 1

1
This query returns the top 3 VMs transmitting the most network traffic at every given moment over a six-minute time period.
13.9.3.3. Storage metrics
13.9.3.3.1. Storage-related traffic

The following queries can identify VMs that are writing large amounts of data:

kubevirt_vmi_storage_read_traffic_bytes_total
Returns the total amount (in bytes) of the virtual machine’s storage-related traffic.
kubevirt_vmi_storage_write_traffic_bytes_total
Returns the total amount of storage writes (in bytes) of the virtual machine’s storage-related traffic.

Example storage-related traffic query

topk(3, sum by (name, namespace) (rate(kubevirt_vmi_storage_read_traffic_bytes_total[6m])) + sum by (name, namespace) (rate(kubevirt_vmi_storage_write_traffic_bytes_total[6m]))) > 0 1

1
This query returns the top 3 VMs performing the most storage traffic at every given moment over a six-minute time period.
13.9.3.3.2. I/O performance

The following queries can determine the I/O performance of storage devices:

kubevirt_vmi_storage_iops_read_total
Returns the amount of write I/O operations the virtual machine is performing per second.
kubevirt_vmi_storage_iops_write_total
Returns the amount of read I/O operations the virtual machine is performing per second.

Example I/O performance query

topk(3, sum by (name, namespace) (rate(kubevirt_vmi_storage_iops_read_total[6m])) + sum by (name, namespace) (rate(kubevirt_vmi_storage_iops_write_total[6m]))) > 0 1

1
This query returns the top 3 VMs performing the most I/O operations per second at every given moment over a six-minute time period.
13.9.3.4. Guest memory swapping metrics

The following queries can identify which swap-enabled guests are performing the most memory swapping:

kubevirt_vmi_memory_swap_in_traffic_bytes_total
Returns the total amount (in bytes) of memory the virtual guest is swapping in.
kubevirt_vmi_memory_swap_out_traffic_bytes_total
Returns the total amount (in bytes) of memory the virtual guest is swapping out.

Example memory swapping query

topk(3, sum by (name, namespace) (rate(kubevirt_vmi_memory_swap_in_traffic_bytes_total[6m])) + sum by (name, namespace) (rate(kubevirt_vmi_memory_swap_out_traffic_bytes_total[6m]))) > 0 1

1
This query returns the top 3 VMs where the guest is performing the most memory swapping at every given moment over a six-minute time period.
Note

Memory swapping indicates that the virtual machine is under memory pressure. Increasing the memory allocation of the virtual machine can mitigate this issue.

13.9.4. Additional resources

13.10. Collecting data for Red Hat Support

When you submit a support case to Red Hat Support, it is helpful to provide debugging information for OpenShift Container Platform and OpenShift Virtualization by using the following tools:

must-gather tool
The must-gather tool collects diagnostic information, including resource definitions and service logs.
Prometheus
Prometheus is a time-series database and a rule evaluation engine for metrics. Prometheus sends alerts to Alertmanager for processing.
Alertmanager
The Alertmanager service handles alerts received from Prometheus. The Alertmanager is also responsible for sending the alerts to external notification systems.

13.10.1. Collecting data about your environment

Collecting data about your environment minimizes the time required to analyze and determine the root cause.

Prerequisites

  • Set the retention time for Prometheus metrics data to a minimum of seven days.
  • Configure the Alertmanager to capture relevant alerts and to send them to a dedicated mailbox so that they can be viewed and persisted outside the cluster.
  • Record the exact number of affected nodes and virtual machines.

Procedure

  1. Collect must-gather data for the cluster by using the default must-gather image.
  2. Collect must-gather data for Red Hat OpenShift Container Storage, if necessary.
  3. Collect must-gather data for OpenShift Virtualization by using the OpenShift Virtualization must-gather image.
  4. Collect Prometheus metrics for the cluster.
13.10.1.1. Additional resources

13.10.2. Collecting data about virtual machines

Collecting data about malfunctioning virtual machines (VMs) minimizes the time required to analyze and determine the root cause.

Prerequisites

  • Windows VMs:

    • Record the Windows patch update details for Red Hat Support.
    • Install the latest version of the VirtIO drivers. The VirtIO drivers include the QEMU guest agent.
    • If Remote Desktop Protocol (RDP) is enabled, try to connect to the VMs with RDP to determine whether there is a problem with the connection software.

Procedure

  1. Collect detailed must-gather data about the malfunctioning VMs.
  2. Collect screenshots of VMs that have crashed before you restart them.
  3. Record factors that the malfunctioning VMs have in common. For example, the VMs have the same host or network.
13.10.2.1. Additional resources

13.10.3. Using the must-gather tool for OpenShift Virtualization

You can collect data about OpenShift Virtualization resources by running the must-gather command with the OpenShift Virtualization image.

The default data collection includes information about the following resources:

  • OpenShift Virtualization Operator namespaces, including child objects
  • OpenShift Virtualization custom resource definitions
  • Namespaces that contain virtual machines
  • Basic virtual machine definitions

Procedure

  • Run the following command to collect data about OpenShift Virtualization:

    $ oc adm must-gather --image-stream=openshift/must-gather \
      --image=registry.redhat.io/container-native-virtualization/cnv-must-gather-rhel8:v{HCOVersion}
13.10.3.1. must-gather tool options

You can specify a combination of scripts and environment variables for the following options:

  • Collecting detailed virtual machine (VM) information from a namespace
  • Collecting detailed information about specified VMs
  • Collecting image and image stream information
  • Limiting the maximum number of parallel processes used by the must-gather tool
13.10.3.1.1. Parameters

Environment variables

You can specify environment variables for a compatible script.

NS=<namespace_name>
Collect virtual machine information, including virt-launcher pod details, from the namespace that you specify. The VirtualMachine and VirtualMachineInstance CR data is collected for all namespaces.
VM=<vm_name>
Collect details about a particular virtual machine. To use this option, you must also specify a namespace by using the NS environment variable.
PROS=<number_of_processes>

Modify the maximum number of parallel processes that the must-gather tool uses. The default value is 5.

Important

Using too many parallel processes can cause performance issues. Increasing the maximum number of parallel processes is not recommended.

Scripts

Each script is only compatible with certain environment variable combinations.

gather_vms_details
Collect VM log files, VM definitions, and namespaces (and their child objects) that belong to OpenShift Virtualization resources. If you use this parameter without specifying a namespace or VM, the must-gather tool collects this data for all VMs in the cluster. This script is compatible with all environment variables, but you must specify a namespace if you use the VM variable.
gather
Use the default must-gather script, which collects cluster data from all namespaces and includes only basic VM information. This script is only compatible with the PROS variable.
gather_images
Collect image and image stream custom resource information. This script is only compatible with the PROS variable.
13.10.3.1.2. Usage and examples

Environment variables are optional. You can run a script by itself or with one or more compatible environment variables.

Table 13.1. Compatible parameters
ScriptCompatible environment variable

gather_vms_details

  • For a namespace: NS=<namespace_name>
  • For a VM: VM=<vm_name> NS=<namespace_name>
  • PROS=<number_of_processes>

gather

  • PROS=<number_of_processes>

gather_images

  • PROS=<number_of_processes>

To customize the data that must-gather collects, you append a double dash (--) to the command, followed by a space and one or more compatible parameters.

Syntax

$ oc adm must-gather \
  --image=registry.redhat.io/container-native-virtualization/cnv-must-gather-rhel8:v4.9.7 \
  -- <environment_variable_1> <environment_variable_2> <script_name>

Detailed VM information

The following command collects detailed VM information for the my-vm VM in the mynamespace namespace:

$ oc adm must-gather \
  --image=registry.redhat.io/container-native-virtualization/cnv-must-gather-rhel8:v4.9.7 \
  -- NS=mynamespace VM=my-vm gather_vms_details 1
1
The NS environment variable is mandatory if you use the VM environment variable.

Default data collection limited to three parallel processes

The following command collects default must-gather information by using a maximum of three parallel processes:

$ oc adm must-gather \
  --image=registry.redhat.io/container-native-virtualization/cnv-must-gather-rhel8:v4.9.7 \
  -- PROS=3 gather

Image and image stream information

The following command collects image and image stream information from the cluster:

$ oc adm must-gather \
  --image=registry.redhat.io/container-native-virtualization/cnv-must-gather-rhel8:v4.9.7 \
  -- gather_images
13.10.3.2. Additional resources

Legal Notice

Copyright © 2024 Red Hat, Inc.

OpenShift documentation is licensed under the Apache License 2.0 (https://www.apache.org/licenses/LICENSE-2.0).

Modified versions must remove all Red Hat trademarks.

Portions adapted from https://github.com/kubernetes-incubator/service-catalog/ with modifications by Red Hat.

Red Hat, Red Hat Enterprise Linux, the Red Hat logo, the Shadowman logo, JBoss, OpenShift, Fedora, the Infinity logo, and RHCE are trademarks of Red Hat, Inc., registered in the United States and other countries.

Linux® is the registered trademark of Linus Torvalds in the United States and other countries.

Java® is a registered trademark of Oracle and/or its affiliates.

XFS® is a trademark of Silicon Graphics International Corp. or its subsidiaries in the United States and/or other countries.

MySQL® is a registered trademark of MySQL AB in the United States, the European Union and other countries.

Node.js® is an official trademark of Joyent. Red Hat Software Collections is not formally related to or endorsed by the official Joyent Node.js open source or commercial project.

The OpenStack® Word Mark and OpenStack logo are either registered trademarks/service marks or trademarks/service marks of the OpenStack Foundation, in the United States and other countries and are used with the OpenStack Foundation’s permission. We are not affiliated with, endorsed or sponsored by the OpenStack Foundation, or the OpenStack community.

All other trademarks are the property of their respective owners.

Red Hat logoGithubRedditYoutubeTwitter

Learn

Try, buy, & sell

Communities

About Red Hat Documentation

We help Red Hat users innovate and achieve their goals with our products and services with content they can trust.

Making open source more inclusive

Red Hat is committed to replacing problematic language in our code, documentation, and web properties. For more details, see the Red Hat Blog.

About Red Hat

We deliver hardened solutions that make it easier for enterprises to work across platforms and environments, from the core datacenter to the network edge.

© 2024 Red Hat, Inc.