Chapter 7. Known issues
This section documents known issues found in this release of Red Hat Ceph Storage.
7.1. The Cephadm utility
Adding or expanding iSCSI gateways in gwcli
across the iSCSI daemons works as expected
Previously, due to iSCSI daemons not being reconfigured automatically when a trusted IP list was updated in the specification file, adding or expanding iSCSI gateways in gwcli
would fail due to the iscsi-gateway.cfg
not matching across the iSCSI daemons.
With this fix, you can expand the gateways and add it to the existing gateways with gwcli
command. (BZ#2099470)
ceph orch ps
does not display a version for monitoring stack daemons
In cephadm
, due to the version grabbing code currently being incompatible with the downstream monitoring stack containers, version grabbing fails for monitoring stack daemons, such as node-exporter
, prometheus
, and alertmanager
.
As a workaround, if the user needs to find the version, the daemons' container names include the version.