B.4. Fujitsu Integrated Remote Management Controller (iRMC)
Fujitsu's iRMC is a Baseboard Management Controller (BMC) with integrated LAN connection and extended functionality. This driver focuses on the power management for bare metal systems connected to the iRMC.
Important
iRMC S4 or higher is required.
- pm_type
- Set this option to
pxe_irmc. - pm_user, pm_password
- The username and password for the iRMC interface.
- pm_addr
- The IP address of the iRMC interface.
- pm_port (Optional)
- The port to use for iRMC operations. The default is 443.
- pm_auth_method (Optional)
- The authentication method for iRMC operations. Use either
basicordigest. The default isbasic - pm_client_timeout (Optional)
- Timeout (in seconds) for iRMC operations. The default is 60 seconds.
- pm_sensor_method (Optional)
- Sensor data retrieval method. Use either
ipmitoolorscci. The default isipmitool.
Additional Notes
- Edit the
/etc/ironic/ironic.conffile and addpxe_irmcto theenabled_driversoption to enable this driver. - The director also requires an additional set of utilities if you enabled SCCI as the sensor method. Install the
python-scciclientpackage and restart theopenstack-ironic-conductorservice:yum install python-scciclient sudo systemctl restart openstack-ironic-conductor.service
$ yum install python-scciclient $ sudo systemctl restart openstack-ironic-conductor.serviceCopy to Clipboard Copied! Toggle word wrap Toggle overflow