8.10.5. Examples Using Clock Synchronization


Example 8.5. Clock synchronizing to local time with RTC and PIT timers

In this example. the clock is synchronized to local time with RTC and PIT timers
<clock offset="localtime">
	<timer name="rtc" tickpolicy="catchup" track="guest virtual machine" />
	<timer name="pit" tickpolicy="delay" />
	
</clock>
Copy to Clipboard Toggle word wrap

Note

The PIT clocksource can be used with a 32-bit guest running under a 64-bit host (which cannot use PIT), with the following conditions:
  • Guest virtual machine may have only one CPU
  • APIC timer must be disabled (use the "noapictimer" command line option)
  • NoHZ mode must be disabled in the guest (use the "nohz=off" command line option)
  • High resolution timer mode must be disabled in the guest (use the "highres=off" command line option)
  • The PIT clocksource is not compatible with either high resolution timer mode, or NoHz mode.
Retour au début
Red Hat logoGithubredditYoutubeTwitter

Apprendre

Essayez, achetez et vendez

Communautés

À propos de la documentation Red Hat

Nous aidons les utilisateurs de Red Hat à innover et à atteindre leurs objectifs grâce à nos produits et services avec un contenu auquel ils peuvent faire confiance. Découvrez nos récentes mises à jour.

Rendre l’open source plus inclusif

Red Hat s'engage à remplacer le langage problématique dans notre code, notre documentation et nos propriétés Web. Pour plus de détails, consultez le Blog Red Hat.

À propos de Red Hat

Nous proposons des solutions renforcées qui facilitent le travail des entreprises sur plusieurs plates-formes et environnements, du centre de données central à la périphérie du réseau.

Theme

© 2025 Red Hat