Ce contenu n'est pas disponible dans la langue sélectionnée.
6.4. Replacing a Missing Physical Volume
If a physical volume fails or otherwise needs to be replaced, you can label a new physical volume to replace the one that has been lost in the existing volume group by following the same procedure as you would for recovering physical volume metadata, described in Section 6.3, “Recovering Physical Volume Metadata”. You can use the
--partial
and --verbose
arguments of the vgdisplay
command to display the UUIDs and sizes of any physical volumes that are no longer present. If you wish to substitute another physical volume of the same size, you can use the pvcreate
command with the --restorefile
and --uuid
arguments to initialize a new device with the same UUID as the missing physical volume. You can then use the vgcfgrestore
command to restore the volume group's metadata.