Chapter 4. Testing Evacuation with Instance HA


Warning

The following procedure involves deliberately crashing a Compute node. Doing this forces the automated evacuation of instances through Instance HA.

  1. Boot one or more instances on the overcloud before crashing the Compute node that hosts the instances to test.

    stack@director $ . overcloudrc
    stack@director $ nova boot --image cirros --flavor 2 test-failover
    stack@director $ nova list --fields name,status,host
    Copy to Clipboard Toggle word wrap
  2. Log in to the Compute node that hosts the instances, using the compute-n format.

    stack@director $ . stackrc
    stack@director $ ssh -l heat-admin compute-n
    heat-admin@compute-n $
    Copy to Clipboard Toggle word wrap
  3. Crash the Compute node.

    heat-admin@compute-n $ echo c > /proc/sysrq-trigger
    Copy to Clipboard Toggle word wrap
  4. Wait a few minutes and then verify that these instances re-spawned on another Compute nodes.

    stack@director $ nova list --fields name,status,host
    stack@director $ nova service-list
    Copy to Clipboard Toggle word wrap
Retour au début
Red Hat logoGithubredditYoutubeTwitter

Apprendre

Essayez, achetez et vendez

Communautés

À propos de la documentation Red Hat

Nous aidons les utilisateurs de Red Hat à innover et à atteindre leurs objectifs grâce à nos produits et services avec un contenu auquel ils peuvent faire confiance. Découvrez nos récentes mises à jour.

Rendre l’open source plus inclusif

Red Hat s'engage à remplacer le langage problématique dans notre code, notre documentation et nos propriétés Web. Pour plus de détails, consultez le Blog Red Hat.

À propos de Red Hat

Nous proposons des solutions renforcées qui facilitent le travail des entreprises sur plusieurs plates-formes et environnements, du centre de données central à la périphérie du réseau.

Theme

© 2025 Red Hat