Chapter 5. Stretch clusters for Ceph storage
As a storage administrator, you can configure stretch clusters by entering stretch mode with 2-site clusters.
Red Hat Ceph Storage is capable of withstanding the loss of Ceph OSDs because of its network and cluster, which are equally reliable with failures randomly distributed across the CRUSH map. If a number of OSDs is shut down, the remaining OSDs and monitors still manage to operate.
However, this might not be the best solution for some stretched cluster configurations where a significant part of the Ceph cluster can use only a single network component. The example is a single cluster located in multiple data centers, for which the user wants to sustain a loss of a full data center.
The standard configuration is with two data centers. Other configurations are in clouds or availability zones. Each site holds two copies of the data, therefore, the replication size is four. The third site should have a tiebreaker monitor, this can be a virtual machine or high-latency compared to the main sites. This monitor chooses one of the sites to restore data if the network connection fails and both data centers remain active.
The standard Ceph configuration survives many failures of the network or data centers and it never compromises data consistency. If you restore enough Ceph servers following a failure, it recovers. Ceph maintains availability if you lose a data center, but can still form a quorum of monitors and have all the data available with enough copies to satisfy pools’ min_size, or CRUSH rules that replicate again to meet the size.
There are no additional steps to power down a stretch cluster. You can see the Powering down and rebooting Red Hat Ceph Storage cluster for more information.
Stretch cluster failures
Red Hat Ceph Storage never compromises on data integrity and consistency. If there is a network failure or a loss of nodes and the services can still be restored, Ceph returns to normal functionality on its own.
However, there are situations where you lose data availability even if you have enough servers available to meet Ceph’s consistency and sizing constraints, or where you unexpectedly do not meet the constraints.
First important type of failure is caused by inconsistent networks. If there is a network split, Ceph might be unable to mark OSD as down to remove it from the acting placement group (PG) sets despite the primary OSD being unable to replicate data. When this happens, the I/O is not permitted because Ceph cannot meet its durability guarantees.
The second important category of failures is when it appears that you have data replicated across data enters, but the constraints are not sufficient to guarantee this. For example, you might have data centers A and B, and the CRUSH rule targets three copies and places a copy in each data center with a min_size of 2. The PG might go active with two copies in site A and no copies in site B, which means that if you lose site A, you lose the data and Ceph cannot operate on it. This situation is difficult to avoid with standard CRUSH rules.
5.1. Stretch mode for a storage cluster Copia collegamentoCollegamento copiato negli appunti!
To configure stretch clusters, you must enter the stretch mode. When stretch mode is enabled, the Ceph OSDs only take PGs as active when they peer across data centers, or whichever other CRUSH bucket type you specified, assuming both are active. Pools increase in size from the default three to four, with two copies on each site.
In stretch mode, Ceph OSDs are only allowed to connect to monitors within the same data center. New monitors are not allowed to join the cluster without specified location.
If all the OSDs and monitors from a data center become inaccessible at once, the surviving data center will enter a degraded stretch mode. This issues a warning, reduces the min_size to 1, and allows the cluster to reach an active state with the data from the remaining site.
The degraded state also triggers warnings that the pools are too small, because the pool size does not get changed. However, a special stretch mode flag prevents the OSDs from creating extra copies in the remaining data center, therefore it still keeps 2 copies.
When the missing data center becomes accesible again, the cluster enters recovery stretch mode. This changes the warning and allows peering, but still requires only the OSDs from the data center, which was up the whole time.
When all PGs are in a known state and are not degraded or incomplete, the cluster goes back to the regular stretch mode, ends the warning, and restores min_size to its starting value 2. The cluster again requires both sites to peer, not only the site that stayed up the whole time, therefore you can fail over to the other site, if necessary.
Stretch mode limitations
- It is not possible to exit from stretch mode once it is entered.
- You cannot use erasure-coded pools with clusters in stretch mode. You can neither enter the stretch mode with erasure-coded pools, nor create an erasure-coded pool when the stretch mode is active.
- Stretch mode with no more than two sites is supported.
The weights of the two sites should be the same. If they are not, you receive the following error:
Example
[ceph: root@host01 /]# ceph mon enable_stretch_mode host05 stretch_rule datacenter Error EINVAL: the 2 datacenter instances in the cluster have differing weights 25947 and 15728 but stretch mode currently requires they be the same!To achieve same weights on both sites, the Ceph OSDs deployed in the two sites should be of equal size, that is, storage capacity in the first site is equivalent to storage capacity in the second site.
- While it is not enforced, you should run two Ceph monitors on each site and a tiebreaker, for a total of five. This is because OSDs can only connect to monitors in their own site when in stretch mode.
- You have to create your own CRUSH rule, which provides two copies on each site, which totals to four on both sites.
-
You cannot enable stretch mode if you have existing pools with non-default size or
min_size. -
Because the cluster runs with
min_size 1when degraded, you should only use stretch mode with all-flash OSDs. This minimizes the time needed to recover once connectivity is restored, and minimizes the potential for data loss.
5.1.1. Setting the CRUSH location for the daemons Copia collegamentoCollegamento copiato negli appunti!
Before you enter the stretch mode, you need to prepare the cluster by setting the CRUSH location to the daemons in the Red Hat Ceph Storage cluster. There are two ways to do this:
- Bootstrap the cluster through a service configuration file, where the locations are added to the hosts as part of deployment.
-
Set the locations manually through
ceph osd crush add-bucketandceph osd crush movecommands after the cluster is deployed.
Method 1: Bootstrapping the cluster
Prerequisites
- Root-level access to the nodes.
Procedure
If you are bootstrapping your new storage cluster, you can create the service configuration
.yamlfile that adds the nodes to the Red Hat Ceph Storage cluster and also sets specific labels for where the services should run:Example
service_type: host addr: host01 hostname: host01 location: root: default datacenter: DC1 labels: - osd - mon - mgr --- service_type: host addr: host02 hostname: host02 location: datacenter: DC1 labels: - osd - mon --- service_type: host addr: host03 hostname: host03 location: datacenter: DC1 labels: - osd - mds - rgw --- service_type: host addr: host04 hostname: host04 location: root: default datacenter: DC2 labels: - osd - mon - mgr --- service_type: host addr: host05 hostname: host05 location: datacenter: DC2 labels: - osd - mon --- service_type: host addr: host06 hostname: host06 location: datacenter: DC2 labels: - osd - mds - rgw --- service_type: host addr: host07 hostname: host07 labels: - mon --- service_type: mon placement: label: "mon" --- service_id: cephfs placement: label: "mds" --- service_type: mgr service_name: mgr placement: label: "mgr" --- service_type: osd service_id: all-available-devices service_name: osd.all-available-devices placement: label: "osd" spec: data_devices: all: true --- service_type: rgw service_id: objectgw service_name: rgw.objectgw placement: count: 2 label: "rgw" spec: rgw_frontend_port: 8080Bootstrap the storage cluster with the
--apply-specoption:Syntax
cephadm bootstrap --apply-spec CONFIGURATION_FILE_NAME --mon-ip MONITOR_IP_ADDRESS --ssh-private-key PRIVATE_KEY --ssh-public-key PUBLIC_KEY --registry-url REGISTRY_URL --registry-username USER_NAME --registry-password PASSWORDExample
[root@host01 ~]# cephadm bootstrap --apply-spec initial-config.yaml --mon-ip 10.10.128.68 --ssh-private-key /home/ceph/.ssh/id_rsa --ssh-public-key /home/ceph/.ssh/id_rsa.pub --registry-url registry.redhat.io --registry-username myuser1 --registry-password mypassword1ImportantYou can use different command options with the
cephadm bootstrapcommand. However, always include the--apply-specoption to use the service configuration file and configure the host locations.
Method 2: Setting the locations after the deployment
Prerequisites
- Root-level access to the nodes.
Procedure
Add two buckets to which you plan to set the location of your non-tiebreaker monitors to the CRUSH map, specifying the bucket type as as
datacenter:Syntax
ceph osd crush add-bucket BUCKET_NAME BUCKET_TYPEExample
[ceph: root@host01 /]# ceph osd crush add-bucket DC1 datacenter [ceph: root@host01 /]# ceph osd crush add-bucket DC2 datacenterMove the buckets under
root=default:Syntax
ceph osd crush move BUCKET_NAME root=defaultExample
[ceph: root@host01 /]# ceph osd crush move DC1 root=default [ceph: root@host01 /]# ceph osd crush move DC2 root=defaultMove the OSD hosts according to the required CRUSH placement:
Syntax
ceph osd crush move HOST datacenter=DATACENTERExample
[ceph: root@host01 /]# ceph osd crush move host01 datacenter=DC1
5.1.2. Entering the stretch mode Copia collegamentoCollegamento copiato negli appunti!
The new stretch mode is designed to handle two sites. There is a lower risk of component availability outages with 2-site clusters.
Prerequisites
- Root-level access to the nodes.
- The CRUSH location is set to the hosts.
Procedure
Set the location of each monitor, matching your CRUSH map:
Syntax
ceph mon set_location HOST datacenter=DATACENTERExample
[ceph: root@host01 /]# ceph mon set_location host01 datacenter=DC1 [ceph: root@host01 /]# ceph mon set_location host02 datacenter=DC1 [ceph: root@host01 /]# ceph mon set_location host04 datacenter=DC2 [ceph: root@host01 /]# ceph mon set_location host05 datacenter=DC2 [ceph: root@host01 /]# ceph mon set_location host07 datacenter=DC3Generate a CRUSH rule which places two copies on each data center:
Syntax
ceph osd getcrushmap > COMPILED_CRUSHMAP_FILENAME crushtool -d COMPILED_CRUSHMAP_FILENAME -o DECOMPILED_CRUSHMAP_FILENAMEExample
[ceph: root@host01 /]# ceph osd getcrushmap > crush.map.bin [ceph: root@host01 /]# crushtool -d crush.map.bin -o crush.map.txtEdit the decompiled CRUSH map file to add a new rule:
Example
rule stretch_rule { id 11 type replicated min_size 1 max_size 10 step take DC12 step chooseleaf firstn 2 type host step emit step take DC23 step chooseleaf firstn 2 type host step emit }NoteThis rule makes the cluster have read-affinity towards data center
DC1. Therefore, all the reads or writes happen through Ceph OSDs placed inDC1.If this is not desirable, and reads or writes are to be distributed evenly across the zones, the CRUSH rule is the following:
Example
rule stretch_rule { id 1 type replicated min_size 1 max_size 10 step take default step choose firstn 0 type datacenter step chooseleaf firstn 2 type host step emit }In this rule, the data center is selected randomly and automatically.
See CRUSH rules for more information on
firstnandindepoptions.
Inject the CRUSH map to make the rule available to the cluster:
Syntax
crushtool -c DECOMPILED_CRUSHMAP_FILENAME -o COMPILED_CRUSHMAP_FILENAME ceph osd setcrushmap -i COMPILED_CRUSHMAP_FILENAMEExample
[ceph: root@host01 /]# crushtool -c crush.map.txt -o crush2.map.bin [ceph: root@host01 /]# ceph osd setcrushmap -i crush2.map.binIf you do not run the monitors in connectivity mode, set the election strategy to
connectivity:Example
[ceph: root@host01 /]# ceph mon set election_strategy connectivityEnter stretch mode by setting the location of the tiebreaker monitor to split across the data centers:
Syntax
ceph mon set_location HOST datacenter=DATACENTER ceph mon enable_stretch_mode HOST stretch_rule datacenterExample
[ceph: root@host01 /]# ceph mon set_location host07 datacenter=DC3 [ceph: root@host01 /]# ceph mon enable_stretch_mode host07 stretch_rule datacenterIn this example the monitor
mon.host07is the tiebreaker.ImportantThe location of the tiebreaker monitor should differ from the data centers to which you previously set the non-tiebreaker monitors. In the example above, it is data center
DC3.ImportantDo not add this data center to the CRUSH map as it results in the following error when you try to enter stretch mode:
Error EINVAL: there are 3 datacenters in the cluster but stretch mode currently only works with 2!NoteIf you are writing your own tooling for deploying Ceph, you can use a new
--set-crush-locationoption when booting monitors, instead of running theceph mon set_locationcommand. This option accepts only a singlebucket=locationpair, for exampleceph-mon --set-crush-location 'datacenter=DC1', which must match the bucket type you specified when running theenable_stretch_modecommand.Verify that the stretch mode is enabled successfully:
Example
[ceph: root@host01 /]# ceph osd dump epoch 361 fsid 1234ab78-1234-11ed-b1b1-de456ef0a89d created 2023-01-16T05:47:28.482717+0000 modified 2023-01-17T17:36:50.066183+0000 flags sortbitwise,recovery_deletes,purged_snapdirs,pglog_hardlimit crush_version 31 full_ratio 0.95 backfillfull_ratio 0.92 nearfull_ratio 0.85 require_min_compat_client luminous min_compat_client luminous require_osd_release quincy stretch_mode_enabled true stretch_bucket_count 2 degraded_stretch_mode 0 recovering_stretch_mode 0 stretch_mode_bucket 8The
stretch_mode_enabledshould be set totrue. You can also see the number of stretch buckets, stretch mode buckets, and if the stretch mode is degraded or recovering.Verify that the monitors are in an appropriate locations:
Example
[ceph: root@host01 /]# ceph mon dump epoch 19 fsid 1234ab78-1234-11ed-b1b1-de456ef0a89d last_changed 2023-01-17T04:12:05.709475+0000 created 2023-01-16T05:47:25.631684+0000 min_mon_release 16 (pacific) election_strategy: 3 stretch_mode_enabled 1 tiebreaker_mon host07 disallowed_leaders host07 0: [v2:132.224.169.63:3300/0,v1:132.224.169.63:6789/0] mon.host07; crush_location {datacenter=DC3} 1: [v2:220.141.179.34:3300/0,v1:220.141.179.34:6789/0] mon.host04; crush_location {datacenter=DC2} 2: [v2:40.90.220.224:3300/0,v1:40.90.220.224:6789/0] mon.host01; crush_location {datacenter=DC1} 3: [v2:60.140.141.144:3300/0,v1:60.140.141.144:6789/0] mon.host02; crush_location {datacenter=DC1} 4: [v2:186.184.61.92:3300/0,v1:186.184.61.92:6789/0] mon.host05; crush_location {datacenter=DC2} dumped monmap epoch 19You can also see which monitor is the tiebreaker, and the monitor election strategy.
5.1.3. Adding OSD hosts in stretch mode Copia collegamentoCollegamento copiato negli appunti!
You can add Ceph OSDs in the stretch mode. The procedure is similar to the addition of the OSD hosts on a cluster where stretch mode is not enabled.
Prerequisites
- A running Red Hat Ceph Storage cluster.
- Stretch mode in enabled on a cluster.
- Root-level access to the nodes.
Procedure
List the available devices to deploy OSDs:
Syntax
ceph orch device ls [--hostname=HOST_1 HOST_2] [--wide] [--refresh]Example
[ceph: root@host01 /]# ceph orch device lsDeploy the OSDs on specific hosts or on all the available devices:
Create an OSD from a specific device on a specific host:
Syntax
ceph orch daemon add osd HOST:DEVICE_PATHExample
[ceph: root@host01 /]# ceph orch daemon add osd host03:/dev/sdbDeploy OSDs on any available and unused devices:
ImportantThis command creates collocated WAL and DB devices. If you want to create non-collocated devices, do not use this command.
Example
[ceph: root@host01 /]# ceph orch apply osd --all-available-devices
Move the OSD hosts under the CRUSH bucket:
Syntax
ceph osd crush move HOST datacenter=DATACENTERExample
[ceph: root@host01 /]# ceph osd crush move host03 datacenter=DC1 [ceph: root@host01 /]# ceph osd crush move host06 datacenter=DC2NoteEnsure you add the same topology nodes on both sites. Issues might arise if hosts are added only on one site.