37.2. Resizing an iSCSI Logical Unit


After modifying the online logical unit size, re-scan the logical unit to ensure that the system detects the updated size. To do this for iSCSI devices, use the following command:
# iscsiadm -m node --targetname target_name -R
Replace target_name with the name of the target where the device is located.

Note

You can also re-scan iSCSI logical units using the following command:
# iscsiadm -m node -R -I interface
Replace interface with the corresponding interface name of the resized logical unit (for example, iface0). This command performs two operations:
  • It scans for new devices in the same way that the command echo "- - -" > /sys/class/scsi_host/host/scan does (refer to Chapter 36, Scanning iSCSI Targets with Multiple LUNs or Portals).
  • It re-scans for new/modified logical units the same way that the command echo 1 > /sys/block/sdX/device/rescan does. Note that this command is the same one used for re-scanning fibre-channel logical units.
Red Hat logoGithubRedditYoutubeTwitter

Formazione

Prova, acquista e vendi

Community

Informazioni sulla documentazione di Red Hat

Aiutiamo gli utenti Red Hat a innovarsi e raggiungere i propri obiettivi con i nostri prodotti e servizi grazie a contenuti di cui possono fidarsi.

Rendiamo l’open source più inclusivo

Red Hat si impegna a sostituire il linguaggio problematico nel codice, nella documentazione e nelle proprietà web. Per maggiori dettagli, visita ilBlog di Red Hat.

Informazioni su Red Hat

Forniamo soluzioni consolidate che rendono più semplice per le aziende lavorare su piattaforme e ambienti diversi, dal datacenter centrale all'edge della rete.

© 2024 Red Hat, Inc.