qemu-kvm
component, BZ#1159613
If a virtio
device is created where the number of vectors is set to a value higher than 32, the device behaves as if it was set to a zero value on Red Hat Enterprise Linux 6, but not on Enterprise Linux 7. The resulting vector setting mismatch causes a migration error if the number of vectors on any virtio
device on either platform is set to 33 or higher. It is, therefore, not recommended to set the vector
value to be greater than 32.
qemu-kvm
component, BZ#1027582
Microsoft Windows 8.1 and Microsoft Windows Server 2012 R2 require some CPU features, for example Compare Exchange 8Byte and Compare Exchange 16Byte, which are not present in all qemu-kvm CPU models. As a consequence, Microsoft Windows 8.1 and Microsoft Windows Server 2012 R2 guests do not boot if they use the following CPU model definitions: Opteron_G1, Conroe, and kvm64. To work around this problem, use CPU models that include the features required by Microsoft Windows 8.1 and Microsoft Windows Server 2012 R2, for example Penryn, Nehalem, Westmere, SandyBridge, Haswell, Opteron_G2, Opteron_G3, Opteron_G4, or Opteron_G5.
kernel
component, BZ#1025868
KVM (Kernel-based Virtual Machine) cannot handle the values written in the MSR_IA32_MC4_CTL preprocessor macro by Linux guests when using some CPU or family model values. As a consequence, kernel panic occurs when booting on Red Hat Enterprise Linux 4 guests. Red Hat Enterprise Linux 5 and later incorrectly ignore certain exceptions so they are not affected. To work around this problem, use the nomce
kernel command-line option on the guest, which disables MCE support. Alternatively, use a different CPU model name on the virtual machine configuration. As a result, guests boot as expected and kernel panic no longer occurs.
kernel
component, BZ#1035571
After alternately hot plugging and unplugging SCSI disks more then three times, the guest displays information about the incorrect SCSI disk that has been removed. The work around this problem, the guest can need to wait for up to three minutes before it can rescan the bus to obtain correct information of the changed device.
virtio-win
component
When upgrading the NetKVM
driver through the Windows Device Manager, the old registry values are not removed. As a consequence, for example, non-existent parameters may be available.
qemu-kvm
component
When working with very large images (larger than 2TB) created with very small cluster sizes (for example, 512bytes), block I/O errors can occur due to timeouts in qemu. To prevent this problem from occurring, use the default cluster size of 64KiB or larger.
kernel
component
On Microsoft Windows Server 2012 containing large dynamic VHDX (Hyper-V virtual hard disk) files and using the ext3 file system, a call trace can appear, and, consequently, it is not possible to shut down the guest. To work around this problem, use the ext4 file system or set a logical block size of 1MB when creating a VHDX file. Note that this can only be done by using Microsoft PowerShell as the Hyper-V manager does not expose the –BlockSizeBytes option which has the default value of 32MB. To create a dynamix VHDX file with an approximate size of 2.5TB and 1MB block size run:
New-VHD –Path .\MyDisk.vhdx –SizeBytes 5120MB –BlockSizeBytes 1MB -Dynamic
libvirt
component
The storage drivers do not support the virsh vol-resize
command options --allocate
and --shrink
. Use of the --shrink
option will result in the following error message:
error: invalid argument: storageVolumeResize: unsupported flags (0x4)
Use of the --allocate
option will result in the following error message:
error: invalid argument: storageVolumeResize: unsupported flags (0x1)
Shrinking a volume's capacity is possible as long as the value provided on the command line is greater than the volume allocation value as seen with the virsh vol-info
command. You can shrink an existing volume by name through the followind sequence of steps:
Dump the XML of the larger volume into a file using the vol-dumpxml
.
Edit the file to change the name, path, and capacity values, where the capacity must be greater than or equal to the allocation.
Create a temporary smaller volume using the vol-create
with the edited XML file.
Back up and restore the larger volumes data using the vol-download
and vol-upload
commands to the smaller volume.
Use the vol-delete
command to remove the larger volume.
Use the vol-clone
command to restore the name from the larger volume.
Use the vol-delete
command to remove the temporary volume.
In order to allocate more space on the volume, follow a similar sequence, but adjust the allocation to a larger value than the existing volume.
virtio-win
component
It is not possible to downgrade a driver using the Search for the best driver in these locations
option because the newer and installed driver will be selected as the "best" driver. If you want to force installation of a particular driver version, use the Don't search
option and the Have Disk button to select the folder of the older driver. This method will allow you to install an older driver on a system that already has a driver installed.
virtio-win
component BZ#1052845
Performing Automatic System Recovery (ASR) on Windows 2003 guest system with virtio-blk attached system disk fails. To work around this issue, the following files need to be copied from virtio-win floppy image to ASR floppy image :
txtsetup.oem
,
disk1
,
\i386(amd64)\Win2003\*
kernel
component
There is a known issue with the Microsoft Hyper-V host. If a legacy network interface controller (NIC) is used on a multiple-CPU virtual machine, there is an interrupt problem in the emulated hardware when the IRQ balancing daemon is running. Call trace information is logged in the /var/log/messages
file.
libvirt
component, BZ#888635
Under certain circumstances, virtual machines try to boot from an incorrect device after a network boot failure. For more information, please refer to
this article on Customer Portal.
grubby
component, BZ#893390
When a Red Hat Enterprise Linux 6.4 guest updates the kernel and then the guest is turned off through Microsoft Hyper-V Manager, the guest fails to boot due to incomplete grub information. This is because the data is not synced properly to disk when the machine is turned off through Hyper-V Manager. To work around this problem, execute the sync
command before turning the guest off.
kernel
component
Using the mouse scroll wheel does not work on Red Hat Enterprise Linux 6.4 guests that run under certain version of Microsoft Hyper-V Manager. However, the scroll wheel works as expected when the vncviewer utility is used.
kernel
component, BZ#874406
Microsoft Windows Server 2012 guests using the e1000 driver can become unresponsive consuming 100% CPU during boot or reboot.
kernel
component
When a kernel panic is triggered on a Microsoft Hyper-V guest, the kdump utility does not capture the kernel error information; an error is only displayed on the command line. This is a host problem. Guest kdump works as expected on Microsoft Hyper-V 2012 R2 host.
quemu-kvm
component, BZ#871265
AMD Opteron G1, G2 or G3 CPU models on qemu-kvm use the family and models values as follows: family=15 and model=6. If these values are larger than 20, the lahfm_lm
CPU feature is ignored by Linux guests, even when the feature is enabled. To work around this problem, use a different CPU model, for example AMD Opteron G4.
qemu-kvm
component, BZ#860929
KVM guests must not be allowed to update the host CPU microcode. KVM does not allow this, and instead always returns the same microcode revision or patch level value to the guest. If the guest tries to update the CPU microcode, it will fail and show an error message similar to:
CPU0: update failed (for patch_level=0x6000624)
To work around this, configure the guest to not install CPU microcode updates; for example, uninstall the microcode_ctl package Red Hat Enterprise Linux of Fedora guests.
virt-p2v
component, BZ#816930
Converting a physical server running either Red Hat Enterprise Linux 4 or Red Hat Enterprise Linux 5 which has its file system root on an MD device is not supported. Converting such a guest results in a guest which fails to boot. Note that conversion of a Red Hat Enterprise Linux 6 server which has its root on an MD device is supported.
virt-p2v
component, BZ#808820
When converting a physical host with a multipath storage, Virt-P2V presents all available paths for conversion. Only a single path must be selected. This must be a currently active path.
virtio-win
component, BZ#615928
The balloon service on Windows 7 guests can only be started by the Administrator user.
virtio-win
component, BZ#612801
A Windows virtual machine must be restarted after the installation of the kernel Windows driver framework. If the virtual machine is not restarted, it may crash when a memory balloon operation is performed.
qemu-kvm
component, BZ#720597
Installation of Windows 7 Ultimate x86 (32-bit) Service Pack 1 on a guest with more than 4GB of RAM and more than one CPU from a DVD medium can lead to the system being unresponsive and, consequently, to a crash during the final steps of the installation process. To work around this issue, use the Windows Update utility to install the Service Pack.
qemu-kvm
component, BZ#612788
A dual function Intel 82576 Gigabit Ethernet Controller interface (codename: Kawela, PCI Vendor/Device ID: 8086:10c9) cannot have both physical functions (PF's) device-assigned to a Windows 2008 guest. Either physical function can be device assigned to a Windows 2008 guest (PCI function 0 or function 1), but not both.
virt-v2v
component, BZ#618091
The virt-v2v utility is able to convert guests running on an ESX server. However, if an ESX guest has a disk with a snapshot, the snapshot must be on the same datastore as the underlying disk storage. If the snapshot and the underlying storage are on different datastores, virt-v2v will report a 404 error while trying to retrieve the storage.
virt-v2v
component, BZ#678232
The VMware Tools application on Microsoft Windows is unable to disable itself when it detects that it is no longer running on a VMware platform. Consequently, converting a Microsoft Windows guest from VMware ESX, which has VMware Tools installed, will result in errors. These errors usually manifest as error messages on start-up, and a "Stop Error" (also known as a BSOD) when shutting down the guest. To work around this issue, uninstall VMware Tools on Microsoft Windows guests prior to conversion.
libguestfs
component
The libguestfs packages do not support remote access to disks over the network in Red Hat Enterprise Linux 6. Consequently, the virt-sysprep tool as well as other tools do not work with remote disks. Users who need to access disks remotely with tools such as virt-sysprep are advised to upgrade to Red Hat Enterprise Linux 7.