2.2. IPv6 デプロイメント用ノードの登録および検査
ノード定義のテンプレート (instackenv.json) は JSON ファイル形式で、ノード登録用のハードウェアおよび電源管理の情報が含まれています。以下に例を示します。
{
"nodes":[
{
"mac":[
"bb:bb:bb:bb:bb:bb"
],
"cpu":"4",
"memory":"6144",
"disk":"40",
"arch":"x86_64",
"pm_type":"pxe_ipmitool",
"pm_user":"admin",
"pm_password":"p@55w0rd!",
"pm_addr":"192.0.2.205"
},
{
"mac":[
"cc:cc:cc:cc:cc:cc"
],
"cpu":"4",
"memory":"6144",
"disk":"40",
"arch":"x86_64",
"pm_type":"pxe_ipmitool",
"pm_user":"admin",
"pm_password":"p@55w0rd!",
"pm_addr":"192.0.2.206"
},
{
"mac":[
"dd:dd:dd:dd:dd:dd"
],
"cpu":"4",
"memory":"6144",
"disk":"40",
"arch":"x86_64",
"pm_type":"pxe_ipmitool",
"pm_user":"admin",
"pm_password":"p@55w0rd!",
"pm_addr":"192.0.2.207"
},
{
"mac":[
"ee:ee:ee:ee:ee:ee"
],
"cpu":"4",
"memory":"6144",
"disk":"40",
"arch":"x86_64",
"pm_type":"pxe_ipmitool",
"pm_user":"admin",
"pm_password":"p@55w0rd!",
"pm_addr":"192.0.2.208"
}
{
"mac":[
"ff:ff:ff:ff:ff:ff"
],
"cpu":"4",
"memory":"6144",
"disk":"40",
"arch":"x86_64",
"pm_type":"pxe_ipmitool",
"pm_user":"admin",
"pm_password":"p@55w0rd!",
"pm_addr":"192.0.2.209"
}
{
"mac":[
"gg:gg:gg:gg:gg:gg"
],
"cpu":"4",
"memory":"6144",
"disk":"40",
"arch":"x86_64",
"pm_type":"pxe_ipmitool",
"pm_user":"admin",
"pm_password":"p@55w0rd!",
"pm_addr":"192.0.2.210"
}
]
}
前提条件
- アンダークラウドの正常なインストール。詳細は、Installing director on the undercloud を参照してください。
- オーバークラウドデプロイメントで利用可能なノード。
手順
ノード定義のテンプレートの作成後に、stack ユーザーのホームディレクトリー (
/home/stack/instackenv.json) にそのファイルを保存し、director にインポートします。$ openstack overcloud node import ~/instackenv.jsonこのコマンドはテンプレートをインポートし、テンプレートから director に各ノードを登録します。
カーネルと ramdisk イメージを全ノードに割り当てます。
$ openstack overcloud node configureこれで director でのノードの登録、設定が完了しました。
検証手順
ノードの登録後に、各ノードのハードウェア属性を確認します。
$ openstack overcloud node introspect --all-manageable重要ノードは
manageableの状態である必要があります。このプロセスが最後まで実行されて正常に終了したことを確認してください。ベアメタルノードの場合は、通常 15 分ほどかかります。