5.4.16.8.2. The warn RAID Fault Policy


In the following example, the raid_fault_policy field has been set to warn in the lvm.conf file. The RAID logical volume is laid out as follows.
# lvs -a -o name,copy_percent,devices my_vg
  LV               Copy%  Devices                                     
  my_lv            100.00 my_lv_rimage_0(0),my_lv_rimage_1(0),my_lv_rimage_2(0)
  [my_lv_rimage_0]        /dev/sdh1(1)                                
  [my_lv_rimage_1]        /dev/sdf1(1)                                
  [my_lv_rimage_2]        /dev/sdg1(1)                                
  [my_lv_rmeta_0]         /dev/sdh1(0)                                
  [my_lv_rmeta_1]         /dev/sdf1(0)                                
  [my_lv_rmeta_2]         /dev/sdg1(0)
Copy to Clipboard Toggle word wrap
If the /dev/sdh device fails, the system log will display error messages. In this case, however, LVM will not automatically attempt to repair the RAID device by replacing one of the images. Instead, if the device has failed you can replace the device with the --repair argument of the lvconvert command, as shown below.
# lvconvert --repair my_vg/my_lv
  /dev/sdh1: read failed after 0 of 2048 at 250994294784: Input/output error
  /dev/sdh1: read failed after 0 of 2048 at 250994376704: Input/output error
  /dev/sdh1: read failed after 0 of 2048 at 0: Input/output error
  /dev/sdh1: read failed after 0 of 2048 at 4096: Input/output error
  Couldn't find device with uuid fbI0YO-GX7x-firU-Vy5o-vzwx-vAKZ-feRxfF.
Attempt to replace failed RAID images (requires full device resync)? [y/n]: y

# lvs -a -o name,copy_percent,devices my_vg
  Couldn't find device with uuid fbI0YO-GX7x-firU-Vy5o-vzwx-vAKZ-feRxfF.
  LV               Copy%  Devices                                     
  my_lv             64.00 my_lv_rimage_0(0),my_lv_rimage_1(0),my_lv_rimage_2(0)
  [my_lv_rimage_0]        /dev/sde1(1)                                
  [my_lv_rimage_1]        /dev/sdf1(1)                                
  [my_lv_rimage_2]        /dev/sdg1(1)                                
  [my_lv_rmeta_0]         /dev/sde1(0)                                
  [my_lv_rmeta_1]         /dev/sdf1(0)                                
  [my_lv_rmeta_2]         /dev/sdg1(0)
Copy to Clipboard Toggle word wrap
Note that even though the failed device has been replaced, the display still indicates that LVM could not find the failed device. This is because, although the failed device has been removed from the RAID logical volume, the failed device has not yet been removed from the volume group. To remove the failed device from the volume group, you can execute vgreduce --removemissing VG.
If the device failure is a transient failure or you are able to repair the device that failed, as of Red Hat Enterprise Linux release 6.5 you can initiate recovery of the failed device with the --refresh option of the lvchange command. Previously it was necessary to deactivate and then activate the logical volume.
The following command refreshes a logical volume.
# lvchange --refresh my_vg/my_lv
Copy to Clipboard Toggle word wrap
맨 위로 이동
Red Hat logoGithubredditYoutubeTwitter

자세한 정보

평가판, 구매 및 판매

커뮤니티

Red Hat 문서 정보

Red Hat을 사용하는 고객은 신뢰할 수 있는 콘텐츠가 포함된 제품과 서비스를 통해 혁신하고 목표를 달성할 수 있습니다. 최신 업데이트를 확인하세요.

보다 포괄적 수용을 위한 오픈 소스 용어 교체

Red Hat은 코드, 문서, 웹 속성에서 문제가 있는 언어를 교체하기 위해 최선을 다하고 있습니다. 자세한 내용은 다음을 참조하세요.Red Hat 블로그.

Red Hat 소개

Red Hat은 기업이 핵심 데이터 센터에서 네트워크 에지에 이르기까지 플랫폼과 환경 전반에서 더 쉽게 작업할 수 있도록 강화된 솔루션을 제공합니다.

Theme

© 2025 Red Hat