이 콘텐츠는 선택한 언어로 제공되지 않습니다.
3.3. Basic SystemTap Handler Constructs
SystemTap supports the use of several basic constructs in handlers. The syntax for most of these handler constructs are mostly based on C and
awk
syntax. This section describes several of the most useful SystemTap handler constructs, which should provide you with enough information to write simple yet useful SystemTap scripts.
3.3.1. Variables
Variables can be used freely throughout a handler; simply choose a name, assign a value from a function or expression to it, and use it in an expression. SystemTap automatically identifies whether a variable should be typed as a string or integer, based on the type of the values assigned to it. For instance, if you set the variable
var
to gettimeofday_s()
(as in var = gettimeofday_s()
), then var
is typed as a number and can be printed in a printf()
with the integer format specifier (%d
).
Note, however, that by default variables are only local to the probe they are used in. This means that variables are initialized, used and disposed at each probe handler invocation. To share a variable between probes, declare the variable name using
global
outside of the probes. Consider the following example:
Example 3.8. timer-jiffies.stp
global count_jiffies, count_ms probe timer.jiffies(100) { count_jiffies ++ } probe timer.ms(100) { count_ms ++ } probe timer.ms(12345) { hz=(1000*count_jiffies) / count_ms printf ("jiffies:ms ratio %d:%d => CONFIG_HZ=%d\n", count_jiffies, count_ms, hz) exit () }
Example 3.8, “timer-jiffies.stp” computes the
CONFIG_HZ
setting of the kernel using timers that count jiffies and milliseconds, then computing accordingly. The global
statement allows the script to use the variables count_jiffies
and count_ms
(set in their own respective probes) to be shared with probe timer.ms(12345)
.
Note
The
++
notation in Example 3.8, “timer-jiffies.stp” (count_jiffies ++
and count_ms ++
) is used to increment the value of a variable by 1. In the following probe, count_jiffies
is incremented by 1 every 100 jiffies:
probe timer.jiffies(100) { count_jiffies ++ }
In this instance, SystemTap understands that
count_jiffies
is an integer. Because no initial value was assigned to count_jiffies
, its initial value is zero by default.
3.3.2. Conditional Statements
In some cases, the output of a SystemTap script may be too big. To address this, you need to further refine the script's logic in order to delimit the output into something more relevant or useful to your probe.
You can do this by using conditionals in handlers. SystemTap accepts the following types of conditional statements:
- If/Else Statements
- Format:
if (condition) statement1 else statement2
Thestatement1
is executed if thecondition
expression is non-zero. Thestatement2
is executed if thecondition
expression is zero. Theelse
clause (else
statement2) is optional. Bothstatement1
andstatement2
can be statement blocks.Example 3.9. ifelse.stp
global countread, countnonread probe kernel.function("vfs_read"),kernel.function("vfs_write") { if (probefunc()=="vfs_read") countread ++ else countnonread ++ } probe timer.s(5) { exit() } probe end { printf("VFS reads total %d\n VFS writes total %d\n", countread, countnonread) }
Example 3.9, “ifelse.stp” is a script that counts how many virtual file system reads (vfs_read
) and writes (vfs_write
) the system performs within a 5-second span. When run, the script increments the value of the variablecountread
by 1 if the name of the function it probed matchesvfs_read
(as noted by the conditionif (probefunc()=="vfs_read")
); otherwise, it incrementscountnonread
(else {countnonread ++}
). - While Loops
- Format:
while (condition) statement
So long ascondition
is non-zero the block of statements instatement
are executed. Thestatement
is often a statement block and it must change a value socondition
will eventually be zero. - For Loops
- Format:
for (initialization; conditional; increment) statement
Thefor
loop is simply shorthand for a while loop. The following is the equivalentwhile
loop:initialization while (conditional) { statement increment }
Conditional Operators
Aside from ==
(is equal to), you can also use the following operators in your conditional statements:
- >=
- Greater than or equal to
- <=
- Less than or equal to
- !=
- Is not equal to
3.3.3. Command-Line Arguments
You can also allow a SystemTap script to accept simple command-line arguments using a
$
or @
immediately followed by the number of the argument on the command line. Use $
if you are expecting the user to enter an integer as a command-line argument, and @
if you are expecting a string.
Example 3.10. commandlineargs.stp
probe kernel.function(@1) { } probe kernel.function(@1).return { }
Example 3.10, “commandlineargs.stp” is similar to Example 3.1, “wildcards.stp”, except that it allows you to pass the kernel function to be probed as a command-line argument (as in
stap commandlineargs.stp kernel function
). You can also specify the script to accept multiple command-line arguments, noting them as @1
, @2
, and so on, in the order they are entered by the user.