7.19. biosdevname


Updated biosdevname packages that fix several bugs and add various enhancements are now available for Red Hat Enterprise Linux 6.
The biosdevname packages contain an optional convention for naming network interfaces, which assigns names to network interfaces based on their physical location. The biosdevname utility is disabled by default, except for a limited set of Dell PowerEdge, C Series, and Precision Workstation systems.

Note

The biosdevname packages have been upgraded to upstream version 0.6.2, which provides a number of bug fixes and enhancements over the previous version. Notably, it provides the *dev_port* attribute for a new Mellanox driver and allowing naming of FCoE devices to be ignored. (BZ#1158564)

Bug Fixes

BZ#1133523
Previously, the biosdevname utility did not parse Vital Product Data (VPD) correctly. As a consequence, names for network interfaces on Vindicator 2 Emulex card were displayed incorrectly when NIC extended partitioning (nPAR-EP) was enabled. VPD parsing has been modified, and Network interface names are now displayed correctly.
BZ#1207557
Prior to this update, the biosdevname utility did not read Vital Product Data (VPD) on NICs with vpd-r:2.0, which resulted in incorrect network interface names when NIC partitioning (NPAR) was enabled on certain NICs. With this update, biosdevname reads VPD data also in cases when NIC has vpdr:2.0, and interface names are now formed as expected if NPAR is enabled.
BZ#1212449
Due to a scheme used for slot numbers derivation, the biosdevname utility did not populate proper names for Virtual Functions (VFs) of on-board NICs. Now, the scheme that enables VFs of on-board NICs can have proper names, too.

Enhancements

BZ#1158564
attribute for a new Mellanox driver and allowing naming of FCoE devices to be ignored.
BZ#1003465, BZ#1084225
This update provides an implementation of 10-GB Ethernet adapters naming scheme from Mellanox. Now, the biosdevname utility produces expected network interface names for Mellanox 10-GB Ethernet adapters that have 2 physical ports on the same PCI device. The /sys/class/net/<iface>/dev_port attribute is designed to distinguish network interfaces.
Users of biosdevname are advised to upgrade to these updated packages, which fix these bugs and add these enhancements.
Red Hat logoGithubRedditYoutubeTwitter

Aprender

Experimente, compre e venda

Comunidades

Sobre a documentação da Red Hat

Ajudamos os usuários da Red Hat a inovar e atingir seus objetivos com nossos produtos e serviços com conteúdo em que podem confiar.

Tornando o open source mais inclusivo

A Red Hat está comprometida em substituir a linguagem problemática em nosso código, documentação e propriedades da web. Para mais detalhes veja oBlog da Red Hat.

Sobre a Red Hat

Fornecemos soluções robustas que facilitam o trabalho das empresas em plataformas e ambientes, desde o data center principal até a borda da rede.

© 2024 Red Hat, Inc.