Este conteúdo não está disponível no idioma selecionado.
2.3. Running SystemTap Scripts
SystemTap scripts are run through the command
stap
. stap
can run SystemTap scripts from the standard input or from a file.
Running
stap
and staprun
requires elevated privileges to the system. However, not all users can be granted root
access just to run SystemTap. In some cases, for instance, a non-privileged user may need to run SystemTap instrumentation on their machine.
To allow ordinary users to run SystemTap without
root
access, add them to both of these user groups:
- stapdev
- Members of this group can use
stap
to run SystemTap scripts, orstaprun
to run SystemTap instrumentation modules.Runningstap
involves compiling SystemTap scripts into kernel modules and loading them into the kernel. This requires elevated privileges to the system, which are granted tostapdev
members. Unfortunately, such privileges also grant effectiveroot
access tostapdev
members. As such, only grantstapdev
group membership to users who can be trusted withroot
access. - stapusr
- Members of this group can only use
staprun
to run SystemTap instrumentation modules. In addition, they can only run those modules from/lib/modules/kernel_version/systemtap/
. Note that this directory must be owned only by theroot
user, and it must only be writable by theroot
user.
Note
In order to run SystemTap scripts, the user must be in both the stapdev and stapusr groups.
Below is a list of commonly used
stap
options:
- -v
- Makes the output of the SystemTap session more verbose. This option (for example,
stap -vvv script.stp
) can be repeated to provide more details on the script's execution. It is particularly useful if errors are encountered when running the script.For more information about common SystemTap script errors, see Chapter 5, Understanding SystemTap Errors. -o filename
- Sends the standard output to filename.
-S size,count
- Limit files to size megabytes and limit the number of files kept around to count. The file names will have a sequence number suffix. This option implements logrotate operations for SystemTap.When used with
-o
, the-S
will limit the size of log files. -x process ID
- Sets the SystemTap handler function
target()
to the specified process ID. For more information abouttarget()
, see SystemTap Functions. -c command
- Sets the SystemTap handler function
target()
to the specified command. The full path to the specified command must be used; for example, instead of specifyingcp
, use/bin/cp
(as instap script -c /bin/cp
). For more information abouttarget()
, see SystemTap Functions. -e 'script'
- Use
script
string rather than a file as input for systemtap translator. -F
- Use SystemTap's Flight recorder mode and make the script a background process. For more information about flight recorder mode, see Section 2.3.1, “SystemTap Flight Recorder Mode”.
stap
can also be instructed to run scripts from the standard input using the -
switch. To illustrate:
Example 2.1. Running Scripts From Standard Input
echo "probe timer.s(1) {exit()}" | stap -
Example 2.1, “Running Scripts From Standard Input” instructs
stap
to run the script passed by echo
to standard input. Any stap
options to be used should be inserted before the -
switch; for instance, to make the example in Example 2.1, “Running Scripts From Standard Input” more verbose, the command would be:
echo "probe timer.s(1) {exit()}" | stap -v -
For more information about
stap
, see man stap
.
To run SystemTap instrumentation (the kernel module built from SystemTap scripts during a cross-instrumentation), use
staprun
instead. For more information about staprun
and cross-instrumentation, see Section 2.2, “Generating Instrumentation for Other Computers”.
Note
The
stap
options -v
and -o
also work for staprun
. For more information about staprun
, see the staprun(1) manual page.
2.3.1. SystemTap Flight Recorder Mode
SystemTap's flight recorder mode allows a SystemTap script to be ran for long periods and just focus on recent output. The flight recorder mode (the
-F
option) limits the amount of output generated. There are two variations of the flight recorder mode: in-memory and file mode. In both cases, the SystemTap script runs as a background process.
2.3.1.1. In-memory Flight Recorder
When flight recorder mode (the
-F
option) is used without a file name, SystemTap uses a buffer in kernel memory to store the output of the script. Next, SystemTap instrumentation module loads and the probes start running, then instrumentation will detatch and be put in the background. When the interesting event occurs, the instrumentation can be reattached and the recent output in the memory buffer and any continuing output can be seen. The following command starts a script using the flight recorder in-memory mode:
stap -F /usr/share/doc/systemtap-version/examples/io/iotime.stp
Once the script starts, a message that provides the command to reconnect to the running script will appear:
Disconnecting from systemtap module. To reconnect, type "staprun -A stap_5dd0073edcb1f13f7565d8c343063e68_19556"
When the interesting event occurs, reattach to the currently running script and output the recent data in the memory buffer, then get the continuing output with the following command:
staprun -A stap_5dd0073edcb1f13f7565d8c343063e68_19556
By default, the kernel buffer is 1MB in size, but it can be increased with the
-s
option specifying the size in megabytes (rounded up to the next power of 2) for the buffer. For example -s2
on the SystemTap command line would specify 2MB for the buffer.
2.3.1.2. File Flight Recorder
The flight recorder mode can also store data to files. The number and size of the files kept is controlled by the
-S
option followed by two numerical arguments separated by a comma. The first argument is the maximum size in megabytes for the each output file. The second argument is the number of recent files to keep. The file name is specified by the -o
option followed by the name. SystemTap adds a number suffix to the file name to indicate the order of the files. The following will start SystemTap in file flight recorder mode with the output going to files named /tmp/pfaults.log.[0-9]+
with each file 1MB or smaller and keeping latest two files:
stap -F -o /tmp/pfaults.log -S 1,2 pfaults.stp
The number printed by the command is the process ID. Sending a
SIGTERM
to the process will shutdown the SystemTap script and stop the data collection. For example, if the previous command listed 7590
as the process ID, the following command would shutdown the SystemTap script:
kill -s SIGTERM 7590
Only the most recent two file generated by the script are kept and the older files are been removed. Thus,
ls -sh /tmp/pfaults.log.*
shows the only two files:
1020K /tmp/pfaults.log.5 44K /tmp/pfaults.log.6
One can look at the highest number file for the latest data, in this case
/tmp/pfaults.log.6
.