Chapter 4. Fencing Controller nodes with STONITH


Fencing is the process of isolating a failed node to protect the cluster and the cluster resources. Without fencing, a failed node might result in data corruption in a cluster. Director uses Pacemaker to provide a highly available cluster of Controller nodes.

Pacemaker uses a process called STONITH to fence failed nodes. STONITH is an acronym for "Shoot the other node in the head". STONITH is disabled by default and requires manual configuration so that Pacemaker can control the power management of each node in the cluster.

Important

Deploying a highly available overcloud without STONITH is not supported. You must configure a STONITH device for each node that is a part of the Pacemaker cluster in a highly available overcloud. For more information on STONITH and Pacemaker, see Fencing in a Red Hat High Availability Cluster and Support Policies for RHEL High Availability Clusters.

If a Controller node fails a health check, the Controller node that acts as the Pacemaker designated coordinator (DC) uses the Pacemaker stonith service to fence the impacted Controller node.

Note

When a Pacemaker cluster node or Pacemaker remote node is fenced a hard kill of the operating system must occur and not a graceful shutdown. For more information, see Testing a fence device in RHEL Configuring and managing high availability clusters.

4.1. Supported fencing agents

When you deploy a high availability environment with fencing, you can choose the fencing agents based on your environment needs. To change the fencing agent, you must configure additional parameters in the fencing.yaml file.

Red Hat OpenStack Platform (RHOSP) supports the following fencing agents:

Intelligent Platform Management Interface (IPMI)
Default fencing mechanism that Red Hat OpenStack Platform (RHOSP) uses to manage fencing.
STONITH Block Device (SBD)

The SBD (Storage-Based Death) daemon integrates with Pacemaker and a watchdog device to arrange for nodes to reliably shut down when fencing is triggered and in cases where traditional fencing mechanisms are not available.

Important
  • You can only configure SBD fencing on controller nodes, because it is not supported on virtual machines or nodes that use the pacemaker_remote service.
  • fence_sbd and sbd poison-pill fencing with block storage devices are not supported.
  • SBD fencing is only supported with compatible watchdog devices. For more information, see Support Policies for RHEL High Availability Clusters - sbd and fence_sbd.
fence_kdump

Use in deployments with the kdump crash recovery service. If you choose this agent, ensure that you have enough disk space to store the dump files.

You can configure this agent in addition to the IPMI, fence_rhevm, or Redfish fencing agents. If you configure multiple fencing agents, ensure that you allocate enough time for the first agent to complete the task before the second agent starts the next task. Implement this fence_kdump STONITH agent as a first level device. For example:

parameter_defaults:
  EnableFencing: true
  FencingConfig:
    devices:
      level1:
      - agent: fence_kdump
        host_mac: aa:bb:cc:dd:ee:ff
      level2:
      - agent: fence_ipmilan
        host_mac: aa:bb:cc:dd:ee:ff
        params:
          <parameter>: <value>
Copy to Clipboard Toggle word wrap
Important
  • RHOSP director supports only the configuration of the fence_kdump STONITH agent, and not the configuration of the full kdump service that the fencing agent depends on. For information about configuring the kdump service, see the article How do I configure fence_kdump in a Red Hat Pacemaker cluster.
  • fence_kdump is not supported if the Pacemaker network traffic interface uses the ovs_bridges or ovs_bonds network device. To enable fence_kdump, you must change the network device to linux_bond or linux_bridge.
Redfish
Use in deployments with servers that support the DMTF Redfish APIs. To specify this agent, change the value of the agent parameter to fence_redfish in the fencing.yaml file. For more information about Redfish, see the DTMF Documentation.
Multi-layered fencing
You can configure multiple fencing agents to support complex fencing use cases. For example, you can configure IPMI fencing together with fence_kdump. The order of the fencing agents determines the order in which Pacemaker triggers each mechanism.

4.2. Deploying fencing on the overcloud

To deploy fencing on the overcloud, first review the state of STONITH and Pacemaker and configure the fencing.yaml file. Then, deploy the overcloud and configure additional parameters. Finally, test that fencing is deployed correctly on the overcloud.

Prerequisites

  • You have chosen the correct fencing agent for your deployment. For the list of supported fencing agents, see Section 4.1, “Supported fencing agents”.
  • You have verified that you can access the nodes.json file that you created when you registered your nodes in director. This file is a required input for the fencing.yaml file that you generate during deployment.
  • This nodes.json file must contain the MAC address of one of the network interfaces (NICs) on the node. For more information, see Registering Nodes for the Overcloud.
  • You have verified that all of the parameters for your fencing agents are correctly specified to ensure that these agents will be successfully created. However, the fencing agents will be created even when their parameters are incorrectly specified. Therefore you must ensure that all the created fencing agents are in the "running" and not the "stopped" state.

Procedure

  1. Log in to each Controller node as the tripleo-admin user.
  2. Verify that the cluster is running:

    $ sudo pcs status
    Copy to Clipboard Toggle word wrap

    Example output:

    Cluster name: openstackHA
    Last updated: Wed Jun 24 12:40:27 2015
    Last change: Wed Jun 24 11:36:18 2015
    Stack: corosync
    Current DC: lb-c1a2 (2) - partition with quorum
    Version: 1.1.12-a14efad
    3 Nodes configured
    141 Resources configured
    Copy to Clipboard Toggle word wrap
  3. Verify that STONITH is disabled:

    $ sudo pcs property show
    Copy to Clipboard Toggle word wrap

    Example output:

    Cluster Properties:
    cluster-infrastructure: corosync
    cluster-name: openstackHA
    dc-version: 1.1.12-a14efad
    have-watchdog: false
    stonith-enabled: false
    Copy to Clipboard Toggle word wrap
  4. Depending on the fencing agent that you want to use, choose one of the following options:

    • If you use the IPMI or RHV fencing agent, generate the fencing.yaml environment file:

      (undercloud) $ openstack overcloud generate fencing --output fencing.yaml nodes.json
      Copy to Clipboard Toggle word wrap
      Note

      This command converts ilo and drac power management details to IPMI equivalents.

    • If you use a different fencing agent, such as STONITH Block Device (SBD), fence_kdump, or Redfish, or if you use pre-provisioned nodes, create the fencing.yaml file manually.
  5. SBD fencing only: Add the following parameter to the fencing.yaml file:

    parameter_defaults:
      ExtraConfig:
        pacemaker::corosync::enable_sbd: true
    Copy to Clipboard Toggle word wrap
    Note

    This step is applicable to initial overcloud deployments only. For more information about how to enable SBD fencing on an existing overcloud, see Enabling sbd fencing in RHEL 7 and 8.

  6. Multi-layered fencing only: Add the level-specific parameters to the generated fencing.yaml file:

    parameter_defaults:
      EnableFencing: true
      FencingConfig:
        devices:
          level1:
          - agent: [VALUE]
            host_mac: "aa:bb:cc:dd:ee:ff"
            params:
              <parameter>: <value>
          level2:
          - agent: fence_agent2
            host_mac: "aa:bb:cc:dd:ee:ff"
            params:
              <parameter>: <value>
    Copy to Clipboard Toggle word wrap

    Replace <parameter> and <value> with the actual parameters and values that the fencing agent requires.

  7. Run the overcloud deploy command and include the fencing.yaml file and any other environment files that are relevant for your deployment:

    openstack overcloud deploy --templates \
    -e /usr/share/openstack-tripleo-heat-templates/environments/network-isolation.yaml \
    -e ~/templates/network-environment.yaml \
    -e ~/templates/storage-environment.yaml --ntp-server pool.ntp.org --neutron-network-type vxlan --neutron-tunnel-types vxlan \
    -e fencing.yaml
    Copy to Clipboard Toggle word wrap
  8. SBD fencing only: Set the watchdog timer device interval and check that the interval is set correctly.

    # pcs property set stonith-watchdog-timeout=<interval>
    # pcs property show
    Copy to Clipboard Toggle word wrap
  9. Ensure that all of the created fencing agents are in the "running" and not the "stopped" state. Fencing agents in the "stopped" state have been incorrectly configured.

Verification

  1. Log in to the overcloud as the tripleo-admin user and ensure that Pacemaker is configured as the resource manager:

    $ source stackrc
    $ metalsmith list | grep controller
    $ ssh tripleo-admin@<controller-x_ip>
    $ sudo pcs status | grep fence
    stonith-overcloud-controller-x (stonith:fence_ipmilan): Started overcloud-controller-y
    Copy to Clipboard Toggle word wrap

    In this example, Pacemaker is configured to use a STONITH resource for each of the Controller nodes that are specified in the fencing.yaml file.

    Note

    You must not configure the fence-resource process on the same node that it controls.

  2. Check the fencing resource attributes. The STONITH attribute values must match the values in the fencing.yaml file:

    $ sudo pcs stonith show <stonith-resource-controller-x>
    Copy to Clipboard Toggle word wrap

4.3. Testing fencing on the overcloud

To test that fencing works correctly, trigger fencing by closing all ports on a Controller node and restarting the server.

Important

This procedure deliberately drops all connections to the Controller node, which causes the node to restart.

Prerequisites

Procedure

  1. Log in to a Controller node as the stack user and source the credentials file:

    $ source stackrc
    $ metalsmith list | grep controller
    $ ssh tripleo-admin@<controller-x_ip>
    Copy to Clipboard Toggle word wrap
  2. Change to the root user and close all connections to the Controller node:

    $ sudo -i
    iptables -A INPUT -m state --state RELATED,ESTABLISHED -j ACCEPT &&
    iptables -A INPUT -p tcp -m state --state NEW -m tcp --dport 22 -j ACCEPT &&
    iptables -A INPUT -p tcp -m state --state NEW -m tcp --dport 5016 -j ACCEPT &&
    iptables -A INPUT -p udp -m state --state NEW -m udp --dport 5016 -j ACCEPT &&
    iptables -A INPUT ! -i lo -j REJECT --reject-with icmp-host-prohibited &&
    iptables -A OUTPUT -p tcp --sport 22 -j ACCEPT &&
    iptables -A OUTPUT -p tcp --sport 5016 -j ACCEPT &&
    iptables -A OUTPUT -p udp --sport 5016 -j ACCEPT &&
    iptables -A OUTPUT ! -o lo -j REJECT --reject-with icmp-host-prohibited
    Copy to Clipboard Toggle word wrap
  3. From a different Controller node, locate the fencing event in the Pacemaker log file:

    $ ssh tripleo-admin@<controller-x_ip>
    $ less /var/log/cluster/corosync.log
    (less): /fenc*
    Copy to Clipboard Toggle word wrap

    If the STONITH service performed the fencing action on the Controller, the log file shows a fencing event.

  4. Wait a few minutes and then verify that the restarted Controller node is running in the cluster again by running the pcs status command. If you can see the Controller node that you restarted in the output, fencing functions correctly.

4.4. Viewing STONITH device information

To see how STONITH configures your fencing devices, run the pcs stonith status --full command from the overcloud.

Prerequisites

Procedure

  • Show the list of Controller nodes and the status of their STONITH devices:

    $ sudo pcs stonith status --full
     Resource: my-ipmilan-for-controller-0 (class=stonith type=fence_ipmilan)
      Attributes: pcmk_host_list=overcloud-controller-0 ipaddr=10.100.0.51 login=admin passwd=abc lanplus=1 cipher=3
      Operations: monitor interval=60s (my-ipmilan-for-controller-0-monitor-interval-60s)
     Resource: my-ipmilan-for-controller-1 (class=stonith type=fence_ipmilan)
      Attributes: pcmk_host_list=overcloud-controller-1 ipaddr=10.100.0.52 login=admin passwd=abc lanplus=1 cipher=3
      Operations: monitor interval=60s (my-ipmilan-for-controller-1-monitor-interval-60s)
     Resource: my-ipmilan-for-controller-2 (class=stonith type=fence_ipmilan)
      Attributes: pcmk_host_list=overcloud-controller-2 ipaddr=10.100.0.53 login=admin passwd=abc lanplus=1 cipher=3
      Operations: monitor interval=60s (my-ipmilan-for-controller-2-monitor-interval-60s)
    Copy to Clipboard Toggle word wrap

    This output shows the following information for each resource:

    • IPMI power management service that the fencing device uses to turn the machines on and off as needed, such as fence_ipmilan.
    • IP address of the IPMI interface, such as 10.100.0.51.
    • User name to log in with, such as admin.
    • Password to use to log in to the node, such as abc.
    • Interval in seconds at which each host is monitored, such as 60s.

4.5. Fencing parameters

When you deploy fencing on the overcloud, you generate the fencing.yaml file with the required parameters to configure fencing.

The following example shows the structure of the fencing.yaml environment file:

parameter_defaults:
  EnableFencing: true
  FencingConfig:
    devices:
    - agent: fence_ipmilan
      host_mac: "11:11:11:11:11:11"
      params:
        ipaddr: 10.0.0.101
        lanplus: true
        login: admin
        passwd: InsertComplexPasswordHere
        privlvl: administrator
Copy to Clipboard Toggle word wrap

This file contains the following parameters:

EnableFencing
Enables the fencing functionality for Pacemaker-managed nodes.
FencingConfig

Lists the fencing devices and the parameters for each device:

  • agent: Fencing agent name.
  • host_mac: The mac address in lowercase of the provisioning interface or any other network interface on the server. You can use this as a unique identifier for the fencing device.

    Important

    Do not use the MAC address of the IPMI interface.

  • params: List of fencing device parameters.
Fencing device parameters

Lists the fencing device parameters. This example shows the parameters for the IPMI fencing agent:

  • auth: IPMI authentication type (md5, password, or none).
  • ipaddr: IPMI IP address.
  • ipport: IPMI port.
  • login: Username for the IPMI device.
  • passwd: Password for the IPMI device.
  • lanplus: Use lanplus to improve security of connection.
  • privlvl: Privilege level on IPMI device
  • pcmk_host_list: List of Pacemaker hosts.
Voltar ao topo
Red Hat logoGithubredditYoutubeTwitter

Aprender

Experimente, compre e venda

Comunidades

Sobre a documentação da Red Hat

Ajudamos os usuários da Red Hat a inovar e atingir seus objetivos com nossos produtos e serviços com conteúdo em que podem confiar. Explore nossas atualizações recentes.

Tornando o open source mais inclusivo

A Red Hat está comprometida em substituir a linguagem problemática em nosso código, documentação e propriedades da web. Para mais detalhes veja o Blog da Red Hat.

Sobre a Red Hat

Fornecemos soluções robustas que facilitam o trabalho das empresas em plataformas e ambientes, desde o data center principal até a borda da rede.

Theme

© 2025 Red Hat