此内容没有您所选择的语言版本。
Appendix B. Fence Device Parameters
This appendix provides tables with parameter descriptions of fence devices.
Note
The
parameter for a fence device specifies an arbitrary name for the device that will be used by Red Hat Cluster Suite. This is not the same as the DNS name for the device.
Note
Certain fence devices have an optional
parameter. The parameter allows specifying that a fence-device password is supplied from a script rather than from the parameter. Using the parameter supersedes the parameter, allowing passwords to not be visible in the cluster configuration file (/etc/cluster/cluster.conf
).
Field | Description |
---|---|
Name | A name for the APC device connected to the cluster. |
IP Address | The IP address assigned to the device. |
Login | The login name used to access the device. |
Password | The password used to authenticate the connection to the device. |
Password Script (optional) | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Power wait | Number of seconds to wait after issuing a power off or power on command. |
Port | The port. |
Switch (optional) | The switch number for the APC switch that connects to the node when you have multiple daisy-chained switches. |
Use SSH | (Red Hat Enterprise Linux 5.4 and later) Indicates that system will use SSH to access the device. |
fence_apc | The fence agent for APC. |
Field | Description |
---|---|
Name | A name for the APC device connected to the cluster into which the fence daemon logs via the SNMP protocol. |
IP Address | The IP address or hostname assigned to the device. |
UDP/TCP Port | The UDP/TCP port to use for connection with the device; the default value is 161. |
Login | The login name used to access the device. |
Password | The password used to authenticate the connection to the device. |
Password Script (optional) | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
SNMP version | The SNMP version to use (1, 2c, 3); the default value is 1. |
SNMP community | The SNMP community string; the default value is private . |
SNMP security level | The SNMP security level (noAuthNoPriv, authNoPriv, authPriv). |
SNMP authentication protocol | The SNMP authentication protocol (MD5, SHA). |
SNMP privacy protocol | The SNMP privacy protocol (DES, AES). |
SNMP privacy protocol password | The SNMP privacy protocol password. |
SNMP privacy protocol script | The script that supplies a password for SNMP privacy protocol. Using this supersedes the | parameter.
Power wait | Number of seconds to wait after issuing a power off or power on command. |
Port | The port. |
fence_apc_snmp | The fence agent for APC that logs into the SNP device via the SNMP protocol. |
Field | Description |
---|---|
Name | A name for the Brocade device connected to the cluster. |
IP Address | The IP address assigned to the device. |
Login | The login name used to access the device. |
Password | The password used to authenticate the connection to the device. |
Password Script (optional) | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Port | The switch outlet number. |
fence_brocade | The fence agent for Brocade FC switches. |
Field | Description |
---|---|
Name | A name for the Bull PAP system connected to the cluster. |
IP Address | The IP address assigned to the PAP console. |
Login | The login name used to access the PAP console. |
Password | The password used to authenticate the connection to the PAP console. |
Password Script (optional) | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Domain | Domain of the Bull PAP system to power cycle. |
fence_bullpap | The fence agent for Bull’s NovaScale machines controlled by PAP management consoles. |
Field | Description |
---|---|
Name | A name for the Cisco MDS 9000 series device with SNMP enabled. |
IP address or hostname | The IP address or hostname assigned to the device. |
UDP/TCP port (optional) | The UDP/TCP port to use for connection with the device; the default value is 161. |
Login | The login name used to access the device. |
Password | The password used to authenticate the connection to the device. |
Password Script (optional) | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
SNMP version | The SNMP version to use (1, 2c, 3). |
SNMP community | The SNMP community string. |
SNMP security level | The SNMP security level (noAuthNoPriv, authNoPriv, authPriv). |
SNMP authentication protocol | The SNMP authentication protocol (MD5, SHA). |
SNMP privacy protocol | The SNMP privacy protocol (DES, AES). |
SNMP privacy protocol password | The SNMP privacy protocol password. |
SNMP privacy protocol script | The script that supplies a password for SNMP privacy protocol. Using this supersedes the | parameter.
Power wait | Number of seconds to wait after issuing a power off or power on command. |
Port | The port. |
fence_cisco_mds | The fence agent for Cisco MDS. |
Field | Description |
---|---|
Name | A name for the Cisco UCS device. |
IP Address | The IP address or hostname assigned to the device. |
IP port (optional) | The TCP port to use to connect to the device. |
Login | The login name used to access the device. |
Password | The password used to authenticate the connection to the device. |
Password Script (optional) | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Use SSL connections | Use SSL connections to communicate with the device. |
Sub-organization | Additional path needed to access suborganization. |
Power wait | Number of seconds to wait after issuing a power off or power on command. |
Port | Name of virtual machine. |
fence_cisco_ucs | The fence agent for Cisco UCS. |
Field | Description |
---|---|
Name | The name assigned to the DRAC. |
IP Address | The IP address assigned to the DRAC. |
Login | The login name used to access the DRAC. |
Password | The password used to authenticate the connection to the DRAC. |
Module Name | (optional) The module name for the DRAC when you have multiple DRAC modules. |
Password Script (optional) | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Use SSH (DRAC5 only) | (Red Hat Enterprise Linux 5.4 and later) Indicates that system will use SSH to access the device. |
Power wait | Number of seconds to wait after issuing a power off or power on command. |
fence_drac | The fence agent for Dell Remote Access Card (DRAC). |
Field | Description |
---|---|
Name | A name for the BladeFrame device connected to the cluster. |
CServer | The hostname (and optionally the username in the form of username@hostname ) assigned to the device. Refer to the fence_egenera(8) man page for more information. |
ESH Path (optional) | The path to the esh command on the cserver (default is /opt/pan- mgr/bin/esh) |
lpan | The logical process area network (LPAN) of the device. |
pserver | The processing blade (pserver) name of the device. |
fence_egenera | The fence agent for the Egenera BladeFrame. |
Field | Description |
---|---|
Name | A name for the RSB to use as a fence device. |
Hostname | The hostname assigned to the device. |
Login | The login name used to access the device. |
Password | The password used to authenticate the connection to the device. |
Password Script (optional) | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
fence_rsb | The fence agent for Fujitsu-Siemens RSB. |
Field | Description |
---|---|
Name | A name for the GNBD device used to fence the cluster. Note that the GFS server must be accessed via GNBD for cluster node fencing support. |
Servers | The hostname of the server to fence the client from, in either IP address or hostname form. For multiple hostnames, separate each hostname with a whitespace. |
IP Address | The cluster name of the node to be fenced. Refer to the fence_gnbd (8) man page for more information. |
fence_gnbd | The fence agent for GNBD-based GFS clusters. |
Field | Description |
---|---|
Name | A name for the server with HP iLO support. |
Hostname | The hostname assigned to the device. |
Login | The login name used to access the device. |
Password | The password used to authenticate the connection to the device. |
Password Script (optional) | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Use SSL connections | Use SSL connections to communicate with the device. |
Power wait | Number of seconds to wait after issuing a power off or power on command. |
fence_ilo | The fence agent for HP servers with the Integrated Light Out (iLO) PCI card. |
Field | Description |
---|---|
Name | A name for the server with HP iLO support. |
Hostname | The hostname assigned to the device. |
IP port (optional) | TCP port to use for connection with the device. |
Login | The login name used to access the device. |
Password | The password used to authenticate the connection to the device. |
Password Script (optional) | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Use SSH | (Red Hat Enterprise Linux 5.4 and later) Indicates that system will use SSH to access the device. |
Path to SSH identity file | The identity file for SSH. |
Force command prompt | The command prompt to use. The default value is ’MP>’, ’hpiLO->’. |
Power wait | Number of seconds to wait after issuing a power off or power on command. |
fence_ilo_mp | The fence agent for HP iLO MP devices. |
Field | Description |
---|---|
Name | A name for the IBM BladeCenter device connected to the cluster. |
IP Address | The IP address assigned to the device. |
Login | The login name used to access the device. |
Password | The password used to authenticate the connection to the device. |
Password Script (optional) | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Power wait | Number of seconds to wait after issuing a power off or power on command. |
Blade | The blade of the device. |
Use SSH | (Red Hat Enterprise Linux 5.4 and later) Indicates that system will use SSH to access the device. |
fence_bladecenter | The fence agent for IBM BladeCenter. |
Field | Description |
---|---|
Name | A name for the IBM iPDU device connected to the cluster into which the fence daemon logs via the SNMP protocol. |
IP Address | The IP address or hostname assigned to the device. |
UDP/TCP Port | The UDP/TCP port to use for connection with the device; the default value is 161. |
Login | The login name used to access the device. |
Password | The password used to authenticate the connection to the device. |
Password Script (optional) | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
SNMP version | The SNMP version to use (1, 2c, 3); the default value is 1. |
SNMP community | The SNMP community string; the default value is private . |
SNMP security level | The SNMP security level (noAuthNoPriv, authNoPriv, authPriv). |
SNMP authentication protocol | The SNMP authentication protocol (MD5, SHA). |
SNMP privacy protocol | The SNMP privacy protocol (DES, AES). |
SNMP privacy protocol password | The SNMP privacy protocol password. |
SNMP privacy protocol script | The script that supplies a password for SNMP privacy protocol. Using this supersedes the | parameter.
Power wait | Number of seconds to wait after issuing a power off or power on command. |
Port | The port. |
fence_ipdu | The fence agent for iPDU over SNMP. |
Field | Description |
---|---|
Name | A name for the RSA device connected to the cluster. |
Hostname | The hostname assigned to the device. |
Login | The login name used to access the device. |
Password | The password used to authenticate the connection to the device. |
Password Script (optional) | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Power wait | Number of seconds to wait after issuing a power off or power on command. |
fence_rsa | The fence agent for the IBM RSA II management interface. |
Field | Description |
---|---|
Name | A name for the IF MIB device connected to the cluster. |
IP address or hostname | The IP address or hostname assigned to the device. |
UDP/TCP port (optional) | The UDP/TCP port to use for connection with the device; the default value is 161. |
Login | The login name used to access the device. |
Password | The password used to authenticate the connection to the device. |
Password Script (optional) | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
SNMP version | The SNMP version to use (1, 2c, 3); the default value is 1. |
SNMP community | The SNMP community string. |
SNMP security level | The SNMP security level (noAuthNoPriv, authNoPriv, authPriv). |
SNMP authentication protocol | The SNMP authentication protocol (MD5, SHA). |
SNMP privacy protocol | The SNMP privacy protocol (DES, AES). |
SNMP privacy protocol password | The SNMP privacy protocol password. |
SNMP privacy protocol script | The script that supplies a password for SNMP privacy protocol. Using this supersedes the | parameter.
Power wait | Number of seconds to wait after issuing a power off or power on command. |
Port | Physical plug number or name of virtual machine. |
fence_ifmib | The fence agent for IF-MIB devices. |
Field | Description |
---|---|
Name | A name for the IPMI LAN device connected to the cluster. |
IP Address | The IP address assigned to the IPMI port. |
Login | The login name of a user capable of issuing power on/off commands to the given IPMI port. |
Password | The password used to authenticate the connection to the IPMI port. |
Password Script (optional) | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Authentication Type | none , password , md2 , or md5 . |
Privilege Level | The privilege level on the IPMI device. |
Use Lanplus | True or 1 . If blank, then value is False . |
fence_ipmilan | The fence agent for machines controlled by IPMI. |
Field | Description |
---|---|
Name | A name to assign the Manual fencing agent. Refer to the fence_manual (8) man page for more information. |
Warning
Manual fencing is not supported for production environments.
Field | Description |
---|---|
Name | A name for the McData device connected to the cluster. |
IP Address | The IP address assigned to the device. |
Login | The login name used to access the device. |
Password | The password used to authenticate the connection to the device. |
Password Script (optional) | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Port | The switch outlet number. |
fence_mcdata | The fence agent for McData FC switches. |
Field | Description |
---|---|
Name | A name for the SANBox2 device connected to the cluster. |
IP Address | The IP address assigned to the device. |
Login | The login name used to access the device. |
Password | The password used to authenticate the connection to the device. |
Password Script (optional) | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Power wait | Number of seconds to wait after issuing a power off or power on command. |
Port | The switch outlet number. |
fence_sanbox2 | The fence agent for QLogic SANBox2 FC switches. |
Field | Description |
---|---|
Name | Name of the RHEV-M REST API fencing device. |
IP Address | The IP address or hostname assigned to the device. |
IP port (optional) | The TCP port to use for connection with the device. |
Login | The login name used to access the device. |
Password | The password used to authenticate the connection to the device. |
Password Script (optional) | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Use SSL connections | Use SSL connections to communicate with the device. |
Power wait | Number of seconds to wait after issuing a power off or power on command. |
Port | Physical plug number or name of virtual machine. |
fence_rhevm | The fence agent for RHEV-M REST API. |
Field | Description |
---|---|
Name | A name for the WTI RPS-10 power switch connected to the cluster. |
Device Name | The device name of the device the switch is connected to on the controlling host (for example, /dev/ttys2 ). |
Port | The switch outlet number. |
fence_wti | The fence agent for the WTI Network Power Switch. |
Field | Description |
---|---|
Name | A name for the SCSI fence device. |
Node name | Name of the node to be fenced. Refer to the fence_scsi (8) man page for more information. |
fence_scsi | The fence agent for SCSI persistent reservations. |
Note
Use of SCSI persistent reservations as a fence method is supported with the following limitations:
- As of Red Hat Enterprise Linux 5.5 and fully-updated releases of Red Hat Enterprise Linux 5.4, SCSI fencing can be used in a 2-node cluster; previous releases did not support this feature.
- When using SCSI fencing, all nodes in the cluster must register with the same devices so that each node can remove another node's registration key from all the devices it is registered with.
- Devices used for the cluster volumes should be a complete LUN, not partitions. SCSI persistent reservations work on an entire LUN, meaning that access is controlled to each LUN, not individual partitions.
- As of Red Hat Enterprise Linux 5.5 and fully-updated releases of Red Hat Enterprise Linux 5.4, SCSI fencing can be used in conjunction with qdisk; previous releases did not support this feature. You cannot use
fence_scsi
on the LUN whereqdiskd
resides; it must be a raw LUN or raw partition of a LUN.
Field | Description |
---|---|
Name | Name of the virtual machine fencing device. |
Domain | Unique domain name of the guest to be fenced. |
Field | Description |
---|---|
Name | Name of the virtual machine fencing device. |
Hostname | The IP address or hostname assigned to the device. |
IP port (optional) | The TCP port to use for connection with the device. |
Login | The login name used to access the device. |
Password | The password used to authenticate the connection to the device. |
Password Script (optional) | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Use SSL connections | Use SSL connections to communicate with the device. |
Power wait | Number of seconds to wait after issuing a power off or power on command. |
Virtual machine name | Name of virtual machine in inventory path format (e.g., /datacenter/vm/Discovered_virtual_machine/myMachine). |
Virtual machine UUID | The UUID of the virtual machine to fence. |
fence_vmware_soap | The fence agent for VMWare over SOAP API. |
Field | Description |
---|---|
Name | A name for the Vixel switch connected to the cluster. |
IP Address | The IP address assigned to the device. |
Password | The password used to authenticate the connection to the device. |
Password Script (optional) | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Port | The switch outlet number. |
fence_vixel | The fence agent for Vixel switches. |
Field | Description |
---|---|
Name | A name for the WTI power switch connected to the cluster. |
IP Address | The IP address assigned to the device. |
Password | The password used to authenticate the connection to the device. |
Password Script (optional) | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Power wait | Number of seconds to wait after issuing a power off or power on command. |
Port | The switch outlet number. |
Use SSH | (Red Hat Enterprise Linux 5.4 and later) Indicates that system will use SSH to access the device. |
fence_wti | The fence agent for the WTI network power switch. |