4.4. Cisco MDS


Table 4.5, “Cisco MDS” lists the fence device parameters used by fence_cisco_mds, the fence agent for Cisco MDS.
Table 4.5. Cisco MDS
luci Field cluster.conf Attribute Description
Name name A name for the Cisco MDS 9000 series device with SNMP enabled.
IP Address or Hostname ipaddr The IP address or host name assigned to the device.
UDP/TCP port (optional) udpport The UDP/TCP port to use for connection with the device; the default value is 161.
Login login The login name used to access the device.
Password passwd The password used to authenticate the connection to the device.
Password Script (optional) passwd_script The script that supplies a password for access to the fence device. Using this supersedes the Password parameter.
SNMP Version snmp_version The SNMP version to use (1, 2c, 3).
SNMP Community community The SNMP community string.
SNMP Security Level snmp_sec_level The SNMP security level (noAuthNoPriv, authNoPriv, authPriv).
SNMP Authentication Protocol snmp_auth_prot The SNMP authentication protocol (MD5, SHA).
SNMP Privacy Protocol snmp_priv_prot The SNMP privacy protocol (DES, AES).
SNMP Privacy Protocol Password snmp_priv_passwd The SNMP privacy protocol password.
SNMP Privacy Protocol Script snmp_priv_passwd_script The script that supplies a password for SNMP privacy protocol. Using this supersedes the SNMP privacy protocol password parameter.
Power Wait (seconds) power_wait Number of seconds to wait after issuing a power off or power on command.
Power Timeout (seconds) power_timeout Number of seconds to continue testing for a status change after issuing a power off or power on command. The default value is 20.
Shell Timeout (seconds) shell_timeout Number of seconds to wait for a command prompt after issuing a command. The default value is 3.
Login Timeout (seconds) login_timeout Number of seconds to wait for a command prompt after login. The default value is 5.
Times to Retry Power On Operation retry_on Number of attempts to retry a power on operation. The default value is 1.
Port (Outlet) Number port The port.
Delay (optional) delay The number of seconds to wait before fencing is started. The default value is 0.
Figure 4.4, “Cisco MDS” shows the configuration screen for adding an Cisco MDS fence device.
Cisco MDS

Figure 4.4. Cisco MDS

The following command creates a fence device instance for a Cisco MDS device:
ccs -f cluster.conf --addfencedev mds agent=fence_cisco_mds ipaddr=192.168.0.1 name=ciscomdstest1 login=root \
 passwd=password123 power_wait=60 snmp_priv_passwd=password123 udpport=161
The following is the cluster.conf entry for the fence_cisco_mds device:

 <fencedevices>
   <fencedevice agent="fence_cisco_mds" community="private" ipaddr="192.168.0.1" login="root" \
     name="ciscomdstest1" passwd="password123" power_wait="60" snmp_priv_passwd="password123" \
     udpport="161"/>
 </fencedevices>
Red Hat logoGithubRedditYoutubeTwitter

Learn

Try, buy, & sell

Communities

About Red Hat Documentation

We help Red Hat users innovate and achieve their goals with our products and services with content they can trust.

Making open source more inclusive

Red Hat is committed to replacing problematic language in our code, documentation, and web properties. For more details, see the Red Hat Blog.

About Red Hat

We deliver hardened solutions that make it easier for enterprises to work across platforms and environments, from the core datacenter to the network edge.

© 2024 Red Hat, Inc.