Ce contenu n'est pas disponible dans la langue sélectionnée.
Chapter 25. Clustering
Pacemaker correctly implements fencing and unfencing for Pacemaker remote nodes
Previously, Pacemaker did not implement unfencing for Pacemaker remote nodes. As a consequence, Pacemaker remote nodes remained fenced even if a fence device required unfencing. With this update, Pacemaker correctly implements both fencing and unfencing for Pacemaker remote nodes, and the described problem no longer occurs. (BZ#1394418)
Pacemaker now probes guest nodes
Important update for users of guest nodes.
Pacemaker now probes guest nodes, which are Pacemaker remote nodes created using the
remote-node
parameter of a resource such as VirtualDomain
. If users were previously relying on the fact that probes were not done, the probes may fail, potentially causing fencing of the guest node. If a guest node cannot run a probe of a resource (for example, if the software is not even installed on the guest), then the location constraint banning the resource from the guest node should have the resource-discovery
option set to never
, the same as would be required with a cluster node or remote node in the same situation. (BZ#1489728)
The pcs resource cleanup
command no longer generates unnecessary cluster load
The
pcs resource cleanup
command cleans the records of failed resource operations that have been resolved. Previously, the command probed all resources on all nodes, generating an unnecessary load on cluster operation. With this fix, the command probes only the resources for which a resource operation failed. The previous functionality of the pcs resource cleanup
command has been replaced by the new pcs resource refresh
command, which probes all resources on all nodes. For information on cluster resource cleanup, see https://access.redhat.com/documentation/en-us/red_hat_enterprise_linux/7/html/high_availability_add-on_reference/s1-resource_cleanup-haar. (BZ#1508351)
Warning generated when user specifies action
attribute for stonith device
Previously, it was possible for a user to set an action attribute for a stonith device, even though this option is deprecated and is not recommended as it can cause unexpected fencing. The following fixes have been implemented:
- When a user tries to set an
action
option of a stonith device with the CLI, this generates a warning message along with the instructions to use the--force
flag to set this attribute. - The
pcsd
Web UI now displays a warning message next toaction
option field. - The output of the
pcs status
command displays a warning when a stonith device has theaction
option set. (BZ#1421702)
It is now possible to enable stonith agent debugging without specifying the --force
flag
Previously, attempting to enable debugging of a stonith agent by setting the
debug
or verbose
parameters required that the user specify the --force
flag. With this fix, using the --force
flag is no longer necessary. (BZ#1432283)
The fence_ilo3
resource agent no longer has a default value of cycle
for the action
parameter
Previously, the
fence_ilo3
resource agent had a default value of cycle
for the action
parameter. This value is unsupported, as it may cause data corruption. The default value for this parameter is now onoff
. Additionally, a warning is now displayed in the output of the pcs status
command and the web UI if a stonith device has its method
option set to cycle
. (BZ#1519370, BZ#1523378)
Pacemaker no longer starts up when sbd
is enabled but not started successfully by systemd
Previously, if
sbd
did not start properly, systemd
would still start Pacemaker. This would lead to sbd
poison pill triggered reboots not being performed without this being detected by fence_sbd
and, in the case of quorum-based watchdog fencing, the nodes losing quorum would not self-fence either. With this fix, if sbd
does not come up properly Pacemaker is not started. This should prevent all sources of data curruption due to sbd
not coming up. (BZ#1525981)
A fenced node in an ‘sbd’ setup now shuts down reliably
Previously, when a node received an ‘off’ via the poison pill mechanism used by ‘sbd’ on a shared disk, the node would be likely to reboot instead of powering off. With this fix, receiving an ‘off’ will power off the node. Receiving a ‘reset’ will reboot the node. If the node is not able to perform the software-driven reboot or power off properly, the watchdog is going to trigger and the action performed is what the watchdog device is configured to. A fenced node in an ‘sbd’ setup now shuts down reliably if the watchdog device is configured to power off the node, and fencing is requesting ‘off’ via the poison pill mechanism on a shared disk. (BZ#1468580)
IPaddr2
resource agent now finds NIC for IPv6 addresses with 128 netmask
Previously, the
IPaddr2
resource agent failed to find the NIC for IPv6 addresses with 128 netmask. This fix corrects that issue. (BZ#1445628)
portblock
agent no longer yields excessive unnecessary messages
Previously, the
portblock
agent would flood the /var/log/messages
file with monitoring messages that provided no useful information. With this fix, the /var/log/messages
file contains more limited logging output from the portblock
agent. (BZ#1457382)
/var/run/resource-agents
directory now persists across reboots
Previously, the
/var/run/resource-agents
directory, created at installation of the resource-agents
package, was not persistent across reboots. With this fix, the directory is now present after a reboot. (BZ#1462802)