4.3. Power Management


The Red Hat Enterprise Virtualization Manager is capable of rebooting hosts that have entered a non-operational or non-responsive state, as well as preparing to power off under-utilized hosts to save power. This functionality depends on a properly configured power management device. The Red Hat Enterprise Virtualization environment supports the following power management devices:
  • American Power Conversion (apc).
  • Bladecenter.
  • Cisco Unified Computing System (cisco_ucs).
  • Dell Remote Access Card 5 (drac5).
  • Dell Remote Access Card 7 (drac7).
  • Electronic Power Switch (eps).
  • HP BladeSystem (hpblade).
  • Integrated Lights Out (ilo, ilo2, ilo3, ilo4).
  • Intelligent Platform Management Interface (ipmilan).
  • Remote Supervisor Adapter (rsa).
  • rsb.
  • Western Telematic, Inc (wti).

Note

APC 5.x power management devices are not supported by the apc fence agent. Use the apc_snmp fence agent instead.
In order to communicate with the listed power management devices, the Red Hat Enterprise Virtualization Manager makes use of fence agents. The Red Hat Enterprise Virtualization Manager allows administrators to configure a fence agent for the power management device in their environment with parameters the device will accept and respond to. Basic configuration options can be configured using the graphical user interface. Special configuration options can also be entered, and are passed un-parsed to the fence device. Special configuration options are specific to a given fence device, while basic configuration options are for functionalities provided by all supported power management devices. The basic functionalities provided by all power management devices are:
  • Status: check the status of the host.
  • Start: power on the host.
  • Stop: power down the host.
  • Restart: restart the host. Actually implemented as stop, wait, status, start, wait, status.
Best practice is to test the power management configuration once when initially configuring it, and occasionally after that to ensure continued functionality.
Resilience is provided by properly configured power management devices in all of the hosts in an environment. Fencing agents allow the Red Hat Enterprise Virtualization Manager to communicate with host power management devices to bypass the operating system on a problem host, and isolate the host from the rest of its environment by rebooting it. The Manager can then reassign the SPM role, if it was held by the problem host, and safely restart any highly available virtual machines on other hosts.
맨 위로 이동
Red Hat logoGithubredditYoutubeTwitter

자세한 정보

평가판, 구매 및 판매

커뮤니티

Red Hat 문서 정보

Red Hat을 사용하는 고객은 신뢰할 수 있는 콘텐츠가 포함된 제품과 서비스를 통해 혁신하고 목표를 달성할 수 있습니다. 최신 업데이트를 확인하세요.

보다 포괄적 수용을 위한 오픈 소스 용어 교체

Red Hat은 코드, 문서, 웹 속성에서 문제가 있는 언어를 교체하기 위해 최선을 다하고 있습니다. 자세한 내용은 다음을 참조하세요.Red Hat 블로그.

Red Hat 소개

Red Hat은 기업이 핵심 데이터 센터에서 네트워크 에지에 이르기까지 플랫폼과 환경 전반에서 더 쉽게 작업할 수 있도록 강화된 솔루션을 제공합니다.

Theme

© 2025 Red Hat