此内容没有您所选择的语言版本。
Appendix B. Fence Device Parameters
This appendix provides tables with parameter descriptions of fence devices.
Note
Certain fence devices have an optional
parameter. The parameter allows specifying that a fence-device password is supplied from a script rather than from the parameter. Using the parameter supersedes the parameter, allowing passwords to not be visible in the cluster configuration file (/etc/cluster/cluster.conf
).
Field | Description |
---|---|
Name | A name for the APC device connected to the cluster. |
IP Address | The IP address assigned to the device. |
Login | The login name used to access the device. |
Password | The password used to authenticate the connection to the device. |
Password Script (optional) | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Port | The switch outlet number. |
Switch (optional) | The switch number for the APC switch that connects to the node when you have multiple daisy-chained switches. |
Use SSH | (Rhel 4.8 and later) Indicates that system will use SSH to access the device. |
Field | Description |
---|---|
Name | A name for the Brocade device connected to the cluster. |
IP Address | The IP address assigned to the device. |
Login | The login name used to access the device. |
Password | The password used to authenticate the connection to the device. |
Password Script (optional) | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Port | The switch outlet number. |
Field | Description |
---|---|
Name | A name for the Bull PAP system connected to the cluster. |
IP Address | The IP address assigned to the PAP console. |
Login | The login name used to access the PAP console. |
Password | The password used to authenticate the connection to the PAP console. |
Password Script (optional) | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Domain | Domain of the Bull PAP system to power cycle. |
Field | Description |
---|---|
Name | The name assigned to the DRAC. |
IP Address | The IP address assigned to the DRAC. |
Login | The login name used to access the DRAC. |
Password | The password used to authenticate the connection to the DRAC. |
Module name | (optional) The module name for the DRAC when you have multiple DRAC modules. |
Password Script (optional) | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Use SSH (DRAC5 only) | (Rhel 4.8 and later) Indicates that system will use SSH to access the device. |
Field | Description |
---|---|
Name | A name for the BladeFrame device connected to the cluster. |
CServer | The hostname (and optionally the username in the form of username@hostname ) assigned to the device. Refer to the fence_egenera(8) man page for more information. |
ESH Path (optional) | The path to the esh command on the cserver (default is /opt/pan- mgr/bin/esh) |
lpan | The logical process area network (LPAN) of the device. |
pserver | The processing blade (pserver) name of the device. |
Field | Description |
---|---|
Name | A name for the RSB to use as a fence device. |
Hostname | The hostname assigned to the device. |
Login | The login name used to access the device. |
Password | The password used to authenticate the connection to the device. |
Password Script (optional) | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Field | Description |
---|---|
Name | A name for the GNBD device used to fence the cluster. Note that the GFS server must be accessed via GNBD for cluster node fencing support. |
Server | The hostname of the server to fence the client from, in either IP address or hostname form. For multiple hostnames, separate each hostname with a space. |
IP address | The cluster name of the node to be fenced. Refer to the fence_gnbd (8) man page for more information. |
Field | Description |
---|---|
Name | A name for the server with HP iLO support. |
Hostname | The hostname assigned to the device. |
Login | The login name used to access the device. |
Password | The password used to authenticate the connection to the device. |
Password Script (optional) | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Use SSH | (Rhel 4.8 and later) Indicates that system will use SSH to access the device. |
Field | Description |
---|---|
Name | A name for the IBM BladeCenter device connected to the cluster. |
IP Address | The IP address assigned to the device. |
Login | The login name used to access the device. |
Password | The password used to authenticate the connection to the device. |
Password Script (optional) | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Blade | The blade of the device. |
Use SSH | (Rhel 4.8 and later) Indicates that system will use SSH to access the device. |
Field | Description |
---|---|
Name | A name for the RSA device connected to the cluster. |
Hostname | The hostname assigned to the device. |
Login | The login name used to access the device. |
Password | The password used to authenticate the connection to the device. |
Password Script (optional) | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Field | Description |
---|---|
Name | A name for the IPMI LAN device connected to the cluster. |
IP Address | The IP address assigned to the IPMI port. |
Login | The login name of a user capable of issuing power on/off commands to the given IPMI port. |
Password | The password used to authenticate the connection to the IPMI port. |
Password Script (optional) | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Authentication Type | none , password , md2 , or md5 |
Use Lanplus | True or 1 . If blank, then value is False . |
Field | Description |
---|---|
Name | A name for the LPAR to use as a fence device. |
Hostname | The hostname assigned to the device. |
Login | The login name used to access the device. |
Password | The password used to authenticate the connection to the device. |
Password Script (optional) | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Partition | Name of LPAR partition to use as a fence device when there are multiple LPARs. |
hmc-version | Version 3 or 4. A value of 4 is the default. |
Managed | Name of the managed system. |
Field | Description |
---|---|
Name | A name to assign the Manual fencing agent. Refer to the fence_manual (8) man page for more information. |
Warning
Manual fencing is not supported for production environments.
Field | Description |
---|---|
Name | A name for the McData device connected to the cluster. |
IP Address | The IP address assigned to the device. |
Login | The login name used to access the device. |
Password | The password used to authenticate the connection to the device. |
Password Script (optional) | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Port | The switch outlet number. |
Field | Description |
---|---|
Name | A name for the SANBox2 device connected to the cluster. |
IP Address | The IP address assigned to the device. |
Login | The login name used to access the device. |
Password | The password used to authenticate the connection to the device. |
Password Script (optional) | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Port | The switch outlet number. |
Field | Description |
---|---|
Name | A name for the WTI RPS-10 power switch connected to the cluster. |
Device Name | The device name of the device the switch is connected to on the controlling host (for example, /dev/ttys2 ). |
Port | The switch outlet number. |
Field | Description |
---|---|
Name | A name for the SCSI fence device. |
Node name | Name of the node to be fenced. Refer to the fence_scsi (8) man page for more information. |
Field | Description |
---|---|
Name | Name of the virtual machine fencing device. |
Domain | Unique domain name of the guest to be fenced. |
Field | Description |
---|---|
Name | A name for the Vixel switch connected to the cluster. |
IP Address | The IP address assigned to the device. |
Password | The password used to authenticate the connection to the device. |
Password Script (optional) | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Port | The switch outlet number. |
Field | Description |
---|---|
Name | A name for the WTI power switch connected to the cluster. |
IP Address | The IP address assigned to the device. |
Password | The password used to authenticate the connection to the device. |
Password Script (optional) | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Port | The switch outlet number. |
Use SSH | (Rhel 4.8 and later) Indicates that system will use SSH to access the device. |