18.8. Troubleshooting issues in the Red Hat Gluster Storage Trusted Storage Pool


When enabling the network components to communicate with Jumbo frames in a Red Hat Gluster Storage Trusted Storage Pool, ensure that all the network components such as switches, Red Hat Gluster Storage nodes etc are configured properly. Verify the network configuration by running the ping from one Red Hat Gluster Storage node to another.
If the nodes in the Red Hat Gluster Storage Trusted Storage Pool or any other network components are not configured to fully support Jumbo frames, the ping command times out and displays the following error:
# ping -s 1600 '-Mdo'
local error: Message too long, mtu=1500
Copy to Clipboard Toggle word wrap