이 콘텐츠는 선택한 언어로 제공되지 않습니다.
Appendix B. Fence Device Parameters
This appendix provides tables with parameter descriptions of fence devices.
Note
Certain fence devices have an optional
parameter. The parameter allows specifying that a fence-device password is supplied from a script rather than from the parameter. Using the parameter supersedes the parameter, allowing passwords to not be visible in the cluster configuration file (/etc/cluster/cluster.conf
).
Field | Description |
---|---|
Name | A name for the APC device connected to the cluster. |
IP Address | The IP address assigned to the device. |
Login | The login name used to access the device. |
Password | The password used to authenticate the connection to the device. |
Password Script (optional) | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Port | The switch outlet number. |
Switch (optional) | The switch number for the APC switch that connects to the node when you have multiple daisy-chained switches. |
Use SSH | (Rhel 4.8 and later) Indicates that system will use SSH to access the device. |
Field | Description |
---|---|
Name | A name for the Brocade device connected to the cluster. |
IP Address | The IP address assigned to the device. |
Login | The login name used to access the device. |
Password | The password used to authenticate the connection to the device. |
Password Script (optional) | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Port | The switch outlet number. |
Field | Description |
---|---|
Name | A name for the Bull PAP system connected to the cluster. |
IP Address | The IP address assigned to the PAP console. |
Login | The login name used to access the PAP console. |
Password | The password used to authenticate the connection to the PAP console. |
Password Script (optional) | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Domain | Domain of the Bull PAP system to power cycle. |
Field | Description |
---|---|
Name | The name assigned to the DRAC. |
IP Address | The IP address assigned to the DRAC. |
Login | The login name used to access the DRAC. |
Password | The password used to authenticate the connection to the DRAC. |
Module name | (optional) The module name for the DRAC when you have multiple DRAC modules. |
Password Script (optional) | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Use SSH (DRAC5 only) | (Rhel 4.8 and later) Indicates that system will use SSH to access the device. |
Field | Description |
---|---|
Name | A name for the BladeFrame device connected to the cluster. |
CServer | The hostname (and optionally the username in the form of username@hostname ) assigned to the device. Refer to the fence_egenera(8) man page for more information. |
ESH Path (optional) | The path to the esh command on the cserver (default is /opt/pan- mgr/bin/esh) |
lpan | The logical process area network (LPAN) of the device. |
pserver | The processing blade (pserver) name of the device. |
Field | Description |
---|---|
Name | A name for the RSB to use as a fence device. |
Hostname | The hostname assigned to the device. |
Login | The login name used to access the device. |
Password | The password used to authenticate the connection to the device. |
Password Script (optional) | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Field | Description |
---|---|
Name | A name for the GNBD device used to fence the cluster. Note that the GFS server must be accessed via GNBD for cluster node fencing support. |
Server | The hostname of the server to fence the client from, in either IP address or hostname form. For multiple hostnames, separate each hostname with a space. |
IP address | The cluster name of the node to be fenced. Refer to the fence_gnbd (8) man page for more information. |
Field | Description |
---|---|
Name | A name for the server with HP iLO support. |
Hostname | The hostname assigned to the device. |
Login | The login name used to access the device. |
Password | The password used to authenticate the connection to the device. |
Password Script (optional) | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Use SSH | (Rhel 4.8 and later) Indicates that system will use SSH to access the device. |
Field | Description |
---|---|
Name | A name for the IBM BladeCenter device connected to the cluster. |
IP Address | The IP address assigned to the device. |
Login | The login name used to access the device. |
Password | The password used to authenticate the connection to the device. |
Password Script (optional) | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Blade | The blade of the device. |
Use SSH | (Rhel 4.8 and later) Indicates that system will use SSH to access the device. |
Field | Description |
---|---|
Name | A name for the RSA device connected to the cluster. |
Hostname | The hostname assigned to the device. |
Login | The login name used to access the device. |
Password | The password used to authenticate the connection to the device. |
Password Script (optional) | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Field | Description |
---|---|
Name | A name for the IPMI LAN device connected to the cluster. |
IP Address | The IP address assigned to the IPMI port. |
Login | The login name of a user capable of issuing power on/off commands to the given IPMI port. |
Password | The password used to authenticate the connection to the IPMI port. |
Password Script (optional) | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Authentication Type | none , password , md2 , or md5 |
Use Lanplus | True or 1 . If blank, then value is False . |
Field | Description |
---|---|
Name | A name for the LPAR to use as a fence device. |
Hostname | The hostname assigned to the device. |
Login | The login name used to access the device. |
Password | The password used to authenticate the connection to the device. |
Password Script (optional) | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Partition | Name of LPAR partition to use as a fence device when there are multiple LPARs. |
hmc-version | Version 3 or 4. A value of 4 is the default. |
Managed | Name of the managed system. |
Field | Description |
---|---|
Name | A name to assign the Manual fencing agent. Refer to the fence_manual (8) man page for more information. |
Warning
Manual fencing is not supported for production environments.
Field | Description |
---|---|
Name | A name for the McData device connected to the cluster. |
IP Address | The IP address assigned to the device. |
Login | The login name used to access the device. |
Password | The password used to authenticate the connection to the device. |
Password Script (optional) | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Port | The switch outlet number. |
Field | Description |
---|---|
Name | A name for the SANBox2 device connected to the cluster. |
IP Address | The IP address assigned to the device. |
Login | The login name used to access the device. |
Password | The password used to authenticate the connection to the device. |
Password Script (optional) | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Port | The switch outlet number. |
Field | Description |
---|---|
Name | A name for the WTI RPS-10 power switch connected to the cluster. |
Device Name | The device name of the device the switch is connected to on the controlling host (for example, /dev/ttys2 ). |
Port | The switch outlet number. |
Field | Description |
---|---|
Name | A name for the SCSI fence device. |
Node name | Name of the node to be fenced. Refer to the fence_scsi (8) man page for more information. |
Field | Description |
---|---|
Name | Name of the virtual machine fencing device. |
Domain | Unique domain name of the guest to be fenced. |
Field | Description |
---|---|
Name | A name for the Vixel switch connected to the cluster. |
IP Address | The IP address assigned to the device. |
Password | The password used to authenticate the connection to the device. |
Password Script (optional) | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Port | The switch outlet number. |
Field | Description |
---|---|
Name | A name for the WTI power switch connected to the cluster. |
IP Address | The IP address assigned to the device. |
Password | The password used to authenticate the connection to the device. |
Password Script (optional) | The script that supplies a password for access to the fence device. Using this supersedes the | parameter.
Port | The switch outlet number. |
Use SSH | (Rhel 4.8 and later) Indicates that system will use SSH to access the device. |