11.7.


11.7.1. 

  • # lsmod | grep vfio
    Copy to Clipboard Toggle word wrap

  1. # lspci -nkD
    
    0000:00:00.0 0600: 8086:a708 (rev 01)
    	Subsystem: 17aa:230e
    	Kernel driver in use: igen6_edac
    	Kernel modules: igen6_edac
    0000:00:02.0 0300: 8086:a7a1 (rev 04)
    	Subsystem: 17aa:230e
    	Kernel driver in use: i915
    	Kernel modules: i915, xe
    0000:00:04.0 1180: 8086:a71d (rev 01)
    	Subsystem: 17aa:230e
    	Kernel driver in use: proc_thermal_pci
    	Kernel modules: processor_thermal_device_pci
    0000:00:05.0 0604: 8086:a74d (rev 01)
    	Subsystem: 17aa:230e
    	Kernel driver in use: pcieport
    0000:00:07.0 0604: 8086:a76e (rev 01)
    	Subsystem: 17aa:230e
    	Kernel driver in use: pcieport
    0000:65:00.0 0108: 144d:a822 (rev 01)
        DeviceName: PCIe SSD in Slot 0 Bay 2
        Subsystem: 1028:1fd9
        Kernel driver in use: nvme
        Kernel modules: nvme
    0000:6a:00.0 0108: 1179:0110 (rev 01)
        DeviceName: PCIe SSD in Slot 11 Bay 2
        Subsystem: 1028:1ffb
        Kernel driver in use: nvme
        Kernel modules: nvme
    Copy to Clipboard Toggle word wrap
  2. # virsh edit vm-name
    Copy to Clipboard Toggle word wrap
  3. <hostdev mode="subsystem" type="pci" managed="yes">
      <driver name="vfio"/>
       <source>
        <address domain="0x0000" bus="0x65" slot="0x00" function="0x0"/>
       </source>
       <address type="pci" domain='0x0000' bus='0x02' slot='0x00' function='0x0'/>
    </hostdev>
    Copy to Clipboard Toggle word wrap
  4. <hostdev mode="subsystem" type="pci" managed="yes">
      <driver name="vfio"/>
       <source>
        <address domain="0x0000" bus="0x65" slot="0x00" function="0x0"/>
       </source>
       <address type="pci" domain='0x0000' bus='0x02' slot='0x00' function='0x0'>
         <zpci uid="0x0008" fid="0x001807"/>
       </address>
    </hostdev>
    Copy to Clipboard Toggle word wrap

  5. # virsh shutdown vm-name
    Copy to Clipboard Toggle word wrap

  1. # lspci -nkD | grep 0000:02:00.0
    
    0000:02:00.0 8086:9a09 (rev 01)
    Copy to Clipboard Toggle word wrap

11.7.2. 

注意

  • 注意

    # virsh edit example-VM-1
    Copy to Clipboard Toggle word wrap
  • # virsh dumpxml example-VM-1 > example-VM-1.xml
    Copy to Clipboard Toggle word wrap

11.7.3. 

  1. # virsh dumpxml <VM-name>
    
    [...]
    <hostdev mode='subsystem' type='pci' managed='yes'>
      <source>
        <address domain='0x0000' bus='0x65' slot='0x00' function='0x0'/>
      </source>
      <address type='pci' domain='0x0000' bus='0x02' slot='0x00' function='0x0'/>
    </hostdev>
    [...]
    Copy to Clipboard Toggle word wrap
  2. # virt detach-device <VM-name> --hostdev 0000:65:00.0 --config
    Domain 'VM-name' defined successfully.
    Copy to Clipboard Toggle word wrap
    注意

  3. # virsh nodedev-reattach pci_0000_65_00_0
    Device pci_0000_65_00_0 re-attached
    Copy to Clipboard Toggle word wrap

  1. # virsh dumpxml <VM-name>
    Copy to Clipboard Toggle word wrap

11.7.4. 

警告

# virsh edit <example-VM-1>
Copy to Clipboard Toggle word wrap

  • # virsh dumpxml testguest1 > testguest1.xml
    # cat testguest1.xml
    <domain type='kvm' xmlns:qemu='http://libvirt.org/schemas/domain/qemu/1.0'>
      <name>testguest1</name>
      <uuid>ede29304-fe0c-4ca4-abcd-d246481acd18</uuid>
      [...]
    </domain>
    Copy to Clipboard Toggle word wrap

  • # virsh define testguest1.xml
    Copy to Clipboard Toggle word wrap
返回顶部