此内容没有您所选择的语言版本。

11.6. ceilometer alarm-event-create


usage: ceilometer alarm-event-create --name <NAME>
                                     [--project-id <ALARM_PROJECT_ID>]
                                     [--user-id <ALARM_USER_ID>]
                                     [--description <DESCRIPTION>]
                                     [--state <STATE>] [--severity <SEVERITY>]
                                     [--enabled {True|False}]
                                     [--alarm-action <Webhook URL>]
                                     [--ok-action <Webhook URL>]
                                     [--insufficient-data-action <Webhook URL>]
                                     [--time-constraint <Time Constraint>]
                                     [--repeat-actions {True|False}]
                                     [--event-type <EVENT_TYPE>] [-q <QUERY>]
Copy to Clipboard Toggle word wrap
Create a new alarm based on events.

Optional arguments

--name <NAME>


        Name of the alarm (must be unique per tenant).
      Required.

--project-id <ALARM_PROJECT_ID>


      Tenant to associate with alarm (configurable
      by admin users only).

--user-id <ALARM_USER_ID>


        User to associate with alarm (configurable by
      admin users only).

--description <DESCRIPTION>


        Free text description of the alarm.

--state <STATE>


        State of the alarm, one of: ['ok', 'alarm',
      'insufficient data']

--severity <SEVERITY>


        Severity of the alarm, one of: ['low',
      'moderate', 'critical']

--enabled {True|False}


        True if alarm evaluation/actioning is enabled.

--alarm-action <Webhook URL> URL


        to invoke when state transitions to alarm.
      May be used multiple times. Defaults to None.

--ok-action <Webhook URL> URL


        to invoke when state transitions to OK.
      May be used multiple times. Defaults to None.

--insufficient-data-action <Webhook URL>


      URL to invoke when state transitions to
      insufficient data. May be used multiple times.
      Defaults to None.

--time-constraint <Time Constraint>


      Only evaluate the alarm if the time at
      evaluation is within this time constraint.
      Start point(s) of the constraint are specified
      with a cron expression, whereas its duration
      is given in seconds. Can be specified multiple
      times for multiple time constraints, format
      is: name=<CONSTRAINT_NAME>;start=<CRON>;durati
      on=<SECONDS>;[description=<DESCRIPTION>;[timez
      one=<IANA Timezone>]] Defaults to None.

--repeat-actions {True|False}


      True if actions should be repeatedly notified
      while alarm remains in target state.

--event-type <EVENT_TYPE>


        Event type for event alarm.

-q <QUERY>, --query <QUERY>


        key[op]data_type::value; list for filtering
      events. data_type is optional, but if supplied
      must be string, integer, float or datetime.