이 콘텐츠는 선택한 언어로 제공되지 않습니다.

5.3.8. /proc/scsi/


This directory is analogous to the /proc/ide/ directory, but it is for connected SCSI devices.
The primary file in this directory is /proc/scsi/scsi, which contains a list of every recognized SCSI device. From this listing, the type of device, as well as the model name, vendor, SCSI channel and ID data is available.
For example, if a system contains a SCSI CD-ROM, a tape drive, a hard drive, and a RAID controller, this file looks similar to the following:
Attached devices: 
Host: scsi1 Channel: 00 Id: 05 Lun: 00
  Vendor: NEC      Model: CD-ROM DRIVE:466 Rev: 1.06
  Type:   CD-ROM                           ANSI SCSI revision: 02
Host: scsi1 Channel: 00 Id: 06 Lun: 00
  Vendor: ARCHIVE  Model: Python 04106-XXX Rev: 7350
  Type:   Sequential-Access                ANSI SCSI revision: 02
Host: scsi2 Channel: 00 Id: 06 Lun: 00
  Vendor: DELL     Model: 1x6 U2W SCSI BP  Rev: 5.35
  Type:   Processor                        ANSI SCSI revision: 02
Host: scsi2 Channel: 02 Id: 00 Lun: 00
  Vendor: MegaRAID Model: LD0 RAID5 34556R Rev: 1.01
  Type:   Direct-Access                    ANSI SCSI revision: 02
Each SCSI driver used by the system has its own directory within /proc/scsi/, which contains files specific to each SCSI controller using that driver. From the previous example, aic7xxx/ and megaraid/ directories are present, since two drivers are in use. The files in each of the directories typically contain an I/O address range, IRQ information, and statistics for the SCSI controller using that driver. Each controller can report a different type and amount of information. The Adaptec AIC-7880 Ultra SCSI host adapter's file in this example system produces the following output:
Adaptec AIC7xxx driver version: 5.1.20/3.2.4
Compile Options:
  TCQ Enabled By Default : Disabled
  AIC7XXX_PROC_STATS     : Enabled
  AIC7XXX_RESET_DELAY    : 5

Adapter Configuration:
           SCSI Adapter: Adaptec AIC-7880 Ultra SCSI host adapter
                           Ultra Narrow Controller
    PCI MMAPed I/O Base: 0xfcffe000
 Adapter SEEPROM Config: SEEPROM found and used.
      Adaptec SCSI BIOS: Enabled
                    IRQ: 30
                   SCBs: Active 0, Max Active 1,
                         Allocated 15, HW 16, Page 255
             Interrupts: 33726
      BIOS Control Word: 0x18a6
   Adapter Control Word: 0x1c5f
   Extended Translation: Enabled
Disconnect Enable Flags: 0x00ff
     Ultra Enable Flags: 0x0020
 Tag Queue Enable Flags: 0x0000
Ordered Queue Tag Flags: 0x0000
Default Tag Queue Depth: 8
    Tagged Queue By Device array for aic7xxx host instance 1:
      {255,255,255,255,255,255,255,255,255,255,255,255,255,255,255,255}
    Actual queue depth per device for aic7xxx host instance 1:
      {1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1}

Statistics:


(scsi1:0:5:0)
  Device using Narrow/Sync transfers at 20.0 MByte/sec, offset 15
  Transinfo settings: current(12/15/0/0), goal(12/15/0/0), user(12/15/0/0)
  Total transfers 0 (0 reads and 0 writes)
             < 2K      2K+     4K+     8K+    16K+    32K+    64K+   128K+
   Reads:       0       0       0       0       0       0       0       0
  Writes:       0       0       0       0       0       0       0       0


(scsi1:0:6:0)
  Device using Narrow/Sync transfers at 10.0 MByte/sec, offset 15
  Transinfo settings: current(25/15/0/0), goal(12/15/0/0), user(12/15/0/0)
  Total transfers 132 (0 reads and 132 writes)
             < 2K      2K+     4K+     8K+    16K+    32K+    64K+   128K+
   Reads:       0       0       0       0       0       0       0       0
  Writes:       0       0       0       1     131       0       0       0
This output reveals the transfer speed to the SCSI devices connected to the controller based on channel ID, as well as detailed statistics concerning the amount and sizes of files read or written by that device. For example, this controller is communicating with the CD-ROM at 20 megabytes per second, while the tape drive is only communicating at 10 megabytes per second.
Red Hat logoGithubRedditYoutubeTwitter

자세한 정보

평가판, 구매 및 판매

커뮤니티

Red Hat 문서 정보

Red Hat을 사용하는 고객은 신뢰할 수 있는 콘텐츠가 포함된 제품과 서비스를 통해 혁신하고 목표를 달성할 수 있습니다.

보다 포괄적 수용을 위한 오픈 소스 용어 교체

Red Hat은 코드, 문서, 웹 속성에서 문제가 있는 언어를 교체하기 위해 최선을 다하고 있습니다. 자세한 내용은 다음을 참조하세요.Red Hat 블로그.

Red Hat 소개

Red Hat은 기업이 핵심 데이터 센터에서 네트워크 에지에 이르기까지 플랫폼과 환경 전반에서 더 쉽게 작업할 수 있도록 강화된 솔루션을 제공합니다.

© 2024 Red Hat, Inc.