Remote Direct Memory Access (RDMA) over Converged Ethernet (RoCE) is a network protocol that uses RDMA over an Ethernet network. For configuration, RoCE requires specific hardware and some of the hardware vendors are Mellanox, Broadcom, and QLogic.
RoCE protocol versions and their differences Copy linkLink copied!
Understanding the differences between the different RoCE versions is crucial for designing efficient and scalable network infrastructures.
The following are the different RoCE versions:
- RoCE v1
- The RoCE version 1 protocol is an Ethernet link layer protocol with Ethertype
0x8915that enables the communication between any two hosts in the same Ethernet broadcast domain. - RoCE v2
- The RoCE version 2 protocol exists on the top of either the UDP over IPv4 or the UDP over IPv6 protocol. For RoCE v2, the UDP destination port number is
4791.
The RDMA_CM sets up a reliable connection between a client and a server for transferring data. RDMA_CM provides an RDMA transport-neutral interface for establishing connections. The communication uses a specific RDMA device and message-based data transfers.
Using different versions, such as RoCE v2 on the client and RoCE v1 on the server is not supported. In such a case, configure both the server and client to communicate over RoCE v1.
RoCE v1 works at the Data Link layer (Layer 2) and only supports the communication of two machines in the same network. By default, RoCE v2 is available. It works at the Network Layer (Layer 3). RoCE v2 supports packet routing that provides a connection with multiple Ethernet.
Temporarily change the default RoCE version Copy linkLink copied!
Using the RoCE v2 protocol on the client and RoCE v1 on the server is not supported. If the hardware in your server supports RoCE v1 only, configure your clients for RoCE v1 to communicate with the server.
Before you begin Copy linkLink copied!
- The client uses an InfiniBand device with RoCE v2 protocol.
- The server uses an InfiniBand device that only supports RoCE v1.
About this task Copy linkLink copied!
For example, you can configure a client that uses the mlx5_0 driver for the Mellanox ConnectX-5 InfiniBand device that only supports RoCE v1.
The changes described here remain effective until you reboot the host.